Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Eur J Orthop Surg Traumatol ; 33(8): 3403-3409, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37140672

RESUMO

BACKGROUND: The addition of junctions in modular stems implies a greater susceptibility to corrosion. PURPOSE: The aim of this study is to compare serum chromium and cobalt levels after using a bimodular stem and its monoblock counterpart in primary total hip arthroplasty. Postoperative clinical scores were also compared. PATIENTS AND METHODS: A prospective cohort study between 2012 and 2015 was designed. One arm of the cohort included patients with the cementless modular neck stem H-Max M® and the other with the cementless monoblock stem counterpart H-Max S®. RESULTS: No statistically significant difference was found in chromium value between groups (p = 0.621) at two years postoperative. Cobalt value was higher in the modular group (p = < 0.001). No statistically significant difference was found in clinical postoperative scores except for the Harris Hip Score, with better results at six months in modular group (p = 0.007). CONCLUSIONS: Higher serum cobalt level in the modular group has limited the use of modular stems in our daily practice. Advantages of modular stem were not found. LEVEL OF EVIDENCE: II.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/métodos , Prótese de Quadril/efeitos adversos , Cromo , Cobalto , Estudos Prospectivos , Falha de Prótese , Desenho de Prótese
2.
Rev Esp Cir Ortop Traumatol ; 68(1): T26-T34, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37992863

RESUMO

INTRODUCTION AND OBJECTIVES: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyse their temporal evolution during five years. MATERIAL AND METHODS: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the H MAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), p=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilisation of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), p=.001. CONCLUSION: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.

3.
Rev Esp Cir Ortop Traumatol ; 68(1): 26-34, 2024.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37270057

RESUMO

INTRODUCTION AND OBJECTIVES: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. MATERIAL AND METHODS: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. RESULTS: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. CONCLUSION: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.

4.
Rev Esp Cir Ortop Traumatol ; 66(6): 445-453, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35490100

RESUMO

INTRODUCTION AND OBJECTIVE: Dual modularity stems seek to more precisely restore anatomy by allowing intraoperative adjustments thanks to modular necks. Our aim is to compare the radiographic length correction with the H MAX-M® Stem versus its monoblock counterpart H MAX-S®. MATERIAL AND METHODS: A prospective cohort study was carried out through consecutive sampling on patients who underwent primary total hip arthroplasty with coxarthrosis diagnosis between 2011 and 2015. One arm of the cohort included patients who were operated with a modular stem and the other with a monobloc stem. Length was measured on the anteroposterior pelvic-bearing radiograph at six months. The mean of the measurements obtained for each arm of the cohort were compared with each other. RESULTS: No statistically significant differences were observed in the correction of asymmetry between both groups, determined as the difference in length between the operated hip and the contralateral hip (P=.106). Nor were differences observed in postoperative length values (P=.053). It should be noted that for both the modular stem and the monobloc stem, the majority group is the one with restored length (84.1% and 80.4%, respectively; P=.001). CONCLUSION: Despite the theoretical advantage of modularity and that having interchangeable parts could be of great interest, in our study, we have not been able to demonstrate a superiority of modular designs compared to monoblock for control of postoperative leg length discrepancy.

5.
Rev Esp Cir Ortop Traumatol ; 66(6): T27-T35, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35858669

RESUMO

INTRODUCTION AND OBJECTIVE: Dual modularity stems seek to more precisely restore anatomy by allowing intraoperative adjustments thanks to modular necks. Our aim is to compare the radiographic length correction with the H MAX-M® Stem versus its monoblock counterpart H MAX-S®. MATERIAL AND METHODS: A prospective cohort study was carried out through consecutive sampling on patients who underwent primary total hip arthroplasty with coxarthrosis diagnosis between 2011 and 2015. One arm of the cohort included patients who were operated with a modular stem and the other with a monobloc stem. Length was measured on the anteroposterior pelvic-bearing radiograph at 6 months. The mean of the measurements obtained for each arm of the cohort were compared with each other. RESULTS: No statistically significant differences were observed in the correction of asymmetry between both groups, determined as the difference in length between the operated hip and the contralateral hip (p=.106). Nor were differences observed in postoperative length values (p=.053). It should be noted that for both the modular stem and the monobloc stem, the majority group is the one with restored length (84.1% and 80.4%, respectively; p=.001). CONCLUSION: Despite the theoretical advantage of modularity and that having interchangeable parts could be of great interest, in our study, we have not been able to demonstrate a superiority of modular designs compared to monoblock for control of postoperative leg length discrepancy.

6.
Rev Esp Cir Ortop Traumatol ; 66(6): 421-428, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34362699

RESUMO

OBJECTIVE: To analyze the clinical and radiologic results, the survival and complications obtained in 70 year or older patients who underwent cementless total knee arthroplasty (TKA). MATERIAL AND METHOD: An observational study of patients operated between January 2014 and December 2016 was carried out according to the Natural Knee model (Zimmer®, USA). The main variables were the Oxford Knee Score, the visual analog scale, the presence of radiolucencies, complications, survival and reasons for revision. RESULTS: Of 104 TKA, 86 were available for revision. The median age was 76 years. The mean follow-up was 5.4 years (range 3.7-6.9). The Oxford Knee Score punctuation showed a median of 17 presurgical (range 0-40) and 37 post surgical (range 5-48), P<.001. The 87.2% of the patients obtained a clinically significant improvement. The median visual analog scale punctuation was 8 for presurgical (range 4-10) and 2 for post surgical (range 1-9), P<.001. The 88.3% of the patients obtained a clinically significant decrease. Three months after the surgery, the 55.81% of the TKAs presented radiolucencies around the tibial plateau. At the end of the follow-up, radiolucencies were present in 30.23% of the TKAs. Survival from all causes was 91.86% at 77.2 months and 96.5% due to aseptic loosening. CONCLUSION: Cementless knee prostheses are a valid option in patients aged 70 or older, presenting good clinical, radiological and survival results.

7.
Rev Esp Cir Ortop Traumatol ; 66(2): 77-85, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35404794

RESUMO

INTRODUCTION AND OBJECTIVE: Dual modularity stems were introduced with the theoretical advantage of restoring hip anatomy more precisely through femoral offset and limb length adjustment. Interchangeable necks allow for intraoperative angulation, anteversion and length changes. Our objective is to study whether a better femoral offset correction is achieved with the H MAX-M® prosthesis (Limacorporate, San Daniele, Italy) compared to its monoblock counterpart. MATERIAL AND METHODS: A prospective cohort study was conducted by means of consecutive sampling on adult patients undergoing total hip arthroplasty with the diagnosis of coxarthrosis between January 2011 and December 2015. This cohort has two arms, one arm included patients who underwent modular neck arthroplasty and the other included patients who underwent monoblock total hip arthroplasty. Radiographic offset measurement of the operated hip and the contralateral hip was performed, and the difference between both values was calculated. The mean of the measurements obtained for each arm of the cohort were compared with each other. RESULTS: No statistically significant differences were observed in the difference in offset between the operated hip and the contralateral hip (P=.323). No statistically significant differences were observed in the correction of the femoral offset, determined as the difference between the operated hip and the contralateral hip (P=.323). Nor were differences observed in the postoperative offset values (P=.097). It should be noted that for both designs, the majority group is the one with restored offset (P=.001).

8.
Rev Esp Cir Ortop Traumatol ; 66(6): T3-T10, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-35853606

RESUMO

OBJECTIVE: To analyse the clinical and radiologic results, the survival and complications obtained in 70 year or older patients who underwent cementless total knee arthroplasty (TKA). MATERIAL AND METHOD: An observational study of patients operated between January 2014 and December 2016 was carried out according to the Natural Knee model (Zimmer®, USA). The main variables were the Oxford Knee Score, the visual analogue scale, the presence of radiolucencies, complications, survival and reasons for revision. RESULTS: Of 104 TKA, 86 were available for revision. The median age was 76 years. The mean follow-up was 5.4 years (range 3.7-6.9). The Oxford Knee Score punctuation showed a median of 17 presurgical (range 0-40) and 37 post surgical (range 5-48), P<.001. The 87.2% of the patients obtained a clinically significant improvement. The median visual analogue scale punctuation was 8 for presurgical (range 4-10) and 2 for post surgical (range 1-9), P<.001. The 88.3% of the patients obtained a clinically significant decrease. Three months after the surgery, the 55.81% of the TKAs presented radiolucencies around the tibial plateau. At the end of the follow-up, radiolucencies were present in 30.23% of the TKAs. Survival from all causes was 91.86% at 77.2 months and 96.5% due to aseptic loosening. CONCLUSION: Cementless knee prostheses are a valid option in patients aged 70 or older, presenting good clinical, radiological and survival results.

9.
Rev Esp Cir Ortop Traumatol ; 66(1): 68-73, 2022.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-33663991

RESUMO

INTRODUCTION: One of the most frequently treated pathologies in our department are tendon lesions that affect the rotator cuff of the shoulder. There are different types of treatment for massive or irreparable tears. For a few years, a low-invasive technique was introduced based on the placement of a biodegradable subacromial spacer. The objective of the work is to analyse the results of our experience with the use of this device (InSpaceTM). MATERIAL AND METHOD: The study collects the results obtained in 25 patients with irreparable ruptures of rotator cuff defined by RM, in which they were implanted a balloon subacromial in our centre in the period from January 2015 - until December 2017. All patients were evaluated preoperatively and one year after surgery including the visual analogue scale (VAS), the Constant test (CS) and the QuickDASH (QD). RESULTS: Of the 25 patients, 5 patients (20%) were operated by arthroscopy and 20 (80%) By open approach (mini-open). A total of 22 patients completed the follow-up year. At 12 months, 64% of the patients obtained an improvement of at least 10 points in the CS. Patients departed from an initial average CS of 32 points that improved to 54.9 points of average in the postoperative evaluation at 12 months (average improvement 22.9 points; Value-p < 0.05). In terms of pain assessment, in our study, 87% of patients obtained an improvement of at least 2 points in the EVA at 12 months of follow-up (P-value < 0.05). Patients departed from an initial average EVA of 8.7 that improved to 3.7 points average at 12 months. 73% of the patients responded to be satisfied with the intervention and would return to the surgery. CONCLUSIóN: The results obtained in our series to one year of follow-up speak in favour of the use of the Subacromial Balloon (InSpaceTM), as a therapeutic option available for patients with irreparable ruptures of the rotator cuff. It can be used as an interim procedure, delaying the need for more invasive surgery, or as a definitive procedure in patients medically non-candidates for reverse arthroplasty. It is important to have clear indications of this procedure in order not to make mistakes.

10.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31668698

RESUMO

OBJECTIVE: To evaluate the use of WhatsApp as a clinical tool and determine the perception of orthopaedic surgeons of its usefulness. MATERIAL AND METHODS: Orthopaedic surgeons attending a scientific meeting were invited to complete an anonymous and structured survey on the use of the application in the clinical setting. RESULTS: A total of 41 (38%) surveys were correctly completed. Of the respondents, 100% had been either senders or receivers of clinical information via the application. Ninety-three percent had used the application to consult in relation to a clinical case. Of the respondents, 78% belonged to a WhatsApp group in which clinical information is shared: 71% agreed that communication between clinicians through WhatsApp is a useful tool for making therapeutic decisions. CONCLUSION: The use of WhatsApp for clinical purposes by orthopaedic surgeons is widespread. Most consider it a useful tool in therapeutic decision making.


Assuntos
Atitude do Pessoal de Saúde , Tomada de Decisão Clínica/métodos , Relações Interprofissionais , Aplicativos Móveis , Cirurgiões Ortopédicos , Ortopedia/métodos , Padrões de Prática Médica/estatística & dados numéricos , Adulto , Humanos , Pessoa de Meia-Idade , Projetos Piloto , Encaminhamento e Consulta , Espanha , Inquéritos e Questionários
11.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30795998

RESUMO

INTRODUCTION: In the Spanish population, previous studies related to mortality after hip fracture are based on patients aged 60 to 102years and did not stratify patients according to the type of fracture. The objective of this study was to identify the factors with influence on mortality at one postoperative year in patients aged 80years or older after a femoral neck fracture. MATERIAL AND METHOD: Retrospective study of cases and controls. Consecutive patients operated between 2015 and 2016 were included. Baseline characteristics, medical history and previous medication, analytical parameters, Charlson index, ASA scale, Barthel index and Pfeiffer questionnaire were studied. Surgical data and complications were recorded during follow-up. Survival was assessed by the Kaplan-Meier method and the variables that affected it by Cox regression. RESULTS: Mortality one year postoperatively was 21.1% and mean survival 10.3months (95%CI: 9.7-10.9). The Cox regression showed that age >87years, Barthel score ≤85 and the combination of anticoagulants with INR ≥1.5 were significant predictors of mortality during the first year of follow-up. CONCLUSION: The predictors of mortality during the first postoperative year after femoral neck fracture in octogenarian or older patients were: age>87years, physical dependence measured by a Barthel index score ≤85, and the use of anticoagulants with a INR ≥1.5 at admission.


Assuntos
Fraturas do Colo Femoral/mortalidade , Fatores Etários , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Estudos de Casos e Controles , Avaliação da Deficiência , Feminino , Fraturas do Colo Femoral/sangue , Fraturas do Colo Femoral/cirurgia , Fixação de Fratura/métodos , Humanos , Coeficiente Internacional Normatizado , Estimativa de Kaplan-Meier , Masculino , Curva ROC , Análise de Regressão , Estudos Retrospectivos , Distribuição por Sexo , Espanha/epidemiologia , Fatores de Tempo
12.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): 26-34, Ene-Feb, 2024. tab, graf
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-229667

RESUMO

Introducción y objetivos: Los vástagos primarios con cuellos modulares fueron introducidos con la ventaja teórica de restaurar la anatomía de la cadera de forma más precisa. Sin embargo, la presencia de un segundo encaje se ha asociado a una mayor corrosión y liberación de detritos metálicos. El objetivo de nuestro estudio es cuantificar los valores séricos de cromo y de cobalto, y analizar su evolución temporal durante cinco años. Material y métodos: Se presenta una serie prospectiva de 61 pacientes intervenidos de artroplastia total de cadera primaria mediante la implantación del vástago HMAX-M® (Limacorporate, San Daniele, Italia) en los que se realizó una determinación sérica de cromo y cobalto a los seis meses, a los dos años y a los cinco años. Resultados: Nuestra serie presenta una elevación progresiva de los niveles de cromo, con una diferencia significativa entre los valores de cromo a los seis meses (0,35±0,18) y los cinco años (0,52±0,36), p=0,01. Respecto al cobalto, se observa una elevación estadísticamente significativa entre los seis meses y los dos años y una posterior estabilización hasta los cinco años, siendo la media de cobalto a los seis meses (1,17±0,8) significativamente menor que a los dos años (2,63±1,76) y a los cinco años (2,84±2,1), p=0,001. Conclusión: Se ha observado una elevación de los niveles séricos de cobalto en aquellos pacientes a los que se les implantó un vástago con cuello modular. Los resultados obtenidos en este estudio han limitado el uso de vástagos con cuello modular en nuestra práctica habitual.(AU)


Introduction and objectives: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. Material and methods: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. Results: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. Conclusion: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.(AU)


Assuntos
Humanos , Masculino , Feminino , Cromo/administração & dosagem , Cobalto/administração & dosagem , Artroplastia de Quadril , Quadril/cirurgia , Íons , Ferro/sangue , Estudos Prospectivos , Traumatologia , Ortopedia , Procedimentos Ortopédicos , Lesões do Quadril , Itália
13.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): T26-T34, Ene-Feb, 2024. tab, graf
Artigo em Inglês | IBECS (Espanha) | ID: ibc-229668

RESUMO

Introducción y objetivos: Los vástagos primarios con cuellos modulares fueron introducidos con la ventaja teórica de restaurar la anatomía de la cadera de forma más precisa. Sin embargo, la presencia de un segundo encaje se ha asociado a una mayor corrosión y liberación de detritos metálicos. El objetivo de nuestro estudio es cuantificar los valores séricos de cromo y de cobalto, y analizar su evolución temporal durante cinco años. Material y métodos: Se presenta una serie prospectiva de 61 pacientes intervenidos de artroplastia total de cadera primaria mediante la implantación del vástago HMAX-M® (Limacorporate, San Daniele, Italia) en los que se realizó una determinación sérica de cromo y cobalto a los seis meses, a los dos años y a los cinco años. Resultados: Nuestra serie presenta una elevación progresiva de los niveles de cromo, con una diferencia significativa entre los valores de cromo a los seis meses (0,35±0,18) y los cinco años (0,52±0,36), p=0,01. Respecto al cobalto, se observa una elevación estadísticamente significativa entre los seis meses y los dos años y una posterior estabilización hasta los cinco años, siendo la media de cobalto a los seis meses (1,17±0,8) significativamente menor que a los dos años (2,63±1,76) y a los cinco años (2,84±2,1), p=0,001. Conclusión: Se ha observado una elevación de los niveles séricos de cobalto en aquellos pacientes a los que se les implantó un vástago con cuello modular. Los resultados obtenidos en este estudio han limitado el uso de vástagos con cuello modular en nuestra práctica habitual.(AU)


Introduction and objectives: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. Material and methods: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. Results: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. Conclusion: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.(AU)


Assuntos
Humanos , Masculino , Feminino , Cromo/administração & dosagem , Cobalto/administração & dosagem , Artroplastia de Quadril , Quadril/cirurgia , Íons , Ferro/sangue , Estudos Prospectivos , Traumatologia , Ortopedia , Procedimentos Ortopédicos , Lesões do Quadril , Itália
14.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30683523

RESUMO

INTRODUCTION: One of the most frequent complications after a total hip arthroplasty (THA) is bleeding, intravenous tranexamic acid (TXA) is used to reduce it. We considered it necessary to carry out a study to clarify which administration route is superior. MATERIAL AND METHOD: Prospective, controlled and randomized study in 2 arms carried out between February 2017 and February 2018. 15mg/kg of intravenous TXA were administered in group-A and 2gr of intra-articular TXA in group-B. The values of haemoglobin and haematocrit were evaluated at 24h-72h, blood loss volume, drained blood volume, transfusions and complications. RESULTS: 78 patients were included, 31 with intravenous treatment and 47 with intra-articular. The decrease of haemoglobin in the intravenous group was 3.15±1.64g/dl in 24h and 3.75±1.56g/dl in 72h, the haematocrit decreased by 10.4±4.17% in 24h and 11.85±4.15% in 72h. In the intra-articular group there was a haemoglobin fall of 3.03±1.30g/dl in 24h and 3.22±1.2g/dl in 72h and the haematocrit fell by 10.66±3.6% and 12,11±3.29% in 24 and 72h (P>.05). The mean drainage in 24h was 195.80ml in group-A versus 253.93ml in group-B (P>.05) and in 48h it was 225.33ml in group-A and 328.19ml in group-B (P=.009). The intravenous group lost an average of 1,505ml of blood compared to the 11,280ml of the intra-articular group. In 5.1% of the cases, transfusions were necessary. We had no secondary complications. CONCLUSIONS: The different routes of administration of TXA in THA have a similar effect in the reduction of postoperative bleeding. There was no evidence of an increase in complications.


Assuntos
Antifibrinolíticos/administração & dosagem , Artroplastia de Quadril , Hemorragia Pós-Operatória/prevenção & controle , Ácido Tranexâmico/administração & dosagem , Administração Intravenosa , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
15.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30348517

RESUMO

OBJECTIVE: To evaluate the clinical results and survival of primary hip prosthesis with ceramic delta bearings (C-C) with a minimum follow-up of 5years. MATERIAL AND METHOD: A total of 205 primary hip arthroplasties performed between 2008 and 2012 were studied. The clinical results, pre-surgical and at 5years of follow-up were evaluated using the Harris Hip Score (HHS), the Short Form-36 (SF-36), the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and the visual analogue scale (VAS). The position of the prosthetic components, periprosthetic osteolysis, loosening of the prosthetic components and ruptures of the ceramic components were studied radiologically. The adverse events related to bearings were recorded according to their diameter, paying special attention to prosthetic dislocations and the presence of noise. Survival with an endpoint of prosthetic revision for any cause was estimated using the Kaplan-Meier method. RESULTS: Significant improvements were obtained in the HHS (88.7% of good/excellent results), SF36, WOMAC and EVA, P<.001. There were 19 adverse events related to the prosthesis (4 periprosthetic fractures, 4 dislocations, 2 superficial infections, 1 mobilization of the cup, 2 noises, 4 aseptic loosenings and 2 breaks of the prosthetic neck); 47.3% needed revision. The cumulative survival of the prostheses was 97.5% (95%CI: 96.4-98.5). No differences were found in survival, prosthetic adverse events, noise incidence or dislocations and clinical results among the different diameters used. CONCLUSIONS: Primary hip prostheses with fourth-generation ceramic bearings showed good survival in the medium term, and good clinical results.


Assuntos
Artroplastia de Quadril , Cerâmica , Prótese de Quadril , Desenho de Prótese , Falha de Prótese , Adulto , Idoso , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30213472

RESUMO

OBJECTIVE: To identify the factors with influence on the development of avascular necrosis of the femoral head (ANFH) in patients with non-displaced femoral neck fractures treated with internal fixation. MATERIAL AND METHOD: Retrospective study of cases and controls. We included non-displaced femoral neck fractures treated with internal fixation, and that presented ANFH with a postoperative follow-up of at least 2 years. The baseline variables, active comorbidities of the patients, the time for surgery and the number of screws used for osteosynthesis were recorded. Comparisons were made between the groups, those that presented ANFH and those that did not. By area under the curve, the cut-offs of age and time for surgery were located. RESULTS: An association between sex, active comorbidities and number of screws used and the development of ANFH was not observed. The cut-off points for age and time for surgery were≤69 years and≤43hours, respectively. No significant correlation was observed for the cut-off time for surgery. In the multivariate analysis, age≤69 years was a significant predictor of the development of ANFH (OR 4.6; 95% CI 1.1 to 17.9; P=.028). CONCLUSIONS: The patients aged 69 years or younger were at increased risk of developing ANFH after undisplaced femoral neck fracture treated with percutaneous screws.


Assuntos
Fraturas do Colo Femoral/complicações , Fraturas do Colo Femoral/cirurgia , Necrose da Cabeça do Fêmur/etiologia , Fixação Interna de Fraturas , Complicações Pós-Operatórias/etiologia , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Pinos Ortopédicos/estatística & dados numéricos , Estudos de Casos e Controles , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Risco
17.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29217349

RESUMO

OBJECTIVE: To assess the radiological and functional outcome of arthrodesis of the 4th and 5th finger using the APEX™ (Extremity Medical, Parsippany,NJ)intermedullary interlocking screw system in patients with severe recurrence of Dupuytren's disease. MATERIAL AND METHOD: The DASH questionnaire and the VAS scale were used to assess the clinical outcomes. The angle of arthrodesis, fusion time and implant fixation were evaluated on x-rays. The patients were monitored for complications during surgery and the follow-up period. RESULTS: The sample comprised 6 patients. Mean follow up was 19.6 months. All of the patients presented clinical and radiological evidence of fusion at 8 weeks, with fusion angles of 30° (3) and 45° (3). There were no complications and none of the implants had to be removed. The functional outcomes in these patients were poor. CONCLUSION: The system offers a reliable method for IPJ arthrodesis at a precise angle. It promotes stable fixation that does not require prolonged immobilisation. It can be used together with other procedures on the hand with severe recurrence of DD. The functional outcomes for this group of patients using this device were poor.


Assuntos
Artrodese/instrumentação , Parafusos Ósseos , Contratura de Dupuytren/cirurgia , Articulações dos Dedos/cirurgia , Idoso , Artrodese/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
19.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 66(6): 445-453, Nov-Dic. 2022. ilus, tab
Artigo em Espanhol | IBECS (Espanha) | ID: ibc-210655

RESUMO

Introducción y objetivos: Los vástagos con doble modularidad buscan restaurar de forma más precisa la anatomía al permitir ajustes intraoperatorios gracias a los cuellos modulares. Nuestro objetivo es comparar la corrección radiográfica de la longitud con el vástago H MAX-M® frente a su homólogo monobloque H MAX-S®. Material y métodos: Se realizó un estudio de cohortes prospectivo mediante muestreo consecutivo sobre pacientes intervenidos de artroplastia total de cadera primaria con el diagnóstico de coxartrosis entre el año 2011 y 2015. Un brazo de la cohorte incluyó a los pacientes intervenidos con vástago modular y el otro con vástago monobloque. Se midió la longitud en la radiografía anteroposterior de pelvis en carga a los seis meses. Las medias de las mediciones obtenidas para cada brazo de la cohorte se compararon entre sí. Resultados: No se han observado diferencias estadísticamente significativas en la corrección de la disimetría entre ambos grupos determinada como la diferencia de longitud entre la cadera operada y la cadera contralateral (p=0,106). Tampoco se observaron diferencias en los valores postoperatorios de longitud (p=0,053). Cabe decir que tanto para el vástago modular como para el vástago monobloque el grupo mayoritario es aquel con longitud restaurada (84,1 y 80,4%, respectivamente; p=0,001). Conclusión: A pesar de la ventaja teórica de la modularidad y que disponer de piezas intercambiables podría ser de gran interés, en nuestro estudio no hemos podido demostrar que exista una superioridad de los diseños modulares frente al monoblock para control de la disimetría postoperatoria.(AU)


Introduction and objective: Dual modularity stems seek to more precisely restore anatomy by allowing intraoperative adjustments thanks to modular necks. Our aim is to compare the radiographic length correction with the H MAX-M® Stem versus its monoblock counterpart H MAX-S®. Material and methods: A prospective cohort study was carried out through consecutive sampling on patients who underwent primary total hip arthroplasty with coxarthrosis diagnosis between 2011 and 2015. One arm of the cohort included patients who were operated with a modular stem and the other with a monobloc stem. Length was measured on the anteroposterior pelvic-bearing radiograph at six months. The mean of the measurements obtained for each arm of the cohort were compared with each other. Results: No statistically significant differences were observed in the correction of asymmetry between both groups, determined as the difference in length between the operated hip and the contralateral hip (P=.106). Nor were differences observed in postoperative length values (P=.053). It should be noted that for both the modular stem and the monobloc stem, the majority group is the one with restored length (84.1% and 80.4%, respectively; P=.001). Conclusion: Despite the theoretical advantage of modularity and that having interchangeable parts could be of great interest, in our study, we have not been able to demonstrate a superiority of modular designs compared to monoblock for control of postoperative leg length discrepancy.(AU)


Assuntos
Humanos , Masculino , Feminino , Lesões do Quadril , Quadril , Artroplastia , Osteoartrite do Quadril , Ataxia Cerebelar , Estudos de Coortes , Estudos Retrospectivos , Ortopedia , Ferimentos e Lesões , Traumatologia
20.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 66(6): T27-T35, Nov-Dic. 2022. ilus, tab
Artigo em Inglês | IBECS (Espanha) | ID: ibc-210669

RESUMO

Introducción y objetivos: Los vástagos con doble modularidad buscan restaurar de forma más precisa la anatomía al permitir ajustes intraoperatorios gracias a los cuellos modulares. Nuestro objetivo es comparar la corrección radiográfica de la longitud con el vástago H MAX-M® frente a su homólogo monobloque H MAX-S®. Material y métodos: Se realizó un estudio de cohortes prospectivo mediante muestreo consecutivo sobre pacientes intervenidos de artroplastia total de cadera primaria con el diagnóstico de coxartrosis entre el año 2011 y 2015. Un brazo de la cohorte incluyó a los pacientes intervenidos con vástago modular y el otro con vástago monobloque. Se midió la longitud en la radiografía anteroposterior de pelvis en carga a los seis meses. Las medias de las mediciones obtenidas para cada brazo de la cohorte se compararon entre sí. Resultados: No se han observado diferencias estadísticamente significativas en la corrección de la disimetría entre ambos grupos determinada como la diferencia de longitud entre la cadera operada y la cadera contralateral (p=0,106). Tampoco se observaron diferencias en los valores postoperatorios de longitud (p=0,053). Cabe decir que tanto para el vástago modular como para el vástago monobloque el grupo mayoritario es aquel con longitud restaurada (84,1 y 80,4%, respectivamente; p=0,001). Conclusión: A pesar de la ventaja teórica de la modularidad y que disponer de piezas intercambiables podría ser de gran interés, en nuestro estudio no hemos podido demostrar que exista una superioridad de los diseños modulares frente al monoblock para control de la disimetría postoperatoria.(AU)


Introduction and objective: Dual modularity stems seek to more precisely restore anatomy by allowing intraoperative adjustments thanks to modular necks. Our aim is to compare the radiographic length correction with the H MAX-M® Stem versus its monoblock counterpart H MAX-S®. Material and methods: A prospective cohort study was carried out through consecutive sampling on patients who underwent primary total hip arthroplasty with coxarthrosis diagnosis between 2011 and 2015. One arm of the cohort included patients who were operated with a modular stem and the other with a monobloc stem. Length was measured on the anteroposterior pelvic-bearing radiograph at six months. The mean of the measurements obtained for each arm of the cohort were compared with each other. Results: No statistically significant differences were observed in the correction of asymmetry between both groups, determined as the difference in length between the operated hip and the contralateral hip (P=.106). Nor were differences observed in postoperative length values (P=.053). It should be noted that for both the modular stem and the monobloc stem, the majority group is the one with restored length (84.1% and 80.4%, respectively; P=.001). Conclusion: Despite the theoretical advantage of modularity and that having interchangeable parts could be of great interest, in our study, we have not been able to demonstrate a superiority of modular designs compared to monoblock for control of postoperative leg length discrepancy.(AU)


Assuntos
Humanos , Masculino , Feminino , Lesões do Quadril , Quadril , Artroplastia , Osteoartrite do Quadril , Ataxia Cerebelar , Estudos de Coortes , Estudos Retrospectivos , Ortopedia , Ferimentos e Lesões , Traumatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa