Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
J Cardiovasc Electrophysiol ; 27(12): 1411-1419, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27569695

RESUMO

INTRODUCTION: Although catheter ablation (CA) for atrial fibrillation (AF) is commonly used to improve symptoms, AF recurrence is common and new tools are needed to better inform patient selection for CA. Left atrial function index (LAFI), an echocardiographic measure of atrial mechanical function, has shown promise as a noninvasive predictor of AF. We hypothesized that LAFI would relate to AF recurrence after CA. METHODS AND RESULTS: All AF patients undergoing index CA were enrolled in a prospective institutional AF Treatment Registry between 2011 and 2014. LAFI was measured post hoc from pre-ablation clinical echocardiographic images in 168 participants. Participants were mostly male (33% female), middle-aged (60 ± 10 years), obese and had paroxysmal AF (64%). Mean LAFI was 25.9 ± 17.6. Over 12 months of follow-up, 78 participants (46%) experienced a late AF recurrence. In logistic regression analyses adjusting for factors known to be associated with AF, lower LAFI remained associated with AF recurrence after CA [OR 0.04 (0.01-0.67), P = 0.02]. LAFI discriminated AF recurrence after CA slightly better than CHADS2 (C-statistic 0.60 LAFI, 0.57 CHADS2). For participants with persistent AF, LAFI performed significantly better than CHADS2 score (C statistic = 0.79 LAFI, 0.56 CHADS2, P = 0.02). CONCLUSION: LAFI, an echocardiographic measure of atrial function, is associated with AF recurrence after CA and has improved ability to discriminate AF recurrence as compared to the CHADS-2 score, especially among persistent AF patients. Since LAFI can be calculated using standard 2D echocardiographic images, it may be a helpful tool for predicting AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Ecocardiografia , Átrios do Coração/cirurgia , Idoso , Área Sob a Curva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Ablação por Cateter/efeitos adversos , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Pacing Clin Electrophysiol ; 34(12): 1593-9, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21819434

RESUMO

BACKGROUND: The effect of atrial pacing on the incidence of atrial fibrillation (AF) is unknown. Furthermore, the threshold of ventricular pacing that is associated with a higher incidence of AF has yet to be determined. Thus, we set out to determine the optimal pacing modality in patients with sinus node dysfunction (SND) for the prevention of AF. METHODS: Individual patient data from four contemporary pacemaker studies were gathered and analyzed. Since AF would inherently lead to a reduction in atrial pacing, percent atrial and ventricular pacing (%AP and %VP) were determined at the first follow-up visit and then used as a surrogate for all endpoints. Patients with >5 minutes of AF at the first visit were excluded. The primary endpoint was defined as 7 consecutive days of AF. RESULTS: A total of 1,507 patients were included. During a mean follow-up of 14.3 ± 8.7 months, 77 patients developed AF (annual rate of 4.3%). The incidence of AF in the first (0-32%), second (32-66%), third (66-89%), and fourth (89-100%) quartiles of %AP was 1.3%, 5.3%, 5.8%, and 8.0%, respectively (P < 0.001). A multivariable analysis found that pacing above the first quartile was associated with a relative risk of 2.93 (95% confidence interval 1.16-7.39, P = 0.023). The grouping of %VP into first (0-2%), second (2-7%), third (7-84%), and fourth (84-100%) quartiles yielded an AF incidence of 2.4%, 3.4%, 6.6%, and 8.0%, respectively (P = 0.001). CONCLUSION: We demonstrated that in patients with SND both atrial and ventricular pacing are associated with a higher incidence of AF.


Assuntos
Fibrilação Atrial/epidemiologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Marca-Passo Artificial , Síndrome do Nó Sinusal/terapia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/etiologia , Terapia de Ressincronização Cardíaca/métodos , Humanos , Incidência , Pessoa de Meia-Idade
3.
Pacing Clin Electrophysiol ; 33(8): 1020-30, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20545869

RESUMO

OBJECTIVES: The CAPTURE study evaluated the accuracy of automated atrial and right ventricular (RV) threshold algorithms. BACKGROUND: Modern pacemakers include many added features designed to improve the ease of patient follow-up, as well as algorithms to reduce pacing outputs and/or reduce the atrial or ventricular pacing percentages, thus improving longevity. METHODS: Automated atrial and RV threshold measurements were assessed versus manual measurements at 6 months. The projected longevity was assessed and compared between subjects with the threshold-tracking feature On versus Off. In addition, the projected longevity effect of device features to reduce atrial pacing and reduce ventricular pacing, and device characteristics such as battery size and high impedance leads (> or =1,000 ohms), was investigated. RESULTS: Atrial and RV manual versus automatic measurements were equivalent in 683 of 691 subjects (98.8%) and 736 of 746 subjects (98.7%), respectively. Thresholds were stable with 99.6% of atrial and 99.2% of RV consecutive measurements within +/-0.25V. Algorithms for threshold tracking, reducing ventricular pacing, and reducing atrial pacing were associated with 0.8, 0.9, and 0.2 years projected longevity improvements. High impedance leads were associated with a 0.8-year projected longevity improvement. Approximately 2 years of longevity improvement was projected for a 1-cc increase in device size. CONCLUSIONS: The atrial and RV algorithms were accurate and reliable in all leads tested. Threshold tracking, reduced ventricular pacing, and high impedance leads result in increased device longevity. Battery capacity was the strongest determinant of increased projected longevity.


Assuntos
Estimulação Cardíaca Artificial , Fontes de Energia Elétrica , Marca-Passo Artificial , Idoso , Algoritmos , Falha de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino
4.
Gastrointest Endosc ; 70(6): 1093-7, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19640524

RESUMO

BACKGROUND: There is a lack of prospective, randomized studies comparing the diagnostic yield and complication rates of 22-gauge and 25-gauge needles during EUS-FNA of solid pancreatic masses. OBJECTIVES: Our primary aim was to compare the diagnostic yield of 22-gauge and 25-gauge needles. Secondary aims included determining the number of needle passes performed, ease of needle passage, and complications. DESIGN: Prospective, randomized study. SETTING: Tertiary referral centers at Yale University School of Medicine, New Haven, Connecticut, and Virginia Piper Cancer Institute, Minneapolis, Minnesota. PATIENTS: Patients with a suspected solid pancreatic mass from February 2007 to June 2008 were enrolled. INTERVENTIONS: Patients were randomized to EUS-FNA with a 22-gauge or 25-gauge needle. MAIN OUTCOME MEASUREMENTS: A diagnostic result was defined as cytology findings positive for malignant cells. RESULTS: A total of 131 patients were enrolled: EUS-FNA was performed with a 22-gauge needle in 64 patients and with a 25-gauge needle in 67 patients. Cytology was diagnostic in 120 (91.6%) of 131 patients overall: 56 (87.5%) of 64 with 22-gauge needles and 64 (95.5%) of 67 with 25-gauge needles (no statistically significant difference was found between the 2 groups; P=.18). A similar number of passes was performed in both arms (mean [SD] 2.6 [1.2] each; P=.96). There were no complications in either group. LIMITATION: A larger number of patients is needed to determine small differences in diagnostic yield. CONCLUSIONS: This is the first prospective, randomized trial comparing 22-gauge and 25-gauge needles in EUS-FNA of solid pancreatic masses. We achieved equally high diagnostic yields by using a similar number of passes, showing that 25-gauge needles are an effective alternative to 22-gauge needles.


Assuntos
Biópsia por Agulha Fina/instrumentação , Endossonografia , Agulhas , Neoplasias Pancreáticas/patologia , Idoso , Biópsia por Agulha Fina/efeitos adversos , Biópsia por Agulha Fina/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Agulhas/efeitos adversos , Estudos Prospectivos
5.
Europace ; 11(12): 1647-53, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19752011

RESUMO

AIMS: This retrospective analysis sought to develop and validate a model using the measured diagnostic variables in cardiac resynchronization therapy (CRT) devices to predict mortality. METHODS AND RESULTS: Data used in this analysis came from two CRT studies: Cardiac Resynchronization Therapy Registry Evaluating Patient Response with RENEWAL Family Devices (CRT RENEWAL) (n = 436) and Heart Failure-Heart Rate Variability (HF-HRV) (n = 838). Patients from CRT RENEWAL were used to create a model for risk of death using logistic regression and to create a scoring system that could be used to predict mortality. Results of both the logistic regression and the clinical risk score were validated in a cohort of patients from the HF-HRV study. Diagnostics significantly improved over time post-CRT implant (all P < 0.001) and were correlated with a trend of decreased risk of death. The regression model classified CRT RENEWAL patients into low (2.8%), moderate (6.9%), and high (13.8%) risk of death based on tertiles of their model predicted risk. The clinical risk score classified CRT RENEWAL patients into low (2.8%), moderate (10.1%), and high (13.4%) risk of death based on tertiles of their score. When both the regression model and the clinical risk score were applied to the HF-HRV study, each was able to classify patients into appropriate levels of risk. CONCLUSION: Device diagnostics may be used to create models that predict the risk of death.


Assuntos
Estimulação Cardíaca Artificial/mortalidade , Sistemas de Apoio a Decisões Clínicas , Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Modelos de Riscos Proporcionais , Análise de Sobrevida , Idoso , Feminino , Humanos , Incidência , Masculino , Prognóstico , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos
6.
Indian Pacing Electrophysiol J ; 9(4): 224-8, 2009 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-19652735

RESUMO

Inadvertent lead placement in the left ventricle (LV) is an uncommon and often under-diagnosed complication of cardiac device implantation. Thromboembolic (TE) events are common and usually secondary to fibrosis or thrombus formation on or around the lead. Anticoagulation can prevent TE events. Percutaneous and surgical LV lead extractions have been performed successfully, but the risks of percutaneous lead removal are not well-defined. In this report, we describe a case of inadvertent LV lead placement and briefly review the contemporary literature.

7.
Crit Pathw Cardiol ; 16(2): 71-75, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28509707

RESUMO

BACKGROUND: Impairments in psychosocial status and cognition relate to poor clinical outcomes in patients with atrial fibrillation (AF). However, how often these conditions co-occur and associations between burden of psychosocial and cognitive impairment and quality of life (QoL) have not been systematically examined in patients with AF. METHODS: A total of 218 patients with symptomatic AF were enrolled in a prospective study of AF and psychosocial factors between May 2013 and October 2014 at the University of Massachusetts Medical Center. Cognitive function, depression, and anxiety were assessed at baseline and AF-specific QoL was assessed 6 months after enrollment using validated instruments. Demographic and clinical information were obtained from a structured interview and medical record review. RESULTS: The mean age of the study participants was 63.5 ± 10.2 years, 35% were male, and 81% had paroxysmal AF. Prevalences of impairment in 1, 2, and 3 psychosocial/cognitive domains (eg, depression, anxiety, or cognition) were 75 (34.4%), 51 (23.4%), and 16 (7.3%), respectively. Patients with co-occurring psychosocial/cognitive impairments (eg, >1 domain) were older, more likely to smoke, had less education, and were more likely to have heart failure (all P < 0.05). Compared with participants with no psychosocial/cognitive impairments, AF-specific QoL at 6 months was significantly poorer among participants with baseline impairment in 2 (B = -13.6, 95% CI: -21.7 to -5.4) or 3 (B = -15.1, 95% CI: -28.0 to -2.2) psychosocial/cognitive domains. CONCLUSION: Depression, anxiety, and impaired cognition were common in our cohort of patients with symptomatic AF and often co-occurred. Higher burden of psychosocial/cognitive impairment was associated with poorer AF-specific QoL.


Assuntos
Fibrilação Atrial/complicações , Disfunção Cognitiva/economia , Efeitos Psicossociais da Doença , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/psicologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/psicologia , Feminino , Seguimentos , Humanos , Masculino , Prevalência , Estudos Prospectivos , Índice de Gravidade de Doença , Inquéritos e Questionários , Estados Unidos/epidemiologia
8.
Crit Pathw Cardiol ; 14(4): 157-65, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26569657

RESUMO

INTRODUCTION: Predicting which patients will be free from atrial fibrillation (AF) after pulmonary vein isolation (PVI) remains challenging. Clinical risk prediction scores show modest ability to identify patients at risk for AF recurrence after PVI. B-type natriuretic peptide (BNP) is associated with risk for incident and recurrent AF but is not currently included in existing AF risk scores. We sought to evaluate the incremental benefit of adding preoperative BNP to existing risk scores for predicting AF recurrence during the 6 months after PVI. METHODS: One hundred sixty-one patients with paroxysmal or persistent AF underwent an index PVI procedure between 2010 and 2013; 77 patients (48%) had late AF recurrence after PVI (>3 months post-PVI) over the 6-month follow-up period. RESULTS: A BNP greater than or equal to 100 pg/dL (P=0.01) and AF recurrence within 3 months after PVI (P<0.001) were associated with late AF recurrence in multivariate analyses. Addition of BNP to existing clinical risk scores significantly improved the areas under the curve for each score, with an integrated discrimination improvement of 0.08 (P=0.001) and a net reclassification improvement of 60% (P=0.001) for all risk scores. CONCLUSIONS: Circulating BNP levels are independently associated with late AF recurrence after PVI. Inclusion of BNP significantly improves the discriminative ability of CHADS2, CHA2DS2-VASc, R2CHADS2, and the HATCH score in predicting clinically significant, late AF recurrence after PVI and should be incorporated in decision-making algorithms for management of AF. B-R2CHADS2 is the best score model for prediction of late AF recurrence.


Assuntos
Fibrilação Atrial/cirurgia , Peptídeo Natriurético Encefálico/sangue , Veias Pulmonares/cirurgia , Adulto , Idoso , Fibrilação Atrial/sangue , Ablação por Cateter/métodos , Estudos de Coortes , Criocirurgia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Prognóstico , Recidiva , Medição de Risco , Resultado do Tratamento
9.
Heart Surg Forum ; 6(3): E38-41, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12821436

RESUMO

BACKGROUND: Surgical therapy for atrial fibrillation is extremely effective but not widely applied. Minimally invasive methods may be more attractive. We report a case of complete pulmonary vein isolation performed entirely through a thoracoscopic approach. METHODS: A 74-year-old woman with paroxysmal atrial fibrillation underwent a microwave ablation procedure using 3 access ports in the right pleural space and 3 access ports through the left pleural space. RESULTS: After the 3-hour procedure the patient was extubated in the operating room and discharged home in sinus rhythm on the second postoperative day. CONCLUSIONS: Endoscopic pulmonary vein isolation is a safe and effective procedure that may be applied to a wide variety of patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Micro-Ondas/uso terapêutico , Veias Pulmonares/cirurgia , Idoso , Feminino , Humanos , Toracoscopia/métodos
12.
Pancreas ; 40(5): 680-1, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21602735

RESUMO

BACKGROUND: Endoscopic ultrasound with fine needle aspiration (EUS-FNA) is used for the diagnosis of pancreatic malignancy. However, there are limited data as to patient preferences regarding the delivery of cancer diagnoses. OBJECTIVE: This study aimed to assess if patients had met the endosonographer before their EUS, their suspicion of having cancer, and whether they would like the cytology results given to them by their referring physician (with whom they had a previous relationship) or the endosonographer. This question was also asked with respect to the timing of receiving cytology results. METHODS: A total of 131 patients with a suspected solid pancreatic mass undergoing EUS-FNA at 2 tertiary referral centers were prospectively enrolled and completed a preprocedure questionnaire. RESULTS: One hundred twenty patients (92%) had not met the endosonographer before their EUS-FNA, and only 37 patients (28%) thought they had a pancreatic malignancy. Of the 131 patients, 89 (68%) stated that they wanted to hear results from the endosonographer (P = 0.0001) and 100 patients (76%) chose to hear results as soon as possible from the endosonographer (P = 0.001). CONCLUSIONS: Our data highlight the importance of the endosonographer's role in the delivery of cancer diagnoses and that patients value expediency of reporting results over long-term physician relationships.


Assuntos
Neoplasias Pancreáticas/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Biópsia por Agulha Fina , Comunicação , Endossonografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/diagnóstico por imagem , Preferência do Paciente , Relações Médico-Paciente , Estudos Prospectivos , Encaminhamento e Consulta , Inquéritos e Questionários
14.
Cardiology ; 102(4): 188-93, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15452391

RESUMO

BACKGROUND: Brain natriuretic peptide (BNP) levels have been reported to fall following cardioversion of atrial fibrillation (AF). The mechanism for the fall in BNP has not been elucidated and the potential confounding effects of sedation have not been investigated. Sedation may alter BNP levels via its effects on loading conditions. Accordingly, we studied whether BNP levels change shortly after cardioversion and attempted to control for possible effects of sedation. METHODS: BNP levels were obtained before and after cardioversion in patients with AF and in a control group of patients undergoing intravenous conscious sedation for transesophageal echocardiography. RESULTS: BNP levels dropped (260 +/- 255 vs. 190 +/- 212 pg/ml, p < 0.05) 40 min after cardioversion, decreasing in 33 of 41 subjects who achieved sinus rhythm. By contrast, mean BNP did not fall in subjects in whom cardioversion was not successful. The change in BNP level was not related to the degree of change in heart rate. No control subject experienced a change in cardiac rhythm; BNP levels increased (195 +/- 407 vs. 238 +/- 458 pg/ml, p < 0.05) in 18/22 subjects after sedation. Baseline BNP levels were elevated in subjects with AF, and BNP levels were elevated in parallel with heart failure symptoms. CONCLUSIONS: The rapid fall in BNP after cardioversion (1) may reflect prompt hemodynamic improvement associated with rhythm change and (2) does not appear to be due to the effects of sedation.


Assuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/terapia , Cardioversão Elétrica , Peptídeo Natriurético Encefálico/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Anestésicos Intravenosos/farmacologia , Fibrilação Atrial/fisiopatologia , Estudos de Casos e Controles , Sedação Consciente , Feminino , Fentanila/farmacologia , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Midazolam/farmacologia , Pessoa de Meia-Idade , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa