Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Circulation ; 149(17): 1341-1353, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38235580

RESUMO

BACKGROUND: Cardiolipin is a mitochondrial-specific phospholipid that maintains integrity of the electron transport chain (ETC) and plays a central role in myocardial ischemia/reperfusion injury. Tafazzin is an enzyme that is required for cardiolipin maturation. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) use to provide hemodynamic support for acute myocardial infarction has grown exponentially, is associated with poor outcomes, and is under active clinical investigation, yet the mechanistic effect of VA-ECMO on myocardial damage in acute myocardial infarction remains poorly understood. We hypothesized that VA-ECMO acutely depletes myocardial cardiolipin and exacerbates myocardial injury in acute myocardial infarction. METHODS: We examined cardiolipin and tafazzin levels in human subjects with heart failure and healthy swine exposed to VA-ECMO and used a swine model of closed-chest myocardial ischemia/reperfusion injury to evaluate the effect of VA-ECMO on cardiolipin expression, myocardial injury, and mitochondrial function. RESULTS: Cardiolipin and tafazzin levels are significantly reduced in the left ventricles of individuals requiring VA-ECMO compared with individuals without VA-ECMO before heart transplantation. Six hours of exposure to VA-ECMO also decreased left ventricular levels of cardiolipin and tafazzin in healthy swine compared with sham controls. To explore whether cardiolipin depletion by VA-ECMO increases infarct size, we performed left anterior descending artery occlusion for a total of 120 minutes followed by 180 minutes of reperfusion in adult swine in the presence and absence of MTP-131, an amphipathic molecule that interacts with cardiolipin to stabilize the inner mitochondrial membrane. Compared with reperfusion alone, VA-ECMO activation beginning after 90 minutes of left anterior descending artery occlusion increased infarct size (36±8% versus 48±7%; P<0.001). VA-ECMO also decreased cardiolipin and tafazzin levels, disrupted mitochondrial integrity, reduced electron transport chain function, and promoted oxidative stress. Compared with reperfusion alone or VA-ECMO before reperfusion, delivery of MTP-131 before VA-ECMO activation reduced infarct size (22±8%; P=0.03 versus reperfusion alone and P<0.001 versus VA-ECMO alone). MTP-131 restored cardiolipin and tafazzin levels, stabilized mitochondrial function, and reduced oxidative stress in the left ventricle. CONCLUSIONS: We identified a novel mechanism by which VA-ECMO promotes myocardial injury and further identify cardiolipin as an important target of therapy to reduce infarct size and to preserve mitochondrial function in the setting of VA-ECMO for acute myocardial infarction.

2.
JACC Basic Transl Sci ; 8(7): 769-780, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37547066

RESUMO

Whether extracorporeal membrane oxygenation (ECMO) with Impella, known as EC-Pella, limits cardiac damage in acute myocardial infarction remains unknown. The authors now report that the combination of transvalvular unloading and ECMO (EC-Pella) initiated before reperfusion reduced infarct size compared with ECMO alone before reperfusion in a preclinical model of acute myocardial infarction. EC-Pella also reduced left ventricular pressure-volume area when transvalvular unloading was applied before, not after, activation of ECMO. The authors further observed that EC-Pella increased cardioprotective signaling but failed to rescue mitochondrial dysfunction compared with ECMO alone. These findings suggest that ECMO can increase infarct size in acute myocardial infarction and that EC-Pella can mitigate this effect but also suggest that left ventricular unloading and myocardial salvage may be uncoupled in the presence of ECMO in acute myocardial infarction. These observations implicate mechanisms beyond hemodynamic load as part of the injury cascade associated with ECMO in acute myocardial infarction.

3.
J Cardiovasc Transl Res ; 15(2): 207-216, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33782857

RESUMO

New mechanistic insight into how the kidney responds to cardiac injury during acute myocardial infarction (AMI) is required. We hypothesized that AMI promotes inflammation and matrix metalloproteinase-9 (MMP9) activity in the kidney and studied the effect of initiating an Impella CP or veno-arterial extracorporeal membrane oxygenation (VA-ECMO) before coronary reperfusion during AMI. Adult male swine were subjected to coronary occlusion and either reperfusion (ischemia-reperfusion; IR) or support with either Impella or VA-ECMO before reperfusion. IR and ECMO increased while Impella reduced levels of MMP-9 in the myocardial infarct zone, circulation, and renal cortex. Compared to IR, Impella reduced myocardial infarct size and urinary KIM-1 levels, but VA-ECMO did not. IR and VA-ECMO increased pro-fibrogenic signaling via transforming growth factor-beta and endoglin in the renal cortex, but Impella did not. These findings identify that AMI increases inflammatory activity in the kidney, which may be attenuated by Impella support.


Assuntos
Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Infarto do Miocárdio , Animais , Masculino , Metaloproteinase 9 da Matriz , Choque Cardiogênico , Suínos
4.
J Am Coll Cardiol ; 76(6): 684-699, 2020 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-32762903

RESUMO

BACKGROUND: Myocardial damage due to acute ST-segment elevation myocardial infarction (STEMI) remains a significant global health problem. New approaches to limit myocardial infarct size and reduce progression to heart failure after STEMI are needed. Mechanically reducing left ventricular (LV) workload (LV unloading) before coronary reperfusion is emerging as a potential approach to reduce infarct size. OBJECTIVES: Given the central importance of mitochondria in reperfusion injury, we hypothesized that compared with immediate reperfusion (IR), LV unloading before reperfusion improves myocardial energy substrate use and preserves mitochondrial structure and function. METHODS: To explore the effect of LV unloading duration on infarct size, we analyzed data from the STEMI-Door to Unload (STEMI-DTU) trial and then tested the effect of LV unloading on ischemia and reperfusion injury, cardiac metabolism, and mitochondrial function in swine models of acute myocardial infarction. RESULTS: The duration of LV unloading before reperfusion was inversely associated with infarct size in patients with large anterior STEMI. In preclinical models, LV unloading reduced the expression of hypoxia-sensitive proteins and myocardial damage due to ischemia alone. LV unloading with a transvalvular pump (TV-P) but not with venoarterial extracorporeal membrane oxygenation (ECMO) reduced infarct size. Using unbiased and blinded metabolic profiling, TV-P improved myocardial energy substrate use and preserved mitochondrial structure including cardiolipin content after reperfusion compared with IR or ECMO. Functional testing in mitochondria isolated from the infarct zone showed an intact mitochondrial structure including cardiolipin content, preserved activity of the electron transport chain including mitochondrial complex I, and reduced oxidative stress with TV-P-supported reperfusion but not with IR or ECMO. CONCLUSIONS: These novel findings identify that transvalvular unloading limits ischemic injury before reperfusion, improves myocardial energy substrate use, and preserves mitochondrial structure and function after reperfusion.


Assuntos
Reperfusão Miocárdica/métodos , Cuidados Pré-Operatórios/métodos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Animais , Valvas Cardíacas , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Masculino , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Suínos
5.
J Cardiovasc Transl Res ; 13(2): 151-157, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31773461

RESUMO

Congestion is a major determinant of clinical outcomes in heart failure (HF). We compared the acute hemodynamic effects of occlusion of the superior (SVC) versus the inferior vena cava (IVC) and tested a novel SVC occlusion system in swine models of HF. IVC occlusion acutely reduced left ventricular (LV) systolic and diastolic pressures, LV volumes, cardiac output (CO), and mean arterial pressure (MAP). SVC occlusion reduced LV diastolic pressure and volumes without affecting CO or MAP. The preCARDIA system is a balloon occlusion catheter and pump console which enables controlled delivery and removal of fluid into the occlusion balloon. At 6, 12, and 18 h, SVC therapy with the system provided a sustained reduction in cardiac filling pressures with stable CO and MAP. Intermittent SVC occlusion is a novel approach to reduce biventricular filling pressures in HF. The VENUS-HF trial will test the safety and feasibility of SVC therapy in HF.


Assuntos
Oclusão com Balão , Insuficiência Cardíaca/terapia , Veia Cava Superior/fisiopatologia , Função Ventricular Esquerda , Pressão Ventricular , Animais , Pressão Arterial , Débito Cardíaco , Modelos Animais de Doenças , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Masculino , Infarto do Miocárdio/complicações , Infarto do Miocárdio/fisiopatologia , Estudo de Prova de Conceito , Sus scrofa , Fatores de Tempo , Pressão Venosa
6.
J Thromb Thrombolysis ; 28(4): 394-400, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19399370

RESUMO

Heparin and low-molecular weight heparin (LMWH) are complex, heterogeneous polysaccharides used in the treatment of arterial and venous thrombosis. M118 is a novel LMWH with low polydispersity and pronounced anti-Xa and anti-thrombin (IIa) activity as compared to current LMWHs. To determine if M118 is effective in preventing thrombosis in the setting of a vascular plaque, apolipoprotein E knockout mice fed a high fat diet were injected with M118, enoxaparin, unfractionated heparin, or saline control and examined for arterial thrombosis using a rose bengal laser induced carotid artery injury model. M118 significantly increased the time to occlusion as compared to control and unfractionated heparin but not compared to enoxaparin although fewer M118 treated animals had any vascular occlusion present at the time of protocol completion. Platelet-neutrophil aggregates were studied by flow cytometry and were found to be decreased with M118 as compared to enoxaparin. This is the first published report examining M118, a novel LMWH designed to have low polydispersity and enhanced anticoagulant activity. In an animal model of vascular plaque, M118 is a potent inhibitor of arterial thrombosis and, despite lower in vivo anti-Xa and anti-IIa activity levels, M118 was superior to UFH in the prevention of arterial thrombosis.


Assuntos
Anticoagulantes/uso terapêutico , Apolipoproteínas E/deficiência , Modelos Animais de Doenças , Heparina de Baixo Peso Molecular/análogos & derivados , Heparina de Baixo Peso Molecular/uso terapêutico , Tromboembolia/prevenção & controle , Animais , Anticoagulantes/química , Anticoagulantes/farmacocinética , Apolipoproteínas E/genética , Feminino , Heparina de Baixo Peso Molecular/farmacocinética , Masculino , Camundongos , Camundongos Knockout , Tromboembolia/tratamento farmacológico , Tromboembolia/genética , Trombose/tratamento farmacológico , Trombose/genética , Trombose/prevenção & controle , Distribuição Tecidual/efeitos dos fármacos , Distribuição Tecidual/genética
7.
J Cardiovasc Transl Res ; 12(2): 87-94, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31016553

RESUMO

Acute myocardial infarction (AMI) remains a leading cause of morbidity and mortality. Pioneering preclinical work reported by Peter Maroko and Eugene Braunwald in 1971 identified oxygen supply and demand are primary determinants of myocardial infarct size in the setting of a heart attack. Since the 1950s, advances in mechanical engineering led to the development of short-term circulatory support devices that range from pulsatile to continuous flow pumps. The primary objective of these pumps is to reduce native heart work, enhance coronary blood flow, and sustain systemic perfusion. Whether these pumps could reduce myocardial infarct size in the setting of AMI became an intense focus for preclinical investigation with variable animal models, experimental algorithms, and pump platforms being tested. In this review, we discuss the design of these preclinical studies and the evolution of mechanical support platforms and attempt to translate these experimental methods into clinical trials.


Assuntos
Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar , Infarto do Miocárdio/terapia , Traumatismo por Reperfusão Miocárdica/prevenção & controle , Reperfusão Miocárdica , Miocárdio/metabolismo , Consumo de Oxigênio , Implantação de Prótese/instrumentação , Função Ventricular Esquerda , Animais , Insuficiência Cardíaca/metabolismo , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Infarto do Miocárdio/metabolismo , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Reperfusão Miocárdica/efeitos adversos , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Traumatismo por Reperfusão Miocárdica/fisiopatologia , Miocárdio/patologia , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Recuperação de Função Fisiológica , Fatores de Risco , Resultado do Tratamento
8.
J Am Heart Assoc ; 8(22): e013586, 2019 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-31698989

RESUMO

Background Unloading the left ventricle and delaying reperfusion reduces infarct size in preclinical models of acute myocardial infarction. We hypothesized that a potential explanation for this effect is that left ventricular (LV) unloading before reperfusion increases collateral blood flow to ischemic myocardium. Methods and Results Acute myocardial infarction was induced by balloon occlusion of the left anterior descending artery for 120 minutes in adult swine, followed by reperfusion for 180 minutes. After 90 minutes of occlusion, animals were assigned to 30 minutes of continued occlusion (n=6) or to 30 minutes of support with either an Impella CP (n=4) or venoarterial extracorporeal membrane oxygenation (n=5) with persistent occlusion. The primary end point was measures of microcirculatory blood flow including the collateral flow index (CFI) during left anterior descending artery occlusion as (Pw-RA)/(Pa-RA), where Pa, Pw, and RA are aortic, coronary wedge, and right atrial pressure, respectively. Infarct size was quantified using triphenyltetrazolium chloride. Compared with continued occlusion, Impella, not venoarterial extracorporeal membrane oxygenation, reduced infarct size relative to the area at risk. Before reperfusion, Impella reduced LV stroke work by 25% and increased the CFI by 75%, but venoarterial extracorporeal membrane oxygenation did not. Among all groups, the change in CFI between 90 and 120 minutes correlated inversely with the change in LV stroke work (r2=0.44, P=0.01) and infarct size (r2=0.41, P=0.02). Conclusions We report for the first time that 30 minutes of LV unloading during coronary occlusion increases the CFI, which correlates inversely with LV stroke work and infarct size. Venoarterial extracorporeal membrane oxygenation failed to increase the CFI and did not reduce infarct size.


Assuntos
Circulação Assistida/métodos , Circulação Colateral , Circulação Coronária , Oxigenação por Membrana Extracorpórea/métodos , Infarto do Miocárdio/patologia , Traumatismo por Reperfusão Miocárdica/patologia , Reperfusão Miocárdica , Miocárdio/patologia , Animais , Cateterismo Cardíaco , Cateterismo de Swan-Ganz , Vasos Coronários , Coração Auxiliar , Masculino , Microcirculação , Traumatismo por Reperfusão Miocárdica/terapia , Pressão , Índice de Gravidade de Doença , Sus scrofa , Função Ventricular Esquerda
10.
F1000Res ; 72018.
Artigo em Inglês | MEDLINE | ID: mdl-30542612

RESUMO

Heart failure is a major cause of global morbidity and mortality. Acute myocardial infarction (AMI) is a primary cause of heart failure due in large part to residual myocardial damage despite timely reperfusion therapy. Since the 1970's, multiple preclinical laboratories have tested whether reducing myocardial oxygen demand with a mechanical support pump can reduce infarct size in AMI. In the past decade, this hypothesis has been studied using contemporary circulatory support pumps. We will review the most recent series of preclinical studies in the field which led to the recently completed Door to Unload ST-segment Elevation Myocardial Infarction (DTU-STEMI) safety and feasibility pilot trial.


Assuntos
Coração Auxiliar/tendências , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Pesquisa Translacional Biomédica/métodos , Animais , Humanos , Recuperação de Função Fisiológica , Pesquisa Translacional Biomédica/tendências , Função Ventricular Esquerda
11.
Comp Med ; 68(1): 48-55, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-29460721

RESUMO

Currently available animal models for delivery of drug capsules and pharmacokinetic testing are limited by either intersubject variability in gastric emptying time or the need to sedate animals when using targeted delivery methods of drug capsules. With the increasing development of large-molecule biologics, better in vivo models for testing the pharmacokinetics of capsule-delivered drugs are urgently needed. To this end, we made engineering modifications to an existing bovine surgical cannula device, successfully implanted this modified cannula into pigs, and delivered drug capsules directly to the proximal duodenum. In our porcine model, capsule insertion and serial blood samples were all acquired without the use of sedatives. Furthermore, we were able to maintain cannulated pigs for weekly pharmacokinetic testing for more than 18 mo, with minimal postoperative complications. This study demonstrates a novel and effective porcine model of sedation-free drug delivery and blood collection that eliminates inconsistencies associated with models that require either gastric emptying or animal sedation.


Assuntos
Cateterismo/veterinária , Duodeno/cirurgia , Sus scrofa , Dispositivos de Acesso Vascular/veterinária , Animais , Cateterismo/efeitos adversos , Cateterismo/métodos , Vias de Administração de Medicamentos/veterinária , Feminino , Dispositivos de Acesso Vascular/efeitos adversos
12.
Circ Heart Fail ; 11(8): e005115, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30354560

RESUMO

BACKGROUND: Acute heart failure refractory to medical therapy is a major cause of morbidity and mortality. The Aortix device (Procyrion Inc) is a percutaneously delivered entrainment pump positioned in the descending aorta. METHODS AND RESULTS: Using the newest generation Aortix device in 8 adult male Yorkshire swine, we tested the hypothesis that positioning in the abdominal aorta may provide superior hemodynamic effects than thoracic positioning in a swine model of postinfarct left ventricular injury.Abdominal activation generated significantly larger transaortic gradients (proximal minus distal mean aortic pressures) than thoracic positioning at all pump speeds. Compared with baseline values, activation in the abdominal, not thoracic, position significantly increased cardiac output, reduced arterial elastance, and systemic vascular resistance at low speeds. Compared with baseline values, abdominal activation also increased transpulmonary pressure gradients at medium and high speed, which was driven by trends toward higher mean pulmonary artery pressure and lower pulmonary capillary wedge pressure. CONCLUSIONS: This is the first report to determine that in contrast to thoracic positioning, abdominal positioning of the newest generation Aortix device reduces left ventricular afterload and increases cardiac output at low speeds. These findings have potentially important implications for the design of early clinical studies by suggesting that device position and speed are major determinants of improved hemodynamic efficacy.


Assuntos
Aorta Abdominal/fisiopatologia , Débito Cardíaco , Insuficiência Cardíaca/terapia , Coração Auxiliar , Implantação de Prótese/métodos , Função Ventricular Esquerda , Animais , Aorta Torácica/fisiopatologia , Pressão Arterial , Modelos Animais de Doenças , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Masculino , Desenho de Prótese , Recuperação de Função Fisiológica , Sus scrofa , Fatores de Tempo
13.
J Am Coll Cardiol ; 72(5): 501-514, 2018 07 31.
Artigo em Inglês | MEDLINE | ID: mdl-30049311

RESUMO

BACKGROUND: Heart failure after an acute myocardial infarction (AMI) is a major cause of morbidity and mortality worldwide. We recently reported that activation of a transvalvular axial-flow pump in the left ventricle and delaying myocardial reperfusion, known as primary unloading, limits infarct size after AMI. The mechanisms underlying the cardioprotective benefit of primary unloading and whether the acute decrease in infarct size results in a durable reduction in LV scar and improves cardiac function remain unknown. OBJECTIVES: This study tested the importance of LV unloading before reperfusion, explored cardioprotective mechanisms, and determined the late-term impact of primary unloading on myocardial function. METHODS: Adult male swine were subjected to primary reperfusion or primary unloading after 90 min of percutaneous left anterior descending artery occlusion. RESULTS: Compared with primary reperfusion, 30 min of LV unloading was necessary and sufficient before reperfusion to limit infarct size 28 days after AMI. Compared with primary reperfusion, primary unloading increased expression of genes associated with cellular respiration and mitochondrial integrity within the infarct zone. Primary unloading for 30 min further reduced activity levels of proteases known to degrade the cardioprotective cytokine, stromal-derived factor (SDF)-1α, thereby increasing SDF-1α signaling via reperfusion injury salvage kinases, which limits apoptosis within the infarct zone. Inhibiting SDF-1α activity attenuated the cardioprotective effect of primary unloading. Twenty-eight days after AMI, primary unloading reduced LV scar size, improved cardiac function, and limited expression of biomarkers associated with heart failure and maladaptive remodeling. CONCLUSIONS: The authors report for the first time that first mechanically reducing LV work before coronary reperfusion with a transvalvular pump is necessary and sufficient to reduce infarct size and to activate a cardioprotective program that includes enhanced SDF-1α activity. Primary unloading further improved LV scar size and cardiac function 28 days after AMI.


Assuntos
Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Reperfusão Miocárdica/métodos , Recuperação de Função Fisiológica/fisiologia , Função Ventricular Esquerda/fisiologia , Animais , Masculino , Reperfusão Miocárdica/tendências , Suínos
16.
ASAIO J ; 61(3): 301-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25485565

RESUMO

Our objective was to examine the hemodynamic effects of a trans-aortic axial flow catheter (Impella CP) in the left ventricle (LV) versus left atrial (LA) to femoral artery bypass using a centrifugal pump (TandemHeart: TH) in a bovine model of acute LV injury. In three male calves, we performed sequential activation of a CP then TH device in each animal. After 60 minutes of left anterior descending artery ligation, a CP was activated at maximal power. The CP was then removed and the TH activated at 5,500 then a maximum of 7,500 rotations per minute (RPM). The CP generated a maximum 3.1 ± 0.2 L/minute (LPM) of flow, whereas the TH at 5,500 and 7,500 RPM generated 3.1 ± 0.4 and 4.4 ± 0.3 LPM. At 3.1 LPM, the CP and TH reduced LV stroke work (LVSW) similarly. The TH reduced stroke volume, whereas the CP did not. The CP reduced end-systolic pressure, whereas the TH did not. At a maximum flow of 4.4 LPM, the TH provided a greater reduction in LVSW than maximal CP activation. This is the first report to compare the hemodynamic effects of trans-aortic LV unloading versus LA-to-femoral artery (FA) bypass.


Assuntos
Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Hemodinâmica/fisiologia , Infarto do Miocárdio/fisiopatologia , Função Ventricular Esquerda/fisiologia , Animais , Bovinos , Modelos Animais de Doenças , Masculino
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa