Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 113: 92-104, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23664859

RESUMO

Corneal collagen crosslinking with riboflavin photosensitization and ultraviolet irradiation is a novel approach to limiting the progression of keratoconus in patients by increasing the elastic modulus of the degenerate cornea. Beneficial reductions in corneal steepness and aberrations after crosslinking also frequently occur. In a previous study, we described a computational modeling approach to simulating topographic progression in keratoconus and regression of disease with corneal collagen crosslinking. In the current study, this model has been expanded and applied to the inverse problem of estimating longitudinal time-dependent changes in the corneal elastic modulus after crosslinking using in vivo measurements from 16 human eyes. Topography measured before crosslinking was used to construct a patient-specific finite element model with assumed hyperelastic properties. Then the properties of the cornea were altered using an inverse optimization method to minimize the difference between the model-predicted and in vivo corneal shape after crosslinking. Effects of assumptions regarding sclera-to-cornea elastic modulus ratio and spatial attenuation of treatment effect due to ultraviolet beam characteristics on the predicted change in elastic modulus were also investigated. Corneal property changes computed by inverse finite element analysis provided excellent geometric agreement with clinical topography measurements in patient eyes post-crosslinking. Over all post-treatment time points, the estimated increase in corneal elastic modulus was 110.8 ± 48.1%, and slightly less stiffening was required to produce the same amount of corneal topographic regression of disease when the sclera-to-cornea modulus ratio was increased. Including the effect of beam attenuation resulted in greater estimates of stiffening in the anterior cornea. Corneal shape responses to crosslinking varied considerably and emphasize the importance of a patient-specific approach.


Assuntos
Colágeno/metabolismo , Substância Própria/fisiologia , Reagentes de Ligações Cruzadas/uso terapêutico , Elasticidade/fisiologia , Ceratocone/tratamento farmacológico , Simulação por Computador , Substância Própria/efeitos da radiação , Topografia da Córnea , Módulo de Elasticidade , Feminino , Análise de Elementos Finitos , Humanos , Ceratocone/metabolismo , Masculino , Fármacos Fotossensibilizantes/uso terapêutico , Estudos Prospectivos , Riboflavina/uso terapêutico , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa