Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Neuroradiology ; 60(9): 889-901, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30066278

RESUMO

PURPOSE: New software solutions emerged to support radiologists in image interpretation in acute ischemic stroke. This study aimed to validate the performance of computer-aided assessment of the Alberta Stroke Program Early CT score (ASPECTS) for detecting signs of early infarction. METHODS: ASPECT scores were assessed in 119 CT scans of patients with acute middle cerebral artery ischemia. Patient collective was differentiated according to (I) normal brain, (II) leukoencephalopathic changes, (III) infarcts, and (IV) atypical parenchymal defects (multiple sclerosis, etc.). ASPECTS assessments were automatically provided by the software package e-ASPECTS (Brainomix®, UK) (A). Subsequently, three neuroradiologists (B), (C), and (D) examined independently 2380 brain regions. Interrater comparison was performed with the definite infarct core as reference standard after best medical care (thrombolysis and/or thrombectomy). RESULTS: Interrater comparison revealed higher correlation coefficient of (B) 0.71, (C) 0.76, and of (D) 0.80 with definite infarct core compared to (A) 0.59 for ASPECTS assessment in the acute ischemic stroke setting. While (B), (C), and (D) showed a significant correlation for individual patient groups (I), (II), (III), and (IV), except for (D) (II), (A) was not significant in patient groups with pre-existing changes (II), (III), and (IV). The following sensitivities, specificities, PPV, NPV, and accuracies given in percent were achieved: (A) 83, 57, 55, 82, and 67; (B) 74, 76, 69, 83, and 77; (C) 80.8, 85.2, 76, 84, and 80; (D) 63, 90.7, 82, 79, and 80, respectively. CONCLUSION: For ASPECTS assessment, the examined software may provide valid data in case of normal brain. It may enhance the work of neuroradiologists in clinical decision making. A final human check for plausibility is needed, particularly in patient groups with pre-existing cerebral changes.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Aprendizado de Máquina , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Alberta , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Software
2.
Am J Otolaryngol ; 38(6): 649-653, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28942233

RESUMO

PURPOSE: To examine radiation-doses imparted during multislice (MSCT) and cone-beam computed-tomography (CBCT) for perioperative examination of cochlear-implant insertion. METHODS: Radiation-doses were assessed during standardized petrous-bone CT-protocols at different MSCT ((I) single-source CT-scanner Somatom-Definition-AS+, (II) 2nd generation of dual-source CT-scanner Somatom-Definition-Flash, (III) 3rd generation of dual-source CT-scanner Somatom-Force and at the CBCT Ziehm-Vision-RFD3D ((IV) (a) RFD-3D (Standard-modifier), (b) RFD-3D (Low-dose-modifier)). Image quality was examined by two radiologists appraising electrode-array placement, quality-control of cochlear-implant surgery and complications based on real patients' examinations (n=78). RESULTS: In MSCT-setting following radiation-doses were assessed (CTDIw; DLP): (I) 21.5mGy; 216mGycm; (II) 19.7mGy; 195mGycm; (III) 12.7mGy; 127mGycm; in the CBCT setting radiation doses were distributed as follows: (IV) (a) 1.9mGy; 19.4mGycm; (b) 1.2mGy; 12.9mGycm. Overall, image quality was evaluated as good for both, MSCT- and CBCT-examinations, with a good interrater reliability (r=0.81). CONCLUSION: CBCT bears considerable dose-saving potential for the perioperative examination of cochlear-implant insertion while maintaining adequate image quality.


Assuntos
Implante Coclear , Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomografia Computadorizada Multidetectores/instrumentação , Doses de Radiação , Implantes Cocleares , Humanos , Cuidados Intraoperatórios , Imagens de Fantasmas
3.
Eur Radiol ; 26(11): 4072-4079, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26943131

RESUMO

OBJECTIVES: To assess the impact of the scout view orientation on radiation exposure and image quality in thoracoabdominal CT, when automated tube voltage selection (ATVS) and automated tube current modulation (ATCM) are used in combination with scan planning on a single scout view. METHODS: Fifty patients underwent two thoracoabdominal CT examinations, one planned on an anteroposterior scout view, one planned on a lateral scout view. Both examinations included contrast-enhanced imaging of chest (CH) and abdomen (AB) and non-contrast-enhanced imaging of the liver (LI). For all examinations the same imaging protocol was used on the same dual-source CT scanner. The radiation exposure was recorded and objective as well as visual image quality was assessed for all examinations. RESULTS: The median dose-length product was significantly lower in scans planned on a lateral scout view (CH: 179 vs. 218 mGy*cm, LI: 148 vs. 178 mGy*cm, AB: 324 vs. 370 mGy*cm, p < 0.0001). Objective image quality was marginal lower in scans planned on a lateral scout view, whereas the visual image quality was rated as equal. CONCLUSION: At the tested radiation doses, the orientation of the scout view has a significant impact on the radiation exposure but no clinically relevant impact on the image quality. KEY POINTS: • The scout view orientation has a significant impact on the radiation exposure. • The scout view orientation has no clinically relevant impact on image quality. • A lateral scout view should be preferred with regard to radiation exposure.


Assuntos
Doses de Radiação , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Abdome/diagnóstico por imagem , Feminino , Humanos , Fígado , Masculino , Pessoa de Meia-Idade , Radiografia Abdominal/normas , Radiografia Torácica/normas , Reprodutibilidade dos Testes , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas
4.
Neuroradiology ; 58(7): 673-8, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26970990

RESUMO

INTRODUCTION: The purpose of this experimental phantom study was to compare radiation doses imparted to patients undergoing classical two-plane digital subtraction angiography (2-plane DSA) and 3D rotational angiography in interventional neuroradiology. METHODS: Thermoluminescence dosimeter (TLD) measurements were performed at an anthropomorphic phantom using a digital interventional angiography system. Two-plane DSA included posterior/anterior (PA) and lateral (LAT) projections (frame-rate, 7.6 frames (PA) and 9.8 frames (LAT) for a scan time of approximately 8 s; image intensifier 27 cm (PA) and 25 cm (LAT)). For 3D rotational angiography, 122 images were acquired from one single image run with the imaging system rotating 240° around the phantom's head (image intensifier 37 cm). RESULTS: Effective dose was 0.4 mSv for 2-plane DSA compared to 0.1 mSv for 3D rotational angiography. Organ doses were approximately two to five times higher for classical 2-plane technique compared to the 3D rotational angiography, respectively: brain (11.4 vs. 2.4 mSv), eye lens (4.5 vs.1 mSv), salivary glands (7 vs. 1,7 mSv), oral mucosa (2.7 vs.0.9 mSv), thyroid (0.5 vs. 0.2 mSv), thymus (0.2 vs. 0.05 mSv), bone marrow within imaged region (1 vs. 0.2 mSv), oesophagus (0.07 vs. 0.03 mSv), endotracheal system (2.6 vs. 0.7 mSv) and skeletal components in the imaged region (0.7 vs. 0.2 mSv). CONCLUSION: Three-dimensional rotational angiography clearly reduces radiation doses compared to the classical 2-plane technique. Replacement of additional 2-plane DSA projections with 3D rotational angiography will lead to a remarkable decrease in patient radiation dose, without loss of image quality. Thus, we recommend routine application of 3D rotational angiography, in particular for diagnostic assessment of aneurysm morphology.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação/análise , Angiografia Digital/instrumentação , Angiografia Cerebral/instrumentação , Angiografia por Tomografia Computadorizada/instrumentação , Feminino , Humanos , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente
5.
J Radiol Prot ; 36(4): N57-N66, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27642775

RESUMO

Various strategies have been developed to reduce radiation exposure of patients in CT examinations. The aim of this study was to evaluate the efficacy of high pitch in representative CT protocols examining lung embolism. We performed thermoluminescence measurements with an anthropomorphic phantom exposing it to CT algorithms for lung embolism in a 128-multislice, dual-source CT scanner: a standard CT protocol (sCT) and a CT protocol with a high pitch (+ F). Radiation doses for both CT algorithms were compared and the dose reduction potential of high pitch for individual organs was evaluated. As expected, the +F mode reduced the effective dose and organ doses in the primary beam of radiation (namely, lung, bone marrow, heart, breast, skin and skeleton) compared with sCT by up to 52% for an equivalent image quality. On the contrary, for organs at the margin of the primary beam (thymus, thyroid, liver, pancreas, kidneys, colon and small intestine), the +F mode reduced effective radiation doses by only 0-30%, compared with sCT. The dose reduction potential of the +F mode greatly depends on the position of the organ in the scan field. While for organs in the primary beam + F leads to a considerable dose reduction, it is less effective for tissues at the margin of the scanned area.


Assuntos
Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Imagens de Fantasmas , Dosimetria Termoluminescente
6.
Nervenarzt ; 84(6): 715-9, 2013 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-23695008

RESUMO

BACKGROUND: This study aimed to determine the value of digital subtraction angiography (DSA) for the detection of causative vascular lesions in patients with perimesencephalic subarachnoid hemorrhage (SAH) after initially negative noninvasive and invasive neurovascular imaging, such as computed tomography angiography (CTA), DSA and magnetic resonance angiography (MRA). MATERIALS AND METHODS: We analyzed the value of repeated DSA for the detection of causative vascular lesions in 750 patients presenting to our institution with SAH and including 30 with a purely perimesencephalic pattern of subarachnoidal hemorrhage and initially negative noninvasive and invasive neurovascular imaging over a 10-year period. RESULTS: Repeated DSA demonstrated a causative vascular lesion in 1 patient (3.3%) but no causative vascular lesions were detected in the other patients. CONCLUSIONS: Repeated DSA can be used to detect a source of hemorrhage after initially negative imaging diagnostics in some rare cases. Such a finding has a therapeutic and prognostic impact especially for aneurysms in the posterior circulation which bear a higher risk of renewed hemorrhaging. Therefore, we believe that repeated DSA should be recommended in patients with perimesencephalic SAH even under consideration of the risk of complications caused by a second invasive DSA.


Assuntos
Angiografia Digital/estatística & dados numéricos , Angiografia Cerebral/estatística & dados numéricos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Mesencéfalo/diagnóstico por imagem , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/epidemiologia , Tomografia Computadorizada por Raios X/estatística & dados numéricos , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Mesencéfalo/irrigação sanguínea , Prevalência , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
10.
Nervenarzt ; 80(12): 1496-51, 2009 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-19902166

RESUMO

BACKGROUND: We hypothesize that CNS immune reconstitution inflammatory syndrome (IRIS) after highly active antiretroviral therapy (HAART) in HIV-1-positive patients may become manifest without any opportunistic infection as an aseptic leucoencephalopathy. This opens a window of opportunity for successful treatment with corticosteroids. DESIGN: We describe a case series of immunocompromised HIV-1-positive patients who were started on HAART. All of them had clinical laboratory follow-up tests and cerebral MRI in order to investigate the course and the underlying pathophysiology of this aseptic form of IRIS. One African patient died and we performed a neuropathological examination. RESULTS: No infectious agent was detected before and during HAART. Three of four immunocompromised patients were successfully treated with corticosteroids while HAART was never interrupted and have survived up to now. One African patient died within 2 days despite intensive care due to cerebral oedema. CONCLUSIONS: Starting HAART, HIV-1-positive patients may develop an aseptic type of IRIS of the CNS without any detectable opportunistic infection, a finding that has not yet been published. This makes them susceptible for successful treatment with corticosteroids. Perhaps IRIS has a higher incidence in African patients and the patients have a poorer outcome than Caucasians.


Assuntos
Fármacos Anti-HIV/efeitos adversos , Terapia Antirretroviral de Alta Atividade/efeitos adversos , População Negra , Infecções por HIV/tratamento farmacológico , Síndrome Inflamatória da Reconstituição Imune/imunologia , Leucoencefalopatia Multifocal Progressiva/imunologia , População Branca , Corticosteroides/uso terapêutico , Adulto , Fármacos Anti-HIV/uso terapêutico , Evolução Fatal , Feminino , Infecções por HIV/imunologia , Infecções por HIV/virologia , HIV-1 , Humanos , Síndrome Inflamatória da Reconstituição Imune/tratamento farmacológico , Leucoencefalopatia Multifocal Progressiva/tratamento farmacológico , Masculino , Pessoa de Meia-Idade
11.
J Neurointerv Surg ; 10(2): 168-170, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28242653

RESUMO

BACKGROUND: A neurointerventional examination of intracranial aneurysms often involves the eye lens in the primary beam of radiation. OBJECTIVE: To assess and compare eye-lens doses imparted during interventional and non-interventional imaging techniques for the examination of intracranial aneurysms. METHODS: We performed a phantom study on an anthropomorphic phantom (ATOM dosimetry phantom 702-D; CIRS, Norfolk, Virginia, USA) and assessed eye-lens doses with thermoluminescent dosimeters (TLDs) type 100 (LiF:Mg, Ti) during (1) interventional (depiction of all cerebral arteries with triple 3D-rotational angiography and twice 2-plane DSA anteroposterior and lateral projections) and (2) non-interventional (CT angiography (CTA)) diagnosis of intracranial aneurysms. Eye-lens doses were calculated following recommendations of the ICRP 103. Image quality was analysed in retrospective by two experienced radiologists on the basis of non-interventional and interventional pan-angiography examinations of patients with incidental aneurysms (n=50) on a five-point Likert scale. RESULTS: The following eye-lens doses were assessed: (1) interventional setting (triple 3D-rotational angiography and twice 2-plane DSA anteroposterior and lateral projections) 12 mGy; (2) non-interventional setting (CTA) 4.1 mGy. Image quality for depiction of intracranial aneurysms (>3 mm) was evaluated as good by both readers for both imaging techniques. CONCLUSIONS: Eye-lens doses are markedly higher during the interventional than during the non-interventional diagnosis of intracranial aneurysms. For the eye-lens dose, CTA offers considerable radiation dose savings in the diagnosis of intracranial aneurysms.


Assuntos
Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Cristalino/diagnóstico por imagem , Neuroimagem/métodos , Doses de Radiação , Adulto , Idoso , Angiografia Digital/métodos , Angiografia Digital/normas , Angiografia Cerebral/normas , Angiografia por Tomografia Computadorizada/normas , Feminino , Humanos , Imageamento Tridimensional/métodos , Imageamento Tridimensional/normas , Pessoa de Meia-Idade , Neuroimagem/normas , Imagens de Fantasmas/normas , Estudos Retrospectivos
12.
AJNR Am J Neuroradiol ; 27(8): 1741-5, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16971627

RESUMO

BACKGROUND AND PURPOSE: To assess patient radiation exposure in comprehensive stroke imaging using multidetector row CT (MDCT) combining standard CT of the head, cerebral perfusion (CTP), and CT angiography (CTA) studies. METHODS: Examination protocols for CT and CTA of cerebral and cervical vessels, as well as CTP were simulated using a Somatom Sensation Cardiac 64. Effective doses were derived from measurements with the use of lithium-fluoride thermoluminescent dosimeters (LiF-TLD) at several organ sites using an Alderson-Rando phantom. RESULTS: LiF-TLD measurements resulted in effective doses of 1.7 mSv for CT, 1.9 mSv for CTA of intracranial vessels, and 2.8 mSv for CTA of cervical vessels, respectively. Depending on examination parameters, effective doses varied between 1.1 and 5.0 mSv for cerebral CTP. For CTP, local doses in the area of the primary beam ranged between 114 and 444 mGy. CONCLUSIONS: Comprehensive stroke imaging may result in up to 9.5 mSv with possible local doses of 490 mGy. Although critical doses for organ damage (eg, cataract formation or hair loss) are not reached, physicians need to be aware of possible radiation induced sequelae particularly in repetitive examinations.


Assuntos
Infarto Cerebral/diagnóstico por imagem , Dosimetria Termoluminescente , Tomografia Computadorizada Espiral , Doença Aguda , Carga Corporal (Radioterapia) , Angiografia Cerebral , Humanos , Imagens de Fantasmas , Doses de Radiação , Lesões por Radiação/prevenção & controle , Fatores de Risco
13.
AJNR Am J Neuroradiol ; 37(4): 636-41, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26564437

RESUMO

Giant intracranial aneurysms are rare vascular pathologies associated with high morbidity and mortality. The purpose of this in vivo study was to assess giant intracranial aneurysms and their wall microstructure by 7T MR imaging, previously only visualized in histopathologic examinations. Seven giant intracranial aneurysms were evaluated, and 2 aneurysms were available for histopathologic examination. Six of 7 (85.7%) showed intraluminal thrombus of various sizes. Aneurysm walls were depicted as hypointense in TOF-MRA and SWI sequences with excellent contrast ratios to adjacent brain parenchyma (range, 0.01-0.60 and 0.58-0.96, respectively). The triple-layered microstructure of the aneurysm walls was visualized in all aneurysms in TOF-MRA and SWI. This could be related to iron deposition in the wall, similar to the findings in 2 available histopathologic specimens. In vivo 7T TOF-MRA and SWI can delineate the aneurysm wall and the triple-layered wall microstructure in giant intracranial aneurysms.


Assuntos
Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/patologia , Angiografia por Ressonância Magnética/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino
14.
Clin Neuroradiol ; 25(1): 13-7, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24287969

RESUMO

PURPOSE: This study aimed to determine the yield of repetitive catheter angiography (digital subtraction angiography (DSA)) for the detection of causative vascular lesions in patients with nontraumatic subarachnoidal hemorrhage (SAH) and negative initial DSA. We hypothesize that a second DSA might be helpful to detect an initially occult bleeding source. METHODS: We retrospectively evaluated 649 patients with acute SAH and invasive catheter angiographies between 2004 and 2012. In 90 SAH patients initial imaging was negative concerning a causative bleeding source. A total of 113 repetitive DSA were performed. Two neuroradiologists reanalyzed the initial imaging and the result of the reangiography independently. RESULTS: In 4/90 patients (4.5 %) bleeding source was first detected in the second or third DSA. In all other patients, no causative vascular lesion was found. Reasons for the initially false negative diagnostics were one dissecting aneurysm and thrombosis of three aneurysms within the acute phase of SAH. CONCLUSIONS: Repetitive DSA revealed the cause of SAH in 4.5 % of the cases. These findings have a therapeutic and prognostic impact. We think that at least a second DSA should be part of diagnostic work-up in patients with SAH and missing bleeding source, even considering the risk of an additional invasive angiography itself.


Assuntos
Angiografia Digital/métodos , Cateterismo Periférico/métodos , Intensificação de Imagem Radiográfica/métodos , Hemorragia Subaracnóidea/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
Rofo ; 186(7): 675-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24477505

RESUMO

PURPOSE: In about 15 % of patients with SAH no causative vascular lesions can be found in acute imaging with CTA and DSA. Usually, repeat DSA is mandatory and bears the usual risk of invasive angiography. The present study attempts to assess the diagnostic impact of 3 D rotational angiography in order to avoid repeat DSA. MATERIALS AND METHODS: From January 2004 to December 2012, 649 patients with an acute non-traumatic SAH were examined. 91 patients with negative initial imaging diagnostics concerning the bleeding source were included in this study. These patients underwent a second angiography scan: 61 in 4-plane technique, and 30 with 2-plane technique and additional 3 D DSA. Two cohorts were compared: patients with repeat angiography in conventional 4-plane technique from 2004 to July 2008 and 2-plane technique with additional 3 D rotational DSA from 2008 to 2012. Statistical significance was verified by means of Fisher's exact test. RESULTS: In the second DSA scan, 4 aneurysms in 4 patients (4/91; 4.4 %) were found and treated subsequently. Within the first 4.5 years of this study, 401 patients with SAH were treated and 61 of them underwent repeat angiography (15.2 %) compared to 30 of 248 patients (12.1 %) in the last 4.5 years of this study. In the first group we found 3 aneurysms during repeat angiography, and in the second group we found 1. No significance was reached (p = 0.29) but there was a tendency towards higher diagnostic security using 3D-DSA. CONCLUSION: Using 3 D rotational DSA in initial imaging workup might help to reduce false-negative results concerning the bleeding source of acute SAH. At least because of this fact, 3 D rotational DSA should be part of the diagnostic workup after acute SAH.


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Imageamento Tridimensional/métodos , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Lesões Encefálicas/diagnóstico por imagem , Lesões Encefálicas/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento , Procedimentos Desnecessários
16.
J Neurointerv Surg ; 6(6): 461-5, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23929549

RESUMO

PURPOSE: New ischemic brain lesions are common findings after cerebral diagnostic angiography and endovascular therapy. Diffusion-weighted MRI (DWI) can be used for detection of these lesions. The aim of the present study was to investigate the incidence of DWI lesions after stent-assisted coiling and the evaluation of possible risk factors. METHODS: The study included a total of 75 consecutive patients treated with stent-assisted coiling. Post-procedural DWI of the brain was performed to detect ischemic lesions. Demographic data, aneurysm characteristics and angiographic parameters were correlated with properties of DWI lesions. RESULTS: In post-procedural DWI, 48 of the 75 patients (64%) had 163 DWI lesions in a pattern consistent with embolic events. The number of patients with DWI lesions was significantly increased in older patients (≥55 years) and longer intervention times (≥120 min). The ischemic brain volume was significantly increased in older patients (≥55 years) as well as in patients who were implanted with a shorter stent (<20 mm). CONCLUSIONS: Thromboembolic events are common after stent-assisted coiling with an incidence comparable to DWI studies after coiling alone. Despite several devices and low operator experience, stent-assisted coiling for intracranial aneurysms has a very low risk of permanent neurologic disability. Further studies are necessary to improve the safety of stent-assisted coiling for patients in conditions with increased risk potential (age, procedure time, stent length).


Assuntos
Aneurisma Intracraniano/cirurgia , Embolia Intracraniana/etiologia , Stents/efeitos adversos , Adulto , Fatores Etários , Idoso , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Incidência , Embolia Intracraniana/epidemiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco
17.
Rofo ; 185(4): 328-32, 2013 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-23420312

RESUMO

PURPOSE: Flow diverters may occlude aneurysms by endoluminal reconstruction of the parent artery and by reducing the blood flow into the aneurysm. The purpose of this study was to assess the rate of intervention-associated complications and a 3-year-follow-up. MATERIALS AND METHODS: We retrospectively analyzed 18 patients treated with Silk® FD. Only patients with unruptured aneurysms were included. Treatment indications were fusiform, giant or recurrent aneurysms. We considered all aneurysms to have a high likelihood of failure and/or recurrence when treated with conventional endovascular techniques. RESULTS: Silk FD could directly be placed in a proper position across the whole length of the aneurysm in 16/18 patients. In one case an additional PTA was necessary. In another case the first FD could not be properly deployed. 17 of 18 aneurysms (95 %) were occluded immediately, in the mid-term follow-up after 6 months or 3 years after treatment. The overall complication rate including technical (11.1 %), acute or delayed thromboembolic complication without (11.1 %) or with (16.6 %) severe complications was documented. CONCLUSION: FD treatment is effective with a high occlusion rate of aneurysms also in long-term follow-up. In these complex aneurysms the complication rate is higher than in conventional stent-assisted coiling.


Assuntos
Aneurisma Intracraniano/terapia , Stents , Adulto , Idoso , Aspirina/administração & dosagem , Angiografia Cerebral , Clopidogrel , Embolização Terapêutica , Desenho de Equipamento , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/administração & dosagem , Pré-Medicação , Recidiva , Retratamento , Instrumentos Cirúrgicos , Ticlopidina/administração & dosagem , Ticlopidina/análogos & derivados , Tomografia Computadorizada por Raios X
18.
Rofo ; 182(10): 868-72, 2010 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-20740393

RESUMO

PURPOSE: The assessment of the radiological response of recurrent glioma is based on the Macdonald or RECIST criteria 8 to 10 weeks from the start of treatment. Magnetic resonance imaging using an apparent diffusion coefficient map may provide an earlier measure for predicting the response to therapy of recurrent glioma. MATERIALS AND METHODS: Twelve patients with recurrent high-grade glioma were enrolled in a feasibility study of pretreatment MRI on day 1, intra-treatment MRI in week 3, and post-treatment MRI in week 12. Prognostically relevant ADC values (ADCprog) of each recurrent glioma at 3 weeks were calculated as a function of their pre- and intra-therapy ADC values (ADCpre - ADCintra = ADCprog). Because we hypothesized that smaller ADC values correlate with less Brownian motion of water molecules in the extracellular space and that a higher cell density may restrain this water diffusion, we set smaller ADC values at a second time point as "progressive disease" (PD) and higher ADC values as "partial response" (PR). A change in ADCprog of less than 10 × 10⁻6mm² /sec was set as "stable disease" (SD). The ADCprog values were always calculated before the final scan after 3 months was performed. The readers were blinded to the future development of the tumor. RESULTS: In 10 of the 12 patients we could correctly predict the tumor response to chemotherapy. One patient died before the three-month control, and one recurrent glioma did not develop as predicted. ADC mapping is found to predict patient response at 3 weeks from the start of treatment, revealing that early changes in tumor diffusion values could be used as a prognostic indicator also for chemotherapeutically treated recurrences of high-grade glioma.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Encefálicas/diagnóstico , Neoplasias Encefálicas/tratamento farmacológico , Imagem de Difusão por Ressonância Magnética/métodos , Glioblastoma/diagnóstico , Glioblastoma/tratamento farmacológico , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Recidiva Local de Neoplasia/diagnóstico , Recidiva Local de Neoplasia/tratamento farmacológico , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais/efeitos adversos , Anticorpos Monoclonais Humanizados , Bevacizumab , Encéfalo/patologia , Camptotecina/administração & dosagem , Camptotecina/efeitos adversos , Camptotecina/análogos & derivados , Meios de Contraste/administração & dosagem , Feminino , Seguimentos , Gadolínio , Humanos , Irinotecano , Masculino , Sensibilidade e Especificidade , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa