1.
J Hand Surg Am ; 26(6): 1053-7, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11721250

RESUMO

Recognition of interosseous membrane disruption associated with radial head injury and Essex-Lopresti injury is important, especially if radial head excision is contemplated. Because a widely accepted method to diagnose interosseous membrane disruption does not exist, we evaluated the accuracy of ultrasonography to diagnose this injury in a cadaver model. Nine pairs of cadaver forearms were randomized into 2 groups. The central third of the interosseous membrane of forearms of group 1 was cut, whereas it was visualized but not cut in group 2. A dynamic ultrasound examination was performed to determine interosseous membrane integrity, and static images were made. The static images were evaluated by 2 other radiologists and interpretations were recorded. One radiologist incorrectly interpreted 1 pair of forearms; the other 2 radiologists were 100% accurate. The accuracy of ultrasonography in detecting interosseous injuries was 96% with our methods.


Assuntos
Traumatismos do Antebraço/diagnóstico por imagem , Periósteo/diagnóstico por imagem , Periósteo/lesões , Fenômenos Biomecânicos , Cadáver , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Supinação , Ultrassonografia