Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Echocardiography ; 30(1): 72-80, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23006427

RESUMO

BACKGROUND: We sought to develop and validate an intracardiac echocardiography (ICE) imaging strategy for evaluation of left atrial (LA) appendage (LAA) anatomy and function to clarify equivocal findings of LAA thrombus with transesophageal echocardiography (TEE). METHODS: A total of 56 patients with ICE imaging of the LAA for thrombus evaluation before atrial fibrillation (AF) or ventricular tachycardia (VT) ablation were included for analysis. Serial views of the LAA were obtained for evaluating anatomic structures and flow as the ICE transducer was advanced from the right ventricular outflow tract to the pulmonary artery. ICE imaging of the LAA was selectively performed in 9 of 56 patients following equivocal findings of thrombus on TEE in order to evaluate the complementary role of ICE to TEE in the diagnosis of LAA thrombus. RESULTS: ICE imaging of the LAA in 56 patients with AF (n = 42) or VT (n = 14) measured the long-(5.0 ± 1.0 cm) and short-axis dimension (1.8 ± 0.5 cm), and peak emptying flow velocity (50 ± 23 cm/s). Of 56 patients, 47 had ICE imaging of LAA with no thrombus. In the remaining 9 patients, 6 had "equivocal" LAA thrombus on TEE, with 3 of these 6 showing marked spontaneous echo contrast (SEC), whereas ICE detected one patient with LAA thrombus and the other 5 without thrombus (two with severe SEC/sluggish flow); the remaining 3 had "high suspicion" for thrombus detected by TEE, whereas ICE detected only one with LAA thrombus. Based on ICE diagnosis, two patients with LAA thrombus had the procedure cancelled, and all others had successful completion of the scheduled procedures. CONCLUSION: ICE can provide serial assessment, multiple views, and detailed imaging of the LAA to reliably diagnose the presence of thrombus. Our findings support the use of ICE when equivocal TEE findings require confirmation prior to electrophysiological procedures.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Endossonografia/métodos , Cardiopatias/diagnóstico por imagem , Trombose/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Circulation ; 124(7): 772-8, 2011 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-21788588

RESUMO

BACKGROUND: Mobile thrombi, not routinely recognized on transthoracic echocardiography, are frequently identified on cardiovascular implantable electronic device leads with intracardiac echocardiography (ICE) during ablation procedures. Their incidence, characteristics, and consequences have not yet been defined. METHODS AND RESULTS: We used ICE to examine leads for thrombi and to measure the pulmonary artery systolic pressure in patients with a cardiovascular implantable electronic device presenting for ablation. Patient clinical characteristics, device type, and lead characteristics were correlated with presence of thrombi. Most patients had congestive heart failure (84%), with an average left ventricular ejection fraction of 40%. Thrombi were seen with ICE in 26 of 86 patients (30%) but were seen on transthoracic echocardiography in only 1 of the 26 patients. Thrombi on ICE were mobile, averaged 18 ± 5.9 mm long by 4.4 ± 2.3 mm wide, and were more commonly identified in the right atrium (n=25) than in the right ventricle (n=5). Thrombi were associated with higher pulmonary artery systolic pressure: 39 ± 9 mm Hg with thrombi versus 33 ± 7 mm Hg without thrombi (odds ratio, 1.11; 95% confidence interval, 1.03 to 1.20; P=0.01). No other characteristic assessed was associated with a significant difference in the presence of lead thrombi. CONCLUSIONS: Mobile thrombi on cardiovascular implantable electronic device leads are present in 30% of patients undergoing ablation and are readily identified with ICE despite being underrecognized with transthoracic echocardiography. Further study is warranted to determine whether lead thrombi are a clinically relevant source of pulmonary emboli in some patients with cardiovascular implantable electronic devices.


Assuntos
Ecocardiografia/métodos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/epidemiologia , Marca-Passo Artificial/efeitos adversos , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia , Idoso , Pressão Sanguínea/fisiologia , Ablação por Cateter , Desfibriladores Implantáveis/efeitos adversos , Ecocardiografia/normas , Eletrodos Implantados/efeitos adversos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Hipertensão Pulmonar/fisiopatologia , Incidência , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Trombose Venosa/fisiopatologia
3.
J Atr Fibrillation ; 13(5): 2509, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34950343

RESUMO

Objectives: Intracardiac echocardiography(ICE) has excellent imaging resolution and border recognition which increase strain measurement accuracy. We hypothesized that left atrial(LA) substrate and functional impairment can be detected by measuring LA strain deformation in patients with persistent and paroxysmal atrial fibrillation(AF), as compared to those with no AF. Strain deformation changes in LA and left ventricle(LV) can also be assessed post-ablation to determine its effect. Methods: ICE-derived speckle tracking strain(STS) was prospectively performed in 96 patients, including 62 patients with AF(31 persistent and 31 paroxysmal AF) pre-/post-ablation, and 34 patients with no AF. We measured major strain parameters including longitudinal segmental(endo/myocardial) "average peak overall strain of all segments"(PkAll), peak strain rate(SR),and different time-to-peak strain in LA and LV images. Results: At baseline, persistent AF patients had significantly lower(p<0.01) LA endocardial(4.3±2.5 vs. 20.3±8.9 and 25.5±12.9 %) and myocardial PkAll(4.4±2.6 vs. 15.7±7.2 and 20.9±9.2 %), endocardial(0.9±0.4 vs. 1.8±0.7 and 2.2±0.6 1/s) and myocardial peak SR(0.7±0.4 vs. 1.5±0.6 and 1.9±0.5 1/s), as compared to paroxysmal AF and no AF patients. After successful ablation, endo-/myocardial LA PkAll and peak SR were significantly improved, most dramatically in patients with persistent AF. LV endocardial/myocardial strain and SR also improved in AF patients post-ablation. Conclusion: LA longitudinal strain(%)/SR(1/s) parameters in AF patients are more abnormal than those with no AF, suggesting LA substrate/functional damage. AF ablation improved LA strains/SR but with values in paroxysmal > persistent AF suggesting background LA damage in persistent AF.

4.
Circulation ; 120(5): 366-75, 2009 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-19620503

RESUMO

BACKGROUND: Efficacy of endocardial ventricular tachycardia (VT) ablation in arrhythmogenic right ventricular cardiomyopathy/dysplasia may be limited by epicardial VT, right ventricular thickening, or both. We sought to characterize the endocardial versus epicardial substrate, measure right ventricular free wall thickness, and determine epicardial ablation efficacy in patients with right ventricular cardiomyopathy/dysplasia. METHODS AND RESULTS: Thirteen consecutive patients (3 female; aged 43+/-15 years; range, 17 to 70 years) undergoing endocardial and epicardial sinus rhythm voltage mapping and epicardial VT ablation after failed endocardial VT ablation were included. In each patient, the low bipolar voltage area (<1.0 mV for epicardium and <1.5 mV for endocardium) was more extensive on the epicardium (95+/-47 versus 38+/-32 cm(2); P<0.001) and was uniformly marked by multicomponent and late electrograms. The basal right ventricular thickness assessed by electroanatomic map was >10 mm in 6 of 13 patients compared with 5 to 10 mm in 4 reference patients without structural disease. Twenty-seven VTs were targeted on the epicardium with the use of activation, entrainment, or pace mapping with focal/linear ablation and targeting of late potentials. Epicardial VTs were targeted opposite normal endocardium in 10 patients (77%) and/or opposite ineffective endocardial ablation sites in 11 patients (85%). During 18+/-13 months, 10 of the 13 patients (77%) had no VT, with 2 patients having only a single VT at 2 and 38 months, respectively. CONCLUSIONS: Patients with right ventricular cardiomyopathy/dysplasia and VT after endocardial ablation have a more extensive epicardial area of electrogram abnormalities and frequently have basal right ventricular wall thickening. Epicardial substrate and VT mapping identifies targets, and ablation results in VT control.


Assuntos
Displasia Arritmogênica Ventricular Direita , Ablação por Cateter/métodos , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia , Adolescente , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Displasia Arritmogênica Ventricular Direita/patologia , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Eletrocardiografia , Feminino , Seguimentos , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Pericárdio/fisiopatologia , Cuidados Pré-Operatórios , Reoperação , Taquicardia Ventricular/etiologia , Resultado do Tratamento , Adulto Jovem
5.
J Cardiovasc Electrophysiol ; 17(10): 1074-9, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16879626

RESUMO

OBJECTIVE: To compare safety and efficacy of 8-mm versus cooled tip catheter in achieving electrical isolation (EI) of pulmonary veins (PV) for long-term control of atrial fibrillation (AF). BACKGROUND: There is paucity of studies comparing safety/efficacy of 8-mm and cooled tip catheters in patients undergoing AF ablation. METHODS AND RESULTS: This was a randomized and patient-blinded study. Subjects were followed by clinic visits (at 6 weeks and 6 months) and transtelephonic monitoring (3-week duration) done around each visit. Primary endpoints were: (1) long-term AF control (complete freedom and/or >90% reduction in AF burden on or off antiarrhythmic drugs at 6 months after a single ablation), and (2) occurrence of serious adverse events (cardiac tamponade, stroke, LA-esophageal fistula, and/or death). Eighty-two patients (age 56 +/- 9 years, 60 males, paroxysmal AF = 59) were randomized (42 patients to 8-mm tip and 40 patients to cooled tip). EI of PVs was achieved in shorter time by the 8-mm tip as compared with cooled tip catheter (40 +/- 23 minutes vs 50 +/- 30 minutes; P < 0.05) but long-term AF control was not different between the two (32 patients [78%] vs 28 patients [70%], respectively; P = NS). One serious adverse event occurred in each group (LA-esophageal fistula and stroke, respectively) and no significant PV stenosis was observed in either. CONCLUSION: EI of PVs using either 8-mm or cooled tip catheter results in long-term AF control in the majority after a single ablation procedure, with comparable efficacy and safety.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Crioterapia/instrumentação , Veias Pulmonares/cirurgia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Crioterapia/efeitos adversos , Crioterapia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Método Simples-Cego , Resultado do Tratamento
6.
Heart Rhythm ; 3(10): 1156-61, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17018343

RESUMO

BACKGROUND: Part of the esophagus is contiguous to the posterior wall (PW) of the left atrium (LA). Esophageal injury has occurred during LA ablation for atrial fibrillation (AF). The ability to identify the esophagus and monitor LAPW lesions with intracardiac echocardiography (ICE) has not been documented. METHODS: We report an index case of atrioesphageal fistula as a complication of transcatheter ablation of AF. After the index case, we retrospectively reviewed morphologic changes with radiofrequency (RF) delivered at LAPW during pulmonary vein (PV) electrical isolation using an 8-mm tip electrode (up to 70 W at a maximum of 50-52 degrees C for 60 seconds) or Chilli catheter (up to 50 W at a maximum of 40 degrees C for 60 seconds). ICE did not influence lesion application. After the index case, RF power was reduced at areas adjacent to the esophagus (8 mm/30-50 W at 50 degrees C or Chilli/40 W at a maximum of 38 degrees C). Duration of RF, 10-30 seconds, was titrated based on accelerated bubble formation or early echogenic lesion formation. RESULTS: The longitudinal extent of the contiguous LAPW-esophageal wall (length 18-59 mm) was identified in all 152 patients (ages 56 +/- 10 years, 117 men). Preablation LAPW (2.8 +/- 0.7 mm) and contiguous anterior esophageal wall (3.0 +/- 0.8 mm) thickness were noted. A total of 6 +/- 4.9 lesions/patient were delivered to the LAPW contiguous to the esophagus. Echogenic LAPW thickness increased to 7.5 +/- 2.1 mm (vs. 2.8 +/- 0.5 mm preablation) before the index case (n = 70 patients) and 4.7 +/- 1.6 mm (vs. 2.9 +/- 0.6 mm) after the index case (n = 67), with power reduction and titration of duration of energy delivery RF (P <.01) and PV isolation in all. CONCLUSIONS: The LAPW-esophageal region can be identified and monitored with ICE imaging during ablation procedures. RF lesions to the LAPW in PV isolation can produce dramatic morphologic changes immediately adjacent to the anterior esophageal wall. A reduction in power amount and duration as described coupled with online lesion monitoring to further titrate duration (<30 seconds) of power delivery decreases the depth of lesion formation and limits the risk of esophageal involvement.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia/métodos , Endossonografia , Doenças do Esôfago/prevenção & controle , Esôfago/diagnóstico por imagem , Átrios do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Doenças do Esôfago/etiologia , Esôfago/lesões , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/inervação , Humanos , Complicações Intraoperatórias/prevenção & controle , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
8.
J Am Coll Cardiol ; 43(10): 1861-7, 2004 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-15145112

RESUMO

OBJECTIVES: This study reports the incidence of, risk factors for, and management of left atrial (LA) thrombus documented by intracardiac echocardiography (ICE) during LA ablation for atrial fibrillation (AF). BACKGROUND: Thrombus formation is a risk associated with LA ablation procedures. METHODS: Intracardiac echocardiography imaging was performed in 232 patients (184 men, average age 55 +/- 11 years) with AF undergoing pulmonary vein ostial ablation. RESULTS: Anticoagulation (activated clotting time >250 s) was maintained after dual transseptal catheterization. Left atrial thrombus (n = 30) was observed in 24 of 232 patients (10.3%). Thrombi measured 12.9 +/- 11.1 mm (length) and 2.2 +/- 1.3 mm (width) and were attached to a sheath or mapping catheter. Most thrombi (27 of 30, 90%) were eliminated from the LA by withdrawal of the sheath and catheter into the right atrium (RA). Two thrombi became wedged in the interatrial septum and incompletely withdrawn into the RA, and one was recognized only on post-procedure review of ICE images. Patients with LA thrombus had an increased LA diameter (4.8 +/- 0.5 vs. 4.5 +/- 0.6 cm, p < 0.02), spontaneous echo contrast (67% vs. 3%, p < 0.0001) and a history of persistent AF (29% vs. 6%, p < 0.0002). Multivariate discriminant analysis showed that spontaneous echo contrast (f = 97.9, p < 0.0001) was the most important determinant of LA thrombus formation. No patient with LA thrombus suffered a clinical thromboembolic complication. CONCLUSIONS: Left atrial thrombus identified on ICE may occur during LA catheter ablation procedures despite aggressive anticoagulation. Spontaneous echo contrast may predict risk for LA thrombus formation. Left atrial thrombus may be successfully withdrawn into the RA under ICE imaging with no overt complications.


Assuntos
Ablação por Cateter/efeitos adversos , Cardiopatias/diagnóstico por imagem , Cardiopatias/epidemiologia , Trombose/diagnóstico por imagem , Trombose/epidemiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/terapia , Ecocardiografia/métodos , Feminino , Átrios do Coração , Cardiopatias/etiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Trombose/etiologia , Resultado do Tratamento
9.
J Am Soc Echocardiogr ; 18(1): 45-8, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15637488

RESUMO

OBJECTIVES: We sought to determine the prognostic use of inotropic contractile reserve on risk stratification and prognostication of women with peripartum cardiomyopathy. BACKGROUND: Peripartum cardiomyopathy is a rare disorder effecting women in their prime years of life. There appears to be an initial high-risk period with 25% to 50% of women dying within the first 3 months postpartum. Early risk stratification and prognostication are, thus, crucial. However, only limited data are available. METHODS: In all, 7 women (mean age 31.8 years) with peripartum cardiomyopathy and severe left ventricular (LV) dysfunction (mean LV ejection fraction [LVEF] 25.3 +/- 9.5%) were studied. Of these, 6 underwent dobutamine stress echocardiography at baseline and a follow-up resting echocardiogram at a mean of 4.7 +/- 0.9 months after initial presentation. Resting and peak inotropic contractile reserve, and follow-up LVEF, were computed. RESULTS: The mean LVEF improved significantly from baseline (25.3 +/- 9.5%) to maximal inotropic contractile reserve (53.8 +/- 12.6%) (P = .0004) and at follow-up (53.0 +/- 16.4%) (P = .006). Importantly, LVEF at maximal inotropic contractile reserve and at follow-up (5.6 months) did not differ significantly (P = .5). The mean LVEF at maximal inotropic contractile reserve correlated well with the follow-up (LVEF R = 0.79). However, the baseline LVEF did not correlate with follow-up LVEF (P = not significant). CONCLUSIONS: In patients presenting with peripartum cardiomyopathy, inotropic contractile reserve during dobutamine stress echocardiography accurately correlates with subsequent recovery of LV function and confers a benign prognosis.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Ecocardiografia sob Estresse , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Adulto , Cardiomiopatias/fisiopatologia , Feminino , Humanos , Contração Miocárdica , Gravidez , Complicações Cardiovasculares na Gravidez/fisiopatologia , Prognóstico , Medição de Risco , Disfunção Ventricular Esquerda/fisiopatologia
12.
Heart Rhythm ; 1(3): 262-7, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15851167

RESUMO

OBJECTIVES: The aim of this study was to determine the effect of electrical isolation of pulmonic vein (PV) on flow velocity. BACKGROUND: We report our experience with electrical isolation of PV by partial circumferential ablation and its effect on ostial peak flow velocity as assessed by phased-array ultrasound catheter imaging. METHODS: Sixty-two patients participated in the study. Magnetic electroanatomic mapping, ultrasound catheter imaging, and Lasso mapping catheter were used. Electrical isolation was achieved by delivering radiofrequency ablation (RFA) lesions proximal to Lasso mapping catheter bipoles showing PV entry. Following this, the number of RFA lesions/PV and their segment-wise distribution (maximum 4/PV) were assessed. RESULTS: Fifty right superior, 51 left superior, 32 left inferior, and 17 right inferior PVs were isolated. RFA involved 4 segments in 42 PVs, 3 segments in 61 PVs, and 90% reduction in AF burden, either with or without previously ineffective antiarrhythmic agents, was achieved in 54 patients (87%). CONCLUSIONS: In the majority of PVs (72%), electrical isolation can be achieved by partial circumferential ablation (targeting

Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Fluxo Sanguíneo Regional/fisiologia , Resultado do Tratamento , Ultrassonografia
13.
J Am Soc Echocardiogr ; 15(10 Pt 2): 1301-8, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12411921

RESUMO

BACKGROUND: AcuNav ultrasound catheter (UC) (10F, 5.5-10 MHz) has unique advantages for left heart imaging with its 4-way tip flexible maneuverability, maximal 16-cm intracardiac imaging depth, and Doppler and color flow imaging capability. METHODS: We assessed the initial use of this UC in 40 consecutive patients (34 men; age 53 +/- 11 years old). All patients were also undergoing transseptal catheterization for percutaneous catheter mapping and ablation of either left atrium (focal initiated atrial arrhythmia/fibrillation, n = 32) or left ventricle (ventricular tachycardia, n = 4), or transcatheter atrial septal defect closure (n = 4) procedures. During each procedure, the UC was placed in the right atrium, superior vena cava, or right ventricular inflow/outflow tract. RESULTS: In all patients, UC successfully guided transseptal catheterization and provided imaging of normal or aberrant anatomy of the right/left atrial (interatrial septum, fossa ovalis, appendages, 4 pulmonary vein ostia) and right/left ventricular (valves and papillary muscles) structures. UC was important in early identification procedure complications, including pericardial effusion (n = 2, detected before systematic hemodynamic deterioration) and thrombus formation on sheaths deployed in the right atrium (n = 9) and left atrium (n = 2, early elimination with management of the sheath). With Doppler and color flow imaging, UC provided effective monitoring of increased flow velocity of all ablated pulmonary vein ostia and detection of patent foramen ovale (n = 6) or residual trivial/small atrial septal defect posttransseptal catheterization (n = 2). UC was also used to successfully image and guide transcatheter closure of atrial septal defect with positioning of the cardioseal septal occluder (Nitinol Medical Technologies Inc, Boston, Mass) and color Doppler imaging of no significant residual shunt. CONCLUSION: AcuNav UC with Doppler and color flow imaging has significant use, especially during left heart ablation. Uses include guidance of transseptal and mapping/ablation catheters and closure devices, and prompt diagnosis of cardiac complications.


Assuntos
Cateterismo Cardíaco , Ablação por Cateter , Diagnóstico por Imagem/instrumentação , Cardiopatias/diagnóstico , Cardiopatias/cirurgia , Cuidados Intraoperatórios , Ultrassonografia de Intervenção/instrumentação , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Cardiopatias/fisiopatologia , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Comunicação Interatrial/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Transdutores , Resultado do Tratamento
14.
J Interv Card Electrophysiol ; 10(3): 265-9, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15133366

RESUMO

INTRODUCTION: Application of radiofrequency energy at pulmonary vein (PV) ostium during focal atrial fibrillation (AF) ablation procedures increases flow velocity due to PV narrowing. Factors unrelated to ablation that effect PV flow velocity have not been described. AIMS OF THE STUDY: The purpose of this study was to evaluate, using intracardiac echocardiography (ICE) imaging, the effect of isoproterenol (ISO) and heart rate (HR) on PV flow velocity Pre- and Post-ablation. METHODS AND RESULTS: In 31 patients with AF undergoing LA-PV ostial ablation involving at least one PV ostium, an ICE catheter was placed in the RA to image and detect PV flow. PV ostial peak velocity was assessed in sinus rhythm Pre-, Post-ablation, during and after ISO (up to 20 microg/min). To separate HR versus ISO effect, PV velocity was measured during atrial pacing (after HR returned to baseline) at pacing rate matching HR with ISO. PV ostial velocity was assessed with ISO and pacing in 30 non-ablated and 33 ablated PVs. Ostial velocities of non-ablated PVs during ISO infusion (117 +/- 42 cm/s) were greater ( p < 0.03) than those during atrial pacing (78 +/- 26 cm/s) at matched HR (116 +/- 20, range 92-150 bpm). Ostial PV flow velocities of ablated PVs increased from 59 +/- 17 (30-95) cm/s Pre- to 95 +/- 25 (58-136) cm/s Post-ablation. During ISO infusion PV flow velocities in ablated PVs (118 +/- 34 cm/s) were also greater ( p < 0.03) than those during atrial pacing (96 +/- 37 cm/s) at matched HR (116 +/- 14, range 92-130 bpm). Atrial pacing alone produced no significant difference in PV flow velocities measured Pre- or Postablation. CONCLUSION: ISO appears to increase ostial flow velocity of ablated and non-ablated PVs independent of HR effect. These effects are important to recognize when PV velocity is used as an index for interpreting the impact of PV ostial lesions on functionally significant PV narrowing.


Assuntos
Agonistas Adrenérgicos beta/uso terapêutico , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Broncodilatadores/uso terapêutico , Ablação por Cateter , Frequência Cardíaca/efeitos dos fármacos , Isoproterenol/uso terapêutico , Veias Pulmonares/efeitos dos fármacos , Veias Pulmonares/fisiopatologia , Adulto , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Ecocardiografia Doppler em Cores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Resultado do Tratamento
15.
J Interv Card Electrophysiol ; 6(3): 225-31, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12154324

RESUMO

INTRODUCTION: Limitations in lesion volume and particularly lesion depth may negatively effect the efficacy of catheter ablation procedures using radiofrequency energy. This study evaluated the safety and efficacy of myocardial ablation using direct intramural injection of ethanol with a novel injection catheter system. METHODS: Left ventricular lesions were performed in 9 male swine (80-85 pounds); two animals were studied 6 weeks following anterior infarction produced by agarose gel embolization. An 8 Fr deflectable catheter equipped with a 27 gauge adjustable depth, retractable needle was directed to the LV using a retrograde aortic approach. Lesion deployment was guided by fluoroscopy and intracardiac echocardiography (ICE). Lesion characteristics were assessed with ICE imaging and pathologic analysis. RESULTS: Ethanol lesions were confined to the tissue directly adjacent to the injection port. Lesions were intramural with no evidence of overlying thrombus. Lesions delivered with a single port injection needle in normal myocardium (n = 24) averaged 1910 +/- 1066 mm(3) with a depth of 8.9 +/- 3.3 mm. Lesions directed to infarct border zones (n = 4) averaged 929 +/- 882 mm(3) with a depth of 4.3 +/- 2.8 mm. Lesions were immediately evident on ICE imaging, and were visualized by increased echo density and tissue swelling. Pathological analysis revealed homogenous lesions with intramural hemorrhage and contraction band necrosis. CONCLUSIONS: Myocardial catheter ablation using direct ethanol injection is feasible, and relatively large and deep intramural lesions can be delivered, even in the infarct border zone. This technique may prove useful in ablation of arrhythmia substrates that are deep to the endocardial surface.


Assuntos
Ablação por Cateter/métodos , Ecocardiografia/métodos , Etanol/farmacologia , Disfunção Ventricular Esquerda/cirurgia , Análise de Variância , Animais , Modelos Animais de Doenças , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Imuno-Histoquímica , Injeções Intralesionais , Masculino , Infarto do Miocárdio/fisiopatologia , Miocárdio/patologia , Probabilidade , Sensibilidade e Especificidade , Suínos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Disfunção Ventricular Esquerda/diagnóstico por imagem
16.
Echocardiography ; 15(7): 661-664, 1998 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11175096

RESUMO

Intracardiac echocardiography (ICE) with lower frequency is a new imaging modality. We present the case of a patient with dilated cardiomyopathy and recurrent supraventricular tachycardia due to a right posterolateral accessory pathway. ICE imaging was performed using a 9-MHz (9-Fr) catheter positioned in the right atrium and guided precise catheter localization at the lateral tricuspid annulus where the bypass tract was located, which facilitated successful radiofrequency ablation. In addition, ICE imaging detected anatomic abnormalities, including localized pericardial effusion and torn tricuspid chordae tendineae, which were all identified at the onset of the procedure. The effusions remained stable during imaging monitoring throughout the procedure, which helped reassure us that these abnormalities were not procedure related. In summary, ICE imaging may significantly improve procedural efficacy in selected catheter ablation procedure and help detect anatomic abnormalities, procedural complications, or both.

17.
Echocardiography ; 14(2): 135-148, 1997 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11174934

RESUMO

Transthoracic echocardiographic imaging has been difficult to attain in the swine model. This study: (1) compares multiplane transesophageal echocardiography (TEE) with single plane TEE and intracardiac catheter echocardiography (ICE) for imaging of the swine cardiovascular system; and (2) defines normal values using these techniques in a closed chest large swine model (n = 24, body weight 50-114 kg). Multiplane TEE increased success rate over the single plane (the variable plane array only at 0 degrees ) TEE (P < 0.01) for imaging the left ventricular (LV) long-axis view (100% vs 50%), LV outflow tract (100% vs 33%), right atrium and its appendage (79% vs 33%), ascending aorta (100% vs 58%), and aortic arch (100% vs 17%). TEE-derived normal values at end-diastole (ED) and end-systole (ES) were: LV internal diameter (ID) = 49 +/- 3 mm (ED) and 33 +/- 4 mm (ES); LV wall thickness = 7 +/- 1 mm (ED); right ventricular (RV) ID = 24 +/- 4 mm (ED); RV wall thickness = 4 +/- 2 mm (ED); left atrial ID = 48 +/- 6 mm (ES); aortic root ID = 26 +/- 3 mm (ES); LV volume = 157 +/- 49 ml (ED) and 57 +/- 22 ml (ES). Baseline LV ejection fraction (64% +/- 6%), Doppler-derived stroke volume (86 +/- 14 ml), and cardiac index (107 ml/min per kg) were determined. Basal normal values, except for an elevated cardiac index in swine, are comparable to those reported for human adults. Multiplane TEE provided better overall cardiac imaging than did single plane TEE. ICE provided higher resolution imaging of individual cardiac chambers and structures when the ultrasound catheter was introduced into the right or left heart, but whole heart imaging was limited by ultrasound penetration at 12.5 MHz. Normal indices of chamber size and function provide a reference for the physiological significance of induced pathological states in this relevant animal model.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa