Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Med Econ ; 26(1): 1555-1565, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37961942

RESUMO

BACKGROUND: Establishment of dedicated Stroke Centers has shown to be effective on the outcome of patients with acute ischemic stroke, as well as mechanical thrombectomy (MTE) in acute large vessel occlusion. The cost-effectiveness of this treatment has also been proven in several countries, but so far not in Switzerland. METHODS: We compare the pathways and economic impact of patients with acute large vessel occlusions causing acute ischemic stroke before the establishment of the stroke center and MTE in 2016 with the time afterwards in the years 2016-2020. Local data from the Swiss Stroke Registry and hospital accounting as well as economic data from a healthcare insurance company was used for evaluation in an economic model. Both payer and societal perspectives were considered, and probabilistic sensitivity analysis was undertaken to explore uncertainty. RESULTS: Establishment of a new Stroke Center in Central Switzerland increased the absolute number of thrombectomies from 0 in 2015 to 55 in 2016 to 83 in 2020, as well as the percentage of MTE in large vessel occlusions (LVO) from 50.9% in 2016 to 58.2% in 2020. Over a 15-year horizon, predicted average additional costs of CHF 7,978 were associated with the establishment of a new stroke center, as well as 0.60 quality-adjusted life-years (QALY) per patient and an additional survival of 0.59 years per patient. The calculated incremental cost-effectiveness ratio was therefore CHF 13,297 per QALY gained. When societal costs were included, the new stroke care model was predicted to dominate the old care model. Robustness of model results was confirmed via probabilistic sensitivity analysis. LIMITATIONS: The results rely on data from a single stroke center and, therefore, cannot be generalized. CONCLUSIONS: Establishment of a new Stroke Center can be cost-effective and provide better outcomes in terms of functional independence as well as quality-adjusted life-years.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Suíça , Análise Custo-Benefício , Fatores Socioeconômicos , Anos de Vida Ajustados por Qualidade de Vida
2.
Hand Surg Rehabil ; 41(3): 341-346, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35189401

RESUMO

Recently, biodegradable implants made from magnesium (Mg) alloys have been developed to obviate the need for later implant removal. Mg-based cannulated compression screws (CCS) are ideal for intramedullary screw (IMS) fixation of metacarpal fractures. The present study aimed at investigating the torque acting on Mg-based CCS at failure and at intramedullary metacarpal insertion. The devices were CE certified Magnezix 2.7 and 3.2 mm CCSs (Syntellix®, Hannover, Germany). Torque at failure was measured in a synthetic bone model using a standardized polyurethane foam block. In a second assessment, insertional torque was measured in ten cadaveric metacarpal bones. Mean torque at failure for the 2.7 mm and 3.2 mm CCSs was 42.8 Ncm (±1.9 Ncm) and 63.0 Ncm (±2.2 Ncm), respectively. In the human cadaver model, the torque distribution curve at metacarpal insertion showed three peaks. The highest reached 53.6% of the lowest torque at failure measured in the synthetic bone model for the 3.2 CCS (31.4 vs. 58.6 Ncm). The mean difference between peak torque at metacarpal insertion and torque at failure was 38.3 Ncm (99% CI [33.6, 43.0 Ncm], p < 0.0001). In terms of torque load, Mg-based CCSs are suitable for IMS fixation of metacarpal fractures. Biodegradable implants may represent an important improvement of this treatment method; confirmation by in-vivo studies is needed.


Assuntos
Fraturas Ósseas , Ossos Metacarpais , Fenômenos Biomecânicos , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Humanos , Magnésio , Ossos Metacarpais/cirurgia , Torque
3.
Phys Med Biol ; 27(10): 1221-9, 1982 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-7146095

RESUMO

An integral equation relating the lateral absorbed dose profile of a photon beam to the resultant absorbed dose distribution during single-turn rotating-beam therapy has been set up and solved for the case of a cylindrical phantom with the axis of rotation coinciding with the axis of symmetry of the cylinder. In the first approximation the results obtained are also valid when the axis of rotation is somewhat off-centred, even in a phantom that deviates from circular symmetry, provided the rotation is performed in both clockwise and counter clockwise directions. The calculated dose profiles indicate that improved dose uniformity can be achieved using a new type of non-linear wedge-shaped filter, which can easily be designed using the derived general analytic solution to the integral equation.


Assuntos
Radioterapia/instrumentação , Humanos , Modelos Biológicos , Radioterapia/métodos , Dosagem Radioterapêutica , Rotação , Tomografia Computadorizada por Raios X
4.
Rofo ; 176(4): 556-63, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15088181

RESUMO

PURPOSE: To evaluate the impact of different iodine concentrations of intravenous contrast agent on hepatic and vascular enhancement during arterial and porto-venous phase imaging using a 4-channel multi-detector row CT (MDCT). MATERIAL AND METHODS: One hundred consecutive patients referred for triphasic abdominal MDCT were randomly assigned into four groups receiving different iodine concentration (200, 250, 300 or 350 mg/ml). Non-contrast, arterial, and porto-venous phase 4-channel MDCT imaging was performed (VolumeZoom, Siemens, Germany). A fixed volume of 150 ml intravenous contrast agent at a rate of 3 ml/s was injected using an automatic bolus-tracking system (Care Bolus, Siemens, Erlangen). Hepatic and vascular enhancement values were measured over time and non-contrast values were subtracted in order to compute arterial and porto-venous mean hepatic (MHE) and mean aortic (MAE) enhancement for each group. Mean change of enhancement > 80 HU for the aorta and > 40 HU for the liver during porto-venous phase imaging was considered as sufficient enhancement. RESULTS: All groups achieved sufficient vascular enhancement during arterial phase imaging; MAE with 350 mg/ml (222 HU) and 300 mg/ml (213HU) was significantly better than with 250 mg (196HU) and 200 mg/ml (169 HU), whereas MHE showed no statistically significant difference between the groups (range 16 - 25 HU). Porto-venous MHE showed increased enhancement with larger concentrations, with significant differences among the groups. Only the higher concentration groups (350 mg/ml und 300 mg/ml) fulfilled in every individual the guidelines for sufficient porto-venous MHE. In the lower concentration groups, 8 patients with 200 mg/ml and 3 patients with 250 mg/ml showed enhancement values below the required minimum. CONCLUSION: A decrease in iodine contrast agent down to 200 mg/ml concentration is only tenable for propose of vascular aortic and hepatic arterial enhancement, whereas hepatic porto-venous phase imaging still requires concentrations at or above the level of 300 mg/ml.


Assuntos
Aortografia , Meios de Contraste/administração & dosagem , Iodo/administração & dosagem , Fígado/diagnóstico por imagem , Radiografia Abdominal , Tomografia Computadorizada por Raios X/métodos , Ácidos Tri-Iodobenzoicos/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Aortografia/métodos , Interpretação Estatística de Dados , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia Abdominal/métodos , Fatores de Tempo
5.
Eur J Radiol ; 82(12): e873-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24074648

RESUMO

OBJECTIVES: To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS: An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS: Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS: Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.


Assuntos
Detecção Precoce de Câncer/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Competência Profissional , Doses de Radiação , Software , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Relação Dose-Resposta à Radiação , Detecção Precoce de Câncer/instrumentação , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Validação de Programas de Computador , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa