Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Interv Cardiol ; 29(2): 208-15, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26927945

RESUMO

OBJECTIVES: To evaluate the mid-term outcomes after percutaneous closure of the secundum atrial septal defects (ASD) using the Figulla-Occlutech device (FOD). BACKGROUND: Transcatheter closure has become the method of choice for most patients with ASD. Although the FOD may have some advantageous characteristics there is a paucity of data on later outcomes after the use of this relatively new device. METHODS: Observational, single arm study including 200 non-consecutive patients who underwent ASD closure between 04/09 and 07/15 in 2 centers. Device performance, deployment technique, and immediate and mid-term outcomes were assessed. RESULTS: Median age and weight were 24 years (4-72) and 58 kg (15-92), respectively. Single defects were observed in 171 patients (median size of 19 mm). The remainder had multiple or multifenestrated defects. Implantation of FOD (median size of 24 mm) was successful in all (99%), but 2 patients (1 with deficient postero-inferior rim; 1 with a large ASD for the size of the child). Embolization with device retrieval occurred in 2 (1%). Median follow-up of 36 months was obtained in 172 patients. Serial echocardiographic assessment showed complete closure in all but 2 patients, in whom an additional small non-significant posterior defect was purposely left untouched. There have been no episodes of late arrhythmias, device embolization, cardiac erosion, endocarditis, thromboembolism, wire fracture, or death. CONCLUSIONS: Transcatheter closure of ASDs in older children, adolescents, and adults using the FOD was highly successful in a wide range of anatomical scenarios with high closure rates and no complications in mid-term follow-up.


Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal/efeitos adversos , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
2.
Arq. bras. cardiol ; 113(1 supl.2): 1-1, jul., 2019.
Artigo em Português | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1015662

RESUMO

INTRODUÇÃO: O Implante transcateter da valva pulmonar (ITVP) é terapia consagrada para o reestabelecimento da via de saída do ventrículo direito (VD) em pacientes com disfunção pulmonar grave. Apesar de promover melhora do VD, pouco se sabe sobre o seu impacto na qualidade de vida (QV). MÉTODOS: Estudo prospectivo e multicêntrico com pacientes submetidos ao ITVP, com enfoque no impacto clínico e na qualidade de vida. Pacientes com disfunção pulmonar grave e submetidos ao ITVP foram incluídos. Dados clínicos, ecocardiográficos (ECO), de teste cardiopulmonar (TCP) e ressonância magnética (RNM) previamente e 1 ano após o ITVP foram comparados (média e desvio-padrão). Da mesma forma, foi avaliada a qualidade de vida através do questionário SF-36 para os maiores de 18 anos e SF-10 para os menores. RESULTADOS: De 17/12/2013 a 31/12/2017 foram incluídos 19 pacientes (11 masculinos). No procedimento tinham média de 21,0±7,1 anos e 56,2±15,7 Kg. O número de cirurgias prévias foi de 2 (1-4) e o tempo desde a última foi 10,6±5,6 anos. Dez pacientes apresentavam estenose pulmonar (53%), 4 insuficiências (21%) e 5 lesões mista (26%). Foi observado sucesso imediato, com queda do gradiente sistólico ao cate de 38,8±22,0 para 9,9±6,8 mmHg e relação das pressões do VD/Aorta de 0,70±0,21 para 0,37±0,07 mmHg (ambos p 0,001). Após 1 ano de seguimento, houve melhora dos índices: Classe funcional de 2 (1-3) para 1 (1-2) (p < 0,001), frequência cardíaca máxima ao TCP de 81,0±7,9 para 85,9±11,4 bpm (p 0,006), volumes diastólico e sistólico finais de VD (VDFVD e VSFVD) à RNM de 109,1±33,3 e 60,8±29,0 ml/m2 para 92,5±29,2 e 47,9±19,9 ml/m2 (p <0,0001 e p 0,004), respectivamente. Além disto, aumento dos VDFVE e VSFVE de 80,0±19,6 e 32,1±10,6 ml/m2 para 87,9±16,2 e 37,7±10,8 ml/m2 (p 0,049 e p 0,035). A análise da QV mostrou melhora somente nos pacientes maiores de 18 anos, com aumento da percepção de saúde física (PCS) de 45,7±8,0 para 52,1±6,3 (p 0,006) e saúde mental (MCS) de 46,1±11,2 para 55,1±8,4 (p 0,008). Neste período, não houve óbitos. Um dos pacientes apresentou endocardite bacteriana 9 meses após o implante e necessitou cirurgia cardíaca para troca valvar, com sucesso, sem complicações. CONCLUSÃO: O ITVP mostrou-se factível, seguro eficaz na primeira experiência brasileira. Após 1 ano de seguimento, houve inquestionável melhora clínica e na qualidade de vida - esta última, somente nos pacientes maiores de idade, provavelmente em virtude do baixo número de incluídos. (AU)


Assuntos
Humanos , Pacientes , Qualidade de Vida , Substituição da Valva Aórtica Transcateter
3.
Sci Rep ; 3: 3054, 2013 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-24165828

RESUMO

We present an approach to control the magnetic structure of adatoms adsorbed on a substrate having a high magnetic susceptibility. Using finite Ni-Pt and Fe-Pt nanowires and nanostructures on Pt(111) surfaces, our ab initio results show that it is possible to tune the exchange interaction and magnetic configuration of magnetic adatoms (Fe or Ni) by introducing different numbers of Pt atoms to link them, or by including edge effects. The exchange interaction between Ni (or Fe) adatoms on Pt(111) can be considerably increased by introducing Pt chains to link them. The magnetic ordering can be regulated allowing for ferromagnetic or antiferromagnetic configurations. Noncollinear magnetic alignments can also be stabilized by changing the number of Pt-mediated atoms. An Fe-Pt triangularly-shaped nanostructure adsorbed on Pt(111) shows the most complex magnetic structure of the systems considered here: a spin-spiral type of magnetic order that changes its propagation direction at the triangle vertices.

4.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 27(1): 39-48, jan.-mar. 2017. ilus
Artigo em Português | LILACS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-836944

RESUMO

A comunicação interatrial tipo ostium secundum (CIA OS) é uma cardiopatia congênita relativamente frequente, que causa repercussão hemodinâmica para o ventrículo direito, com sobrecarga volumétrica e dilatação da câmara. A maioria dos pacientes é assintomática, porém sintomas podem aparecer depois da segunda década de vida. O tratamento eletivo é usualmente realizado próximo ao quinto ano de vida, podendo ser indicado mais precocemente quando houver sintomatologia exuberante. O fechamento transcateter usando uma prótese de duplo disco é bem estabelecido como a primeira escolha de tratamento para a maioria dos pacientes de anatomia favorável. Foi comprovado que o forame oval patente (FOP) está associado à acidente vascular cerebral isquêmico (AVCI) em pacientes com poucos ou nenhum fator de risco de doença cardiovascular. Recentemente, foi demonstrado que a oclusão transcateter do FOP é superior ao tratamento clínico para prevenir recorrências de AVCI nessa população, em um estudo randomizado com acompanhamento clínico de longo prazo. Este manuscrito revisa as atuais indicações, critérios de seleção do paciente e o seguimento clínico dos pacientes com CIA OS e FOP submetidos ao tratamento transcateter


Ostium secundum atrial septal defect (OS-ASD) is a relatively frequent congenital heart defect that causes hemodynamic burden on the right ventricle with volume overload and chamber dilatation. Most patients are asymptomatic, however symptoms can appear after the second decade of life. Elective treatment is usually performed around the fifth year of life, and may be occasionally indicated earlier if there are exuberant symptoms. Transcatheter closure using a double disc device is well established as the first choice of treatment for most patients with suitable anatomy. Patent foramen ovale (PFO) has been shown to be associated with ischemic stroke in patients with no or limited risk factors for cardiovascular disease. It was recently demonstrated in a randomized trial with long-term follow-up that transcatheter closure of PFO is superior to medical treatment for preventing recurrences of stroke in this patient population. This manuscript reviews the current indications, patient selection criteria, and long-term follow-up in patients with OS-ASD and PFO submitted to transcatheter closure


Assuntos
Humanos , Masculino , Feminino , Criança , Forame Oval Patente/terapia , Átrios do Coração/cirurgia , Cardiopatias Congênitas/fisiopatologia , Comunicação Interatrial/terapia , Ventrículos do Coração , Cirurgia Torácica , Ecocardiografia/métodos , Cateterismo Cardíaco/métodos , Heparina/administração & dosagem , Aspirina/administração & dosagem , Fatores de Risco , Resultado do Tratamento , Artéria Femoral , Cateteres Cardíacos , Coração/fisiopatologia
5.
Rev. bras. cardiol. invasiva ; 19(4): 430-441, dez. 2011. ilus
Artigo em Português | LILACS, SES-SP | ID: lil-618804

RESUMO

INTRODUÇÃO: Uma nova geração de próteses Amplatzer com menor perfil e maior flexibilidade foi desenvolvida recentemente para o tratamento percutâneo da persistência do canal arterial (PCA). Neste artigo é relatado o uso desse novo dispositivo, Amplatzer Duct Occludder IITM (ADO II), para o tratamento tanto de PCA como de outros defeitos congênitos e estruturais, avaliando sua eficácia e segurança. Métodos: Estudo longitudinal observacional de um coorte de pacientes portadores de cardiopatias congênitas e estruturais tratados com ADO II entre outubro de 2009 e agosto de 2011. Pacientes com menos de 5 kg e canais > 5,5 mm e/ou do tipo B foram excluídos do estudo. A prótese foi implantada por vias anterógrada ou retrógrada. A cintura foi cerca de 2 mm maior que o defeito e o comprimento da prótese foi de 4 mm para lesões mais curtas ( até 6-8 mm). Resultados: Foram incluídos no estudo 28 pacientes, com mediana de idade e de peso de 2 anos e 11,7 kg, respectivamente, dos quais 23 eram portadores de PCA com diâmetro mínimo de 2,3 +- 0,8 mm. Os demais apresentavam...


BACKGROUND: A new generation of Amplatzer devices with lower profile and greater flexibility has been recently developed for percutaneous occlusion of the patent ductus arteriosus (PDA). In this paper, the use of this new device, the Amplatzer Duct Occludder II TM (ADO II) for percutaneous closure of the PDA as well as for the treatment of other congenital and structural heart defects is reported, assessing its safety and efficacy. METHODS: Longitudinal and observational study of a cohort of patients with congenital and structural heart defects treated with ADO II between October 2009 and August 2011. Patients weighing less than 5 kg and PDAs > 5.5 mm and/or type B were excluded. The device was implanted using the antegrade or retrograde approach. The waist was 2 mm larger than the defect and the length of the prosthesis was 4 mm for shorter lesions (less than 6-8 mm). RESULTS: Twenty-eight patients with a median age and weight of 2 years and 11.7 kg, respectively, were included. Twenty-three had a PDA with a mean minimal diameter of 2.3 + 0.8 mm. The remainder had muscular ventricular septal defect (1), pulmonary arteriovenous fistula (1), ruptured aneurysm of the sinus of Valsalva (1), and univentricular heart in the early postoperative period of bidirectional cavopulmonary anastomosis with residual antegrade pulmonary flow (2). The device was successfully implanted in all patients, except for an infant weighing 8 kg with a long, tortuous and oblique PDA with a diameter of 2.8 mm and a shallow ampulla. There was total occlusion of the defects in all patients. One patient with univentricular heart and right isomerism died due to complications not related to the procedure. CONCLUSIONS: ADO II proved to be a flexible, safe and effective device for the percutaneous treatment of infants, children and selected adults with PDA and other congenital and structural heart defects. Its use may have limitations for some anatomical PDA configurations in smaller infants.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Próteses e Implantes , Canal Arterial/anormalidades , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Angiografia/métodos , Angiografia , Ecocardiografia/métodos , Ecocardiografia
6.
J Interv Cardiol ; 29(2): 208-215, 2016. ilus, tab
Artigo em Inglês | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1063679

RESUMO

The secundum atrial septal defect (ASD) is acommon congenital heart defect (CHD), especially inadults. 1 Most of these defects are amenable for transcatheter closure, which became the method of choice to treat most patients due to its safety and efficacy with excellent mid-to-long term outcomes. 2–5 Although cardiac erosions may occur after the use of the Amplatzer Septal Occluder (ASO),6 this complication is very rare. The Figulla-Occlutech device (FOD;Occlutech, Jena, Germany) is relatively new, being anitinol double-disk occluder with a self-centering mechanism provided by a central connecting waist...


Assuntos
Implantação de Lâmina , Substituição da Valva Aórtica Transcateter
7.
São Paulo; s.n; 20221208.
Não convencional em Português | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1442736

RESUMO

INTRODUÇÃO E/OU FUNDAMENTOS: Algumas cardiopatias congênitas cursam com anormalidades na valva tricúspide que requerem plastia ou troca valvar. A durabilidade das biopróteses na posição tricúspide é baixa com necessidade de reintervenção de cerca 50% em 5 anos. O implante percutâneo valvar dentro destas próteses ("valve-in-valve") tem sido descrito com resultados animadores. O objetivo é relatar a experiência inicial com este procedimento. MÉTODOS: Estudo prospectivo observacional de pacientes previamente operados de cardiopatias congênitas com bipróteses com disfunção (estenose e/ou insuficiência) em posição tricúspide submetidos a revalvularização percutânea. Foram utilizadas as próteses Melody, Sapien XT e S3 e MyVal por via femoral ou jugular. A escolha do diâmetro foi 1-3 mm maior que o anel interno protético. O seguimento foi clínico e ecocardiográfico. RESULTADOS E CONCLUSÕES: Sete pacientes (11 a 35 anos; 32-80 kgs) previamente operados (4 Ebstein, 2 Fallot e 1 EPV crítica) com bioprótese tricúspide foram submetidos ao procedimento com sucesso e implante na posição desejada. A valva Melody implantada a 24 mm apresentou insuficiência moderada. Nas 3 biopróteses S3 e MyVal implantadas a 26-30 mm o funcionamento valvar foi adequado com abolição do gradiente e da insuficiência. Uma paciente apresentou bloqueio AV total revertido com corticóide 2 semanas após. Um paciente (da Melody) com anemia falciforme faleceu de sepsis 1 ano depois. Em um seguimento variando de 1 mês a 3 anos a função valvar permaneceu preservada na ecocadiografia nos 6 pacientes com melhora significativa da classe funcional. Conclusões: Nesta experiência inicial, a revalvularização percutânea da bioprótese tricúspide foi factível, segura e eficaz no curto prazo. Próteses disponíveis em diâmetros maiores (S3 e MyVal) parecem ser mais adequadas.

8.
São Paulo; s.n; 20221208.
Não convencional em Português | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1442510

RESUMO

INTRODUÇÃO E/OU FUNDAMENTOS: A valva Melody, indicada para revalvularização percutânea pulmonar, tem sido usada no Brasil desde 2013. Nos EUA a probabilidade de endocardite (EI) tardia é de 9,5% em 5 anos e 16,9% em 8 anos (mortalidade de 6,7%). Gradientes residuais (GR), faixa etária no implante e história prévia de EI têm sido implicados como fatores de risco. No Brasil, onde encontramos uma população heterogenea, não temos esta informação. Objetivo é determinar a incidência e os desfechos da EI tardia após implante de Melody no Brasil. MÉTODOS: Estudo de coorte observacional, retrospectivo, de pacientes submetidos a implante da Melody. Todos os centros implantadores foram contatados para reportar o número total de implantes e dos casos de EI, incluindo o momento do diagnóstico, manejo e o desfecho final. O diagnóstico de EI foi baseado em critérios clínicos, culturas, ecocardiograma e, por vezes, tomografia. RESULTADOS E CONCLUSÕES: 87 pacientes foram submetidos ao implante em 10 centros no Brasil. Em 9 anos de seguimento, 7 pacientes tiveram EI tardia (8,0%), com 2 óbitos (2,2% do total e 28% dos casos de EI). Em 3 pacientes o quadro foi agudo e em 4 sub-agudo. Um caso acometeu uma criança, sendo o restante em adultos, todos após 1 ano ou mais do implante. Um paciente possuía GR elevado previamente por "mismatch". A EI foi associada a piora importante do gradiente em 3 pacientes: um submetido a dilatação com balão e os outros 2 a troca valvar, com 1 óbito após cirurgia tardia. Os germes identificados foram S. aureus (1), S. viridans (1), Pseudomonas (1) e S. Cristatus (1). Em 3 pacientes as hemoculturas foram negativas. O manejo incluiu, além da antibioticoterapia, explante valvar em 3 (um óbito em paciente crítico, estenose grave e falência do VD), valvoplastia com balão em 1 e tratamento conservador em 3 (com 1 óbito devido a embolia pulmonar). Dos 7 casos de EI, em 4 identificamos fatores de risco que poderiam ter sido evitados: injeção intramuscular de anabolizantes, tratamento dentário sem profilaxia adequada, presença de piercing e tatuagem e história prévia de EI. Nos 4 casos curados nos quais a Melody foi mantida, observou-se estenose e/ou insuficiência discreta a moderada da valva. CONCLUSOES: A incidência de EI tardia na valva Melody no Brasil é significativa, mas não difere significativamente dos dados de literatura. Encontramos fatores de risco diferentes dos relatados previamente, muitos deles evitáveis. Além da incidência significativa, a EI pode se apresentar de forma aguda e ser letal.


Assuntos
Valvas Cardíacas
9.
São Paulo; s.n; 20221208.
Não convencional em Português | CONASS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1442613

RESUMO

INTRODUÇÃO E/OU FUNDAMENTOS: O implante percutâneo da valva pulmonar tem sido realizado há mais de 20 anos, principalmente nos condutos e biopróteses na via de saída do ventrículo direito (VSVD). Algumas limitações são observadas com os sistemas disponíveis atuais incluindo diâmetros finais limitados a 22 mm (Melody) e/ou necessidade de bainhas de alto perfil (22-24 F) e rigidez do sistema (Sapien S3). O objetivo é avaliar a factibilidade, segurança e eficácia do implante da prótese MyVal (Meril) na posição pulmonar. MÉTODOS: Estudo piloto prospectivo observacional de pacientes com disfunção da VSVD (estenose e/ou insuficiência) necessitando de revalvularização segundo critérios clínicos. O procedimento foi realizado sob anestesia geral e a prótese MyVal colocada através de sistema 14-16 Fr após teste de complacência da VSVD e de compressão coronária. O seguimento foi clínico e ecocardiográfico. RESULTADOS E CONCLUSÕES: Oito pacientes (5 a 67 anos; 15-80 kgs) com VSVD disfuncional (2 condutos; 3 biopróteses; 2 com retalho transanular e uma nativa) foram submetidos ao procedimento com sucesso. Foram usadas próteses de 20 a 32 mm (estas nas VSVD mais dilatadas). Com exceção da criança de 15 kgs, não houve dificuldades para avanço do sistema. O implante no local desejado foi obtido em todos os casos com redução significativa do gradiente e/ou abolição da insuficiência. A criança de 15 kgs apresentou trombose femoral após. Em um seguimento variando de 1 mês a 1 ano e meio a função valvar permanece preservada na ecocadiografia. Houve melhora significativa da classe funcional. CONCLUSÕES: O implante da prótese MyVal na posição pulmonar foi factível, seguro e eficaz no curto prazo nesta experiência inicial. O sistema de menor perfil e mais flexível se mostrou versátil permitindo também abordar crianças pequenas. As VSVD dilatadas com ou sem retalhos puderam ser revalvularizadas com próteses 32 mm. Estudos com mais pacientes e com maior seguimento são necessários.

10.
In. Abizaid, Alexandre; Costa Júnior, J. Ribamar. Manual de cardiologia intervencionista do Instituto Dante Pazzanese. Rio de Janeiro, Elsevier, 2013. p.419-440, ilus.
Monografia em Português | SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-1081676
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa