Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Arthroscopy ; 29(6): 972-81, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23571131

RESUMO

PURPOSE: To assess molecular and histologic differences between the proximal (intra-articular) and distal (extra-articular) portions of the long head of the biceps (LHB) tendon in 3 different disease states (biceps instability, tendinosis, and degenerative joint disease [DJD]) compared with a healthy tendon (fresh frozen). METHODS: We used 32 LHB tendons of patients undergoing tenodesis (mean age, 54.7 ± 10.1 years) and 9 harvested tissue donors. Tendons were divided according to 4 diagnostic groups: (1) biceps instability, (2) tendinosis, (3) DJD, and (4) normal control. After sectioning, tendons were fixed in formalin and stained with H&E and alcian blue for histologic analysis. Measurements of collagen organization by use of polarized light microscopy was then performed, and protein expression for type I and type III collagen, tenascin C, and decorin was determined. RESULTS: There were no statistical differences found for protein expression of type I or type III collagen, tenascin C, or decorin. The proximal and distal regions of the tendons had statistically significant differences in alcian blue staining, with the proximal portion containing a higher amount of proteoglycan (instability, P = .001; tendinosis, P = .005; DJD, P = .008; control, P = .011). When compared with the nonpathologic control tendons, a significant increase in alcian blue staining for the proximal region was seen in all 3 groups. Total polarized light analysis showed that the distal tendon had a significantly higher intensity (organization) compared with the proximal tendon (P < .001); this was also seen in all of the diagnostic groups (instability, P = .010; tendinosis, P = .013; DJD, P = .07; control, P = .028). CONCLUSIONS: This study showed a greater degree of degeneration of the proximal (intra-articular) regions of the LHB tendon when compared with the distal regions in all pathologic groups. However, no major differences at the cellular level were found among groups. CLINICAL RELEVANCE: The pathomechanisms of the various forms of known LHB diagnoses are not yet fully understood and basic science studies may help in understanding their etiology and therefore optimizing treatment options.


Assuntos
Artropatias/patologia , Músculo Esquelético/patologia , Articulação do Ombro/patologia , Tendinopatia/patologia , Tendões/patologia , Adulto , Colágeno Tipo I/metabolismo , Colágeno Tipo III/metabolismo , Decorina/metabolismo , Feminino , Humanos , Artropatias/metabolismo , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/metabolismo , Músculo Esquelético/cirurgia , Osteoartrite/metabolismo , Osteoartrite/patologia , Articulação do Ombro/anatomia & histologia , Tenascina/metabolismo , Tendinopatia/metabolismo , Tendões/anatomia & histologia , Tendões/metabolismo , Adulto Jovem
2.
Cureus ; 14(7): e26864, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35974851

RESUMO

Introduction Postoperative infections represent a substantial burden to patients and healthcare systems. To improve patient care and reduce healthcare expenditures, interventions to reduce surgical infections must be employed. The crystalline C-band ultraviolet (UV-C) air filtration technology (Aerobiotix Inc., Miamisburg, OH, USA) has been designed to reduce airborne bioburden through high-quality filtration and germicidal irradiation. The purpose of this study was to assess the ability of a novel UV-C air filtration device to reduce airborne particle counts and contamination of surgical instrument trays in an operating room (OR) setting. Materials and methods Thirty sterile instrument trays were opened in a positive-air-flow OR. The trays were randomly assigned to one of two groups (UV-C or control, n=15 per group). In the UV-C group, the UV-C filtration device was used and in the control, it was not. All trays were opened with the use of a sterile technique and left exposed in the OR for four hours. Air was sampled by a particle counter to measure the numbers of 5µm and 10µm particles. Culture specimens were obtained from the trays to assess for bacterial contamination. Outcome data were collected at 30-minute intervals for the duration of the four-hour study period. Results Use of the UV-C device resulted in statistically significant reductions in the numbers of 5µm (average of 64.9% reduction when compared with the control, p<0.001) and 10µm (average of 65.7% reduction when compared with the control, p<0.001)-sized particles detectable in the OR. There was no significant difference in the overall rates of contamination (33.3% in the control group vs. 26.7% in the UV-C group, p=1.0) or the time to contamination (mean survival of 114 minutes in the control group vs. 105 minutes in the UV-C group, p=0.72) of surgical instrument trays with the use of the UV-C device. Conclusions The results demonstrate that the UV-C filtration device can successfully reduce airborne bioburden in standard ORs, suggesting that it may have the potential to reduce the risk for wound and hardware infections. Further clinical trials are necessary to better determine the effect of this air filtration system on postoperative infection rates.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa