Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Int Ophthalmol ; 43(1): 285-292, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35870049

RESUMO

PURPOSE: To evaluate the association between postoperative intraocular pressure (IOP) reduction and phacoemulsification parameters in patients who underwent both conventional phacoemulsification surgery (CPS) and femtosecond laser-assisted cataract surgery (FLACS). METHODS: This was a prospective multicenter comparative study that enrolled 90 participants who underwent cataract surgery at the University of Maryland Medical System and the Wilmer Eye Institute. Patients underwent FLACS in one eye and CPS in the fellow eye. IOP was measured prior to surgery and monitored through six months postoperatively. Demographic, clinical, biometric, and intraoperative variables including cumulative dissipated energy (CDE), aspiration time, and phacoemulsification time were analyzed for any significant association with postoperative IOP. Postoperative IOP reduction was the primary outcome variable. A secondary goal of the study was to determine differences in postoperative IOP reduction between CPS and FLACS cohorts. RESULTS: In total, 157 non-glaucomatous eyes were included. Using multivariable analysis, we found preoperative IOP to be consistently associated with postoperative IOP reduction in the entire cohort. At the 6-month follow-up visit, there was a 12.4% reduction in IOP (-2.2 ± 3.4 mm Hg) seen, with no statistically significant difference between FLACS and CPS (12.3% ± 19.4% vs 12.5% ± 19.3%, respectively, p = 0.32). FLACS reduced the CDE required for phacoemulsification (6.6 ± 4.4%-seconds vs 8.6 ± 6.9%-seconds, respectively, p < 0.05). CDE was a predictor of IOP response at 6 months, but subgroup analysis revealed that this trend was driven by seven eyes requiring high CDE, and for the majority of eyes, CDE did not influence the size of the decrease. The seven eyes experiencing highest CDE were less likely to show IOP reduction at 6 months. CONCLUSION: Both FLACS and CPS resulted in similar and significant IOP reductions through 6 months after surgery. Preoperative IOP was significantly associated with IOP reduction, and CDE generally did not influence the size of the decrease.


Assuntos
Extração de Catarata , Catarata , Terapia a Laser , Facoemulsificação , Humanos , Facoemulsificação/métodos , Pressão Intraocular , Estudos Prospectivos , Terapia a Laser/métodos , Acuidade Visual , Extração de Catarata/métodos , Lasers
2.
Eye Contact Lens ; 48(1): 27-32, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34608027

RESUMO

OBJECTIVE: To identify corneal structure differences on quantitative high-frequency ultrasound biomicroscopy (UBM) among subjects with congenital glaucoma compared with controls. METHODS: This prospective case-control study evaluated 180 UBM images from 44 eyes of 30 subjects (18 control and 12 glaucoma, mean age 5.2±8.0 years, range 0.2-25.8 years) enrolled in the Pediatric Anterior Segment Imaging and Innovation Study (PASIIS). ImageJ was used to quantify a comprehensive set of corneal structures according to 21 quantitative parameters. Statistical analysis compared corneal measurements in glaucoma subtypes and age-matched controls with significance testing and mixed effects models. RESULTS: Significant differences between congenital glaucoma cases and controls were identified in 16 of 21 measured parameters including angle-to-angle, central and peripheral corneal thicknesses, scleral integrated pixel density, anterior corneal radius of curvature, and posterior corneal radius of curvature. Eight parameters differed significantly between primary congenital glaucoma and glaucoma following congenital cataract surgery. CONCLUSION: Multiple measurable corneal structural differences exist between congenital glaucoma and control eyes, and between primary and secondary congenital glaucoma, including but not limited to corneal width and thickness. The structural differences can be quantified from UBM image analysis. Further studies are needed to determine whether corneal features associated with glaucoma can be used to diagnose or monitor progression of congenital glaucoma.


Assuntos
Glaucoma , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Córnea/diagnóstico por imagem , Glaucoma/diagnóstico , Humanos , Lactente , Microscopia Acústica , Esclera , Adulto Jovem
3.
Int J Mol Sci ; 23(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35008666

RESUMO

Congenital cataracts (CC) are responsible for approximately one-tenth of childhood blindness cases globally. Here, we report an African American family with a recessively inherited form of CC. The proband demonstrated decreased visual acuity and bilateral cataracts, with nuclear and cortical cataracts in the right and left eye, respectively. Exome sequencing revealed a novel homozygous variant (c.563A > G; p.(Asn188Ser)) in GJA3, which was predicted to be pathogenic by structural analysis. Dominantly inherited variants in GJA3 are known to cause numerous types of cataracts in various populations. Our study represents the second case of recessive GJA3 allele, and the first report in African Americans. These results validate GJA3 as a bona fide gene for recessively inherited CC in humans.


Assuntos
Catarata/congênito , Catarata/genética , Conexinas/química , Conexinas/genética , Mutação de Sentido Incorreto/genética , Sequência de Aminoácidos , Sequência de Bases , Criança , Feminino , Homozigoto , Humanos , Domínios Proteicos
4.
Ophthalmology ; 126(6): 822-828, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30731101

RESUMO

PURPOSE: To determine the agreement of 6 established visual field (VF) progression algorithms in a large dataset of VFs from multiple institutions and to determine predictors of discordance among these algorithms. DESIGN: Retrospective longitudinal cohort study. PARTICIPANTS: Visual fields from 5 major eye care institutions in the United States were analyzed, including a subset of eyes with at least 5 Swedish interactive threshold algorithm standard 24-2 VFs that met our reliability criteria. Of a total of 831 240 VFs, a subset of 90 713 VFs from 13 156 eyes of 8499 patients met the inclusion criteria. METHODS: Six commonly used VF progression algorithms (mean deviation [MD] slope, VF index slope, Advanced Glaucoma Intervention Study, Collaborative Initial Glaucoma Treatment Study, pointwise linear regression, and permutation of pointwise linear regression) were applied to this cohort, and each eye was determined to be stable or progressing using each measure. Agreement between individual algorithms was tested using Cohen's κ coefficient. Bivariate and multivariate analyses were used to determine predictors of discordance (3 algorithms progressing and 3 algorithms stable). MAIN OUTCOME MEASURES: Agreement and discordance between algorithms. RESULTS: Individual algorithms showed poor to moderate agreement with each other when compared directly (κ range, 0.12-0.52). Based on at least 4 algorithms, 11.7% of eyes progressed. Major predictors of discordance or lack of agreement among algorithms were more depressed initial MD (P < 0.01) and older age at first available VF (P < 0.01). A greater number of VFs (P < 0.01), more years of follow-up (P < 0.01), and eye care institution (P = 0.03) also were associated with discordance. CONCLUSIONS: This extremely large comparative series demonstrated that existing algorithms have limited agreement and that agreement varies with clinical parameters, including institution. These issues underscore the challenges to the clinical use and application of progression algorithms and of applying big-data results to individual practices.


Assuntos
Algoritmos , Transtornos da Visão/diagnóstico , Campos Visuais/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Conjuntos de Dados como Assunto , Progressão da Doença , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Transtornos da Visão/fisiopatologia , Testes de Campo Visual/métodos , Adulto Jovem
5.
Int Ophthalmol ; 39(8): 1761-1766, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30054849

RESUMO

PURPOSE: To compare the amount of phacoemulsification ultrasound energy used between eyes undergoing femtosecond laser-assisted cataract surgery (FLACS) and conventional phacoemulsification. METHODS: One eye of consecutive patients undergoing routine non-complicated phacoemulsification from January 2014 to December of 2015 was included in the analysis. FLACS was performed using the Alcon LenSx. Linear regression was used for analysis with type of surgery (FLACS versus conventional phacoemulsification) as the exposure and cumulative dispersed energy (CDE) as the outcome variable. Age, surgeon, eye side, and eye sequence (first versus second eye) were covariates. RESULTS: A total of 1159 surgeries met inclusion criteria. The average age of the cohort was 70.6 (SD 8.6) years, 590 cases (51%) were performed by surgeon 1, and 582 cases (50%) were right eyes. Overall, FLACS resulted in significantly lower CDE as compared to conventional phacoemulsification (ß = 0.89, 95% CI 0.83, 0.95). When stratified by eye side and surgeon, FLACS performed on left eyes operated on by surgeon 1 resulted in lower CDE as compared to conventional phacoemulsification (ß = 0.76, 95% CI 0.66, 0.87), but not for right eyes operated on by surgeon 1 (ß = 0.92, 95% CI 0.79, 1.07) or for eyes operated on by surgeons 2 or 3. CONCLUSIONS: The use of FLACS on the Alcon LenSx platform results in a small decrease in phacoemulsification energy as compared to conventional phacoemulsification in certain cases. Further study assessing optimal laser settings and surgical technique is necessary.


Assuntos
Terapia a Laser/métodos , Facoemulsificação/métodos , Acuidade Visual , Idoso , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento , Ondas Ultrassônicas
6.
Int Ophthalmol ; 37(1): 63-70, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27061903

RESUMO

The purpose of the study was to determine the independent predictors of long-term intraocular pressure (IOP) reduction after cataract surgery with phacoemulsification. This is a retrospective review of uncomplicated cataract surgeries from 2006 to 2008 at the Baltimore VA Medical Center with longitudinal follow-up. Demographic, clinical, biometric, and intraoperative variables including phacoemulsification parameters were recorded. Univariate and multivariate linear regression were used to analyze the relationship between these variables and postoperative IOP, which was the outcome variable. Analysis was performed in 115 eyes of 115 patients who underwent uncomplicated phacoemulsification during the study period. There was an average postoperative IOP reduction through 12, 24, and 36 months of -1.7 ± 3.1, -1.5 ± 3.8, and -1.3 ± 2.6 mmHg, respectively. Higher preoperative IOP (P < 0.001), a more anterior relative lens position (P < 0.05), and longer phaco time (P < 0.05) were significantly associated with greater postoperative decrease in IOP using univariate analysis. Using multivariate analysis, preoperative IOP (P < 0.001), and phaco time (P = 0.038) were associated with greater postoperative IOP reduction through 24 months. Phaco time is independently associated with IOP reduction after adjusting for age and preoperative IOP. Higher preoperative IOP is associated with a greater IOP-lowering effect after phacoemulsification.


Assuntos
Catarata/complicações , Pressão Intraocular/fisiologia , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/patologia , Comprimento Axial do Olho , Catarata/fisiopatologia , Feminino , Humanos , Cristalino/patologia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco
9.
Diagnostics (Basel) ; 14(15)2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39125491

RESUMO

Impaired retinal blood flow is associated with ocular diseases such as glaucoma, macular degeneration, and diabetic retinopathy. Among several ocular imaging techniques developed to measure retinal blood flow both invasively and non-invasively, adaptive optics (AO)-enabled scanning laser ophthalmoscopy (AO-SLO) resolves individual red blood cells and provides a high resolution with which to measure flow across retinal microvasculature. However, cross-validation of flow measures remains a challenge owing to instrument and patient-specific variability in each imaging technique. Hence, there is a critical need for a well-controlled clinical flow phantom for standardization and to establish blood-flow measures as clinical biomarkers for early diagnosis. Here, we present the design and validation of a simple, compact, portable, linear flow phantom based on a direct current motor and a conveyor-belt system that provides linear velocity tuning within the retinal microvasculature range (0.5-7 mm/s). The model was evaluated using a sensitive AO-SLO line-scan technique, which showed a <6% standard deviation from the true velocity. Further, a clinical SLO instrument showed a linear correlation with the phantom's true velocity (r2 > 0.997). This model has great potential to calibrate, evaluate, and improve the accuracy of existing clinical imaging systems for retinal blood flow and aid in the diagnosis of ocular diseases with abnormal blood flow.

10.
Ophthalmol Sci ; 4(5): 100533, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39071915

RESUMO

Objective: To characterize the effect of netarsudil 0.02% on episcleral blood flow in treatment-naive glaucoma suspect or ocular hypertension subjects. Design: Prospective, unmasked, single-arm cohort study. Participants: Ten treatment-naive patients with a diagnosis of glaucoma suspect or ocular hypertension. Methods: Erythrocyte-mediated angiography (EMA) was used to measure episcleral erythrocyte velocity, vessel diameter, and blood flow at baseline before treatment, 1 hour after drop instillation (T1), 1 to 2 weeks after daily netarsudil 0.02% drop use (T2), and 1 hour after drop instillation at the 1-to-2-week time point (T3). Intraocular pressure (IOP) and blood pressure were measured at each visit. Main Outcome Measures: Change in episcleral venous erythrocyte velocity, diameter, and blood flow between time points analyzed using generalized estimating equation models. Results: Of the 18 eligible study eyes of 10 enrolled treatment-naive subjects, baseline IOP was 16.8 ± 3.6 mmHg (mean ± standard deviation), which significantly decreased to 13.9 ± 4.2 mmHg at T1, 12.6 ± 4.1 mmHg at T2, and 11.8 ± 4.7 mmHg at T3 (P < 0.05 at each time point compared with baseline). Episcleral vessels averaged 61.3 ± 5.3 µm in diameter at baseline which increased significantly at all posttreatment time points (78.0 ± 6.6, 74.0 ± 5.2, 76.9 ± 6.9 µm, respectively; mean ± standard deviation, P < 0.05 for each time point). Episcleral venous flowrates were 0.40 ± 0.22 uL/minute (mean ± standard deviation) at baseline, which increased significantly to 0.69 ± 0.45 uL/min at T1 (P = 0.01), did not significantly differ at T2 (0.38 ± 0.30 uL/minute), and increased significantly to 0.54 ± 0.32 uL/minute at T3 (P < 0.05 compared with baseline and T2). Conclusions: Netarsudil causes episcleral venous dilation at all time points and resulting increases in episcleral venous flowrates 1 hour after drop instillation. Increased episcleral venous flow, associated with decreased episcleral venous pressure, may result in lowered IOP. Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

11.
Invest Ophthalmol Vis Sci ; 65(11): 33, 2024 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-39302644

RESUMO

Purpose: The purpose of this study was to identify and measure plexus-specific absolute retinal capillary blood flow velocity and acceleration in vivo in both nonhuman primates (NHPs) and humans using erythrocyte mediated angiography (EMA) and optical coherence tomography angiography (OCTA). Methods: EMA and OCTA scans centered on the fovea were obtained in 2 NHPs and 11 human subjects. Scans were also obtained in NHP eyes while IOP was experimentally elevated. Erythrocyte velocity and acceleration in retinal arteries, capillaries, and veins were measured and capillaries were categorized based on location within the superficial vascular (SVP), intermediate capillary (ICP), or deep capillary plexus (DCP). Generalized linear mixed models were used to estimate the effects of intraocular pressure (IOP) on capillary blood flow. Results: Capillary erythrocyte velocity at baseline IOP was 0.64 ± 0.29 mm/s in NHPs (range of 0.14 to 1.85 mm/s) and 1.55 ± 0.65 mm/s in humans (range of 0.46 to 4.50 mm/s). Mean erythrocyte velocity in the SVP, ICP, and DCP in NHPs was 0.69 ± 0.29 mm/s, 0.53 ± 0.22 mm/s, and 0.63 ± 0.27 mm/s, respectively (P = 0.14 for NHP-1 and P = 0.28 for NHP-2). Mean erythrocyte velocity in the human subjects did not differ significantly among SVP, ICP, and DCP (1.46 ± 0.59 mm/s, 1.58 ± 0.55 mm/s, and 1.59 ± 0.79 mm/s, P = 0.36). In NHPs, every 1 mm Hg increase in IOP was associated with a 0.13 mm/s reduction in arterial velocity, 0.10 mm/s reduction in venous velocity, and 0.01 mm/s reduction in capillary velocity (P < 0.001) when accounting for differences in mean arterial pressure (MAP). Conclusions: Blood flow by direct visualization of individual erythrocytes can be quantified within capillary plexuses. Capillary velocity decreased with experimental IOP elevation.


Assuntos
Capilares , Eritrócitos , Angiofluoresceinografia , Pressão Intraocular , Fluxo Sanguíneo Regional , Vasos Retinianos , Tomografia de Coerência Óptica , Tomografia de Coerência Óptica/métodos , Humanos , Capilares/fisiologia , Capilares/diagnóstico por imagem , Masculino , Vasos Retinianos/fisiologia , Vasos Retinianos/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Fluxo Sanguíneo Regional/fisiologia , Eritrócitos/fisiologia , Angiofluoresceinografia/métodos , Pressão Intraocular/fisiologia , Animais , Adulto , Macaca mulatta , Pessoa de Meia-Idade , Fóvea Central/irrigação sanguínea , Fundo de Olho
12.
Eye Contact Lens ; 39(6): 410-2, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24045832

RESUMO

PURPOSE: To describe a patient with Exophiala jeanselmei keratitis and to review the prior cases reported in the literature. METHODS: We report one patient with keratitis after remote injury and chronic steroid use and review the six prior reported cases. RESULTS: Culture plates from corneal scraping revealed growth of the dematiaceous fungi, E. jeanselmei, a rare causative organism of ocular infection. The patient underwent therapy with topical and intracameral antifungals and subsequently required a corneal transplant. Biopsy of the donor graft confirmed the diagnosis of E. jeanselmei. This is the first reported case to use intracameral antifungal agents and the first biopsy proven case. Half of reported cases experienced associated trauma, and severity was generally related to delay in diagnosis. CONCLUSIONS: Trauma and chronic topical steroid use contributed to the development of severe keratitis in this patient. Patients on chronic steroids should be monitored closely. Topical, subconjunctival, and intracameral antifungals have all been effective in treating this pathogen. If diagnosed and treated early, E. jeanselmei keratitis can have a good visual outcome.


Assuntos
Exophiala/isolamento & purificação , Infecções Oculares Fúngicas/microbiologia , Ceratite/microbiologia , Adulto , Lesões da Córnea , Corpos Estranhos no Olho/complicações , Humanos , Masculino
13.
Bioengineering (Basel) ; 10(10)2023 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-37892838

RESUMO

Over the last two decades, there has been growing interest in assessing corneal biomechanics in different diseases, such as keratoconus, glaucoma, and corneal disorders. Given the interaction and structural continuity between the cornea and sclera, evaluating corneal biomechanics may give us further insights into the pathogenesis, diagnosis, progression, and management of glaucoma. Therefore, some authorities have recommended baseline evaluations of corneal biomechanics in all glaucoma and glaucoma suspects patients. Currently, two devices (Ocular Response Analyzer and Corneal Visualization Schiempflug Technology) are commercially available for evaluating corneal biomechanics; however, each device reports different parameters, and there is a weak to moderate agreement between the reported parameters. Studies are further limited by the inclusion of glaucoma subjects taking topical prostaglandin analogues, which may alter corneal biomechanics and contribute to contradicting results, lack of proper stratification of patients, and misinterpretation of the results based on factors that are confounded by intraocular pressure changes. This review aims to summarize the recent evidence on corneal biomechanics in glaucoma patients and insights for future studies to address the current limitations of the literature studying corneal biomechanics.

14.
Invest Ophthalmol Vis Sci ; 64(14): 21, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37971733

RESUMO

Purpose: To apply adaptive optics-optical coherence tomography (AO-OCT) to quantify multiple sclerosis (MS)-induced changes in axonal bundles in the macular nerve fiber layer, ganglion cell somas, and macrophage-like cells at the vitreomacular interface. Methods: We used AO-OCT imaging in a pilot study of MS participants (n = 10), including those without and with a history of optic neuritis (ON, n = 4), and healthy volunteers (HV, n = 9) to reveal pathologic changes to inner retinal cells and structures affected by MS. Results: We found that nerve fiber layer axonal bundles had 38% lower volume in MS participants (1.5 × 10-3 mm3) compared to HVs (2.4 × 10-3 mm3; P < 0.001). Retinal ganglion cell (RGC) density was 51% lower in MS participants (12.3 cells/mm2 × 1000) compared to HVs (25.0 cells/mm2 × 1000; P < 0.001). Spatial differences across the macula were observed in RGC density. RGC diameter was 15% higher in MS participants (11.7 µm) compared to HVs (10.1 µm; P < 0.001). A nonsignificant trend of higher density of macrophage-like cells in MS eyes was also observed. For all AO-OCT measures, outcomes were worse for MS participants with a history of ON compared to MS participants without a history of ON. AO-OCT measures were associated with key visual and physical disabilities in the MS cohort. Conclusions: Our findings demonstrate the utility of AO-OCT for highly sensitive and specific detection of neurodegenerative changes in MS. Moreover, the results shed light on the mechanisms that underpin specific neuronal pathology that occurs when MS attacks the retina. The new findings support the further development of AO-based biomarkers for MS.


Assuntos
Esclerose Múltipla , Neurite Óptica , Humanos , Esclerose Múltipla/complicações , Projetos Piloto , Tomografia de Coerência Óptica/métodos , Retina/patologia , Células Ganglionares da Retina/patologia , Neurite Óptica/diagnóstico , Neurite Óptica/patologia
15.
iScience ; 26(1): 105755, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36594026

RESUMO

Blood cells trapped in stasis have been reported within the microcirculation, but their relevance to health and disease has not been established. In this study, we introduce an in vivo imaging approach that reveals the presence of a previously-unknown pool of erythrocytes in stasis, located within capillary segments of the CNS, and present in 100% of subjects imaged. These results provide a key insight that blood cells pause as they travel through the choroidal microvasculature, a vascular structure that boasts the highest blood flow of any tissue in the body. Demonstration of clinical utility using deep learning reveals that erythrocyte stasis is altered in glaucoma, indicating the possibility of more widespread changes in choroidal microvascular than previously realized. The ability to monitor the choroidal microvasculature at the single cell level may lead to novel strategies for tracking microvascular health in glaucoma, age-related macular degeneration, and other neurodegenerative diseases.

16.
Transl Vis Sci Technol ; 11(11): 19, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36441132

RESUMO

Purpose: The purpose of this study was to compare autoregulation of retinal arteriolar and venular blood flow in patients with glaucoma, glaucoma suspect participants, and control participants using erythrocyte mediated velocimetry. Methods: This prospective cohort pilot study included 7 eyes of 5 participants with glaucoma, 15 eyes of 8 glaucoma suspect participants, and 11 eyes of 6 control participants. Mean erythrocyte velocity in retinal arterioles and venules was measured using erythrocyte mediated velocimetry at room air and after oxygen supplementation. Change in erythrocyte velocity was compared among all groups using generalized estimating equations. Results: In total, 64 vessels (18 with glaucoma, 31 that were glaucoma suspect, and 15 controls) of 33 eyes of 19 participants were analyzed. There was no significant difference in baseline velocities in arterioles or venules among the three groups. With induction of hyperoxia, mean arterial erythrocyte velocity decreased in glaucoma (-7.2 ± 13.7%), which differed from controls and glaucoma suspects where erythrocyte velocity increased with hyperoxia by 4.6 ± 13.3% (P = 0.002) and 7.2 ± 21.7% (P = 0.03), respectively. A higher baseline arteriolar velocity (ß = -3.9% per mm/s, P = 0.002), glaucoma diagnosis (ß = -21.1%, P = 0.03), and White race (ß = -20.0%, P = 0.01) were associated with decreased velocity in response to arterial hyperoxia. Conclusions: Hyperoxia increased erythrocyte velocity in control and glaucoma suspect participants, but decreased erythrocyte velocity in glaucoma participants, possibly due to impaired autoregulation. Baseline velocity, glaucoma diagnosis, and White race were associated with a decrease in velocity with induction of hyperoxia. Translational Relevance: The European Medicines Agency (EMA) permits precision measurements of blood flow which may aid in the development of biomarkers of glaucoma-related dysregulation of blood flow.


Assuntos
Glaucoma , Hiperóxia , Hipertensão Ocular , Humanos , Projetos Piloto , Estudos Prospectivos , Glaucoma/diagnóstico , Retina , Eritrócitos , Reologia
17.
Ophthalmol Glaucoma ; 5(3): 250-261, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34673279

RESUMO

PURPOSE: To assess the repeatability of blood flow velocity index (BFVi) metrics obtained with a recently Food and Drug Administration-cleared laser speckle contrast imaging device, the XyCAM RI (Vasoptic Medical, Inc), and to characterize differences in these metrics among control, glaucoma suspect, and glaucoma participants. DESIGN: Prospective, observational study. PARTICIPANTS: Forty-six participants: 20 control, 16 glaucoma suspect, and 10 glaucoma participants, 1 eye per participant. METHODS: Key dynamic BFVi metrics-mean, peak, dip, volumetric rise index (VRI), volumetric fall index (VFI), time to rise (TtR), time to fall (TtF), blow-out time (BOT), skew, and acceleration time index-were measured in the optic disc, optic disc vessels, optic disc perfusion region, and macula in 4 imaging sessions on the same day. Intrasession and intersession variability were calculated using the coefficient of variation (CV) for each metric in each region of interest (ROI). Values for each dynamic BFVi variable were compared between glaucoma, glaucoma suspect, and control participants using bivariate and multivariate analysis. Pearson correlation coefficients were used to correlate each variable in each ROI with age, intraocular pressure, cup-to-disc ratio (CDR), mean deviation, pattern standard deviation, retinal nerve fiber layer thickness, and minimum rim width. MAIN OUTCOME MEASURES: Coefficient of variation for the intrasession and intersession variability for each dynamic BFVi metric in each ROI and differences in each metric in each ROI between each diagnostic group. RESULTS: Intersession CV for mean, peak, dip, VRI, VFI, TtR, and TtF ranged from 3.2 ± 2.5% to 11.0 ± 3.8%. Age, CDR, OCT metrics, and visual field metrics showed significant correlations with dynamic BFVi variables. Peak, mean, dip, VRI, and VFI were significantly lower in patients with glaucoma than in control participants in all ROIs except the fovea. These metrics also were significantly lower in glaucoma patients than glaucoma suspect patients in the disc vessels. CONCLUSIONS: Dynamic blood flow metrics measured with the XyCAM RI are reliable, are associated with structural and functional glaucoma metrics, and are significantly different among glaucoma, glaucoma suspect, and control participants. The XyCAM RI may serve as an important tool in glaucoma management in the future.


Assuntos
Glaucoma , Hipertensão Ocular , Glaucoma/diagnóstico , Humanos , Imagem de Contraste de Manchas a Laser , Estudos Prospectivos , Células Ganglionares da Retina , Tomografia de Coerência Óptica/métodos , Estados Unidos
18.
Transl Vis Sci Technol ; 10(4): 29, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34004009

RESUMO

Purpose: We evaluated the patient-control differences and predictive value of the retina as potential biomarkers for schizophrenia. Methods: The institutional study included both eyes of 58 schizophrenia spectrum disorder (SSD) patients (age 37.2 ± 12.3 years) and 35 controls (age 41.1 ± 15.2 years). Retinal nerve fiber layer (RNFL), ganglion cell-inner plexiform layer, outer retinal photoreceptor complex, and total macula thicknesses were measured by optical coherence tomography (OCT). Anterior segment parameters including central corneal thickness, anterior chamber depth, and axial length were measured to rule out confounds on the retinal measures. Results: The peripapillary RNFL was overall significantly thinner in SSD relative to controls (F = 3.97, P = 0.049), most pronounced in the temporal (5.2 µm difference, F = 6.95, P = 0.010) and inferior quadrants (12.1 µm difference, F = 7.32, P = 0.009). There were no significant group differences in thickness for the macular RNFL, ganglion, or photoreceptor cell related measures (P > 0.05). Peripapillary RNFL, central macula, and outer photoreceptor complex thicknesses were together able to classify SSD patients with 80% sensitivity and 71% specificity; area under the curve = 0.82 (95% confidence interval, 0.75-0.88). Conclusions: SSD patients exhibited significant RNFL thinning relative to controls. Notably, retinal thickness measures including both peripapillary and macular data exhibited improved diagnostic accuracy for SSD as compared to these regions alone. Translational Relevance: This is the first study to evaluate the predictive value of both the inner and outer retina in SSD. OCT retinal thickness measures including peripapillary data in conjunction with macular data may provide an informative, noninvasive in vivo ocular biomarker for schizophrenia.


Assuntos
Macula Lutea , Esquizofrenia , Adulto , Biomarcadores , Humanos , Macula Lutea/diagnóstico por imagem , Pessoa de Meia-Idade , Fibras Nervosas , Células Ganglionares da Retina , Esquizofrenia/diagnóstico , Tomografia de Coerência Óptica , Adulto Jovem
19.
J Glaucoma ; 30(5): e222-e226, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33596011

RESUMO

The study was a prospective observational study comparing semiautomated to manual quantitative ultrasound biomicroscopy image analysis among 82 images from 41 eyes of 32 subjects (21 controls and 11 glaucoma) enrolled in the Pediatric Anterior Segment Imaging Innovation Study. Intraclass correlation coefficients and correlation coefficients were >0.8 for all parameters, and comparison of respective analysis speed was 7 times faster for the semiautomated method compared with manual image quantification.


Assuntos
Glaucoma , Microscopia Acústica , Segmento Anterior do Olho/diagnóstico por imagem , Criança , Glaucoma/diagnóstico por imagem , Humanos , Pressão Intraocular , Estudos Prospectivos
20.
Ther Adv Ophthalmol ; 12: 2515841420950508, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32923939

RESUMO

OCTA imaging in optic neuropathies.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa