Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Revasc Med ; 63: 43-51, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38267286

RESUMO

OBJECTIVES: The highest rate of embolization during carotid artery stenting occurs during post-dilation. We evaluated the ability of the Paladin system (Contego Medical, Raleigh, NC), a novel PTA balloon with an integrated 40-É¥m pore filter, to collect microemboli that may pass into the cerebral circulation when used during post-dilation. METHODS: 25 symptomatic patients underwent transradial CAS using the Paladin system in conjunction with the Roadsaver (Terumo Corporation, Tokyo, Japan) micromesh stent. No additional embolic protection was used. The Paladin filters were collected following the procedure and preserved in formalin for histological analysis. The contents were evaluated for particle count and size. Subjects were followed for 30 days and evaluated for major cardiac adverse events (death, stroke and MI). Secondary endpoints included procedure success, device success, access site complications according to EASY score classification, major vascular or ischemic complications at follow up and in-stent restenosis rate evaluated with duplex ultrasound. RESULTS: Mean age of patients was 68,5 years. Type 2 aortic arch was present in 77 % of patients and type 1 and type 3 in 12 % and 11 % of patients respectively. Procedural and device success was obtained in all cases without complications. The 30-day MAE rate was 0 %. Twenty-three filters underwent histological analysis. Microscopic debris was present in 100 % of filters, and 75 % of particles were less than 100É¥m in size. The mean number of particles per filter was 3352 ± 1567 (IQR 4300-2343), and the mean number of particles between 40-100É¥m per filter was 2499 ± 1240 (IQR 3227-1575). CONCLUSION: CAS through radial approach can be safely and effectively performed using the IEP technology Paladin device and double-layer micromesh Roadsaver stent. This strategy can simplify the procedure and decrease peri-procedural complications and procedural time.


Assuntos
Angioplastia com Balão , Estenose das Carótidas , Dispositivos de Proteção Embólica , Desenho de Prótese , Artéria Radial , Stents , Humanos , Idoso , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Fatores de Tempo , Artéria Radial/diagnóstico por imagem , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Estenose das Carótidas/terapia , Estenose das Carótidas/diagnóstico por imagem , Fatores de Risco , Porosidade , Embolia Intracraniana/prevenção & controle , Embolia Intracraniana/etiologia , Idoso de 80 Anos ou mais
2.
Am J Cardiol ; 227: 83-90, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39019203

RESUMO

This study aimed to report the 5-year outcomes from the ILLUMENATE Pivotal randomized controlled trial of the lower dose (2 µg/mm2) Stellarex drug-coated balloon (DCB) (Philips, formerly Spectranetics Corp, Colorado Springs, Colorado) compared with percutaneous transluminal angioplasty (PTA) for the treatment of symptomatic peripheral arterial disease. Long-term safety and effectiveness data for DCBs remains limited. The ILLUMENATE Pivotal was a prospective, randomized, multi-center, single-blinded study. Patients (Rutherford Clinical Category 2 to 4) were randomized 2:1 to Stellarex DCB or PTA. Follow-up was through 60 months. In total, 300 patients were enrolled. The mean age was 68.8 ± 10.2 years. At 60 months, freedom from a primary safety event was 69.2% in the Stellarex DCB arm and 68.2% in the PTA arm (log-rank, p = 0.623). The cumulative rate of major adverse events was 41.0% compared with 44.6% (p = 0.597), respectively. Freedom from clinically-driven target lesion revascularization (CD-TLR) was 70.3% in the Stellarex DCB arm compared with 68.2% in the PTA arm (p = 0.505). Time to first CD-TLR was 768.3 ± 478.9 days compared with 613.5 ± 453.4 days, respectively (p = 0.161). Kaplan-Meier estimates of freedom from all-cause mortality were 80.1% in the Stellarex DCB arm and 80.2% in the PTA arm (log-rank, p = 0.980). In conclusion, the 5-year results of the ILLUMENATE Pivotal randomized controlled trial add to the consistent safety data from the broader ILLUMENATE clinical program. These are the first data to report the 5-year safety and efficacy of a lower dose (2 µg/mm2) DCB for the treatment of symptomatic peripheral arterial disease. Clinicaltrials.gov Registration:NCT01858428.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa