Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Clin Transplant ; 30(9): 1152-8, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27412378

RESUMO

After bilateral lung and heart-lung transplantation in adults with pulmonary hypertension, hemodynamic and oxygenation deficiencies are life-threatening complications that are increasingly managed with extracorporeal life support (ECLS). The primary aim of this retrospective study was to assess 30-day and 1-year survival rates in patients managed with vs without post-operative venoarterial ECLS in 2008-2013. The secondary endpoints were the occurrence rates of nosocomial infection, bleeding, and acute renal failure. Of the 93 patients with pulmonary hypertension who received heart-lung (n=29) or bilateral lung (n=64) transplants, 28 (30%) required ECLS a median of 0 [0-6] hours after surgery completion and for a median of 3.0 [2.0-8.5] days. Compared to ECLS patients, controls had higher survival at 30 days (95.0% vs 78.5%; P=.02) and 1 year (83% vs 64%; P=.005), fewer nosocomial infections (48% vs 79%; P=.0006), and fewer bleeding events (17% vs 43%; P=.008). The need for renal replacement therapy was not different between groups (11% vs 17%; P=.54). Venoarterial ECLS is effective in treating pulmonary graft dysfunction with hemodynamic failure after heart-lung or bilateral lung. However, ECLS use was associated with higher rates of infection and bleeding.


Assuntos
Circulação Extracorpórea/métodos , Oxigenação por Membrana Extracorpórea/métodos , Transplante de Coração-Pulmão , Hemodinâmica/fisiologia , Hipertensão Pulmonar/cirurgia , Adulto , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
2.
Am J Respir Crit Care Med ; 172(10): 1276-82, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16126933

RESUMO

RATIONALE AND OBJECTIVES: The respective influence on the incidence of ventilator-associated pneumonia of currently available systems used for warming and humidifying the gases delivered to mechanically ventilated patients, that is, heated humidifiers and heat and moisture exchanger filters, remains controversial. METHODS: We addressed this question in a multicenter randomized study comparing heated humidifiers (with heated circuits) and filters in an unselected population of 369 intensive care patients receiving mechanical ventilation for more than 48 h. MAIN MEASUREMENTS AND RESULTS: The diagnosis of pneumonia was confirmed according to strict microbiologic criteria. There was no difference in pneumonia rate between the two groups (53 of 184 [28.8%] versus 47 of 185 [25.4%] for humidifiers versus filters; p = 0.48), or in the incidence density of pneumonia (27.4/1,000 ventilatory days versus 25.3/1,000 ventilatory days for humidifiers versus filters; p = 0.76). The mean duration of mechanical ventilation did not differ between the two groups (14.9 +/- 15.1 versus 13.5 +/- 16.3 days for humidifiers versus filters, p = 0.36). Endotracheal tube occlusion occurred, respectively, in five patients and one patient in the humidifier and filter groups (p = 0.12). Intensive care mortality was identical in the two groups (about 33%). CONCLUSION: These results suggest that both heated humidifiers and heat and moisture exchanger filters can be used with no significant impact on the incidence of ventilator-associated pneumonia and that other criteria may justify their choice.


Assuntos
Pneumonia/epidemiologia , Respiração Artificial/efeitos adversos , Filtração , Temperatura Alta , Humanos , Umidade , Intubação Intratraqueal , Modelos Logísticos , Análise Multivariada , Pneumonia/etiologia , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa