Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Nucl Cardiol ; 24(2): 405-409, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-26494645

RESUMO

Pharmacological stress tests using dipyridamole are considered to be safe. However, cases of atrioventricular (AV) block have been reported. We retrospectively analyzed ECG at baseline and during dipyridamole stress tests of 2010 consecutive patients (patients with second or third degree AV block were excluded). At baseline, 350 (17.4%) patients had conduction abnormalities. Following dipyridamole infusion 16 patients (0.8%) developed a transient change in AV conduction (15 patients) and or sinus arrest (1 patient). Compared to patients without baseline conduction abnormalities, patients with any conduction abnormalities at baseline were at a higher risk for the development of AV block after dipyridamole infusion [0.3% vs 3.14%, respectively; P < .0001].


Assuntos
Bloqueio Atrioventricular/epidemiologia , Bradicardia/epidemiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Dipiridamol , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Teste de Esforço/estatística & dados numéricos , Bloqueio Atrioventricular/diagnóstico , Bradicardia/diagnóstico , Causalidade , Comorbidade , Feminino , Humanos , Incidência , Israel/epidemiologia , Masculino , Compostos Radiofarmacêuticos , Fatores de Risco , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Vasodilatadores
2.
Med Biol Eng Comput ; 57(7): 1581-1590, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31025249

RESUMO

The accuracy of recently approved quantitative clinical software was determined by comparing in vivo/in vitro measurements for a solid-state cadmium-zinc-telluride SPECT/CT (single photon emission computed tomography/x-ray computed tomography) camera. Bone SPECT/CT, including the pelvic region in the field of view, was performed on 16 patients using technetium-99m methylene diphosphonic acid as a radiotracer. After imaging, urine samples from each patient provided for the measurement of in vitro radiopharmaceutical concentrations. From the SPECT/CT images, three users measured in vivo radiotracer concentration and standardized uptake value (SUV) for the bladder using quantitative software (Q.Metrix, GE Healthcare). Linear regression was used to validate any in vivo/in vitro identity relations (ideally slope = 1, intercept = 0), within a 95% confidence interval (CI). Thirteen in vivo/in vitro pairs were available for further analysis, after rejecting two as clinically irrelevant (SUVs > 100 g/mL) and one as an outlier (via Cook's distance calculations). All linear regressions (R2 ≥ 0.85, P < 0.0001) provided identity in vivo/in vitro relations (95% CI), with SUV averages from all users giving a slope of 0.99 ± 0.25 and intercept of 0.14 ± 5.15 g/mL. The average in vivo/in vitro residual difference was < 20%. Solid-state SPECT/CT imaging can reliably provide in vivo urinary bladder radiotracer concentrations within approximately 20% accuracy. This practical, non-invasive, in vivo quantitation method can potentially improve diagnosis and assessment of response to treatment. Graphical abstract.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Cintilografia/métodos , Compostos Radiofarmacêuticos/análise , Software , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cádmio , Calibragem , Difosfonatos/administração & dosagem , Difosfonatos/análise , Difosfonatos/urina , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos de Organotecnécio/administração & dosagem , Compostos de Organotecnécio/análise , Compostos de Organotecnécio/urina , Imagens de Fantasmas , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/urina , Telúrio , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Bexiga Urinária/diagnóstico por imagem , Imagem Corporal Total/métodos , Zinco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa