Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Circ J ; 84(5): 786-791, 2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32238666

RESUMO

BACKGROUND: The Harmonization By Doing (HBD) program was established in 2003 as a partnership among stakeholders of academia, industry and regulatory agencies in Japan and the United States, with a primary focus on streamlining processes of global medical device development for cardiovascular medical devices. While HBD has traditionally focused on development of devices intended to treat conditions prevalent in adults, in 2016, HBD established the "HBD-for-Children" program, which focuses on the development of pediatric devices as the development of medical devices for pediatric use lags behind that of medical devices for adults in both countries.Methods and Results:Activities of the program have included: (1) conducting a survey with industry to better understand the challenges that constrain the development of pediatric medical devices; (2) categorizing pediatric medical devices into five categories based on global availability and exploring concrete solutions for the early application and regulatory approval in both geographies; and (3) facilitating global clinical trials of pediatric medical devices in both countries. CONCLUSIONS: The establishment of the HBD-for-Children program is significant because it represents a global initiative for the introduction of pediatric medical devices for patients in a timely manner. Through the program, academia, industry and regulatory agencies can work together to facilitate innovative pediatric device development from a multi-stakeholder perspective. This activity could also encourage industry partners to pursue the development of pediatric medical devices.


Assuntos
Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/instrumentação , Doenças Cardiovasculares/terapia , Comportamento Cooperativo , Desenho de Equipamento , Equipamentos e Provisões , Cooperação Internacional , Pediatria/instrumentação , Parcerias Público-Privadas , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/fisiopatologia , Humanos , Japão , Avaliação de Programas e Projetos de Saúde , Participação dos Interessados , Estados Unidos
2.
J Cardiothorac Vasc Anesth ; 34(8): 2215-2223, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32127273

RESUMO

Anticoagulation is an essential component for patients undergoing cardiopulmonary bypass or extracorporeal membrane oxygenation and for those with ventricular assist devices. However, thrombosis and bleeding are common complications. Heparin continues to be the agent of choice for most patients, likely owing to practitioners' comfort and experience and the ease with which the drug's effects can be reversed. However, especially in pediatric cardiac surgery, there is increasing interest in using bivalirudin as the primary anticoagulant. This drug circumvents certain problems with heparin administration, such as heparin resistance and heparin-induced thrombocytopenia, but it comes with additional challenges. In this manuscript, the authors review the literature on the emerging role of bivalirudin in pediatric cardiac surgery, including its use with cardiopulmonary bypass surgery, extracorporeal membrane oxygenation, ventricular assist devices, and interventional cardiology. Moreover, they provide an overview of bivalirudin's pharmacodynamics and monitoring methods.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiologia , Anticoagulantes/efeitos adversos , Ponte Cardiopulmonar , Criança , Heparina/efeitos adversos , Hirudinas , Humanos , Fragmentos de Peptídeos , Proteínas Recombinantes
3.
Cardiol Young ; 30(1): 50-54, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31771681

RESUMO

BACKGROUND: Although widely used in cardiology, relation of heart failure biomarkers to cardiac haemodynamics in patients with CHD (and in particular with pulmonary insufficiency undergoing pulmonary valve replacement) remains unclear. We hypothesised that the cardiac function biomarkers N-terminal pro-brain natriuretic peptide (NT-proBNP), soluble suppressor of tumorigenicity 2, and galectin-3 would have significant associations to right ventricular haemodynamic derangements. METHODS: Consecutive patients ( n = 16) undergoing cardiac catheterisation for transcatheter pulmonary valve replacement were studied. NT-proBNP, soluble suppressor of tumorigenicity 2, and galectin-3 levels were measured using a multiplex enzyme-linked immunosorbent assay from a pre-intervention blood sample obtained after sheath placement. Spearman correlation was used to identify significant correlations (p ≤ 0.05) of biomarkers with baseline cardiac haemodynamics. Cardiac MRI data (indexed right ventricular and left ventricular end-diastolic volumes and ejection fraction) prior to device placement were also compared to biomarker levels. RESULTS: NT-proBNP and soluble suppressor of tumorigenicity 2 were significantly correlated (p < 0.01) with baseline mean right atrial pressure and right ventricular end-diastolic pressure. Only NT-proBNP was significantly correlated with age. Galectin-3 did not have significant associations in this cohort. Cardiac MRI measures of right ventricular function and volume were not correlated to biomarker levels or right heart haemodynamics. CONCLUSIONS: NT-proBNP and soluble suppressor of tumorigenicity 2, biomarkers of myocardial strain, significantly correlated to invasive pressure haemodynamics in transcatheter pulmonary valve replacement patients. Serial determination of soluble suppressor of tumorigenicity 2, as it was not associated with age, may be superior to serial measurement of NT-proBNP as an indicator for timing of pulmonary valve replacement.


Assuntos
Insuficiência Cardíaca/sangue , Hemodinâmica , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Insuficiência da Valva Pulmonar/sangue , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Biomarcadores/sangue , Cateterismo Cardíaco , Criança , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca , Ventrículos do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Adulto Jovem
4.
Circulation ; 131(19): 1656-64, 2015 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-25869198

RESUMO

BACKGROUND: The Coarctation of the Aorta Stent Trial (COAST) was designed to assess the safety and efficacy of the Cheatham Platinum stent when used in children and adults with native or recurrent coarctation. Acute outcomes have been reported. We report here follow-up to 2 years. METHODS AND RESULTS: A total of 105 patients underwent attempted implantation, with 104 successes. There were no procedural deaths, serious adverse events, or surgical intervention. All patients experienced immediate reduction in upper- to lower-extremity blood pressure difference with sustained improvement to 2 years. Rates of hypertension and medication use decreased from baseline to 12 months and remained largely unchanged at 2 years. Six aortic aneurysms have been identified: 5 were successfully treated with covered stent placement, and 1 resolved without intervention. Stent fractures were noted in 2 patients at 1 year and 11 patients at 2 years, with evidence of fracture progression. To date, only larger stent diameter was associated with stent fracture. Twelve additional fractures have occurred after 2 years. No fracture has resulted in loss of stent integrity, stent embolization, aortic wall injury, or reobstruction. Nine reinterventions occurred in the first 2 years for stent redilation and address of aneurysms, and 10 additional reinterventions occurred after 2 years. CONCLUSIONS: The Cheatham Platinum stent is safe and associated with persistent relief of aortic obstruction. Stent fracture and progression of fracture occur but have not resulted in clinically important sequelae. Reintervention is common and related to early and late aortic wall injury and need for re-expansion of small-diameter stents. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00552812.


Assuntos
Angioplastia com Balão , Coartação Aórtica/terapia , Stents , Adulto , Dissecção Aórtica/etiologia , Angioplastia com Balão/instrumentação , Anti-Hipertensivos/uso terapêutico , Aorta/lesões , Aneurisma Aórtico/etiologia , Coartação Aórtica/diagnóstico por imagem , Aortografia , Cateterismo Cardíaco/efeitos adversos , Criança , Falha de Equipamento , Artéria Femoral/lesões , Seguimentos , Migração de Corpo Estranho/epidemiologia , Migração de Corpo Estranho/etiologia , Hemodinâmica , Humanos , Hipertensão/complicações , Hipertensão/tratamento farmacológico , Platina , Estudos Prospectivos , Reoperação , Stents/efeitos adversos , Resultado do Tratamento
5.
Circulation ; 132(20): 1863-70, 2015 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-26481778

RESUMO

BACKGROUND: As US health care increasingly focuses on outcomes as a means for quantifying quality, there is a growing demand for risk models that can account for the variability of patients treated at different hospitals so that equitable comparisons between institutions can be made. We sought to apply aspects of prior risk-standardization methodology to begin development of a risk-standardization tool for the National Cardiovascular Data Registry (NCDR) IMPACT (Improving Pediatric and Adult Congenital Treatment) Registry. METHODS AND RESULTS: Using IMPACT, we identified all patients undergoing diagnostic or interventional cardiac catheterization between January 2011 and March 2013. Multivariable hierarchical logistic regression was used to identify patient and procedural characteristics predictive of experiencing a major adverse event after cardiac catheterization. A total of 19,608 cardiac catheterizations were performed between January 2011 and March 2013. Among all cases, a major adverse event occurred in 378 of all cases (1.9%). After multivariable adjustment, 8 variables were identified as critical for risk standardization: patient age, renal insufficiency, single-ventricle physiology, procedure-type risk group, low systemic saturation, low mixed venous saturation, elevated systemic ventricular end-diastolic pressure, and elevated main pulmonary artery pressures. The model had good discrimination (C statistic, 0.70), confirmed by bootstrap validation (validation C statistic, 0.69). CONCLUSIONS: Using prior risk-standardization efforts as a foundation, we developed and internally validated a model to predict the occurrence of a major adverse event after cardiac catheterization for congenital heart disease. Future efforts should be directed toward further refinement of the model variables within this large, multicenter data set.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/epidemiologia , Pediatria/normas , Sistema de Registros/normas , Relatório de Pesquisa/normas , Adolescente , Cateterismo Cardíaco/normas , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Cardiopatias Congênitas/terapia , Humanos , Lactente , Recém-Nascido , Masculino , Fatores de Risco , Estados Unidos/epidemiologia , Adulto Jovem
6.
Cardiol Young ; 26(1): 70-8, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25705856

RESUMO

OBJECTIVES: To report procedural characteristics and adverse events on data collected in the registry. BACKGROUND: The IMPACT--IMproving Paediatric and Adult Congenital Treatment--Registry is a catheterisation registry of paediatric and adult patients with CHD undergoing diagnostic and interventional cardiac catheterisation. We are reporting the procedural characteristics and adverse events of patients undergoing diagnostic and interventional catheterisation procedures from January, 2011 to March, 2013. METHODS: Demographic, clinical, procedural, and institutional data elements were collected at the participating centres and entered via either a web-based platform or software provided by American College of Cardiology-certified vendors, and were collected in a secure, centralised database. Centre participation was voluntary. RESULTS: During the time frame of data collection, 19,797 procedures were entered into the IMPACT Registry. Procedures were classified as diagnostic only (35.4%); one of six specific interventions (23.8%); other or multiple interventions (40.7%); and were further broken down into four age groups. Anaesthesia was used in 84.1% of diagnostic procedures and 87.8% of interventional ones. Adverse events occurred in 10.0% of diagnostic and 11.1% of interventional procedures. CONCLUSIONS: The IMPACT Registry is gathering data to set national benchmarks for diagnostic and certain specific interventional procedures. We are seeing little differences in procedural characteristics or adverse events in diagnostic procedures compared with interventional procedures overall, but there is significant variation in adverse events amongst age categories. Risk stratification and patient acuity scores will be required for further analysis of these differences.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Adulto , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Sistema de Registros
7.
Cardiol Young ; 26(6): 1202-12, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26455737

RESUMO

OBJECTIVES: The objective of this study was to report procedural characteristics and adverse events on the data collected in the IMproving Paediatric and Adult Congenital Treatment registry. BACKGROUND: The IMproving Paediatric and Adult Congenital Treatment- registry is a catheterisation registry focussed on paediatric and adult patients with congenital heart disease who are undergoing diagnostic catheterisations and catheter-based interventions. This study reports procedural characteristics and adverse events of patients who have undergone selected catheterisation procedures from January, 2011 to June, 2013. METHODS: Demographic, clinical, procedural, and institutional data elements were collected at participating centres and entered via either a web-based platform or software provided by the American College of Cardiology-certified vendors, and were collected in a secure, centralised database. For the purpose of this study, procedures that were not classified as one of the 'core' IMproving Paediatric and Adult Congenital Treatment procedures originally chosen for additional data collection were identified and selected for further data analysis. RESULTS: During the time frame of data collection, a total of 8021 cases were classified as other procedures and/or multiple procedures. The most commonly performed case types - isolated or in combination with other procedures - were right ventricular biopsy in 3433 (42.8%), conduit/MPA interventions in 979 (12.3%), and systemic pulmonary artery collateral occlusion in 601 (7.5%). For the whole cohort, adverse events of any severity occurred in 957 (12.0%) cases, whereas major adverse events occurred in 113 (1.4%) cases; six patients (0.1%) died in the catheterisation laboratory. CONCLUSIONS: The IMproving Paediatric and Adult Congenital Treatment registry has provided important data on the frequency and spectrum of cardiac catheterisation procedures performed in the present era. For many procedures, more data and work are needed to identify more subtle differences between case categories, especially as it relates to the incidence of major adverse events, and to further develop a risk-adjustment methodology to allow equitable comparisons among institutions.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Cateteres Cardíacos/efeitos adversos , Cardiologia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Adolescente , Criança , Pré-Escolar , Bases de Dados Factuais , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Sistema de Registros , Estados Unidos
8.
Catheter Cardiovasc Interv ; 85(3): 421-7, 2015 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25257401

RESUMO

OBJECTIVE: Retrospectively assess the frequency of right ventricular outflow tract (RVOT) conduit disruption during transcatheter pulmonary valve replacement (TPVR) and the effectiveness and safety of NuMED Covered Cheatham-Platinum Stents™ (CCPS) for its prevention or treatment. BACKGROUND: There have been no published reports to date describing the safety and effectiveness of covered stents to prevent or treat RVOT conduit disruption during TPVR. METHODS: Data regarding 251 TPVR procedures performed at multiple US investigational sites were retrospectively reviewed to explore the incidence and potential predictors of conduit disruption. In addition, data on the use of 69 CCPS implanted in 50 patients during TPVR was reviewed. RESULTS: The overall incidence of conduit disruption requiring intervention was 6%. The only predictor identified was a very elevated RVOT conduit systolic pressure gradient. A pre-existing conduit tear was present in nine, while 31 developed tears after conduit dilation and three, after TPVR. The CCPS was used prophylactically in seven. Conduit tears were prevented or repaired in 49/50 patients. No CCPS-related acute complications were reported. At 6-month follow-up, no patient had more than mild pulmonary regurgitation and the mean Doppler RVOT gradient (12.7 ± 5.8 mm Hg) comparing favorably with that reported in the Melody TPV® IDE trial (20.0 ± 8.6 mm Hg). CONCLUSION: CCPS implantation can successfully treat RVOT conduit disruption without negative impact on the TPV function. This retrospective analysis suggests high RVOT conduit systolic pressure gradient is a risk factor for conduit tears during TPVR.


Assuntos
Implante de Prótese Vascular/efeitos adversos , Cateterismo Cardíaco/métodos , Materiais Revestidos Biocompatíveis , Procedimentos Endovasculares/instrumentação , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Platina , Valva Pulmonar/cirurgia , Stents , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Obstrução do Fluxo Ventricular Externo/terapia , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Procedimentos Endovasculares/efeitos adversos , Feminino , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Valva Pulmonar/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
9.
Catheter Cardiovasc Interv ; 86(1): 85-93, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25809590

RESUMO

With the evolution of transcatheter valve replacement, an important opportunity has arisen for cardiologists and surgeons to collaborate in identifying the criteria for performing these procedures. Therefore, The Society for Cardiovascular Angiography and Interventions (SCAI), American Association for Thoracic Surgery (AATS), American College of Cardiology (ACC), and The Society of Thoracic Surgeons (STS) have partnered to provide recommendations for institutions to assess their potential for instituting and/or maintaining a transcatheter valve program. This article concerns transcatheter pulmonic valve replacement (tPVR). tPVR procedures are in their infancy with few reports available on which to base an expert consensus statement. Therefore, many of these recommendations are based on expert consensus and the few reports available. As the procedures evolve, technology advances, experience grows, and more data accumulate, there will certainly be a need to update this consensus statement. The writing committee and participating societies believe that the recommendations in this report serve as appropriate requisites. In some ways, these recommendations apply to institutions more than to individuals. There is a strong consensus that these new valve therapies are best performed using a Heart Team approach; thus, these credentialing criteria should be applied at the institutional level. Partnering societies used the ACC's policy on relationships with industry (RWI) and other entities to author this document (http://www.acc.org/guidelines/about-guidelines-and-clinical-documents). To avoid actual, potential, or perceived conflicts of interest due to industry relationships or personal interests, all members of the writing committee, as well as peer reviewers of the document, were asked to disclose all current healthcare-related relationships including those existing 12 months before the initiation of the writing effort. A committee of interventional cardiologists and surgeons was formed to include a majority of members with no relevant RWI and to be led by an interventional cardiology cochair and a surgical cochair with no relevant RWI. Authors with relevant RWI were not permitted to draft or vote on text or recommendations pertaining to their RWI. RWI were reviewed on all conference calls and updated as changes occurred. Author and peer reviewer RWI pertinent to this document are disclosed in the Appendices. In addition, to ensure complete transparency, authors' comprehensive disclosure information (including RWI not pertinent to this document) is available in Appendix AII. The work of the writing committee was supported exclusively by the partnering societies without commercial support. SCAI, AATS, ACC, and STS believe that adherence to these recommendations will maximize the chances that these therapies will become a successful part of the armamentarium for treating valvular heart disease in the United States. In addition, these recommendations will hopefully facilitate optimum quality during the delivery of this therapy, which will be important to the development and successful implementation of future, less invasive approaches to structural heart disease.


Assuntos
Cateterismo Cardíaco/normas , Cardiologia/normas , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/normas , Guias de Prática Clínica como Assunto , Valva Pulmonar/cirurgia , Sociedades Médicas , American Heart Association , Humanos , Estados Unidos
10.
Pediatr Cardiol ; 35(7): 1124-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24723210

RESUMO

This study aimed to assess the technical aspects of atrial septal defect (ASD) closure using the Amplatzer septal occluder (ASO) and the Gore Helex septal occluder (GHSO) for infants weighing less than 8 kg and to determine the safety, effectiveness, and near-to-intermediate-term outcome of the closure. The Mid-Atlantic Group of Interventional Cardiology Registry of percutaneous, transcatheter ASD closure procedures was reviewed for this analysis. Patients from 10 hospitals in the United States were included. The cohort for this report consisted of 68 patients weighing less than 8 kg (range, 2.3-7.8 kg; mean, 5.5 ± 1.6 kg) and ranging in age from 1 to 24 months (mean, 8.6 ± 4.7 months). The indications for ASD closure were failure to thrive, significant right heart enlargement, shunts otherwise thought to be hemodynamically significant, and poor overall clinical status. Devices were successfully implanted in 66 of the 68 infants (97.1 % procedural success rate). Five minor procedure-related complications occurred. At follow-up assessment, clinical status had improved significantly as measured by improved weight gain and decreased ventilator or oxygen dependence. All residual shunts spontaneously closed during the follow-up period. Six late deaths occurred, none of which were clearly device related. The ASO and GHSO can be safely and effectively implanted for ASD closure in infants weighing less than 8 kg. These procedures usually are successful and seldom complicated, resulting in significant clinical improvement.


Assuntos
Peso Corporal , Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal , Pré-Escolar , Ecocardiografia , Feminino , Fluoroscopia , Seguimentos , Comunicação Interatrial/diagnóstico , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 82(4): 503-10, 2013 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-23592408

RESUMO

OBJECTIVES: The coarctation of the aorta stent trial (COAST) is a pivotal trial of the NuMED Cheatham Platinum Stent(®) for treatment of coarctation of the aorta (CoA). BACKGROUND: CoA is a congenital obstruction to flow through the aorta. Stents have been used since the 1990s to treat CoA; none have been approved by the Food and Drug Administration for this indication. METHODS: In a prospective, multicenter study 105 patients received stents for treatment of CoA. Data was collected in the catheterization laboratory, on discharge and at 1-month postprocedure. RESULTS: Of 105 patients, 69% were male; 57% had native CoA. Noninvasive, baseline systolic blood pressure (SBP) showed upper extremity (UE) SBP to be 140 ± 16 mm Hg and UE to lower extremity (LE) SBP difference 29 ± 17 mm Hg. At catheterization, baseline ratio of minimum CoA diameter to diameter of descending aorta (CoA:DAo) was 0.46 ± 0.16. Implants (104/105) were successful with one stent migration. There were no deaths or serious complications. Paradoxical hypertension occurred in 6%. Four percent of patients experienced somewhat serious adverse events related to the procedure. All patients achieved relief of ascending aorta to Dao pressure gradient: mean = 2.0 ± 4.0 mm Hg (P < 0.001). The CoA:DAo increased to 0.84 ± 0.18. At 1-month, UE SBP was 120 ± 12 mm Hg, UE to LE SBP difference = -1 ± 12 mm Hg. Ninety-nine percent of patients had UE to LE SBP difference <20 mm Hg. CONCLUSIONS: Stenting of CoA, using the NuMED Cheatham Platinum Stent, is acutely safe and effective for treatment of CoA.


Assuntos
Angioplastia com Balão/instrumentação , Coartação Aórtica/terapia , Stents , Adolescente , Adulto , Angioplastia com Balão/efeitos adversos , Coartação Aórtica/diagnóstico , Coartação Aórtica/fisiopatologia , Pressão Sanguínea , Cateterismo Periférico , Criança , Feminino , Humanos , Hipertensão/fisiopatologia , Hipertensão/terapia , Masculino , Pessoa de Meia-Idade , Platina , Estudos Prospectivos , Desenho de Prótese , Recidiva , Fluxo Sanguíneo Regional , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
12.
Pediatr Cardiol ; 34(4): 809-16, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23080541

RESUMO

Dilation of the sinus of Valsalva (SoV) has been increasingly observed after repaired tetralogy of Fallot (TOF). We estimate the prevalence of SoV dilation in adults with repaired TOF and analyze possible factors related to aortic disease. Adults with TOF [n = 109, median age 33.2 years (range 18.1 to 69.5)] evaluated at Johns Hopkins Hospital from 2001 to 2009 were reviewed in an observational retrospective cohort study. Median follow-up was 27.3 (range 0.1-48.8) years. SoV dilation was defined as >95 % confidence interval adjusted for age and body surface area (z-score > 2). The prevalence of SoV dilation was 51 % compared with that of a normal population with a mean z-score of 2.03. Maximal aortic diameters were ≥ 4 cm in 39 % (42 of 109), ≥ 4.5 cm in 21 % (23 of 109), ≥ 5 cm in 8 % (9 of 109), and ≥ 5.5 cm in 2 % (2 of 109). There was no aortic dissection or death due contributable to aortic disease. Aortic valve replacement was performed in 1.8 % and aortic root or ascending aorta (AA) replacement surgery in 2.8 % of patients. By multivariate logistic regression analysis, aortic regurgitation (AR) [odds ratio (OR) = 3.09, p = 0.005], residual ventricular septal defect (VSD) (OR = 4.14, p < 0.02), and TOF with pulmonary atresia (TOF/PA) (OR = 6.75, p = 0.03) were associated with increased odds of dilated aortic root. SoV dilation after TOF repair is common and persists with aging. AR, residual VSD, and TOF/PA are associated with increased odds of dilation. AA evaluation beyond the SoV is important. Indexed values are imperative to avoid bias on the basis of age and body surface area.


Assuntos
Doenças da Aorta/etiologia , Doenças da Aorta/patologia , Complicações Pós-Operatórias/patologia , Seio Aórtico/patologia , Tetralogia de Fallot/cirurgia , Adolescente , Adulto , Idoso , Doenças da Aorta/diagnóstico por imagem , Dilatação Patológica , Progressão da Doença , Ecocardiografia , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Prevalência , Estudos Retrospectivos , Tetralogia de Fallot/complicações , Tetralogia de Fallot/fisiopatologia
13.
Am Heart J ; 164(1): 7-13, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22795276

RESUMO

BACKGROUND: Coarctation of the aorta (CoA) accounts for 4% to 5% of congenital cardiac abnormalities. Stent therapy has become an accepted alternative to surgery for older children and adults, although there are no balloon-expandable stents approved by the Food and Drug Administration for use in the aorta. The Cheatham-Platinum (CP) stent was designed for CoA therapy and is widely used outside the United States. We have designed the first prospective trial of stent therapy for CoA to serve as the pivotal trial for Food and Drug Administration approval of the CP stent. METHODS: The COAST study is a prospective, multicenter, single-arm clinical study. The population includes patients with native or recurrent CoA. Four primary outcome variables were defined. For each variable, the stent will be compared to performance guidelines derived from surgical experience. The first efficacy outcome is reduction in arm-leg systolic blood pressure gradient, and the second is reduction in hospital length of stay. Safety outcomes include the following: the occurrence of any serious or somewhat serious adverse event attributed to the stent or implantation procedure and the occurrence of postprocedure paradoxical hypertension. A total of 105 patients treated with the CP stent will be enrolled. DISCUSSION: To ascertain the effectiveness and safety of an interventional device, randomized controlled trials have been offered as the criterion standard. However, these trials are not well suited to study rare conditions such as CoA, especially once the therapy in question has received acceptance within the medical community. New clinical trial and statistical approaches are needed to evaluate such therapies. The COAST study is an example of this kind of innovative trial design.


Assuntos
Coartação Aórtica/cirurgia , Stents , Ensaios Clínicos como Assunto/métodos , Humanos , Estudos Prospectivos
14.
Circ Cardiovasc Interv ; 14(6): e010308, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34039015

RESUMO

BACKGROUND: Long-term outcome data of stent-implantation for coarctation of the aorta are limited. We report up to 5 years of postimplant follow-up in patients enrolled into the COAST (Coarctation of the Aorta Stent Trial) and the COAST II trial (Covered Cheatham-Platinum Stents for Prevention or Treatment of Aortic Wall Injury Associated With Coarctation of the Aorta), evaluating the bare and Covered Cheatham-Platinum Stents for the treatment of coarctation of the aorta and associated aortic wall injury. METHODS: Data was prospectively collected during the 2 multi-center studies, enrolling 248 patients (COAST: n=121, COAST II: n=127). Late follow-up data (48­60 month) was compared with immediate (1 month) and early (12 months) follow-up. RESULTS: There was a notable decrease in the use of antihypertensive medication, from 53% at immediate, to 42% at early, and 29% at late follow-up. The cumulative incidence of stent fractures was 0% immediately, 2.9% at early, and 24.4% at late follow-up. Independent predictors for stent fractures at late follow-up were age <18 years, male sex, minimum stent diameter ≥12 mm, and use of bare metal stent. The cumulative incidence of reintervention was 1.6% at immediate, 5.1% at early, and 21.3% at late follow-up. Independent predictors for reinterventions at late follow-up were age <18 years, post implantation systolic arm-leg blood pressure gradient ≥10 mm Hg, minimum stent diameter at implantation <12 mm, and initial coarctation minimum diameter <6 mm. There were 13 patients with aortic aneurysms, with a cumulative incidence of 6.3% at late follow-up. CONCLUSIONS: Coarctation stenting is effective at maintaining obstruction relief up to 60 months postimplant with reduction in the number of patients requiring antihypertensive medication. However, an increase in-stent fractures and reinterventions were observed between medium and long-term follow-up. Covered stents appear to confer some protection from the development of stent fractures but do not provide complete protection from late aneurysm formation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT00552812 and NCT01278303.


Assuntos
Aneurisma Aórtico , Coartação Aórtica , Adolescente , Aorta , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Humanos , Masculino , Stents , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 76(5): 696-702, 2010 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-20690153

RESUMO

BACKGROUND: There are no guidelines and multiple devices available now for closure of PDA. OBJECTIVE: We sought to determine which devices are used and their outcomes. METHODS: Prospectively collected data on closure of PDA at 12 US catheterization labs was entered into the MAGIC data registry between November 2005 and September 2008. RESULTS: PDA closure was accomplished in 357 of 359 attempted closures during the study period. Mean age, weight, and minimum ductal diameter were 4.3 ± 6.8 years, 18.7 ± 18.4 kg, and 2.1 ± 1.4 mm, respectively. Devices used were Gianturco coils (161/359), Amplatzer Duct Occluder (ADO, 174/359), Flipper coils (18/359), and other devices (6/359). Gianturco coils had the least fluoroscopy and contrast exposure (8.7 ± 7.5 min, P = 0.00001, 2.6 ± 1.4 cm(3) kg(-1), P = 0.00001). Immediate angiographic success rates were 96.9% (156/161) for Gianturco coils, 89.7% (156/174) for the ADO, 100% (18/18) for Flipper coils, and 66.7% (4/6) for other devices. Major complication rates were 0.6% for Gianturco coils (1/161), 1.7% for ADO (3/174), and 83.3% for other devices (4/6). Minor complication rates by device were 1.9% for Gianturco coils (3/161), 2.3% for ADO (4/174), and 16.7% (1/6) for other devices. CONCLUSIONS: Gianturco coils, the ADO and Flipper coils were immediately successful with low complication profiles. The ADO and Gianturco coils were the predominate devices. The ADO was the device of choice for PDA > 3 mm with good success. In PDA < 3 mm, the Gianturco coil is as effective and safe as the ADO with less cost, less radiation, and less contrast exposure. © 2010 Wiley-Liss, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Humanos , Lactente , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Desenho de Prótese , Doses de Radiação , Radiografia Intervencionista , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
16.
Artigo em Inglês | MEDLINE | ID: mdl-20307857

RESUMO

Tremendous advances have occurred in catheter-based interventions for congenital heart disease. Multicenter trials of these advances are either out of date or have been limited in scope. As such little is known on the application of these techniques in the current era. The IMPACT Registry (IMproving Pediatric and Adult Congenital Treatments) will allow us to measure variability in the performance and outcomes of both diagnostic and interventional cardiac catheterization procedures in all children and adults with congenital heart disease. The IMPACT Registry will be harmonized with the Society of Thoracic Surgeons Congenital Heart Disease Database, thereby allowing us to compare catheter-based interventions with surgical interventions when appropriate. The initial release of the registry will only include hospital-based outcomes, but ultimately it will transition to a longitudinal registry. The IMPACT Registry will provide the necessary benchmark tools for quality improvement activities for cardiac catheterization procedures in congenital heart disease.


Assuntos
Benchmarking/organização & administração , Cateterismo Cardíaco , Cardiopatias Congênitas/terapia , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros , Adulto , Angioplastia Coronária com Balão/estatística & dados numéricos , Criança , Saúde Global , Cardiopatias Congênitas/diagnóstico , Humanos , Avaliação de Resultados em Cuidados de Saúde/organização & administração , Sistema de Registros/normas , Stents
17.
Pediatr Cardiol ; 30(3): 240-7, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19015911

RESUMO

The objective of this study was to determine the initial safety and results of unrestricted multi-institution routine community use of the Amplatzer Septal Occluder (ASO) for atrial septal defect (ASD) closure. A multicenter, nonrandomized prospective study was performed in 13 pediatric cardiology centers from November 2004 to September 2007. Data were collected at the time of cardiac catheterization and 1 day postimplant. Four hundred seventy-eight patients underwent cardiac catheterization for ASO device closure of an ASD. The median age was 6 years (range, <1-83 years), and the mean weight was 37.2 kg (range, 2.6-148 kg). Procedural success was 96% (458/478 patients), with deficient rims being the major single reason for failed implantation (9/20). Major and minor complication rates were 1.1% and 4.8%, respectively, and were not different between simple and complex ASD groups. Success at 24 h was 99.4% (333/335) in the simple ASD group and 100% (120/120) in the complex ASD group. The presence of large defects, the presence of multiple defects, the use of multiple devices, and a weight <8 kg were significantly associated with a residual shunt (small to moderate) at 24 h. In conclusion, the ASO device in routine clinical practice for simple and complex ASD closure has an immediate safety and effectiveness profile equal to that reported in the initial pivotal FDA trial for simple ASDs. Based on the evolution in care posed by the ASO and the lack of consensus on patient selection in complex ASDs, this study points out the need to redefine the optimal patient and possibly broaden the indications for device closure of ASDs.


Assuntos
Embolização Terapêutica/instrumentação , Comunicação Interatrial/terapia , Hospitais Comunitários/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Oclusão com Balão/instrumentação , Criança , Pré-Escolar , Ecocardiografia , Desenho de Equipamento , Fluoroscopia , Seguimentos , Comunicação Interatrial/diagnóstico , Humanos , Lactente , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Estados Unidos , Adulto Jovem
18.
Circ Cardiovasc Interv ; 11(10): e006598, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30354627

RESUMO

BACKGROUND: High-pressure balloon and stent angioplasty are frequently necessary to prepare the dysfunctional right ventricular outflow tract conduit before transcatheter pulmonary valve replacement (TPVR). Conduit injury can result, which may be catastrophic to the patient or prevent successful TPVR. METHODS AND RESULTS: The PARCS trial (Pulmonary Artery Repair With Covered Stent) was a pivotal, prospective multicenter trial to evaluate the safety and efficacy of the NuMED Covered CP Stent (CCPS) for treatment of conduit injury occurring during TPVR. The study also evaluated immediate and short-term TPVR function in patients receiving covered stents. A total of 616 patients were consented; 120 (19.5%) had a wall injury identified and were treated with CCPS. Severe conduit injuries were uncommon (5%), but predictors for severe injury were not identified. Stenotic homografts had the highest incidence of injury (29%), compared with other conduit substrates. Among patients receiving CCPS implant, 96% required no further therapy for conduit injury, and 94% underwent TPVR at that procedure. Only 2 patients (1.6%) required urgent surgery for conduit injury, despite CCPS implant. There were few CCPS-related complications. TPVR function was similar between CCPS and non-CCPS groups at follow-up. CONCLUSIONS: Conduit injury during TPVR is common, although severe injury is rare. The CCPS was a safe and effective treatment for right ventricular outflow tract conduit injury during preparation for TPVR, allowing nearly all patients to complete the procedure without identifiable impact on valve performance. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01824160.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cardiopatias Congênitas/cirurgia , Traumatismos Cardíacos/terapia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Stents , Adolescente , Adulto , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Criança , Feminino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
20.
Cureus ; 9(12): e1928, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29464136

RESUMO

Survival rates for patients with palliated congenital heart disease are increasing, and an increasing number of adults with cyanotic congenital heart disease (CCHD) might require surgical resection of pheochromocytoma-paraganglioma (PHEO-PGL). A recent study supports the idea that patients with a history of CCHD and current or historical cyanosis might be at increased risk for developing PHEO-PGL. We review the anesthetic management of two adults with single-ventricle physiology following Fontan palliation presenting for PHEO-PGL resection and review prior published case reports. We found the use of epidural analgesia to be safe and effective in the operative and postoperative management of our patients.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa