Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Diabetes Care ; 6(2): 122-8, 1983.
Artigo em Inglês | MEDLINE | ID: mdl-6343016

RESUMO

The metabolic response to exercise in insulin-dependent diabetic (IDD) man was assessed during continuous insulin infusion using the subcutaneous (CSII), intravenous (CIVII), and intraperitoneal (CIPII) routes. During the basal period, plasma glucose levels were higher with CIPII (153 +/- 17 mg/dl) than with CSII (117 +/- 13 mg/dl) or CIVII (118 +/- 17 mg/dl). Basal free insulin concentrations were similar for CSII (12.3 +/- 10 microU/ml) and CIVII (12.4 +/- 1.4 MicroU/ml) but lower in CIPII (8.5 +/- 1.0 microU/ml, P less than 0.05). Exercise on a stationary bicycle at 75 W for 60 min produced a decline of plasma glucose in each protocol that was significantly only during CIVII (55 +/- 11 mg/dl, P less than 0.01). Insulin levels remained unchanged throughout the study period in all protocols. In normals, insulin values decreased during exercise and remained below basal levels through the recovery period (P less than 0.05), while plasma glucose remained unchanged. Plasma glucagon and epinephrine levels were similar in all protocols and remained unchanged with exercise, while plasma norepinephrine tended to be higher than normal in all diabetic subjects. Significant differences between normal and diabetic subjects (P less than 0.05) were observed for blood ketone bodies, while blood lactate, glycerol, and plasma FFA were similar. Normalization of intermediary metabolites occurred only with CIVII. Continuous insulin infusion provides near-normal glycemic and metabolic control before, during and following exercise in IDD man. However, to produce normal blood concentrations of intermediary metabolites during exercise, the insulin infusion rate may be excessive in terms of its hypoglycemic effect. CSII appears to be a safe, accessible, and adequate method for treating diabetic man during exercise.


Assuntos
Diabetes Mellitus/tratamento farmacológico , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Esforço Físico , Adulto , Glicemia/análise , Humanos , Infusões Parenterais , Insulina/sangue , Insulina/metabolismo , Cetonas/sangue , Masculino , Norepinefrina/sangue
2.
J Clin Endocrinol Metab ; 56(3): 479-85, 1983 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-6822648

RESUMO

The present study was designed to examine the effects of excess T3 on total body glucose production and forearm exchange of glucose, amino acids, and other metabolites. Five healthy male volunteers were studied after an overnight fast, before and 7 days after the administration of 150 micrograms/day T3. Glucose production (milligrams per kg/min) was measured using a primed continuous infusion of [3-3H]glucose and gluconeogenic index (micromoles per kg/min) was measured by following the conversion of infused [14C]alanine to [14C]glucose. Blood flow across the forearm was measured using capacitance plethysmography and forearm release of substrates was determined by the Fick principle. After T3 administration, there was a 3.7-fold rise in T3 from 150 +/- 15 to 530 +/- 12 ng/dl (P less than 0.001), with no change in insulin (12 +/- 1 microU/ml pre-T3 vs. 13 +/- 2 microU/ml post-T3) and glucagon (79 +/- 5 pre-T3 vs. 84 +/- 7 pg/ml post-T3). T3 administration resulted in an increase in plasma glucose (from 83 +/- 5 to 98 +/- 5 mg/dl; P less than 0.05), net glucose uptake by the forearm (from 250 +/- 90 to 712 +/- 60 nmol/100 ml forearm tissue X min; P less than 0.005) and glucose production (1.7 +/- 0.09 to 2.2 +/- 0.08 mg/kg X min; P less than 0.005), without a change in glucose clearance (2.1 +/- 0.02 vs. 2.0 +/- 0.02 ml/kg X min); the rate of conversion of [14C]alanine to [14C]glucose increased by 30% (0.56 +/- 0.03 to 0.74 +/- 0.03 mumol/ kg X min P less than 0.005). These values were associated with a 25% increase in blood lactate to 712 +/- 69 mumol/liter (P less than 0.05) and a 131% increase in lactate release across the forearm to 434 +/- 90 (P less than 0.005). Forearm release of alanine (96 +/- 29 nmol/100 ml forearm tissue X min) and glutamine (151 +/- 41 nmol/100 ml forearm tissue X min) increased by 90% (P less than 0.005 and P = 0.04, respectively), with no change in their concentrations. Forearm release of branched chain amino acids did not change, while those of their ketoacids, alpha-ketoisocaproate (KIC) and alpha-ketoisovalerate (KIV), doubled (to 64 +/- 9 mumol/liter for KIC and 39 +/- 6 mumol/liter for KIV; P less than 0.05). These were associated with a 45% increase in the branched chain amino acid levels and a 46% rise in both KIC and KIV levels to 41 +/- 9 and 28 +/- 7 mumol/liter, respectively (P less than 0.05). There was a concurrent significant (P less than 0.05) change in the arterial levels of phenylalanine (-32%), tyrosine (-29%), threonine (-20%), glycine (-20%), and serine (-15%), without any change in their efflux across the forearm. The data indicate that a pharmacologically induced rise in T3, to levels comparable to those seen in hyperthyroidism, results in enhanced glucose production, with an increase in glucose uptake by the forearm. The former can be partially accounted for by an increase in hepatic gluconeogenesis, glycogenolysis, or possibly increased renal glucose production...


Assuntos
Glucose/metabolismo , Músculos/metabolismo , Hormônios Tireóideos/farmacologia , Adulto , Aminoácidos/metabolismo , Glicemia/análise , Antebraço/metabolismo , Gluconeogênese/efeitos dos fármacos , Humanos , Lactatos/metabolismo , Ácido Láctico , Masculino
3.
J Med Chem ; 39(1): 10-8, 1996 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-8568796

RESUMO

Ether, ester, and carbonate derivatives of the antirheumatic oxindole 1 were prepared and screened as potential prodrugs of 1. This effort led to the discovery of the (alpha-L-alanyloxy)-methyl ether and hemifumarate derivatives of 1 which deliver the drug efficiently into the circulation of test animals, are stable in the solid state, and possess good stability in solution at low pH as required to ensure gastric stability. Success in achieving acceptable bioavailabilities of 1 across species (rats, dogs, and monkeys) followed the inclusion of ionizable functionality within the promoiety to compensate for masking the polar enolic OH group of the free drug. However, the introduction of ionizable functionality was often associated with decreased stability, as demonstrated by the hemisuccinate, hemiadipate, hemisuberate, and alpha-amino ester derivatives of 1 which could not be isolated. A clear exception was the hemifumarate derivative of 1 which was not only isolable but actually more stable at neutral pH than the nonionizable ester analogues. The solution and solid state stability of the hemifumarate, together with its activity as a prodrug of 1, suggests that hemifumarate be considered as an alternative to hemisuccinate as a prodrug derivative for alcohols, particularly in situations where solution state stability is an issue.


Assuntos
Anti-Inflamatórios não Esteroides/síntese química , Indóis/síntese química , Maleatos/síntese química , Pró-Fármacos/síntese química , Animais , Anti-Inflamatórios não Esteroides/química , Anti-Inflamatórios não Esteroides/farmacocinética , Anti-Inflamatórios não Esteroides/farmacologia , Disponibilidade Biológica , Cães , Éteres/síntese química , Éteres/farmacologia , Fumaratos/síntese química , Fumaratos/farmacologia , Indóis/química , Indóis/farmacocinética , Indóis/farmacologia , Macaca fascicularis , Espectroscopia de Ressonância Magnética , Maleatos/química , Maleatos/farmacocinética , Maleatos/farmacologia , Estrutura Molecular , Pró-Fármacos/química , Pró-Fármacos/farmacocinética , Pró-Fármacos/farmacologia , Ratos , Ratos Sprague-Dawley
4.
Biochem Pharmacol ; 50(9): 1421-32, 1995 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-7503793

RESUMO

Tenidap [5-chloro-2,3-dihydro-3-(hydroxy-2-thienylmethylene)-2-oxo-1H- indole-1-carboxamide], a novel antirheumatic agent, produces a rapid and sustained intracellular acidification when applied to cells in culture. To investigate the mechanism by which this change in ionic homeostasis is achieved, the acidification activities of structural analogs of tenidap were determined, and the movements of [14C]tenidap into and out of cells were explored. The acidification activity of tenidap was enhanced by lowering extracellular pH, suggesting that the free acid species was required for this process. Consistent with this requirement, a non-acidic analog of tenidap did not produce a change in intracellular pH (pHi). In contrast, multihalogenated derivatives of tenidap produced greater changes in pHi than did tenidap, and one analog produced a transient acidification from which the cell recovered; this recovery, however, was blocked by an inhibitor of the Na+/H+ antiporter. Fibroblasts incubated with [14C]tenidap achieved within 5 min a level of cell-associated drug that remained constant during longer incubations. Simultaneous addition of the electrogenic ionophore valinomycin or the P-glycoprotein inhibitor 4-(3,4-dihydro-6,7-dimethoxy-2(1H)-isoquinolinyl)-N-[2-(3,4-dimethoxyphe nyl) ethyl]-6,7-dimethoxy-2-quinazolinamine (CP-100,356) caused a time- and concentration-dependent increase in the level of cell-associated [14C]tenidap; other agents tested did not promote this enhanced cellular accumulation. [14C]Tenidap accumulated by fibroblasts in the presence of CP-100,356 subsequently was released when these cells were placed in a tenidap- and CP-100,356-free medium. Importantly, several agents that are known to inhibit anion transport processes, including alpha-cyano-beta-(1-phenylindol-3-yl) acrylate, 5-nitro-2(3-phenylpropylamino)-benzoic acid, and meclofenamic acid, inhibited efflux of [14C]tenidap. In contrast, ethacrynic acid and 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid did not impair the efflux process. Likewise, tenidap analogs that produced a sustained intracellular acidification blocked the efflux of [14C]tenidap, but non-acidifying species did not. These data suggest that movements of tenidap into and/or out of cells is a facilitated process subject to pharmacological intervention. Together, the structural selectivity of the acidification response and the evidence of facilitated transport suggest that the pHi modulating activity of tenidap is dependent on its unique physicochemical properties. Due to the dependence of these physicochemical properties on environmental and cellular conditions, in vivo expression of the acidification activity is likely to occur only within restricted environments that favor this tenidap-induced process.


Assuntos
Anti-Inflamatórios não Esteroides/farmacologia , Antiporters/efeitos dos fármacos , Antiporters/metabolismo , Indóis/farmacologia , Animais , Ânions , Anti-Inflamatórios não Esteroides/farmacocinética , Antiporters/antagonistas & inibidores , Transporte Biológico Ativo/efeitos dos fármacos , Células Cultivadas , Fenômenos Químicos , Físico-Química , Antiportadores de Cloreto-Bicarbonato , Interações Medicamentosas , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Humanos , Concentração de Íons de Hidrogênio , Indóis/farmacocinética , Líquido Intracelular/metabolismo , Canais Iônicos/efeitos dos fármacos , Canais Iônicos/metabolismo , Ionóforos/farmacologia , Células L , Camundongos , Neutrófilos/efeitos dos fármacos , Neutrófilos/metabolismo , Oxindóis , Trocadores de Sódio-Hidrogênio/antagonistas & inibidores , Trocadores de Sódio-Hidrogênio/efeitos dos fármacos , Trocadores de Sódio-Hidrogênio/metabolismo , Relação Estrutura-Atividade , Valinomicina/farmacologia
5.
J Bone Joint Surg Am ; 64(4): 525-35, 1982 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-7068695

RESUMO

To determine the effect of the ventilation system on infection rates after total hip and total knee arthroplasties performed in operating rooms with and without a horizontal unidirectional filtered air-flow system, using modern antiseptic conditions and antibiotic prophylaxis, all of the single-stage procedures (3175 of a total of 4769) were subjected to statistical analysis and fifty-seven matched pairs for controls were established. A reduced infection rate after total hip replacement (from 1.4 to 0.9 per cent) and an increased infection rate after total knee replacement (from 1.4 to 3.9 per cent) were found when patients operated on in the filtered laminar air-flow operating room were compared with those whose operations were done in two conventional rooms. This pattern was statistically significant and was believed to be due to the positions of the operating team and of the wound with respect to the air flow. Prospectively accumulated factors (such as the experience of the surgeon, the duration of surgery, the diagnosis, and the patient's age) as well as retrospectively accumulated factors (such as predisposing conditions of the patient) did not explain the observed patterns of infection.


Assuntos
Prótese de Quadril , Prótese do Joelho , Salas Cirúrgicas , Infecção da Ferida Cirúrgica/etiologia , Ventilação , Adulto , Idoso , Movimentos do Ar , Antissepsia/métodos , Métodos Epidemiológicos , Feminino , Filtração , Humanos , Masculino , Pessoa de Meia-Idade , Cidade de Nova Iorque , Infecção da Ferida Cirúrgica/epidemiologia
6.
J Bone Joint Surg Br ; 79(1): 140-6, 1997 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9020463

RESUMO

A three-dimensional computer model of a total hip replacement was used to examine the relationship between the position of the components, the range of motion and the prosthetic joint contact area. Horizontal acetabular positions with small amounts of acetabular and femoral anteversion provide the largest contact areas, but result in limited joint movement. These data will allow surgeons to select implant positions that will provide the largest possible joint contact area for a given joint range of motion although these are conflicting goals. In some component positions a truncated spherical prosthetic head resulted in smaller contact areas than a completely spherical head.


Assuntos
Simulação por Computador , Prótese de Quadril , Articulação do Quadril/fisiologia , Humanos , Desenho de Prótese , Amplitude de Movimento Articular
12.
J Arthroplasty ; 11(3): 247-54, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8713902

RESUMO

Fifty-three primary uncemented custom-molded Identifit (Depuy, Warsaw, IN) hip arthroplasties were evaluated prospectively at a mean follow-up period of 30 months. The custom technique provided the capability to reproduce the unique femoral offset, version, and height in each hip and to achieve high percentages of femoral canal fill. Surgical time for unilateral cases was a mean 153 minutes. Clinical results, however, were disappointing. Nine hips (17%) required stem revision for persistent thigh pain and limping. Of the remaining 44 hips, the mean Harris hip score was 83, and 20% experienced moderate to severe thigh pain and 50% had a limp. Radiographically, 65% of the stems had subsided and 27% had migrated into valgus. Survivorship analysis predicted an 80% stem survival rate at 43 months. A precise fit and fill of the femoral canal is not in itself sufficient for femoral implant stability in total hip arthroplasty surgery.


Assuntos
Prótese de Quadril/métodos , Adulto , Idoso , Artrite Reumatoide/cirurgia , Cimentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Estudos Prospectivos , Desenho de Prótese
13.
J Arthroplasty ; 10(1): 83-6, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7730835

RESUMO

The use of Cell Saver blood during revision hip arthroplasty has many benefits, both medical and economic. After a review of the current literature, to our knowledge, no case of metallic debris has been reported in the blood after complete treatment with the Haemonetics Cell Saver (Braintree, MA) and appropriate filter system. A case of total hip revision of a loose, cemented acetabular component with a commercially pure titanium metal backing and a titanium alloy plasma-spray textured surface was undertaken. The titanium alloy femoral component was not visibly loose and was not revised. The joint lining tissues were black. Throughout the procedure, the operative site was suctioned with a double-lumen heparinized catheter that delivered blood and other materials to a Haemonetics Cell Saver 3 Plus. The reservoir and filter unit used were the compatible Bentley BCR-3500 (Baxter, Irvine, CA), a system capable of filtering particulates down to 20 microns. Prior to infusion of the salvaged blood, many large black clumps of material were observed mixed in the blood. Some measured 10 x 5 x 5 mm and could easily be seen macroscopically. Light microscopy demonstrated red blood cells with intermixed neutrophils, and black foreign material scattered as separate particles and within the cytoplasm of the scattered histiocytes. Energy dispersive analysis of the black material confirmed the composition as primarily titanium with minute quantities of copper, iron, phosphorous, and sulfur. A scanning electron photomicrograph of one of the specimens demonstrated a large conglomerate, approximately 2,000 microns in diameter, composed primarily of titanium and organic material.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Transfusão de Sangue Autóloga , Prótese de Quadril , Titânio , Idoso , Perda Sanguínea Cirúrgica , Transfusão de Sangue Autóloga/instrumentação , Transfusão de Sangue Autóloga/métodos , Transfusão de Sangue Autóloga/normas , Feminino , Filtração , Humanos , Cuidados Intraoperatórios , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Falha de Prótese , Reoperação , Sucção , Titânio/sangue
14.
J Arthroplasty ; 10(4): 476-9, 1995 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-8523007

RESUMO

Removal of a prosthetic modular femoral head is sometimes desirable during revision hip arthroplasty. A femoral head extractor was designed to heat and expand the prosthetic femoral head, apply a gentle distraction load, and remove the femoral head without injury to the femoral neck, taper, or bone-prosthesis interface. The device was used clinically in six hip revision cases. In five hips with cobalt-chrome heads and titanium alloy tapers, femoral heads were removed successfully; femoral fixation was maintained and femoral components were not visibly damaged. In the sixth case, the female portion of the taper junction was contained in a long femoral head sleeve. Heating the ball did not adequately expand the sleeve to allow easy ball removal.


Assuntos
Prótese de Quadril/instrumentação , Cabeça do Fêmur , Temperatura Alta , Humanos , Equipamentos Ortopédicos , Reoperação
15.
J Arthroplasty ; 9(2): 177-92, 1994 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8014649

RESUMO

Fifty-one Cementless Spotorno (CLS, Protek A. G. Berne) stems were implanted in 43 patients with either a Harris Galante (Zimmer, Warsaw, IN) socket or bipolar head. Patients were evaluated at a mean of 31 months. Eighty percent of the hips were in patients who were less than 50 years of age or weighed more than 80 kg. The CLS stem achieved initial stability by wedging a proximally fluted, straight stem into a retained bed of femoral trabecular and cortical bone. Distal canal fill was avoided. The postoperative mean Harris hip score was 95. Eighty percent of the hips were rated excellent, 16% good, 2% fair, and 2% poor. No stem required revision. Six percent had slight, occasional thigh pain. No patient had mild, moderate, or severe thigh pain. Six percent had a limp related to the operated hip. Fifty-three percent of the hips developed a radiographic appearance of bone apposition at the stem tip. Fifty-five percent of the hips had some reduction in proximal bone density. These changes suggested that as bone remodeling occurred, the initial proximal load transfer situation expected from the CLS stem design changed to include some distal load transfer resulting in proximal stress shielding. Ninety-four percent of the hips had either no change in femoral bone density or only patchy loss of density isolated to zone 7. A high dislocation rate was attributed to an unfavorable head-to-neck diameter ratio, a valgus neck shaft angle, and a patient population capable of excellent hip motion.


Assuntos
Necrose da Cabeça do Fêmur/cirurgia , Prótese de Quadril , Osteoartrite/cirurgia , Ligas , Peso Corporal , Densidade Óssea , Feminino , Necrose da Cabeça do Fêmur/epidemiologia , Seguimentos , Quadril/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/epidemiologia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Radiografia , Reoperação , Fatores de Tempo , Titânio
16.
J Arthroplasty ; 11(3): 286-92, 1996 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8713908

RESUMO

An uncemented titanium alloy stem with a corundum blast finish and an uncemented titanium fibermetal mesh socket were implanted in a series of 57 hips. These prostheses were selected for use in the youngest, most active, and/or heaviest candidates for total hip arthroplasty. Fifty hips were available for study at a minimum 60 months. At a mean 6 years, 92% of the hips were rated good or excellent. The mean Harris hip score was 92. One patient experienced mild thigh pain. The corundum blast finish was associated with reliable implant stability. Survival analysis predicted a 96% rate of implant survival at 92 months. Loss of bone density was rated mild, minimal, or none in 88% of the hips. Three hips developed severe bone loss due to systemic disease. Polyethylene wear was measurable in 86% of the hips. Twenty hips developed focal proximal femoral bone erosions. One hip had endosteal cavitation distal to zone 7. The presence of proximal femoral erosions or endosteal cavitation correlated positively with the presence of measurable polyethylene wear. The limited and proximal distribution of femoral bone erosion despite evidence of extensive polyethylene wear suggested that bone apposition to the corundum blast finish resulted in a barrier to migration of wear debris.


Assuntos
Prótese de Quadril/métodos , Adulto , Idoso , Ligas , Óxido de Alumínio , Densidade Óssea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Desenho de Prótese , Estudos Retrospectivos , Titânio
17.
J Biomed Mater Res ; 15(2): 203-8, 1981 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7348714

RESUMO

Samples of low viscosity poly(methyl methacrylate) (PMMA), graphite reinforced PMMA, and graphite reinforced low viscosity PMMA were evaluated for their compression strength and fracture toughness. These results were compared with two currently used plain PMMA bone cements. There were no statistically significant differences in compression strength between the five cements. Graphite reinforcement of plain cement produced a 32% increase in fracture toughness over plain cement. Graphite reinforcement of low viscosity cement also produced a significant increase in toughness (31%) over low viscosity cement with fiber reinforcement. However, low viscosity cement demonstrated significantly less fracture toughness than plain PMMA.


Assuntos
Cimentos Ósseos , Metilmetacrilatos , Análise de Variância , Pressão , Viscosidade
18.
Clin Orthop Relat Res ; (147): 143-7, 1980.
Artigo em Inglês | MEDLINE | ID: mdl-7371281

RESUMO

One-hundred fifty-six consecutive total hip replacements through a lateral transtrochanteric approach were evaluated and compared to a closely matched group of 160 consecutive similar procedures via a posterior approach. The lateral approach did not have any dislocations and created a greater abductor lever arm. However, a 4.5% complication rate was related to the greater trochanter and degraded the result. The posterior approach provided a shorter operative time, required less blood replacement, and resulted in a shorter hospital stay. However a 4.4% incidence of dislocation decreased the rate of recovery and the final result. Since this early experience, an improved technique of reattaching the short external rotators had mitigated the problem of dislocations. Wound and systemic complications, postoperative results, radiographic findings and prosthetic positioning were not significantly different in comparable patients treated by the 2 surgical approaches.


Assuntos
Artroplastia/métodos , Prótese de Quadril , Adulto , Idoso , Feminino , Seguimentos , Articulação do Quadril , Humanos , Artropatias/cirurgia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Fatores de Tempo
19.
J Rheumatol ; 5(2): 190-4, 1978.
Artigo em Inglês | MEDLINE | ID: mdl-671436

RESUMO

A boy with polyarticular osteochondritis dissecans presented with clinical features of juvenile rheumatoid arthritis. Examination of the synovial fluid of an involved joint demonstrated inflammatory characteristics. Osteochondritis dissecans was present in the patient's mother and brother. Human leukocyte antigens HLA A-2, BW-15 and CW-4 were identified in the affected individuals.


Assuntos
Artrite Juvenil/diagnóstico , Osteocondrite/genética , Criança , Diagnóstico Diferencial , Antígenos HLA , Humanos , Masculino , Osteocondrite/diagnóstico , Osteocondrite/imunologia
20.
J Arthroplasty ; 4(1): 55-64, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2926409

RESUMO

Forty-seven DF-80 total hip arthroplasties performed in 40 patients were evaluated to determine the incidence and causes of early femoral component loosening. With an average 37.1-month follow-up period, 48.9% of the femoral components developed bone cement-bone radiolucent lines worrisome for stem loosening. Twenty-three percent of the stems had subsided and 4.3% had been revised. Radiolucent lines were apparent very early (average, 8.8 months). Statistical analysis revealed positive correlations between the use of the larger (45-mm) offset stem and both the appearance of radiolucent lines and stem loosening. Being male and tall also were associated with stem loosening. The causes for early DF-80 femoral component loosening could not be defined with certainty. The results of this study and a review of the literature suggest that failure may be a result of early biologic weakening of the proximal cement-bone interface combined with a stem design that maintains proximal bone loading. Metal debris did not appear to be a factor in loosening of this titanium alloy stem.


Assuntos
Prótese de Quadril , Idoso , Ligas , Cimentos Ósseos , Feminino , Fêmur , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Fatores de Tempo , Titânio
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa