Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Dis Esophagus ; 30(7): 1-7, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29206905

RESUMO

It is unknown if successful control of esophageal inflammation in eosinophilic esophagitis (EoE) decreases the need for subsequent esophageal dilation. We aimed to determine whether histologic response to topical steroid treatment decreases the likelihood and frequency of subsequent esophageal dilation. We conducted a retrospective cohort study. Patients with an incident diagnosis of EoE were included if they had an initial esophageal dilation, received topical steroids, and had a subsequent endoscopy with biopsies. The number of dilations performed in each group was determined, and histologic responders (<15 eos/hpf) were compared to nonresponders. The 55 EoE patients included (27 responders and 28 nonresponders) underwent a mean of 3.0 dilations over a median follow-up of 19 months. Responders required fewer dilations than nonresponders (1.6 vs. 4.6, P = 0.03), after adjusting for potential confounders. Despite undergoing significantly fewer dilations, responders achieved a similar increase in esophageal diameter with dilation (4.9 vs. 5.0 mm; P = 0.92). In EoE patients undergoing esophageal dilation at baseline, control of inflammation with topical steroids was associated with a 65% decrease in the number of subsequent dilations to maintain the same esophageal caliber. This suggests that inflammation control is an important goal in patients with fibrostenotic changes of EoE.


Assuntos
Anti-Inflamatórios/uso terapêutico , Esofagite Eosinofílica/tratamento farmacológico , Esofagite Eosinofílica/patologia , Estenose Esofágica/terapia , Administração Tópica , Adulto , Anti-Inflamatórios/administração & dosagem , Biópsia , Budesonida/uso terapêutico , Dilatação , Esofagite Eosinofílica/complicações , Estenose Esofágica/etiologia , Esôfago/patologia , Feminino , Fluticasona/uso terapêutico , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
2.
Ann Thorac Surg ; 63(5): 1243-50, 1997 May.
Artigo em Inglês | MEDLINE | ID: mdl-9146309

RESUMO

BACKGROUND: Pulsatile perfusion systems have been proposed as a means of improving end-organ perfusion during and after cardiopulmonary bypass. Few attempts have been made to study this issue in an infant model. METHODS: Neonatal piglets were subjected to nonpulsatile (n = 6) or pulsatile (n = 7) cardiopulmonary bypass and 60 minutes of circulatory arrest. Cerebral, renal, and myocardial blood flow measurements were obtained at baseline, on bypass before and after circulatory arrest, and after bypass. RESULTS: Cerebral blood flow did not differ between groups at any time and was diminished equally in both groups after circulatory arrest. Renal blood flow was diminished in both groups during bypass but was significantly better in the pulsatile group than in the nonpulsatile group prior to, but not after, circulatory arrest. Myocardial blood flow was maintained at or above baseline in the pulsatile group throughout the study, but in the nonpulsatile group, it was significantly lower than baseline during CPB prior to circulatory arrest and lower compared with baseline and with the pulsatile group 60 minutes after CPB. CONCLUSIONS: Pulsatile bypass does not improve recovery of cerebral blood flow after circulatory arrest, may improve renal perfusion during bypass but does not improve its recovery after ischemia, and may have beneficial effects on myocardial blood flow during bypass and after ischemia compared with nonpulsatile bypass in this infant model.


Assuntos
Encéfalo/irrigação sanguínea , Ponte Cardiopulmonar/métodos , Vasos Coronários/fisiologia , Parada Cardíaca Induzida , Rim/irrigação sanguínea , Fluxo Pulsátil , Animais , Animais Recém-Nascidos , Modelos Animais de Doenças , Isquemia/fisiopatologia , Fluxo Sanguíneo Regional , Suínos
3.
J Invest Surg ; 2(3): 269-79, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2487256

RESUMO

Currently two pumps are used for cardiopulmonary bypass, the roller pump and the centrifugal or vortex pump. Both are steady-flow pumps. The procedure of cardiopulmonary bypass possesses a finite morbidity and mortality. The degree to which steady flow is responsible for this morbidity and mortality remains to be clarified, but investigators have established the fact that a physiologic degree of pulsatile flow must be achieved before its beneficial results, such as normal systemic resistance and absence of lactate production, can be demonstrated. Availability of a satisfactory pulsatile pump for cardiopulmonary bypass has been a problem in the past but the pump presented here may satisfy this need. It produces physiologic pulsatility with rate dependent ejection time equal to or less than that of humans (413 microseconds minus 1.7 times heart rate), and it is preload-responsive, varying its pumping rate and output with filling pressure. The pump is externally valved to minimize hemolysis, which has been demonstrated in two laboratory studies to be significantly less than with the roller pump. It produces pulsatile flow through membrane oxygenators. The pump is thought to have potential for several clinical applications in addition to (1) pulsatile-flow cardiopulmonary bypass, including (2) left, right, or combined transthoracic QRS synchronized ventricular assist, (3) femoral vein to femoral artery QRS synchronized left ventricular assist, (4) adult or infant ECMO, (5) pulsatile flow hemodialysis. In the latter, spallation and embolization of hemodialysis tubing particles should not be a problem as has proved to be the case with the present hemodialysis pump.


Assuntos
Ponte Cardiopulmonar/instrumentação , Coração Auxiliar , Humanos
4.
ASAIO J ; 40(3): M344-50, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-8555537

RESUMO

Eight adult goats under went 5 hr of normothermic cardiopulmonary bypass (CPB) with pulsatile (n = 3) and nonpulsatile flow (n = 5). PaCO2 was maintained at 30-40 mmHg and blood flow rate at 50 ml/min/kg. Brain tissue pH, PO2, and PCO2, arterial and venous blood gases, and other systemic variables were monitored. No significant differences in brain electrochemistry between pulsatile and nonpulsatile perfusion were observed owing to the large variability of the results and the small number of experiments. The overall data for brain tissue pH, PO2, and PCO2 were analyzed and compared to the results of arterial and venous pH, PO2, and PCO2. Brain acidosis developed at the onset of bypass, and the values for brain tissue pH dissociated from those of blood pH, suggesting that hemodilution and the initial body response to CPB are involved in its development. Brain hypercapnia also developed during CPB, the values of brain tissue PCO2 dissociated from those of blood PCO2, and brain hypercapnia appears to be secondary to brain acidosis. Brain tissue PO2 closely followed the values of PvO2, suggesting that PvO2 can be an indicator of brain tissue PO2 during normothermic CPB and must be monitored during the procedure. Brain tissue acidosis is evidently related to neurologic dysfunction after CPB, and must be addressed. Replacement of the priming solution with whole blood or artificial blood, reduction of the priming volume, and application of vigorous pulsatile flow appear feasible interventions to mitigate brain tissue acidosis during CPB.


Assuntos
Encéfalo/metabolismo , Dióxido de Carbono/sangue , Dióxido de Carbono/metabolismo , Ponte Cardiopulmonar/efeitos adversos , Oxigênio/sangue , Oxigênio/metabolismo , Acidose/etiologia , Acidose/metabolismo , Acidose/prevenção & controle , Animais , Lesões Encefálicas/etiologia , Lesões Encefálicas/metabolismo , Ponte Cardiopulmonar/instrumentação , Ponte Cardiopulmonar/métodos , Cabras , Concentração de Íons de Hidrogênio , Hipercapnia/etiologia , Hipercapnia/metabolismo , Hipercapnia/prevenção & controle , Fluxo Pulsátil , Fatores de Tempo
5.
ASAIO J ; 42(5): M796-9, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8944993

RESUMO

An extracorporeal pulsatile heart pump has been modified to render biventricular cardiac support while maintaining automatic volume balance between the left and right sides. The device consists of two independent fluid circuits, externally valved and compressed by a common pusher plate configuration. Because the pusher plate compresses both circuits simultaneously, the volume-heavy side is unloaded via larger stroke volumes until the two sides achieve a balanced stroke volume. The process is automatic from beat-to-beat and is not dependent upon external pressure or flow transducers to maintain equilibrium. Two in vivo studies in pigs weighing 25 kg have demonstrated the feasibility of the concept, with physiologic aortic and pulmonary artery flow during 2 hr of ac-induced ventricular fibrillation and oscillatory ventilator support via left atrium-to-aorta and right atrium-to-pulmonary artery cannulation. Efforts to scale up to human adult size requirements have resulted in in vitro outputs of up to 7.0 L/min in each circuit.


Assuntos
Coração Auxiliar , Respiração , Adulto , Animais , Engenharia Biomédica , Dióxido de Carbono/sangue , Desenho de Equipamento , Estudos de Avaliação como Assunto , Coração Auxiliar/efeitos adversos , Humanos , Oxigênio/sangue , Circulação Pulmonar , Volume Sistólico , Suínos
6.
ASAIO J ; 43(5): M482-6, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9360089

RESUMO

The effectiveness of an infant pulsatile cardiopulmonary bypass (CPB) system on maintaining regional cerebral blood flow (CBF) using two different types of aortic cannulae in 3 kg piglets has been investigated. The University of Texas Neonatal Pulsatile Pump was used with either a DLP (Group I, n = 6) or an Elecath (Group II, n = 7) 10Fr aortic cannula. In all the subjects, nasopharyngeal temperature was reduced to 18 degrees C, followed by 1 hr of deep hypothermic circulatory arrest (DHCA), then 45 min of rewarming. During cooling and rewarming, alpha-stat blood gas management was used. The radionuclide labeled microsphere technique was used to determine blood flows in the cerebellum, basal ganglia, brainstem, right and left hemispheres, as well as global CBF (ml/100 g/min). When the DLP aortic cannula was used, regional and global CBF appeared to be higher pre- and post DHCA. In both groups regional CBF was significantly decreased following DHCA. Although better pulsatile flow was attained using the DLP cannula and this may have resulted in higher regional CBF, these results must be interpreted in light of the large standard deviations noted when this cannula was chosen for the studies. These results demonstrate the importance of choosing an appropriate aortic cannula for measuring regional CBF with a pulsatile neonate-infant CPB system.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Cateterismo/instrumentação , Circulação Cerebrovascular , Animais , Animais Recém-Nascidos , Aorta , Gânglios da Base/irrigação sanguínea , Lesões Encefálicas/diagnóstico , Lesões Encefálicas/etiologia , Lesões Encefálicas/fisiopatologia , Tronco Encefálico/irrigação sanguínea , Cateterismo/efeitos adversos , Cerebelo/irrigação sanguínea , Humanos , Lactente , Recém-Nascido , Microesferas , Modelos Biológicos , Fluxo Sanguíneo Regional , Suínos
7.
ASAIO J ; 38(3): M726-9, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1457958

RESUMO

In 1990, the NIH formally recognized the need for investigation of the problem of damaging the effects of cardiopulmonary bypass, issuing RFA HL-90-12-H, which emphasized production of neurologic defects in the very young and the elderly. The authors were at that time involved in comparison of pulsatile flow to steady flow cardiopulmonary bypass in large ungulates. The world literature recognizes five damaging effects of steady flow cardiopulmonary bypass that can be mitigated by pulsatile flow: metabolic acidosis, interstitial fluid accumulation, elevated systemic vascular resistance, arteriovenous shunting, and impaired brain oxygenation. To maximize the beneficial effect of pulsatile flow, however, it is necessary that its morphology be physiologic. It has been stated in the past that this goal may not be possible using standard size aortic cannulas. The purpose of this publication is to describe a method by which this feat has been achieved in 150 pound ungulates undergoing prolonged cardiopulmonary bypass.


Assuntos
Cateterismo Cardíaco/instrumentação , Ponte Cardiopulmonar/instrumentação , Animais , Ponte Cardiopulmonar/efeitos adversos , Estudos de Avaliação como Assunto , Feminino , Cabras , Hemodinâmica/fisiologia , Fluxo Pulsátil/fisiologia , Traumatismos do Sistema Nervoso
8.
ASAIO J ; 42(5): M580-3, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8944947

RESUMO

The authors have designed an alternative infant cardiopulmonary bypass (CPB) system using the University of Texas neonatal pulsatile pump, which produces physiologic pulsatile flow and allows a low priming volume. This system has been tested with normothermic CPB (n = 8), and deep hypothermic circulatory arrest (n = 14) in 3 kg piglets. Data obtained during these studies suggest that this system can produce flow characteristics that approximate normal physiologic values. Unlike other pulsatile pumps, this pump can produce a very small stroke volume, ranging from 0.5 to 7.1 ml with a pump rate of 120 beats/min. These stroke volumes correspond to our target value of 1 ml/kg body weight. This system is designed to cause minimal hemodilution and minimal exposure of blood to foreign surface areas. The pump does not produce negative pressure, and therefore the venous reservoir is not essential, and only a cardiotomy reservoir is required. Conclusions after in vivo testing are, first, that physiologic pulsatile flow can be achieved readily with this system using a 10 Fr aortic cannula in 3 kg piglets; and second, that a significant reduction in priming volume and hemodilution can be obtained using this system.


Assuntos
Ponte Cardiopulmonar/instrumentação , Animais , Pressão Sanguínea , Volume Sanguíneo , Desenho de Equipamento , Estudos de Avaliação como Assunto , Hemodiluição , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Oxigenadores de Membrana , Fluxo Pulsátil , Volume Sistólico , Suínos
9.
ASAIO J ; 43(1): 13-8, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9116347

RESUMO

Eleven goats (mean weight, 69 +/- 16 kg) underwent 5 hrs of normothermic nonpulsatile cardiopulmonary bypass (CPB) using as priming fluid either a Ringer's based crystalloid priming solution (CP, n = 5) of a hyperosmolar oxyreplete hemosubstitute (HS, n = 6). The HS contained 20% w/v perfluorocarbon (perfluorodecalin), its osmolarity was 800-900 mOsm/1, and the administered dose of perfluorocarbon was 30-50 ml/kg. Otherwise, the experimental procedure was identical for both groups. PaCO2 was maintained above 35 mmHg and blood flow rate at 65 ml/kg. Brain tissue pH, PO2, and PCO2, cerebral blood flow (CBF), arterial and venous blood gases, and other systemic variables were monitored. During CPB, PVO2 and brain tissue PO2 were increased significantly in the HS group. The CBF per kilogram of weight also was significantly higher in the HS group. Metabolic acidosis developed in both groups and, surprisingly, brain tissue pH and pHV were lower in the HS group. The mean values of PVCO2 and brain tissue PCO2 indicate that brain tissue hypercapnia also occurred in both groups. The HS provided long-term stability and compatibility with electrolytes, and did not cause major complications or allergic reactions during CPB. Perfluorocarbon based HSs improve tissue oxygenation, eliminate the risk of infection due to homologous transfusions, do not require blood type matching, have a shelf life longer than that of blood, and, therefore, they can be an important factor in diminishing the incidence of complications after CPB.


Assuntos
Substitutos Sanguíneos/farmacologia , Encéfalo/metabolismo , Dióxido de Carbono/sangue , Ponte Cardiopulmonar , Circulação Cerebrovascular/efeitos dos fármacos , Fluorocarbonos/farmacologia , Oxigênio/sangue , Animais , Cabras , Concentração de Íons de Hidrogênio
10.
Int J Artif Organs ; 15(4): 222-8, 1992 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1587644

RESUMO

The roller pump is the most common pumping device used in extracorporeal circulation (ECC). The interaction between the roller and tubing causes tubing spallation. Spallation has been associated with complications in ECC. Previous spallation studies present mixed results, including a decrease in the number of circulating particles. The objective of this work is to perform an in vitro study of tubing spallation which elucidates the causes of the particle sequestration, and the effect of tubing material, blood flow rate and duration of the procedure upon spallation. A sampling method minimizing background counts was devised. Silicone and PVC tubing were tested under normal and tight occlusion pressure at typical cardiopulmonary bypass and hemodialysis flow rates, for circulating times up to 4 h. Occlusion pressure and flow rate highly influenced the amount of spallation produced. Particle sequestration was noted and aggregation of the plastic particles was demonstrated. We conclude that, at least in vitro, aggregation causes the decrease in the particle counts and the misleading results obtained in most spallation studies using a Coulter counter.


Assuntos
Materiais Biocompatíveis , Ponte Cardiopulmonar/instrumentação , Circulação Extracorpórea/instrumentação , Diálise Renal/instrumentação , Técnicas In Vitro , Tamanho da Partícula , Cloreto de Polivinila , Elastômeros de Silicone , Fatores de Tempo
11.
Int J Artif Organs ; 16(9): 645-52, 1993 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-8294156

RESUMO

We describe several in vitro experiments showing evidence that pulsatile flow hemodialysis enhances ultrafiltration volume and molecular clearance as compared with steady flow hemodialysis. A new pulsatile pump and a conventional roller pump were compared using different hollow fiber dialyzers and a simulated blood solution containing urea, aspartame and vitamin B-12 at different flow rates and configurations. Ultrafiltration volume and concentration of urea, aspartame and B-12 were measured and molecular clearance (K) calculated. Ultrafiltration volume markedly increased with pulsatile flow. After 10 min K for urea with pulsatile flow was higher in all experiments even when ultrafiltration was prevented. Clearance of aspartame and B-12 also increased with pulsatile flow. We propose three mechanisms by which pulsatile flow is more efficient than steady flow hemodialysis: greater fluid energy, avoidance of molecular channeling and avoidance of membrane layering. We hypothesize that using pulsatile flow in hemodialysis can significantly shorten the duration of dialysis sessions for most of the patients, and consequently reduce the duration of the procedure and its cost.


Assuntos
Diálise Renal , Ureia/metabolismo , Aspartame/metabolismo , Análise Custo-Benefício , Soluções para Hemodiálise/química , Técnicas In Vitro , Cinética , Fluxo Pulsátil , Diálise Renal/instrumentação , Ultrafiltração , Vitamina B 12/metabolismo
12.
Int J Artif Organs ; 19(3): 170-6, 1996 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-8675361

RESUMO

Cardiopulmonary bypass surgical techniques that allow a surgeon to operate on the infant's heart use an extracorporeal circuit consisting of a pump, oxygenator, arterial and venous reservoirs, cannulae, an arterial filter, and tubing. The extracorporeal technique currently used in infants and neonates is sometimes associated with neurologic damage. We are developing a modified cardiopulmonary bypass system for neonates that has been tested in vitro and in one animal in vivo. Unlike other extracorporeal circuits which use steady flow, this system utilizes pulsatile flow, a low prime volume (500 ml) and a closed circuit. During in vitro experiments, the pseudo patient's mean arterial pressure was kept constant at 40 mmHg and the extracorporeal circuit pressure did not exceed a mean pressure of 200 mmHg. In our single in vivo experiment, the primary objective was to determine whether physiologic pulsatility with a 10 F (3.3 mm) aortic cannula could be achieved. The results suggest that this is possible.


Assuntos
Ponte Cardiopulmonar , Fluxo Pulsátil/fisiologia , Animais , Desenho de Equipamento , Circulação Extracorpórea/efeitos adversos , Humanos , Técnicas In Vitro , Lactente , Recém-Nascido , Membranas Artificiais , Consumo de Oxigênio/fisiologia , Oxigenadores de Membrana/normas , Cloreto de Polivinila
16.
17.
Tex Med ; 66(1): 61-4, 1970 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-5412216
18.
Am Heart J ; 93(2): 248-55, 1977 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-835469

RESUMO

The principal effects of cardiac glycosides probably can be classified as parasympathomimetic or sympathomimetic. Data from animals and from man suggest that polar cardiac glycosides, such as ouabain and digoxin, possess greater parasympathomimetic (vagal) cardiac effect for a given amount of sympathomimetic (positive inotropic) cardiac effect than do less polar cardiac glycosides, such as digitoxin. Polar glycosides therefore offer some advantage in uncomplicated paroxysmal atrial tachycardia and in uncomplicated atrial flutter and atrial fibrillation when the principal desired effect is reduction in the number of atrial impulses reaching the ventricles or conversion to normal sinus rhythm. Non-polar glycosides offer an advantage when positive inotropicity is desired but when there is some degree of atrioventricular block or when inappropriate sinus bradycardia or anorexia, nausea, or vomiting are present. Ecotopic impulse formation when due to cardiac glycosides is a toxic manifestation of excessive sympathomimetic effect, but is aggravated by vagal-induced sinus bradycardia, so that both parasympathomimetic and sympathomimetic capability of cardiac glycosides must be considered when dealing with myocardial electrical instability.


Assuntos
Glicosídeos Cardíacos/farmacologia , Animais , Anorexia/induzido quimicamente , Arritmia Sinusal/induzido quimicamente , Arritmia Sinusal/tratamento farmacológico , Fibrilação Atrial/tratamento farmacológico , Flutter Atrial/tratamento farmacológico , Atropina/uso terapêutico , Fármacos do Sistema Nervoso Autônomo/farmacologia , Bradicardia/induzido quimicamente , Bradicardia/tratamento farmacológico , Glicosídeos Cardíacos/efeitos adversos , Glicosídeos Cardíacos/classificação , Glicosídeos Cardíacos/uso terapêutico , Parada Cardíaca/induzido quimicamente , Bloqueio Cardíaco/induzido quimicamente , Humanos , Contração Miocárdica/efeitos dos fármacos , Náusea/induzido quimicamente , Parassimpatomiméticos/farmacologia , Nó Sinoatrial/efeitos dos fármacos , Estimulação Química , Simpatomiméticos/farmacologia , Taquicardia Paroxística/tratamento farmacológico , Vômito/induzido quimicamente
19.
Arch Int Pharmacodyn Ther ; 280(2): 194-204, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3718085

RESUMO

Six trained domestic cats received a spectrum of polar to nonpolar cardiac glycosides: ouabain, digoxin or digitoxin with medication free intervals of four weeks. Significant (P less than 0.01) rate reduction (-19 +/- 8%) and prolongation of PR interval (+13 +/- 5%) occurred with ouabain and with digoxin (-18 +/- 5% and +13 +/- 3%) but not with digitoxin (-6 +/- 4% and +6 +/- 5%). However, rate corrected QS2 abbreviation was greater with digitoxin (-13 +/- 3%) than with ouabain (-8 +/- 3%) or digoxin (-10 +/- 5%). The findings indicate that in cats the polar cardiac glycosides ouabain and digoxin produce greater prolongation of A-V conduction while the nonpolar glycoside digitoxin produces greater abbreviation of QS2. Previously this finding was reported by the authors in guinea-pigs and in rabbits and has since been reported in intact rats, dogs, and in man by other authors. Investigators using nonintact subjects have not been able to demonstrate the finding. The differences may have clinical significance and suggest new insight into structural/activity relationships within the cardiac glycoside family.


Assuntos
Bloqueio Cardíaco/induzido quimicamente , Frequência Cardíaca/efeitos dos fármacos , Animais , Atropina/farmacologia , Gatos , Dieta , Digitoxina , Digoxina , Eletrocardiografia , Feminino , Bloqueio Cardíaco/fisiopatologia , Masculino , Ouabaína , Fatores de Tempo
20.
Artif Organs ; 15(1): 35-41, 1991 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-1998489

RESUMO

A unique preload responsive pulsatile pump was compared to a centrifugal pump in total cardiac support in 25-kg canines (n = 6, each group) in the left atrial-to-aorta mode during 5 h of ventricular fibrillation. With steady flow, there was immediate drop in output from 2.1 +/- 1.0 L/min to 1.4 +/- 0.3 L/min, followed by further reduction to 0.9 +/- 0.2 L/min during 5 h of ventricular fibrillation. With a pulsatile pump, there was no significant reduction from control of 2.4 +/- 0.6 L/min and no decline during 5 h of ventricular fibrillation. With steady flow, systemic vascular resistance (SVR) rose significantly from 1,762 dyne-s-cm-5 immediately on pump to 3,013 dyne-s-cm-5 at 5 h. With physiologic pulsatile flow, significant elevation of SVR did not occur. When stressed, due to diminished left atrial return, the centrifugal pump displayed line chatter and streaks of microbubbles, whereas the pulsatile pump did not. Crystalloid volume replacement with the centrifugal pump was 6.5 +/- 1.9 L, and with the preload responsive pulsatile pump, 5.6 +/- 1.3 L. It is concluded that in the left atrial-to-aorta mode during 5 h of ventricular fibrillation and with comparable volume replacement, total cardiac support of canines is associated with lower SVR with physiologic pulsatile flow and is not accompanied by line chatter and cavitation with this preload responsive pump.


Assuntos
Circulação Extracorpórea/instrumentação , Animais , Aorta Torácica , Cães , Átrios do Coração , Fluxo Pulsátil , Fibrilação Ventricular/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa