RESUMO
BACKGROUND: Most patients with metastatic cancer eventually develop resistance to systemic therapy, with some having limited disease progression (ie, oligoprogression). We aimed to assess whether stereotactic body radiotherapy (SBRT) targeting oligoprogressive sites could improve patient outcomes. METHODS: We did a phase 2, open-label, randomised controlled trial of SBRT in patients with oligoprogressive metastatic breast cancer or non-small-cell lung cancer (NSCLC) after having received at least first-line systemic therapy, with oligoprogression defined as five or less progressive lesions on PET-CT or CT. Patients aged 18 years or older were enrolled from a tertiary cancer centre in New York, NY, USA, and six affiliated regional centres in the states of New York and New Jersey, with a 1:1 randomisation between standard of care (standard-of-care group) and SBRT plus standard of care (SBRT group). Randomisation was done with a computer-based algorithm with stratification by number of progressive sites of metastasis, receptor or driver genetic alteration status, primary site, and type of systemic therapy previously received. Patients and investigators were not masked to treatment allocation. The primary endpoint was progression-free survival, measured up to 12 months. We did a prespecified subgroup analysis of the primary endpoint by disease site. All analyses were done in the intention-to-treat population. The study is registered with ClinicalTrials.gov, NCT03808662, and is complete. FINDINGS: From Jan 1, 2019, to July 31, 2021, 106 patients were randomly assigned to standard of care (n=51; 23 patients with breast cancer and 28 patients with NSCLC) or SBRT plus standard of care (n=55; 24 patients with breast cancer and 31 patients with NSCLC). 16 (34%) of 47 patients with breast cancer had triple-negative disease, and 51 (86%) of 59 patients with NSCLC had no actionable driver mutation. The study was closed to accrual before reaching the targeted sample size, after the primary efficacy endpoint was met during a preplanned interim analysis. The median follow-up was 11·6 months for patients in the standard-of-care group and 12·1 months for patients in the SBRT group. The median progression-free survival was 3·2 months (95% CI 2·0-4·5) for patients in the standard-of-care group versus 7·2 months (4·5-10·0) for patients in the SBRT group (hazard ratio [HR] 0·53, 95% CI 0·35-0·81; p=0·0035). The median progression-free survival was higher for patients with NSCLC in the SBRT group than for those with NSCLC in the standard-of-care group (10·0 months [7·2-not reached] vs 2·2 months [95% CI 2·0-4·5]; HR 0·41, 95% CI 0·22-0·75; p=0·0039), but no difference was found for patients with breast cancer (4·4 months [2·5-8·7] vs 4·2 months [1·8-5·5]; 0·78, 0·43-1·43; p=0·43). Grade 2 or worse adverse events occurred in 21 (41%) patients in the standard-of-care group and 34 (62%) patients in the SBRT group. Nine (16%) patients in the SBRT group had grade 2 or worse toxicities related to SBRT, including gastrointestinal reflux disease, pain exacerbation, radiation pneumonitis, brachial plexopathy, and low blood counts. INTERPRETATION: The trial showed that progression-free survival was increased in the SBRT plus standard-of-care group compared with standard of care only. Oligoprogression in patients with metastatic NSCLC could be effectively treated with SBRT plus standard of care, leading to more than a four-times increase in progression-free survival compared with standard of care only. By contrast, no benefit was observed in patients with oligoprogressive breast cancer. Further studies to validate these findings and understand the differential benefits are warranted. FUNDING: National Cancer Institute.
Assuntos
Neoplasias da Mama , Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Humanos , Feminino , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Neoplasias da Mama/radioterapia , Neoplasias da Mama/etiologia , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/tratamento farmacológico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversosRESUMO
OBJECTIVE: To generate a prediction model for selection of treatment modality for early-stage non-small cell lung cancer (NSCLC). SUMMARY BACKGROUND DATA: Stereotactic body radiotherapy (SBRT) and minimally invasive surgery (MIS) are used in the local treatment of early-stage NSCLC. However, selection of patients for either SBRT or MIS remains challenging, due to the multitude of factors influencing the decision-making process. METHODS: We analyzed 1291 patients with clinical stage I NSCLC treated with intended MIS or SBRT from January 2020 to July 2023. A prediction model for selection for SBRT was created based on multivariable logistic regression analysis. The receiver operating characteristic curve analysis stratified the cohort into 3 treatment-related risk categories. Post-procedural outcomes, recurrence and overall survival (OS) were investigated to assess the performance of the model. RESULTS: In total, 1116 patients underwent MIS and 175 SBRT. The prediction model included age, performance status, previous pulmonary resection, MSK-Frailty score, FEV1 and DLCO, and demonstrated an area-under-the-curve of 0.908 (95%CI, 0.876-0.938). Based on the probability scores (n=1197), patients were stratified into a low-risk (MIS, n=970 and SBRT, n=28), intermediate-risk (MIS, n=96 and SBRT, n=53) and high-risk category (MIS, n=10 and SBRT, n=40). Treatment modality was not associated with OS (HR of SBRT, 1.67 [95%CI: 0.80-3.48]; P=0.20). CONCLUSION: Clinical expertise can be translated into a robust predictive model, guiding the selection of stage I NSCLC patients for MIS versus SBRT and effectively categorizing them into three distinct risk groups. Patients in the intermediate category could benefit most from multidisciplinary evaluation.
RESUMO
Based on an analysis of published literature, our department recently lowered the preferred mean esophagus dose (MED) constraint for conventionally fractionated (2 Gy/fraction in approximately 30 fractions) treatment of locally advanced non-small cell lung cancer (LA-NSCLC) with the goal of reducing the incidence of symptomatic acute esophagitis (AE). The goal of the change was to encourage treatment planners to achieve a MED close to 21 Gy while still permitting MED to go up to the previous guideline of 34 Gy in difficult cases. We compared all our suitable LA-NSCLC patients treated with plans from one year before through one year after the constraint change. The primary endpoint for this study was achievability of the new constraint by the planners; the secondary endpoint was reduction in symptomatic AE. Planners were able to achieve the new constraint in statistically significantly more cases during the year following its explicit implementation than in the year before (P = 0.0025). Furthermore, 38% of patients treated after the new constraint developed symptomatic AE during their treatment as opposed to 48% of the patients treated before. This is a clinically desirable endpoint although the observed difference was not statistically significant. A subsequent power calculation suggests that this is due to the relatively small number of patients in the study.
Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia Conformacional , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Esôfago , Humanos , Neoplasias Pulmonares/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por ComputadorRESUMO
Background: Patients with unresectable locally advanced NSCLC who refuse or are not candidates for chemotherapy often receive radiation therapy (RT) alone. Hypofractionated RT (HFRT) regimens are becoming increasingly common. An analysis of the National Cancer Database (NCDB) was performed to evaluate the practice patterns and outcomes of HFRT vs. conventionally fractionated RT (CFRT) in patients with stage III NSCLC undergoing definitive RT alone.Material and methods: The NCDB was queried for all patients with stage III NSCLC diagnosed between 2004 and 2014 who received RT alone. CFRT was defined as patients treated to a total dose of 60-80 Gy in 1.8-2 Gy daily fractions. HFRT was defined as patients treated to a total dose of 50-80 Gy in 2.25-4 Gy fractions. Logistic regression, univariable and multivariable analyses (MVAs) for overall survival (OS) and propensity score matched analyses (PSMAs) were performed.Results: A total of 6490 patients were evaluated: 5378 received CFRT and 1112 received HFRT. Median CFRT dose was 66 Gy in 2 Gy fractions vs. 58.5 Gy in 2.5 Gy fractions for HFRT. HFRT was associated with older age, lower biological effective dose (BED10), academic facility type, higher T-stage and lower N-stage. On initial analysis, HFRT was associated with inferior OS (median 9.9 vs. 11.1 months, p<.001), but after adjusting for the imbalance in covariates such as age, BED10, T-stage and N-stage using PSMA, the difference in survival was no longer significant (p=.1).Conclusions: In the appropriate clinical context, HFRT can be an option for patients with locally advanced NSCLC who are not candidates for chemotherapy or surgical resection. HFRT needs to be further studied in prospective trials to evaluate toxicity and tumor control.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Bases de Dados Factuais , Fracionamento da Dose de Radiação , Feminino , Humanos , Neoplasias Pulmonares/mortalidade , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Padrões de Prática Médica/estatística & dados numéricos , Padrões de Prática Médica/tendências , Pontuação de Propensão , Hipofracionamento da Dose de Radiação , Dosagem Radioterapêutica , Taxa de Sobrevida , Estados Unidos/epidemiologiaRESUMO
PURPOSE: Deformable image registration (DIR) in low-contrast tissues is often suboptimal because of low visibility of landmarks, low driving-force to deform, and low penalty for misalignment. We aim to overcome the shortcomings for improved reconstruction of time-resolved four-dimensional magnetic resonance imaging (TR-4DMRI). METHODS AND MATERIALS: Super-resolution TR-4DMRI reconstruction utilizes DIR to combine high-resolution (highR:2x2x2mm3 ) breath-hold (BH) and low-resolution (lowR:5x5x5mm3 ) free-breathing (FB) 3D cine (2Hz) images to achieve clinically acceptable spatiotemporal resolution. A 2-step hybrid DIR approach was developed to segment low-dynamic-range (LDR) regions: low-intensity lungs and high-intensity "bodyshell" (=body-lungs) for DIR refinement after conventional DIR. The intensity in LDR regions was renormalized to the full dynamic range (FDR) to enhance local tissue contrast. A T1-mapped 4D XCAT digital phantom was created, and seven volunteers and five lung cancer patients were scanned with two BH and one 3D cine series per subject to compare the 1-step conventional and 2-step hybrid DIR using: (a) the ground truth in the phantom, (b) highR-BH references, which were used to simulate 3D cine images by down-sampling and Rayleigh-noise-adding, and (c) cross-verification between two TR-4DMRI images reconstructed from two BHs. To assess DIR improvement, 8-17 blood vessel bifurcations were used in volunteers, and lung tumor position, size, and shape were used in phantom and patients, together with the voxel intensity correlation (VIC), structural similarity (SSIM), and cross-consistency check (CCC). RESULTS: The 2-step hybrid DIR improves contrast and DIR accuracy. In volunteers, it improves low-contrast alignment from 6.5 ± 1.8 mm to 3.3 ± 1.0 mm. In phantom, it improves tumor center of mass alignment (COM = 1.3 ± 0.2 mm) and minimizes DIR directional difference. In patients, it produces almost-identical tumor COM, size, and shape (dice> 0.85) as the reference. The VIC and SSIM are significantly increased and the number of CCC outliers are reduced by half. CONCLUSION: The 2-step hybrid DIR improves low-contrast-tissue alignment and increases lung tumor fidelity. It is recommended to adopt the 2-step hybrid DIR for TR-4DMRI reconstruction.
Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Suspensão da Respiração , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , RespiraçãoRESUMO
OBJECTIVE: This study was conducted in order to describe the computed tomography (CT) features of local pleural recurrence in patients with malignant pleural mesothelioma undergoing intensity-modulated pleural radiation therapy (IMPRINT) as part of multimodality treatment. METHODS: In this observational study, 58 patients treated with IMPRINT between September 21, 2004, and December 1, 2014 were included. Baseline and follow-up CT scans were qualitatively assessed. On follow-up scans, pleural thickening was categorized as unchanged, decreased, or new/increased. New/increased pleural abnormality was subcategorized as diffuse smooth pleural thickening, diffuse nodular pleural thickening, focal pleural nodule, or multiple pleural nodules. To identify features more frequently present at the time of local recurrence, follow-up scans with local recurrence were matched to four control scans; exact conditional logistic regression was performed. RESULTS: Twenty-one (36%) patients had local pleural recurrence and 20 (34%) patients had nonpleural recurrence; 3 patients had both types of recurrence. The 1-year cumulative incidence rate of local recurrence was 27% (95% confidence interval 15, 39). On follow-up scans, three patterns of pleural abnormality were significantly associated with local recurrence: new/increased multiple pleural nodules (10 (48%) positive scans vs 0 control scans), new/increased diffuse nodular pleural thickening (7 (33%) positive scans vs 1 (1%) control scans), and new/increased focal pleural nodule (3 (14%) positive scans vs 1 (1%) control scan) (p < 0.001 for all). CONCLUSIONS: Multiple new/increased pleural nodules are the feature most commonly present at local recurrence following IMPRINT; however, any pattern of increased nodular pleural thickening is suspicious. KEY POINTS: ⢠In patients with mesothelioma receiving intensity-modulated pleural radiation as part of multimodality therapy, increasing multiple pleural nodules is the computed tomography feature most commonly present at local recurrence. ⢠In these patients, any CT pattern of increased nodular pleural thickening should be considered suspicious for local recurrence. ⢠The most common sites of nonpleural recurrence were lung parenchyma, thoracic lymph nodes, and peritoneum.
Assuntos
Neoplasias Pulmonares/diagnóstico , Mesotelioma/diagnóstico , Recidiva Local de Neoplasia/diagnóstico , Pleura/diagnóstico por imagem , Neoplasias Pleurais/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Idoso , Feminino , Humanos , Neoplasias Pulmonares/radioterapia , Masculino , Mesotelioma/radioterapia , Mesotelioma Maligno , Pessoa de Meia-Idade , Neoplasias Pleurais/radioterapia , Estudos RetrospectivosRESUMO
PURPOSE: To compare single-shot echo-planar (SS-EPI)-based and turbo spin-echo (SS-TSE)-based diffusion-weighted imaging (DWI) in Non-Small Cell Lung Cancer (NSCLC) patients and to characterize the distributions of apparent diffusion coefficient (ADC) values generated by the two techniques. METHODS: Ten NSCLC patients were enrolled in a prospective IRB-approved study to compare and optimize DWI using EPI and TSE-based techniques for radiotherapy planning. The imaging protocol included axial T2w, EPI-based DWI and TSE-based DWI on a 3 T Philips scanner. Both EPI-based and TSE-based DWI sequences used three b values (0, 400, and 800 s/mm2 ). The acquisition times for EPI-based and TSE-based DWI were 5 and 8 min, respectively. DW-MR images were manually coregistered with axial T2w images, and tumor volume contoured on T2w images were mapped onto the DWI scans. A pixel-by-pixel fit of tumor ADC was calculated based on monoexponential signal behavior. Tumor ADC mean, standard deviation, kurtosis, and skewness were calculated and compared between EPI and TSE-based DWI. Image distortion and ADC values between the two techniques were also quantified using fieldmap analysis and a NIST traceable ice-water diffusion phantom, respectively. RESULTS: The mean ADC for EPI and TSE-based DWI were 1.282 ± 0.42 × 10-3 and 1.211 ± 0.31 × 10-3 mm2 /s. The average skewness and kurtosis were 0.14 ± 0.4 and 2.43 ± 0.40 for DWI-EPI and -0.06 ± 0.69 and 2.89 ± 0.62 for DWI-TSE. Fieldmap analysis showed a mean distortion of 13.72 ± 8.12 mm for GTV for DWI-EPI and 0.61 ± 0.4 mm for DWI-TSE. ADC values obtained using the diffusion phantom for the two techniques were within 0.03 × 10-3 mm2 /s with respect to each other as well as the established values. CONCLUSIONS: Diffusion-weighted turbo spin-echo shows better geometrical accuracy compared to DWI-EPI. Mean ADC values were similar with both acquisitions but the shape of the histograms was different based on the skewness and kurtosis values. The impact of differences in respiratory technique on ADC values requires further investigation.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adenocarcinoma/radioterapia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Feminino , Humanos , Imageamento Tridimensional , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Razão Sinal-Ruído , Carga TumoralRESUMO
Pulmonary perfusion with dynamic contrast-enhanced (DCE-) MRI is typically assessed using a single-input tracer kinetic model. Preliminary studies based on perfusion CT are indicating that dual-input perfusion modeling of lung tumors may be clinically valuable as lung tumors have a dual blood supply from the pulmonary and aortic system. This study aimed to investigate the feasibility of fitting dual-input tracer kinetic models to DCE-MRI datasets of thoracic malignancies, including malignant pleural mesothelioma (MPM) and nonsmall cell lung cancer (NSCLC), by comparing them to single-input (pulmonary or systemic arterial input) tracer kinetic models for the voxel-level analysis within the tumor with respect to goodness-of-fit statistics. Fifteen patients (five MPM, ten NSCLC) underwent DCE-MRI prior to radiotherapy. DCE-MRI data were analyzed using five different single- or dual-input tracer kinetic models: Tofts-Kety (TK), extended TK (ETK), two compartment exchange (2CX), adiabatic approximation to the tissue homogeneity (AATH) and distributed parameter (DP) models. The pulmonary blood flow (BF), blood volume (BV), mean transit time (MTT), permeability-surface area product (PS), fractional interstitial volume (vI ), and volume transfer constant (KTrans ) were calculated for both single- and dual-input models. The pulmonary arterial flow fraction (γ), pulmonary arterial blood flow (BFPA ) and systemic arterial blood flow (BFA ) were additionally calculated for only dual-input models. The competing models were ranked and their Akaike weights were calculated for each voxel according to corrected Akaike information criterion (cAIC). The optimal model was chosen based on the lowest cAIC value. In both types of tumors, all five dual-input models yielded lower cAIC values than their corresponding single-input models. The 2CX model was the best-fitted model and most optimal in describing tracer kinetic behavior to assess microvascular properties in both MPM and NSCLC. The dual-input 2CX-model-derived BFA was the most significant parameter in differentiating adenocarcinoma from squamous cell carcinoma histology for NSCLC patients.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Meios de Contraste , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Mesotelioma/patologia , Modelos Estatísticos , Neoplasias Torácicas/patologia , Adenocarcinoma de Pulmão/metabolismo , Adenocarcinoma de Pulmão/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patologia , Estudos de Viabilidade , Feminino , Humanos , Cinética , Neoplasias Pulmonares/metabolismo , Masculino , Mesotelioma/metabolismo , Mesotelioma Maligno , Pessoa de Meia-Idade , Estudos Prospectivos , Neoplasias Torácicas/metabolismoRESUMO
PURPOSE: To evaluate clinical utility of respiratory-correlated (RC) four-dimensional magnetic resonance imaging (4DMRI) for lung tumor delineation and motion assessment, in comparison with the current clinical standard of 4D computed tomography (4DCT). METHODS AND MATERIALS: A prospective T2-weighted (T2w) RC-4DMRI technique was applied to acquire coronal 4DMRI images for 14 lung cancer patients (16 lesions) during free breathing (FB) under an IRB-approved protocol, together with a breath-hold (BH) T1w 3DMRI and axial 4DMRI. Clinical simulation CT and 4DCT were acquired within 2 h. An internal navigator was applied to trigger amplitude-binned 4DMRI acquisition whereas a bellows or real-time position management (RPM) was used in the 4DCT reconstruction. Six radiation oncologists manually delineated the gross and internal tumor volumes (GTV and ITV) in 399 3D images using programmed clinical workflows under a tumor delineation guideline. The ITV was the union of GTVs within the breathing cycle without margin. Average GTV and motion range were assessed and ITV variation between 4DMRI and 4DCT was evaluated using the Dice similarity index, mean distance agreement (MDA), and volume difference. RESULTS: The mean tumor volume is similar between 4DCT (GTV4DCT = 1.0, as the reference) and T2w-4DMRI (GTVT2wMR = 0.97), but smaller in T1w MRI (GTVT1wMR = 0.76), suggesting possible peripheral edema around the tumor. Average GTV variation within the breathing cycle (22%) in 4DMRI is slightly greater than 4DCT (17%). GTV motion variation (-4 to 12 mm) and ITV variation (∆VITV =-25 to 95%) between 4DCT and 4DMRI are large, confirmed by relatively low ITV similarity (Dice = 0.72 ± 0.11) and large MDA = 2.9 ± 1.5 mm. CONCLUSION: Average GTVs are similar between T2w-4DMRI and 4DCT, but smaller by 25% in T1w BH MRI. Physician training and breathing coaching may be necessary to reduce ITV variability between 4DMRI and 4DCT. Four-dimensional magnetic resonance imaging is a promising and viable technique for clinical lung tumor delineation and motion assessment.
Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Carga Tumoral , Humanos , Neoplasias Pulmonares/radioterapia , Movimento , Órgãos em Risco/efeitos da radiação , Estudos Prospectivos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , RespiraçãoRESUMO
Post-transcriptional regulators have emerged as robust effectors of metastasis and display deregulated expression through unknown mechanisms. Here, we reveal that the human microRNA-335 locus undergoes genetic deletion and epigenetic promoter hypermethylation in every metastatic derivative obtained from independent patients' malignant cell populations. Genetic deletion of miR-335 is a common event in human breast cancer, is enriched for in breast cancer metastases, and also correlates with ovarian cancer recurrence. We furthermore identify miR-335 as a robust inhibitor of tumor reinitiation. We thus implicate the miR-335 locus on 7q32.2 as the first selective metastasis suppressor and tumor initiation suppressor locus in human breast cancer.
Assuntos
Neoplasias da Mama/fisiopatologia , Epigênese Genética , MicroRNAs/genética , MicroRNAs/metabolismo , Metástase Neoplásica/fisiopatologia , Interferência de RNA , Linhagem Celular Tumoral , Metilação de DNA , Feminino , Deleção de Genes , Humanos , Metástase Neoplásica/genética , Regiões Promotoras Genéticas/genéticaRESUMO
BACKGROUND: Stereotactic body radiotherapy (SBRT) has been adopted as the standard of care for inoperable early-stage non-small cell lung cancer (NSCLC), with local control rates consistently >90%. However, data directly comparing the outcomes of SBRT with those of conventionally fractionated radiotherapy (CONV) is lacking. MATERIAL AND METHODS: Between 1990 and 2013, 497 patients (525 lesions) with early-stage NSCLC (T1-T2N0M0) were treated with CONV (n = 127) or SBRT (n = 398). In this retrospective analysis, five endpoints were compared, with and without adjusting for clinical and dosimetric factors. Competing risks analysis was performed to estimate and compare the cumulative incidence of local failure (LF), nodal failure (NF), distant failure (DF) and disease progression. Overall survival (OS) was estimated by the Kaplan-Meier method and compared by the Cox regression model. Propensity score (PS) matched analysis was performed based on seven patient and clinical variables: age, gender, Karnofsky performance status (KPS), histology, T stage, biologically equivalent dose (BED), and history of smoking. RESULTS: The median dose delivered for CONV was 75.6 Gy in 1.8-2.0 Gy fractions (range 60-90 Gy; median BED = 89.20 Gy) and for SBRT 48 Gy in four fractions (45-60 Gy in three to five fractions; median BED = 105.60 Gy). Median follow-up was 24.4 months, and 3-year LF rates were 34.1% with CONV and 13.6% with SBRT (p < .001). Three-year OS rates were 38.9 and 53.1%, respectively (p = .018). PS matching showed a significant improvement of OS (p = .0497) for SBRT. T stage was the only variable correlating with all five endpoints. CONCLUSION: SBRT compared to CONV is associated with improved LF rates and OS. Our data supports the continued use and expansion of SBRT as the standard of care treatment for inoperable early-stage NSCLC.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Fracionamento da Dose de Radiação , Neoplasias Pulmonares/radioterapia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma Pulmonar de Células não Pequenas/patologia , Humanos , Estimativa de Kaplan-Meier , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estudos Retrospectivos , Falha de Tratamento , Resultado do TratamentoRESUMO
PURPOSE: The purpose of this study was to evaluate the quality of automatically propagated contours of organs at risk (OARs) based on respiratory-correlated navigator-triggered four-dimensional magnetic resonance imaging (RC-4DMRI) for calculation of internal organ-at-risk volume (IRV) to account for intra-fractional OAR motion. METHODS AND MATERIALS: T2-weighted RC-4DMRI images were of 10 volunteers acquired and reconstructed using an internal navigator-echo surrogate and concurrent external bellows under an IRB-approved protocol. Four major OARs (lungs, heart, liver, and stomach) were delineated in the 10-phase 4DMRI. Two manual-contour sets were delineated by two clinical personnel and two automatic-contour sets were propagated using free-form deformable image registration. The OAR volume variation within the 10-phase cycle was assessed and the IRV was calculated as the union of all OAR contours. The OAR contour similarity between the navigator-triggered and bellows-rebinned 4DMRI was compared. A total of 2400 contours were compared to the most probable ground truth with a 95% confidence level (S95) in similarity, sensitivity, and specificity using the simultaneous truth and performance level estimation (STAPLE) algorithm. RESULTS: Visual inspection of automatically propagated contours finds that approximately 5-10% require manual correction. The similarity, sensitivity, and specificity between manual and automatic contours are indistinguishable (P > 0.05). The Jaccard similarity indexes are 0.92 ± 0.02 (lungs), 0.89 ± 0.03 (heart), 0.92 ± 0.02 (liver), and 0.83 ± 0.04 (stomach). Volume variations within the breathing cycle are small for the heart (2.6 ± 1.5%), liver (1.2 ± 0.6%), and stomach (2.6 ± 0.8%), whereas the IRV is much larger than the OAR volume by: 20.3 ± 8.6% (heart), 24.0 ± 8.6% (liver), and 47.6 ± 20.2% (stomach). The Jaccard index is higher in navigator-triggered than bellows-rebinned 4DMRI by 4% (P < 0.05), due to the higher image quality of navigator-based 4DMRI. CONCLUSION: Automatic and manual OAR contours from Navigator-triggered 4DMRI are not statistically distinguishable. The navigator-triggered 4DMRI image provides higher contour quality than bellows-rebinned 4DMRI. The IRVs are 20-50% larger than OAR volumes and should be considered in dose estimation.
Assuntos
Imageamento por Ressonância Magnética , Algoritmos , Humanos , Movimento (Física) , Planejamento da Radioterapia Assistida por Computador , Respiração , Estudos RetrospectivosRESUMO
The presence of two intact lungs makes it challenging to reach a tumoricidal dose with hemithoracic pleural intensity-modulated radiation therapy (IMRT) in patients with malignant pleural mesothelioma (MPM) who underwent pleurectomy/decortications or have unresectable disease. We developed an anatomy-based model to predict attainable prescription dose before starting optimization. Fifty-six clinically delivered IMRT plans were analyzed regarding correlation of prescription dose and individual and total lung volumes, planning target volume (PTV), ipsilateral normal lung volume and ratios: contralateral/ipsilateral lung (CIVR); contralateral lung/PTV (CPVR); ipsilateral lung /PTV (IPVR); ipsilateral normal lung /total lung (INTLVR); ipsilateral normal lung/PTV (INLPVR). Spearman's rank correlation and Fisher's exact test were used. Correlation between mean ipsilateral lung dose (MILD) and these volume ratios and between prescription dose and single lung mean doses were studied. The prediction models were validated in 23 subsequent MPM patients. CIVR showed the strongest correlation with dose (R=0.603,p<0.001) and accurately predicted prescription dose in the validation cases. INLPVR and MILD as well as MILD and prescription dose were significantly correlated (R=-0.784,p<0.001 and R=0.554,p<0.001, respectively) in the training and validation cases. Parameters obtainable directly from planning scan anatomy predict achievable prescription doses for hemithoracic IMRT treatment of MPM patients with two intact lungs. PACS number(s): 87.55.de, 87.55.dk.
Assuntos
Pulmão/efeitos da radiação , Mesotelioma/radioterapia , Neoplasias Pleurais/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Dosagem RadioterapêuticaRESUMO
Concurrent chemotherapy/radiotherapy has been considered the standard treatment for patients with a good performance status and inoperable stage III non-small-cell lung cancer (NSCLC). Three-dimensional chemoradiation therapy and intensity-modulated radiation therapy have been reported to reduce toxicity and allow a dose escalation to 70 Gy and beyond. However, the Radiation Therapy Oncology Group 0617 trial recently showed that dose escalation from 60 Gy to 74 Gy with concurrent chemotherapy in stage III NSCLC was associated with higher toxicity and worse survival. A "one size fits all" treatment approach may need to be changed and adapted to each patient's particular disease and unique biologic/anatomic features, as well as the most appropriate radiotherapy modalities for that patient. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed every 3 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application, by the panel, of a well-established consensus methodology (modified Delphi technique) to rate the appropriateness of imaging and treatment procedures. In instances in which evidence is lacking or not definitive, expert opinion may be used as the basis for recommending imaging or treatment.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/terapia , Neoplasias Pulmonares/terapia , Quimiorradioterapia , Fracionamento da Dose de Radiação , Humanos , Linfonodos/efeitos da radiação , Medicina de Precisão , Terapia com Prótons , Dosagem Radioterapêutica , Radioterapia de Intensidade ModuladaRESUMO
Superior vena cava (SVC) syndrome occurs due to obstructed blood flow through the SVC. It can present clinically on a spectrum, between asymptomatic and life-threatening emergency. Patients commonly report a feeling of fullness in the head, facial, neck and upper extremity edema, and dyspnea. On imaging, patients commonly have superior mediastinal widening and pleural effusion. The majority of cases are due to malignant causes, with non-small cell lung cancer, small cell lung cancer, and lymphoma the most commonly associated malignancies. When evaluating patients, a complete staging workup is recommended, as it will determine whether treatment should be definitive/curative or palliative in intent. If the patient requires urgent treatment of venous obstruction, such as in the cases of acute central airway obstruction, severe laryngeal edema and/or coma from cerebral edema, direct opening of the occlusion by endovascular stenting and angioplasty with thrombolysis should be considered. Such an approach can provide immediate relief of symptoms before cancer-specific therapies are initiated. The intent of treatment is to manage the underlying disease while palliating symptoms. Treatment approaches most commonly employ chemotherapy and/or radiation therapy depending on the primary histology. Mildly hypofractionated radiation regimens are most commonly employed and achieve high rates of symptomatic responses generally within 2 weeks of initiating therapy.
Assuntos
Síndrome da Veia Cava Superior , Síndrome da Veia Cava Superior/terapia , Síndrome da Veia Cava Superior/etiologia , Humanos , Cuidados Paliativos/métodos , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/terapiaRESUMO
BACKGROUND: Respiratory motion irregularities in lung cancer patients are common and can be severe during multi-fractional (â¼20 mins/fraction) radiotherapy. However, the current clinical standard of motion management is to use a single-breath respiratory-correlated four-dimension computed tomography (RC-4DCT or 4DCT) to estimate tumor motion to delineate the internal tumor volume (ITV), covering the trajectory of tumor motion, as a treatment target. PURPOSE: To develop a novel multi-breath time-resolved (TR) 4DCT using the super-resolution reconstruction framework with TR 4D magnetic resonance imaging (TR-4DMRI) as guidance for patient-specific breathing irregularity assessment, overcoming the shortcomings of RC-4DCT, including binning artifacts and single-breath limitations. METHODS: Six lung cancer patients participated in the IRB-approved protocol study to receive multiple T1w MRI scans, besides an RC-4DCT scan on the simulation day, including 80 low-resolution (lowR: 5 × 5 × 5 mm3) free-breathing (FB) 3D cine MRFB images in 40 s (2 Hz) and a high-resolution (highR: 2 × 2 × 2 mm3) 3D breath-hold (BH) MRBH image for each patient. A CT (1 × 1 × 3 mm3) image was selected from 10-bin RC-4DCT with minimal binning artifacts and a close diaphragm match (<1 cm) to the MRBH image. A mutual-information-based Freeform deformable image registration (DIR) was used to register the CT and MRBH via the opposite directions (namely F1: C T Source â MR Target BH ${\mathrm{C}}{{{\mathrm{T}}}_{{\mathrm{Source}}}} \to {\mathrm{MR}}_{{\mathrm{Target}}}^{{\mathrm{BH}}}$ and F2: C T Target â MR Source BH ${\mathrm{C}}{{{\mathrm{T}}}_{{\mathrm{Target}}}} \leftarrow {\mathrm{MR}}_{{\mathrm{Source}}}^{{\mathrm{BH}}}$ ) to establish CT-MR voxel correspondences. An intensity-based enhanced Demons DIR was then applied for MR Source BH â MR Target FB ${\mathrm{MR}}_{{\mathrm{Source}}}^{{\mathrm{BH}}} \to {\mathrm{MR}}_{{\mathrm{Target}}}^{{\mathrm{FB}}}$ , in which the original MRBH was used in D1: C T Source â ( MR Source BH â MR Target FB ) Target ${\mathrm{C}}{{{\mathrm{T}}}_{{\mathrm{Source}}}} \to {{({\mathrm{MR}}_{{\mathrm{Source}}}^{{\mathrm{BH}}} \to {\mathrm{MR}}_{{\mathrm{Target}}}^{{\mathrm{FB}}})}_{{\mathrm{Target}}}}$ , while the deformed MRBH was used in D2: ( C T Target â MR Source BH ) Source â MR Target FB ${{( \text{C}{{\text{T}}_{\text{Target}}}\leftarrow \text{MR}_{\text{Source}}^{\text{BH}} )}_{\text{Source}}}\to \text{MR}_{\text{Target}}^{\text{FB}}$ . The deformation vector fields (DVFs) obtained from each DIR were composed to apply to the deformed CT (D1) and original CT (D2) to reconstruct TR-4DCT images. A digital 4D-XCAT phantom at the end of inhalation (EOI) and end of exhalation (EOE) with 2.5 cm diaphragmatic motion and three spherical targets (Ï = 2, 3, 4 cm) were first tested to reconstruct TR-4DCT. For each of the six patients, TR-4DCT images at the EOI, middle (MID), and EOE were reconstructed with both D1 and D2 approaches. TR-4DCT image quality was evaluated with mean distance-to-agreement (MDA) at the diaphragm compared with MRFB, tumor volume ratio (TVR) referenced to MRBH, and tumor shape difference (DICE index) compared with the selected input CT. Additionally, differences in the tumor center of mass (|∆COMD1-D2|), together with TVR and DICE comparison, was assessed in the D1 and D2 reconstructed TR-4DCT images. RESULTS: In the phantom, TR-4DCT quality is assessed by MDA = 2.0 ± 0.8 mm at the diaphragm, TVR = 0.8 ± 0.0 for all tumors, and DICE = 0.83 ± 0.01, 0.85 ± 0.02, 0.88 ± 0.01 for Ï = 2, 3, 4 cm tumors, respectively. In six patients, the MDA in diaphragm match is -1.6 ± 3.1 mm (D1) and 1.0 ± 3.9 mm (D2) between the reconstructed TR-4DCT and lowR MRFB among 18 images (3 phases/patient). The tumor similarity is TVR = 1.2 ± 0.2 and DICE = 0.70 ± 0.07 for D1 and TVR = 1.4 ± 0.3 (D2) and DICE = 0.73 ± 0.07 for D2. The tumor position difference is |∆COMD1-D2| = 1.2 ± 0.8 mm between D1 and D2 reconstructions. CONCLUSION: The feasibility of super-resolution reconstruction of multi-breathing-cycle TR-4DCT is demonstrated and image quality at the diaphragm and tumor is assessed in both the 4D-XCAT phantom and six lung cancer patients. The similarity of D1 and D2 reconstruction suggests consistent and reliable DIR results. Clinically, TR-4DCT has the potential for breathing irregularity assessment and dosimetry evaluation in radiotherapy.
RESUMO
Background and purpose: Objective assessment of delivered radiotherapy (RT) to thoracic organs requires fast and accurate deformable dose mapping. The aim of this study was to implement and evaluate an artificial intelligence (AI) deformable image registration (DIR) and organ segmentation-based AI dose mapping (AIDA) applied to the esophagus and the heart. Materials and methods: AIDA metrics were calculated for 72 locally advanced non-small cell lung cancer patients treated with concurrent chemo-RT to 60 Gy in 2 Gy fractions in an automated pipeline. The pipeline steps were: (i) automated rigid alignment and cropping of planning CT to week 1 and week 2 cone-beam CT (CBCT) field-of-views, (ii) AI segmentation on CBCTs, and (iii) AI-DIR-based dose mapping to compute dose metrics. AIDA dose metrics were compared to the planned dose and manual contour dose mapping (manual DA). Results: AIDA required â¼2 min/patient. Esophagus and heart segmentations were generated with a mean Dice similarity coefficient (DSC) of 0.80±0.15 and 0.94±0.05, a Hausdorff distance at 95th percentile (HD95) of 3.9±3.4 mm and 14.1±8.3 mm, respectively. AIDA heart dose was significantly lower than the planned heart dose (p = 0.04). Larger dose deviations (>=1Gy) were more frequently observed between AIDA and the planned dose (N = 26) than with manual DA (N = 6). Conclusions: Rapid estimation of RT dose to thoracic tissues from CBCT is feasible with AIDA. AIDA-derived metrics and segmentations were similar to manual DA, thus motivating the use of AIDA for RT applications.
RESUMO
BACKGROUND: In radiotherapy, real-time tumor tracking can verify tumor position during beam delivery, guide the radiation beam to target the tumor, and reduce the chance of a geometric miss. Markerless kV x-ray image-based tumor tracking is challenging due to the low tumor visibility caused by tumor-obscuring structures. Developing a new method to enhance tumor visibility for real-time tumor tracking is essential. PURPOSE: To introduce a novel method for markerless kV image-based tracking of lung tumors via deep learning-based target decomposition. METHODS: We utilized a conditional Generative Adversarial Network (cGAN), known as Pix2Pix, to build a patient-specific model and generate the synthetic decomposed target image (sDTI) to enhance tumor visibility on the real-time kV projection images acquired by the onboard kV imager equipped on modern linear accelerators. We used 4DCT simulation images to generate the digitally reconstructed radiograph (DRR) and DTI image pairs for model training. We augmented the training dataset by randomly shifting the 4DCT in the superior-inferior, anterior-posterior, and left-right directions during the DRR and DTI generation process. We performed real-time 2D tumor tracking via template matching between the DTI generated from the CT simulation and the sDTI generated from the real-time kV projection images. We validated the proposed method using nine patients' datasets with implanted beacons near the tumor. RESULTS: The sDTI can effectively improve the image contrast around the lung tumors on the kV projection images for the nine patients. With the beacon motion as ground truth, the tracking errors were on average 0.8 ± 0.7 mm in the superior-inferior (SI) direction and 0.9 ± 0.8 mm in the in-plane left-right (IPLR) direction. The percentage of successful tracking, defined as a tracking error less than 2 mm in the SI direction, is 92.2% on the 4312 tested images. The patient-specific model took approximately 12 h to train. During testing, it took approximately 35 ms to generate one sDTI, and 13 ms to perform the tumor tracking using template matching. CONCLUSIONS: Our method offers the potential solution for nearly real-time markerless lung tumor tracking. It achieved a high level of accuracy and an impressive tracking rate. Further development of 3D lung tumor tracking is warranted.
Assuntos
Aprendizado Profundo , Tomografia Computadorizada Quadridimensional , Processamento de Imagem Assistida por Computador , Neoplasias Pulmonares , Radioterapia Guiada por Imagem , Neoplasias Pulmonares/radioterapia , Neoplasias Pulmonares/diagnóstico por imagem , Humanos , Radioterapia Guiada por Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional/métodosRESUMO
INTRODUCTION: R0 resection and radiation therapy have been associated with improved overall survival (OS) in patients with thymic carcinoma (TC). Here, we analyzed which subgroups of patients derive the greatest benefit from postoperative radiation therapy (PORT). METHODS: Clinical, pathologic, treatment, and survival information of 462 patients with TC from the International Thymic Malignancy Interest Group/European Society of Thoracic Surgeons database were analyzed. Variables included age, sex, continent of treatment, paraneoplastic syndrome, carcinoma subtype, tumor size, pathologic Masaoka stage, resection status, and use of chemotherapy. OS was the primary end point using the Kaplan-Meier method. Time to recurrence (TTR) was the secondary end point using a competing risk analysis. A 3-month landmark analysis was performed. RESULTS: PORT was associated with a significant OS benefit (5-y OS 68% versus 53%, p = 0.002). In patients with R0 resection, PORT was associated with increased OS for advanced (stages III-IV, p = 0.04), but not early (stages I-II, p = 0.14) stage TC. In patients with an R1/2 resection of advanced-stage TC, PORT was associated with significantly longer OS (5-y OS 53% versus 38%; p < 0.001). Subset analyses did not reveal clear associations of PORT with TTR. On multivariable analysis, lower pathologic stage, PORT, and R0 resection status were associated with an OS benefit, whereas only higher age and lower pathologic stage had an association with longer TTR. CONCLUSIONS: In the largest individual patient data set on patients with TC reported to date, PORT was associated with a meaningful OS benefit in patients with advanced-stage TC after an R0 or R1/2 resection.