Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 94(2): 695-703, 2022 01 18.
Artigo em Inglês | MEDLINE | ID: mdl-34923818

RESUMO

We present the derivation of a new kind of loss function from the symmetry rules of synchronous and asynchronous two-dimensional correlation maps. This loss function, which takes into account correlations that are based on causal relations among the members of a series of spectra, can be employed to solve non-linear inverse problems that are plagued by systematic multiplicative errors. This possibility results from the correlation-based loss function being practically insensitive to such systematic errors, which often arise in spectroscopy because sample spectra are usually ratioed against reference spectra. Using dispersion analysis, a sophisticated method of band fitting, of the spectra of poly(methyl methacrylate) films deposited on gold, we demonstrate the applicability and validity of the new loss function. If gold is used as a substrate, experimental spectra are often unphysical, that is, they display reflectance values larger than unity. In such cases, our correlation-based loss function not only helps to achieve accurate fits but also provides corrections to obtain physically meaningful spectra, which leads to results that are superior to conventional correction methods. The validity of the results is checked and proved with help of the results of dispersion analysis of spectra of films of poly(methyl methacrylate) on calcium fluoride (CaF2) and silicon (Si), which do not suffer from the systematic errors.


Assuntos
Análise Espectral
2.
Langmuir ; 35(30): 9912-9922, 2019 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-31277548

RESUMO

Knowledge of the thermotropic phase behavior of solid-supported bilayer lipid assemblies is essential to mimick the molecular organization and lateral fluidity of cell membranes. The gel-to-fluid phase transitions in a homologous series of single phospholipid bilayers supported on planar silicon substrates were investigated by temperature-controlled atomic force microscopy and attenuated total reflection infrared spectroscopy to obtain complementary information at the mesoscopic and molecular scales. Symmetric bilayers of dipalmitoylphosphatidylcholine (DPPC) and vertically asymmetric bilayers composed of a leaflet of DPPC and another of acyl-chain-deuterated DPPC (DPPC-d62) were prepared by the Langmuir-Blodgett technique. The selective deuteration of one of the bilayer leaflets enabled the simultaneous monitoring by IR spectroscopy of the acyl chain melting in each leaflet via the spectrally isolated CH2 and CD2 stretching vibrations. Two gel-to-fluid transitions were discerned for both the symmetric and asymmetric bilayers in ultrapure water. The deuterium isotope effect observed in free-standing membranes was maintained for the supported bilayers. IR spectroscopy revealed that the melting of one leaflet promotes the disordering of the acyl chains in the adjacent one. The findings suggest that the two leaflet phase transitions do not evolve in isolation. This work sheds insight into the nature of leaflet-leaflet interactions and the thermodynamic properties of surface-confined phospholipid bilayers.

3.
Chem Soc Rev ; 46(13): 3922-3944, 2017 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-28644491

RESUMO

Recent years have seen tremendous improvement of our understanding of high resolution reachable in TERS experiments, forcing us to re-evaluate our understanding of the intrinsic limits of this field, but also exposing several inconsistencies. On the one hand, more and more recent experimental results have provided us with clear indications of spatial resolutions down to a few nanometres or even on the subnanometre scale. Moreover, lessons learned from recent theoretical investigations clearly support such high resolutions, and vice versa the obvious theoretical impossibility to evade high resolution from a purely plasmonic point of view. On the other hand, most of the published TERS results still, to date, claim a resolution on the order of tens of nanometres that would be somehow limited by the tip apex, a statement well accepted for the past 2 decades. Overall, this now leads the field to a fundamental question: how can this divergence be justified? The answer to this question brings up an equally critical one: how can this gap be bridged? This review aims at raising a fundamental discussion related to the resolution limits of tip-enhanced Raman spectroscopy, at revisiting our comprehension of the factors limiting it both from a theoretical and an experimental point of view and at providing indications on how to move the field ahead. It is our belief that a much deeper understanding of the real accessible lateral resolution in TERS and the practical factors that limit them will simultaneously help us to fully explore the potential of this technique for studying nanoscale features in organic, inorganic and biological systems, and also to improve both the reproducibility and the accuracy of routine TERS studies. A significant improvement of our comprehension of the accessible resolution in TERS is thus critical for a broad audience, even in certain contexts where high resolution TERS is not the desired outcome.

4.
Faraday Discuss ; 205: 213-226, 2017 12 04.
Artigo em Inglês | MEDLINE | ID: mdl-28914312

RESUMO

Plasmon-induced chemical reactions have recently attracted great attention as a promising method for high efficiency light-energy conversion and proved to be useful in a wealth of different domains of chemistry and physics. One of the interesting and, so far, less explored avenues of such reactions is their potential for efficient, highly localized and controlled polymer production. Here, we present the first example of a localized, directed plasmon catalyzed polymerization process of a self-assembled monolayer on both silver and gold surfaces monitored by surface- and tip-enhanced Raman spectroscopy (SERS and TERS). As a proof-of-concept, a bi-functionalized dibenzo(1,2)dithiine-3,8-diamine (D3ATP) molecule that undergoes a well-known plasmon-induced coupling via the amino group into an azo group has been used. Initial dimerization is demonstrated using established marker bands associated with the formation of the azo group. A subsequent indicator for a polymerization reaction, the appearance of a new characteristic band, is monitored by time-dependent SERS and TERS experiments. We demonstrate that the dimerization reaction and hence, the subsequent polymerization, can be induced by a plasmonic feature, e.g. a TERS tip, at specific nanoscale locations and, at a much larger micron scale, by continuously scanning the plasmonic probe. The presented results provide the basis for designing further plasmonic catalysis experiments in general, and offer a new platform for producing ultra-thin polymer films with a defined structural dimension.

5.
Appl Spectrosc ; 77(6): 583-592, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35081774

RESUMO

Based on hybrid 2D correlation analysis, we recently derived and introduced a "smart error sum," a sophisticated loss function that can be used for solving nonlinear inverse problems like the determination of optical constants and oscillator parameters from a series of optical spectra in the infrared spectral region. The advantage of the smart error sum compared to the conventional sum of squared errors lies in its ability to marginalize multiplicative systematic errors such as, for example, reflectance values above unity in transflection spectra. This is enabled by a transformation, which allows fits to not exclusively focus on forcing fit spectra to agree with experimental spectra at every wavenumber point by all means, but also to take correlations such as spectral similarities and their changes with certain perturbations into account. In this work, we extend our approach to accommodate the treatment of individual spectra, instead of only series, based on hybrid two-trace two-dimensional (2T2D) correlation analysis. We evaluate and prove the value of our approach by individually analyzing experimental transflection spectra of polymethyl methacrylate (PMMA) layers on gold substrates. The comparison of the results with those obtained by the original smart error sum based on the whole set of spectra as well as those resulting from conventional fitting of series and individual spectra (using the conventional sum of squared errors) confirms the validity and soundness of the 2T2D smart error sum.

6.
Biosensors (Basel) ; 13(6)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37366959

RESUMO

We introduce a magnetic bead-based sample preparation scheme for enabling the Raman spectroscopic differentiation of severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2)-positive and -negative samples. The beads were functionalized with the angiotensin-converting enzyme 2 (ACE2) receptor protein, which is used as a recognition element to selectively enrich SARS-CoV-2 on the surface of the magnetic beads. The subsequent Raman measurements directly enable discriminating SARS-CoV-2-positive and -negative samples. The proposed approach is also applicable for other virus species when the specific recognition element is exchanged. A series of Raman spectra were measured on three types of samples, namely SARS-CoV-2, Influenza A H1N1 virus and a negative control. For each sample type, eight independent replicates were considered. All of the spectra are dominated by the magnetic bead substrate and no obvious differences between the sample types are apparent. In order to address the subtle differences in the spectra, we calculated different correlation coefficients, namely the Pearson coefficient and the Normalized cross correlation coefficient. By comparing the correlation with the negative control, differentiating between SARS-CoV-2 and Influenza A virus is possible. This study provides a first step towards the detection and potential classification of different viruses with the use of conventional Raman spectroscopy.


Assuntos
COVID-19 , Vírus da Influenza A Subtipo H1N1 , Humanos , SARS-CoV-2/metabolismo , COVID-19/diagnóstico , Peptidil Dipeptidase A/química , Peptidil Dipeptidase A/metabolismo , Análise Espectral Raman , Fenômenos Magnéticos
7.
Light Sci Appl ; 9: 35, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32194949

RESUMO

Tip-enhanced Raman spectroscopy (TERS) is currently widely recognized as an essential but still emergent technique for exploring the nanoscale. However, our lack of comprehension of crucial parameters still limits its potential as a user-friendly analytical tool. The tip's surface plasmon resonance, heating due to near-field temperature rise, and spatial resolution are undoubtedly three challenging experimental parameters to unravel. However, they are also the most fundamentally relevant parameters to explore, because they ultimately influence the state of the investigated molecule and consequently the probed signal. Here we propose a straightforward and purely experimental method to access quantitative information of the plasmon resonance and near-field temperature experienced exclusively by the molecules directly contributing to the TERS signal. The detailed near-field optical response, both at the molecular level and as a function of time, is evaluated using standard TERS experimental equipment by simultaneously probing the Stokes and anti-Stokes spectral intensities. Self-assembled 16-mercaptohexadodecanoic acid monolayers covalently bond to an ultra-flat gold surface were used as a demonstrator. Observation of blinking lines in the spectra also provides crucial information on the lateral resolution and indication of atomic-scale thermally induced morphological changes of the tip during the experiment. This study provides access to unprecedented molecular-level information on physical parameters that crucially affect experiments under TERS conditions. The study thereby improves the usability of TERS in day-to-day operation. The obtained information is of central importance for any experimental plasmonic investigation and for the application of TERS in the field of nanoscale thermometry.

8.
Appl Spectrosc ; 67(4): 409-19, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23601541

RESUMO

Polarized Raman spectroscopy is widely used to quantify the level of molecular orientation of various types of materials. By using a simplified procedure we call the depol (depolarization) constant (DC) method, since it assumes that the depolarization ratio is a constant. However, our ability to quantify orientation by using the DC method is often limited by the need for a completely isotropic sample showing the same chemical and phase composition as the oriented sample of interest to obtain information on the depolarization ratio. In this paper, we propose a new method for orientation quantification, the most probable distribution (MPD) method, based on the hypothesis that the population distribution is the most probable one. In contrast to the conventional DC procedure, this new method does not require knowledge of the depolarization ratio and eliminates the assumption that it does not evolve on orientation. Simulations show the wide applicability of the MPD method for large sections of the 〈P2〉 〈P4〉 diagram, especially for coordinates that are most likely to be observed in experimental conditions. They also highlight the significant inaccuracies produced by the conventional DC method due to depolarization ratio errors.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa