1.
J Pediatr ; 163(6): 1722-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24094878

RESUMO

OBJECTIVE: To compare the diagnostic performance of 2 height-independent equations used to calculate estimated glomerular filtration rate (eGFR), those of Pottel (eGFR-Pottel) and the British Columbia Children's Hospital (BCCH) (eGFR-BCCH), with the commonly used Schwartz equation (eGFR-Schwartz). STUDY DESIGN: We externally validated eGFR-Pottel and eGFR-BCCH in a well-characterized pediatric patient population (n = 152) and compared their diagnostic performance with that of eGFR-Schwartz using Bland-Altman analysis. All patients underwent glomerular filtration rate measurement using the gold standard single-injection inulin clearance method (GFR-inulin). RESULTS: Median GFR-inulin was 92.0 mL/min/1.73 m² (IQR, 76.1-107.4 mL/min/1.73 m²). Compared with GFR-inulin, the mean bias for eGFR-Schwartz was -10.1 mL/min/1.73 m(2) (95% limits of agreement [LOA], -77.5 to 57.2 mL/min/1.73 m(2)), compared with -12.3 mL/min/1.73 m² (95% LOA, -72.6 to 47.9 mL/min/1.73 m(2)) for eGFR-Pottel and -22.1 mL/min/1.73 m² (95% LOA, -105.0 to 60.8 mL/min/1.73 m(2)) for eGFR-BCCH. eGFR-Pottel showed comparable accuracy to eGFR-Schwartz, with 77% and 76% of estimates within 30% of GFR-inulin, respectively. eGFR-BCCH was less accurate than eGFR-Schwartz (66% of estimates within 30% of GFR-inulin; P < .01). CONCLUSION: The performance of eGFR-Pottel is superior to that of eGFR-BCCH and comparable with that of eGFR-Schwartz. eGFR-Pottel is a valid alternative to eGFR-Schwartz in children and could be reported by the laboratory if height data are not available.


Assuntos
Estatura , Taxa de Filtração Glomerular , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Matemática , Estudos Retrospectivos , Adulto Jovem
2.
Clin Chem Lab Med ; 51(6): 1191-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23314539

RESUMO

BACKGROUND: Celiac disease (CD) is an inflammatory disorder of the small intestine induced by gluten ingestion. CD has a strong genetic association with human leukocyte antigen (HLA)-DQ2.5 and HLA-DQ8. The absence of HLA-DQ2.5 and HLA-DQ8 has a strong negative predictive value for CD. Genetic screening of HLA-DQ2.5 and HLA-DQ8 in patients at risk is of great value. METHODS: We designed, developed, and validated a multiplex assay based on multiplex ligation-dependent probe amplification (MLPA) technology, allowing the simultaneous detection of DQA1*05-DQB1*02, encoding HLA-DQ2.5, and DQA1*03-DQB1*03:02, encoding HLA-DQ8. The amplified products were separated and identified using capillary electrophoresis. RESULTS: When compared with a polymerase chain reaction followed by single-strand conformation polymorphism/ heteroduplex analysis, one discrepancy was found. Sequencing analysis showed that the developed MLPA assay result was correct. Furthermore, we demonstrated that the MLPA method is able to distinguish between the heterozygote and homozygote expression of HLA-DQ2.5 or HLA-DQ8. CONCLUSIONS: This study shows that it is possible to rapidly and accurately screen for the absence of HLA-DQ2.5 and HLA-DQ8 using MLPA, excluding patients at risk for CD for further serological or histological follow-up. In addition, MLPA might be an accurate tool to screen for other specific HLA types in the context of disease association in a diagnostic laboratory setting.


Assuntos
Doença Celíaca/diagnóstico , Doença Celíaca/imunologia , Antígenos HLA-DQ/análise , Antígenos HLA-DQ/biossíntese , Reação em Cadeia da Polimerase Multiplex/métodos , Doença Celíaca/genética , Eletroforese Capilar/métodos , Predisposição Genética para Doença , Antígenos HLA-DQ/genética , Humanos , Reação em Cadeia da Polimerase/métodos , Polimorfismo Conformacional de Fita Simples , Fatores de Risco , Análise de Sequência de DNA
3.
Clin Chem Lab Med ; 49(12): 1979-85, 2011 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-21892909

RESUMO

BACKGROUND: Human leukocyte antigen B27 (HLA-B27) is strongly associated with ankylosing spondylitis. The B27 allele is present in 90% of patients with this disease, whereas it is present in only 9% of Caucasians. Molecular detection of HLA-B27 is traditionally based on allele specific amplification of exon 2 (Olerup method) or exon 3 (Dominguez method) by PCR, followed by gel analysis. METHODS: We developed a real-time TaqMan PCR based on the Dominguez method with a ß-Globin PCR as internal control. RESULTS: A total of 544 clinical samples were used to compare the real-time TaqMan PCR with the traditional Dominguez PCR, the traditional Olerup PCR and a commercial Olerup based HLA-B27 detection kit (Olerup SSPTM HLA-B27, GenoVision). While 542 samples gave concordant results, two samples showed discrepancies and were further analyzed. One sample that showed a discrepancy was negative with the traditional Olerup method and positive with the three other procedures. Sequencing analysis showed the presence of HLA-B*2712 in this sample. The other sample, positive with both Olerup based PCRs and negative with both Dominguez based methods, turned out to be positive for HLA-B*2707 by sequence analysis. CONCLUSIONS: With a correct result for 543 out of 544 samples (99.8%), we consider our real-time HLA-B27 PCR is a reliable method to detect HLA-B27 in the Dutch population, with reduced hands-on time and contamination risk compared to traditional PCR methods.


Assuntos
Antígeno HLA-B27/genética , Reação em Cadeia da Polimerase em Tempo Real , População Branca/genética , Alelos , Éxons , Predisposição Genética para Doença , Humanos , Países Baixos , Análise de Sequência de DNA , Espondilite Anquilosante/genética
5.
Am J Clin Pathol ; 136(4): 631-6, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21917687

RESUMO

The aim of our study was to assess the fetal RBC count in maternal blood during uncomplicated pregnancies from 26 weeks onward. We used a flow cytometric method specifically designed for use in a routine hematology analyzer. Pregnant women were recruited through midwives. The participating laboratories used the FMH QuikQuant method (Trillium Diagnostics, Brewer, ME) in a CELL-DYN Sapphire hematology analyzer (Abbott Diagnostics, Santa Clara, CA). The method is based on a monoclonal antibody to hemoglobin F. Flow cytometric data were analyzed by 2 independent observers. The 95th percentile reference range was estimated according to Clinical and Laboratory Standards Institute guidelines. A total of 236 samples were statistically analyzed. Gestational ages ranged from 21.6 to 41 weeks (mean, 32.0 weeks), and the fetal RBC count in maternal blood ranged from 0.00% to 0.50% (median, 0.025%). The fetal RBC count in maternal blood shows no correlation with gestational age. The established reference range during normal pregnancy is less than 0.125%.


Assuntos
Contagem de Eritrócitos/métodos , Eritrócitos/citologia , Citometria de Fluxo/métodos , Gravidez/sangue , Separação Celular , Feminino , Transfusão Feto-Materna/sangue , Feto , Humanos , Valores de Referência