Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Ann Vasc Surg ; 72: 98-105, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33227467

RESUMO

BACKGROUND: The aim of this study was to investigate the impact of number of vessels targeted by fenestrations or branches on early outcomes of fenestrated-branched endovascular aortic repair (F-BEVAR) for complex abdominal aortic aneurysms (cAAAs). METHODS: The clinical data of 260 patients (209 men; mean, 74 ± 7 years) treated for cAAAs in four academic centers using fenestrated-branched stent grafts with one to five fenestrations or branches were entered into prospectively maintained databases (2010-2015). Data were analyzed in patients treated with ≤2-vessel (group 1, n = 124), 3-vessel (group 2, n = 80), or ≥4 fenestrations or directional branches (group 3, n = 56). For group definition, only vessels incorporated by fenestrations or directional branches were accounted. End points were technical success, procedural variables, 30-day mortality, and major adverse events (MAEs). RESULTS: A total of 830 vessels (mean, 3.19 ± 0.8 vessels/patient) were targeted by fenestrations (n = 672), scallops (n = 136), or branches (n = 22). Two-vessel designs were used more often in the early experience (64%), whereas ≥3-vessel design (groups 2 and 3) was preferred in the late experience (68%, P < 0.05). Patients with ≥4-vessel designs had longer operating and fluoroscopy time (+78 min, P < 0.0001 and + 27 min, P < 0.001), higher volume of contrast use (+31 mL, P = 0.03), and longer hospital stay (+3 days, P = 0.007) of those who had ≤2-vessel designs. Technical success, estimated blood loss, mortality, MAEs, and rate of spinal cord injury were similar in all three groups (P > 0.05). CONCLUSIONS: F-BEVAR for complex abdominal aortic aneurysms was associated with high technical success and low 30-day mortality and morbidity. Increasing complexity was associated with longer operating and fluoroscopy time, more contrast use, and longer hospital stay but did not affect technical success and MAEs of the procedure.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/mortalidade , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Tempo de Internação , Masculino , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
2.
J Vasc Surg ; 69(3): 651-660.e4, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30154012

RESUMO

OBJECTIVE: Renal function deterioration is an important determinant of mortality in patients treated for complex aortic aneurysms. We have previously determined that catheter and guidewire manipulation in diseased aortas during fenestrated-branched endovascular aneurysm repair (F-BEVAR) is associated with risk of renal function deterioration. The aim of this study was to describe the impact of atherothrombotic aortic wall thrombus (AWT) on renal function deterioration among patients treated by F-BEVAR for pararenal and extent IV thoracoabdominal aortic aneurysms. METHODS: Clinical data of 212 patients treated for complex aortic aneurysms with F-BEVAR were entered into a prospectively maintained database (2007-2015). AWT was evaluated by computed tomography angiography using volumetric measurements in nonaneurysmal aortic segments. AWT was classified as mild, moderate, or severe using objective assessment of the number of affected segments, thrombus type, thickness, area, and circumference. Acute kidney injury (AKI) was defined using Risk, Injury, Failure, Loss of kidney function, and End-stage renal disease (RIFLE) criteria, and renal function deterioration was defined by a decline in estimated glomerular filtration rate (eGFR) >30% from baseline. Patient survival and renal outcomes were assessed at dismissal, at 6 to 8 weeks, at 6 months, and annually, including AKI, serum creatinine concentration, eGFR, chronic kidney disease stage, need for renal replacement therapy, and presence of kidney infarction. RESULTS: There were 169 male (80%) and 43 female (20%) patients with a mean age of 75 ± 7 years. Aneurysm extent was pararenal in 157 patients and extent IV thoracoabdominal aortic aneurysm in 55 patients. A total of 700 renal-mesenteric arteries were incorporated (3.1 ± 1 vessels/patient). AWT was classified as mild in 98 patients (46%), moderate in 75 (35%), and severe in 39 (19%). At 30 days, 45 patients (21%) developed AKI. Decline in eGFR and kidney infarction were associated with higher AWT volume index and severe AWT classification (P < .05). There was no association of AWT with 30-day mortality, which was 0.5% for the entire cohort. Mean follow-up was 29 ± 23 months. Freedom from renal function deterioration was 73% ± 6% for mild, 81% ± 6% for moderate, and 66% ± 8% for severe AWT patients at 3 years (P = .012) and 46% ± 9% and 82% ± 4% for those with or without AKI after the initial procedure (P < .001). Overall, 41 patients (19%) had progression of chronic kidney disease stage, but none of the patients required renal replacement therapy. Survival was 73% ± 5% for mild, 72% ± 6% for moderate, and 69% ± 10% for severe AWT patients at 3 years (P = .67). CONCLUSIONS: AWT is a significant predictor of AKI and continued decline in renal function after the initial F-BEVAR procedure. Longer follow-up time is needed to determine the actual impact of AWT on survival.


Assuntos
Injúria Renal Aguda/etiologia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Taxa de Filtração Glomerular , Rim/fisiopatologia , Trombose/complicações , Injúria Renal Aguda/mortalidade , Injúria Renal Aguda/fisiopatologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Trombose/mortalidade , Fatores de Tempo , Resultado do Tratamento
3.
J Vasc Surg ; 63(5): 1163-1169.e1, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26947527

RESUMO

OBJECTIVE: This study evaluated renal artery (RA) and accessory renal artery (ARA) anatomy and implications for endovascular repair using fenestrated, branched, or parallel (chimney, snorkel, and periscope) stent graft techniques. METHODS: We analyzed the digital computed tomography angiograms of 520 consecutive patients treated by open or fenestrated endovascular repair for complex abdominal aortic aneurysms (2000-2012). RA/ARA anatomy was assessed using diameter, length, angles, and kidney perfusion based on analysis of estimated volumetric kidney parenchyma. Endovascular suitability was determined by RA diameter ≥4 mm, length to RA bifurcation ≥13 mm, and preservation of >75% of a single kidney or >60% of two kidneys by volumetric kidney parenchyma analysis. RESULTS: There were 222 juxtarenal (43%), 241 suprarenal (46%), and 57 type IV thoracoabdominal aortic aneurysms (11%), Analysis of 1009 RAs and 177 ARAs showed endovascular incorporation was possible in 884 RAs (88%) and 30 ARAs (17%) using the proposed criteria. One or more factors rendered RA incorporation unsuitable in 97 patients (19%), including early bifurcation in 45 (9%), small diameter in 28 (5%), or inability to preserve kidney parenchyma in 28 (5%). Other anatomic issues were present in 170 patients (33%) that would increase technical difficulty to RA incorporation using transfemoral access, including excessive downward angulation in 125 (24%), high-grade stenosis in 51 (10%), or prior renal stents in 11 (2%). CONCLUSIONS: Independent of the endovascular technique that is selected to treat a complex abdominal aortic aneurysm, one of five patients has anatomic limitations to endovascular incorporation. In these patients, open repair may provide the best alterative to maximize RA patency and preserve renal function.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Artéria Renal/cirurgia , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Minnesota , Desenho de Prótese , Artéria Renal/diagnóstico por imagem , Artéria Renal/fisiopatologia , Estudos Retrospectivos , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
4.
J Endovasc Ther ; 23(1): 139-49, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26637837

RESUMO

PURPOSE: To review outcomes of continuous motor/somatosensory-evoked potential (MEP/SSEP) monitoring, cerebrospinal fluid drainage, and selective use of iliofemoral conduits in patients undergoing endovascular repair of descending thoracic aneurysm (DTA) and thoracoabdominal aortic aneurysms (TAAAs). METHODS: The clinical data of 49 patients (mean age 75±8 years; 38 men) who underwent endovascular repair of DTA and TAAAs (2011-2014) were reviewed. All patients had cerebrospinal fluid drainage, permissive hypertension (mean arterial pressure ≥80 mm Hg), and MEP/SSEP monitoring. There were 44 (90%) patients with TAAAs and 5 (10%) with DTA. Types I and II TAAAs were repaired in staged procedures. Iliofemoral conduits were used for small iliac arteries and to minimize time of lower extremity ischemia in patients with difficult anatomy. In patients with changes in MEP/SSEPs, a standardized protocol was employed to optimize spinal cord perfusion and restore lower extremity blood flow. Endpoints were mortality, spinal cord injury (SCI), and lower extremity ischemic complications. RESULTS: Sixteen (33%) patients had staged TAAA repair. A total of 163 visceral arteries were targeted by fenestrations and branches (mean 3.7±1.0 vessels/patient). Temporary iliofemoral conduits were used in 16 limbs/14 patients. A stable MEP/SSEP was achieved in all patients. Thirty-one (63%) patients had a ≥75% decrease in MEP/SSEP amplitude in 50 limbs starting on average 75±28 minutes after obtaining vascular access. MEP/SSEP amplitude improved with maneuvers in 12 (39%) patients and returned to baseline with restoration of lower extremity flow in all except 1 patient who developed immediate SCI. Thirty-day mortality was 4%. Three (6%) patients had SCI, 2 permanent and 1 temporary at 14 days. There were no lower extremity ischemic complications. CONCLUSION: Neuromonitoring predicted immediate SCI and allowed use of a protocol to optimize spinal cord and lower extremity perfusion during complex endovascular aortic repair. Larger clinical experience is needed to evaluate the efficacy of neuromonitoring to prevent SCI.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Vazamento de Líquido Cefalorraquidiano , Procedimentos Endovasculares/instrumentação , Artéria Femoral/cirurgia , Artéria Ilíaca/cirurgia , Monitorização Neurofisiológica Intraoperatória , Traumatismos da Medula Espinal/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/mortalidade , Aneurisma da Aorta Torácica/fisiopatologia , Pressão Arterial , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Potencial Evocado Motor , Potenciais Somatossensoriais Evocados , Feminino , Artéria Femoral/fisiopatologia , Humanos , Artéria Ilíaca/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fluxo Sanguíneo Regional , Estudos Retrospectivos , Fatores de Risco , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/mortalidade , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/mortalidade , Fatores de Tempo , Resultado do Tratamento
5.
J Thorac Cardiovasc Surg ; 153(2): S32-S41.e7, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27866781

RESUMO

PURPOSE: The study purpose was to review the outcomes of patients treated for thoracoabdominal aortic aneurysms using endovascular repair with fenestrated and branched stent-grafts in a single center. METHODS: We reviewed the clinical data of the first 185 consecutive patients (134 male; mean age, 75 ± 7 years) treated for thoracoabdominal aortic aneurysms using fenestrated and branched stent-grafts. Graft design evolved from physician-modified endografts (2007-2013) to off-the-shelf or patient-specific manufactured devices in patients enrolled in a prospective physician-sponsored investigational device exemption protocol (NCT 1937949 and 2089607). Outcomes were reported for extent IV and extent I to III thoracoabdominal aortic aneurysms, including 30-day mortality, major adverse events, patient survival, primary target vessel patency, and reintervention. RESULTS: A total of 112 patients (60%) were treated for extent IV thoracoabdominal aortic aneurysms, and 73 patients (40%) were treated for extent I to III thoracoabdominal aortic aneurysms. Demographics and cardiovascular risk factors were similar in both groups. A total of 687 renal-mesenteric arteries (3.7 vessels/patient) were targeted by 540 fenestrations and 147 directional branches. Technical success was 94%. Thirty-day mortality was 4.3%, including a mortality of 1.8% for extent IV and 8.2% for extent I to III thoracoabdominal aortic aneurysms (P = .03). Mortality decreased in the second half of clinical experience from 7.5% to 1.2%, including a decrease of 3.3% to 0% for extent IV thoracoabdominal aortic aneurysms (P = .12) and 15.6% to 2.4% for extent I to III thoracoabdominal aortic aneurysms (P = .04). Early major adverse events occurred in 36 patients (32%) with extent IV thoracoabdominal aortic aneurysms and 26 patients (36%) with extent I to III thoracoabdominal aortic aneurysms, including spinal cord injury in 2 patients (1.8%) and 4 patients (3.2%), respectively. Mean follow-up was 21 ± 20 months. At 5 years, patient survival (56% and 59%, P = .37) and freedom from any reintervention (50% and 53%, P = .26) were similar in those with extent IV and extent I to III thoracoabdominal aortic aneurysms. Primary patency was 93% at 5 years. CONCLUSIONS: Endovascular repair of thoracoabdominal aortic aneurysms can be performed with high technical success and low mortality and morbidity. However, the need for secondary reinterventions and continued graft surveillance represents major limitations compared with results of conventional open surgical repair. Long-term follow-up is needed before the widespread use of these techniques in younger or lower-risk patients.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Idoso , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Angiografia por Tomografia Computadorizada , Feminino , Seguimentos , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa