Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Ophthalmol ; 24(1): 320, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39090592

RESUMO

BACKGROUND: The visual performance and the optical quality of a segmental refractive extended depth-of-focus (EDoF) intraocular lens (IOL) were evaluated in a prospective, single-arm, single-center study. METHODS: A total of 20 patients (40 eyes) after bilateral implantation of the refractive segmental EDoF Acunex Vario AN6V were included. Assessment procedure: refraction outcome, monocular and binocular uncorrected (UCVA) and distance-corrected visual acuity (DCVA), defocus curve, contrast sensitivity (CS), higher-order aberrations (HOAs) and patient satisfaction were evaluated 1 and 3 months after surgery. RESULTS: At 3-month follow-up, mean spherical equivalent was - 0.23 ± 0.32 D. Binocular uncorrected distance visual acuity (VA) at distance, intermediate and near was - 0.08 ± 0.06 logMAR at 4 m, -0.03 ± 0.06 logMAR at 66 cm and 0.16 ± 0.06 logMAR at 40 cm, respectively. The binocular defocus curve showed a VA better than 0.20 logMAR over a range from + 1.50 to - 2.45 D. Contrast sensitivity aligned with monofocal lenses, highlighting the lens's clinical value. Aberrometry showed minimal changes in corneal aberrations. NEI-RQL-42-Questionnaire showed a high patient satisfaction for daily activities and revealed reduced dependence on glasses, particularly for near and intermediate vision. The Acunex Vario AN6V demonstrated minimal dysphotopsias, making it a promising option for those seeking spectacle independence. CONCLUSION: This segmental refractive EDoF IOL provides a high degree of spectacle independence for far and intermediate distances with functional near VA. Although inducing residual coma aberrations, it showed subjectively good results with little dysphotopsias. TRIAL REGISTRATION: This study protocol was reviewed and approved by ethics committee of Charité University, Berlin, Germany, with approval number EA4/126/20.


Assuntos
Sensibilidades de Contraste , Lentes Intraoculares , Satisfação do Paciente , Pseudofacia , Refração Ocular , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Feminino , Estudos Prospectivos , Masculino , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Idoso , Sensibilidades de Contraste/fisiologia , Pseudofacia/fisiopatologia , Desenho de Prótese , Facoemulsificação , Implante de Lente Intraocular/métodos , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Seguimentos
2.
Eur J Ophthalmol ; 33(6): 2096-2105, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36274639

RESUMO

PURPOSE: To analyse higher-order aberrations of an enhanced monofocal aspheric intraocular lens (IOL) in relation to the clinical outcome compared to a monofocal aspheric IOL. SETTING: Department of Ophthalmology, Charité - Universitätsmedizin Berlin, Germany. DESIGN: Prospective, monocentric, controlled, non-randomized, two-armed study. METHODS: After phacoemulsification, a total of 30 patients (60 eyes) were bilaterally implanted with either TECNIS Eyhance IOL model ICB00 (Johnson & Johnson Surgical Vision, Inc.) or TECNIS Monofocal 1-Piece IOL model ZCB00 (Johnson & Johnson Surgical Vision, Inc.) in 30 eyes each. Assessments were performed 1 and 3 months after surgery including refraction, uncorrected and best-corrected distance, intermediate and near visual acuity, defocus curves, contrast sensitivities under photopic, mesopic and mesopic conditions with glare, higher-order aberrations (HOAs) at pupil sizes of 5, 4, 3 and 2 mm and patient satisfaction. RESULTS: At 3-month follow-up, measurements of HOAs revealed significant higher negative internal and ocular primary spherical aberrations in the ICB00 group at pupil sizes of 5, 4, 3 and 2 mm. The ICB00 showed significant better results in intermediate and near visual acuity, but no difference in distance visual acuity. No significant difference was found in contrast sensitivities at any condition or spatial frequency. Spectacle independence was significant better without significant higher rates of dysphotopsia in the ICB00 group. CONCLUSIONS: Higher negative spherical aberrations in the ICB00 group at all measured pupil sizes appear to lead to a superior clinical outcome in intermediate and near vision compared to the ZCB00 group without compromising contrast sensitivity or distance visual acuity.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa