Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Radiologia ; 57(4): 303-13, 2015.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-25747807

RESUMO

Hyperpolarized (HP) gases are a new class of contrast agents that permit to obtain high temporal and spatial resolution magnetic resonance images (MRI) of the lung airspaces. HP gas MRI has become important research tool not only for morphological and functional evaluation of normal pulmonary physiology but also for regional quantification of pathologic changes occurring in several lung diseases. The purpose of this work is to provide an introduction to MRI using HP noble gases, describing both the basic principles of the technique and the new information about lung disease provided by clinical studies with this method. The applications of the technique in normal subjects, smoking related lung disease, asthma, and cystic fibrosis are reviewed.


Assuntos
Meios de Contraste , Hélio , Pneumopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Xenônio , Humanos
2.
Artigo em Inglês | MEDLINE | ID: mdl-20354575

RESUMO

We describe a prototype system built to allow open-access very-low-field MRI of human lungs using laser-polarized (3)He gas. The system employs an open four-coil electromagnet with an operational B(0) field of 4 mT, and planar gradient coils that generate gradient fields up to 0.18 G/cm in the x and y direction and 0.41 G/cm in the z direction. This system was used to obtain (1)H and (3)He phantom images and supine and upright (3)He images of human lungs. We include discussion on challenges unique to imaging at 50 -200 kHz, including noise filtering and compensation for narrow-bandwidth coils.

3.
Phys Rev Lett ; 96(5): 053002, 2006 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-16486926

RESUMO

We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe. Low xenon concentrations in the flowing gas mixture allow the laser to maintain high Rb polarization. The large spin-exchange rate between Rb and 129Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. We report a maximum polarization of 64% achieved for a 0.3 l/h Xe flow rate, and maximum magnetization output of 6 l/h at 22% polarization. Our findings regarding the polarization dependence on temperature, nitrogen partial pressure, and gas mixture flow velocity are also reported.


Assuntos
Lasers , Isótopos de Xenônio/química , Hélio/química , Nitrogênio/química , Rubídio/química
4.
Opt Lett ; 30(11): 1342-4, 2005 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-15981527

RESUMO

We describe an effective external cavity for narrowing the spectral linewidth of a multiarray stack of laser diode arrays. For a commercially available 279-W free-running five-array laser diode array operating at 60 A, we narrow the spectral linewidth to 0.40 nm at FWHM with 115 W of cw power output. This technique leads to the possibility of higher-efficiency, lower-cost production of hyperpolarized noble gases for magnetic resonance imaging.

5.
Magn Reson Med ; 53(4): 745-9, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15799045

RESUMO

The human lung and its functions are extremely sensitive to gravity; however, the conventional high-field magnets used for most laser-polarized (3)He MRI of the human lung restrict subjects to lying horizontally. Imaging of human lungs using inhaled laser-polarized (3)He gas is demonstrated in an open-access very-low-magnetic-field (<5 mT) MRI instrument. This prototype device employs a simple, low-cost electromagnet, with an open geometry that allows variation of the orientation of the imaging subject in a two-dimensional plane. As a demonstration, two-dimensional lung images were acquired with 4-mm in-plane resolution from a subject in two orientations: lying supine and sitting in a vertical position with one arm raised. Experience with this prototype device will guide optimization of a second-generation very-low-field imager to enable studies of human pulmonary physiology as a function of subject orientation.


Assuntos
Hélio , Isótopos , Pulmão/anatomia & histologia , Imageamento por Ressonância Magnética/instrumentação , Administração por Inalação , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Postura
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa