Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Diabet Med ; 29(7): e33-40, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22172021

RESUMO

AIMS: Heart rate variability may be used to assess diabetic cardiac autonomic neuropathy. The aim of the present study was to determine the reliability of standard short-term clinical measurements of heart rate variability in patients with Type 2 diabetes. METHODS: In 24 patients with Type 2 diabetes (11 male, age 61 ± 9 years), parameters of heart rate variability in the time domain (standard deviation of RR intervals, coefficient of variation of RR intervals and root mean square of successive RR interval differences) and frequency domain (very low frequency, low frequency, high frequency and total spectral power) were derived from a 5-min electrocardiograph recorded during two laboratory visits separated by 16 ± 8 days. Absolute and relative reliability were assessed by 95% limits of random variation and the intraclass correlation coefficient, respectively. Categorical agreement of classifications of heart rate variability and sample size estimates for clinical trials were calculated. RESULTS: Despite no significant difference in mean heart rate variability between tests, 95% limits of random variation indicated that repeated measurements were between 58% higher/37% lower (most reliable parameter; coefficient of variation of RR intervals) and 443% higher/82% lower (least reliable parameter; very low frequency power) than the first measure. The intraclass correlation coefficient ranged from 0.58 to 0.90 and sample size requirements from 20 to 93 patients per group. Agreement of categories of heart rate variability ranged from 79 to 96%. CONCLUSIONS: Short-term clinical measurements of heart rate variability in patients with Type 2 diabetes are characterized by poor absolute reliability, but substantial to good relative reliability, suggesting greater clinical utility in diagnosis than in sequential follow-up.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Neuropatias Diabéticas/fisiopatologia , Eletrocardiografia/métodos , Frequência Cardíaca , Idoso , Análise de Variância , Interpretação Estatística de Dados , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/complicações , Neuropatias Diabéticas/sangue , Neuropatias Diabéticas/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Diabet Med ; 29(9): e312-20, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22671998

RESUMO

AIMS: Poor prognosis associated with blunted post-exercise heart-rate recovery may reflect autonomic dysfunction. This study sought the accuracy of post-exercise heart-rate recovery in the diagnosis of cardiac autonomic neuropathy, which represents a serious, but often unrecognized complication of Type 2 diabetes. METHODS: Clinical assessment of cardiac autonomic neuropathy and maximal treadmill exercise testing for heart-rate recovery were performed in 135 patients with Type 2 diabetes and negative exercise echocardiograms. Cardiac autonomic neuropathy was defined by abnormalities in ≥ 2 of 7 autonomic function markers, including four cardiac reflex tests and three indices of short-term (5-min) heart-rate variability. Heart-rate recovery was defined at 1-, 2- and 3-min post-exercise. RESULTS: Patients with cardiac autonomic neuropathy (n = 27; 20%) had lower heart-rate recovery at 1-, 2- and 3-min post-exercise (P < 0.01). Heart-rate recovery demonstrated univariate associations with autonomic function markers (r-values 0.20-0.46, P < 0.05). Area under the receiver-operating characteristic curve revealed good diagnostic performance of all heart-rate recovery parameters (range 0.80-0.83, P < 0.001). Optimal cut-offs for heart-rate recovery at 1-, 2- and 3-min post-exercise were ≤ 28 beats/min (sensitivity 93%, specificity 69%), ≤ 50 beats/min (sensitivity 96%, specificity 63%) and ≤ 52 beats/min (sensitivity 70%, specificity 84%), respectively. These criteria predicted cardiac autonomic neuropathy independently of relevant clinical and exercise test information (adjusted odds ratios 7-28, P < 0.05). CONCLUSIONS: Post-exercise heart-rate recovery provides an accurate diagnostic test for cardiac autonomic neuropathy in Type 2 diabetes. The high sensitivity and modest specificity suggests heart-rate recovery may be useful to screen for patients requiring clinical autonomic evaluation.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Cardiomiopatias Diabéticas/diagnóstico , Neuropatias Diabéticas/diagnóstico , Exercício Físico/fisiologia , Frequência Cardíaca/fisiologia , Programas de Rastreamento/métodos , Idoso , Estudos de Coortes , Diabetes Mellitus Tipo 2/complicações , Cardiomiopatias Diabéticas/epidemiologia , Neuropatias Diabéticas/epidemiologia , Eletrocardiografia , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Fatores de Risco , Sensibilidade e Especificidade , Fatores de Tempo
4.
J Clin Endocrinol Metab ; 95(9): 4455-9, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20610595

RESUMO

CONTEXT: Postprandial dysmetabolism is emerging as an important cardiovascular risk factor. Augmentation index (AIx) is a measure of systemic arterial stiffness and independently predicts cardiovascular outcome. OBJECTIVE: The objective of this study was to assess the effect of a standardized high-fat meal on metabolic parameters and AIx in 1) lean, 2) obese nondiabetic, and 3) subjects with type 2 diabetes mellitus (T2DM). DESIGN AND SETTING: Male subjects (lean, n = 8; obese, n = 10; and T2DM, n = 10) were studied for 6 h after a high-fat meal and water control. Glucose, insulin, triglycerides, and AIx (radial applanation tonometry) were measured serially to determine the incremental area under the curve (iAUC). RESULTS: AIx decreased in all three groups after a high-fat meal. A greater overall postprandial reduction in AIx was seen in lean and T2DM compared with obese subjects (iAUC, 2251 +/- 1204, 2764 +/- 1102, and 1187 +/- 429% . min, respectively; P < 0.05). The time to return to baseline AIx was significantly delayed in subjects with T2DM (297 +/- 68 min) compared with lean subjects (161 +/- 88 min; P < 0.05). There was a significant correlation between iAUC AIx and iAUC triglycerides (r = 0.50; P < 0.05). CONCLUSIONS: Obesity is associated with an attenuated overall postprandial decrease in AIx. Subjects with T2DM have a preserved, but significantly prolonged, reduction in AIx after a high-fat meal. The correlation between AIx and triglycerides suggests that postprandial dysmetabolism may impact on vascular dynamics. The markedly different response observed in the obese subjects compared with those with T2DM was unexpected and warrants additional evaluation.


Assuntos
Diabetes Mellitus Tipo 2/fisiopatologia , Dieta Aterogênica , Gorduras na Dieta/farmacologia , Obesidade/fisiopatologia , Resistência Vascular/efeitos dos fármacos , Adulto , Idoso , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/fisiopatologia , Diabetes Mellitus Tipo 2/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Período Pós-Prandial/efeitos dos fármacos , Risco
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa