Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Eixos temáticos
Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 15(12): 1205-1215, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35595672

RESUMO

BACKGROUND: Distal radial access (DRA) has been proposed to improve procedure ergonomics and favor radial artery patency. Although promising data, nothing is known on evolving hand function after DRA. OBJECTIVES: This study sought to comprehensively evaluate hand function in patients undergoing DRA. METHODS: Real-world patients undergoing DRA undertook a thorough multimodality assessment of hand function implementing multidomain questionnaires (Disabilities of the Arm, Shoulder and Hand and Levine-Katz), and motor (pinch grip test) and sensory (Semmes-Weinstein monofilaments test) examinations of both hands. All assessments were performed at preprocedural baseline and planned at 1-, 6-, and 12-month follow-up (FU). Adverse clinical and procedural events were documented too. RESULTS: Data of 313 patients (220 men, age 66 ± 10 years) from 9 international centers were analyzed. The Disabilities of the Arm, Shoulder and Hand and the Levine-Katz scores slightly improved from baseline to FU (P = 0.008 and P = 0.029, respectively). Pinch strength mildly improved from baseline to FU (P < 0.001 for both the left and right hands). Similarly, touch pressure threshold appeared to faintly improve in both the left and right hands (P < 0.012 for all the sites). For both motor and sensory function tests, comparable findings were found for the DRA hand and the contralateral one, with no significant differences between them. Repeated assessment of all tests over all FU time points similarly showed lack of worsening hand function. Access-related adverse events included 19 harmless bleedings and 3 forearm radial artery and 3 distal radial artery occlusions. None affected hand function at FU. CONCLUSIONS: In a systematic multidimensional assessment, DRA was not associated with hand function impairment. Moreover, DRA emerges as a safe alternative vascular access.


Assuntos
Arteriopatias Oclusivas , Artéria Radial , Idoso , Mãos , Hemorragia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
2.
Open Heart ; 7(2)2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33046595

RESUMO

OBJECTIVES: Determine whether an ultrathin biodegradable polymer sirolimus-eluting stent ('Orsiro'-BP-SES) has clinical benefits over second-generation durable polymer drug-eluting stents (DP-DES). METHODS: We conducted a prospective systematic review and meta-analysis of randomised clinical trials comparing Orsiro BP-SES against DP-DES (PROSPERO Registration: CRD42019147136). The primary outcome was target lesion failure (TLF): composite of cardiac death, target vessel myocardial infarction (TVMI) and clinically indicated target lesion revascularisation (TLR)) evaluated at the longest available follow-up. RESULTS: Nine trials randomised 11 302 patients to either Orsiro BP-SES or DP-DES. At mean weighted follow-up of 2.8 years, the primary outcome (TLF) occurred in 501 of 6089 (8.2%) participants with BP-SES compared with 495 of 5213 (9.5%) participants with DP-DES. This equates to an absolute risk reduction of 1.3% in TLF in favour of Orsiro BP-SES (OR 0.82; 95% CI 0.69 to 0.98; p=0.03). This was driven by a reduction in TVMI (OR 0.80; 95% CI 0.65 to 0.98; p=0.03). There were no significant differences in other clinical endpoints: cardiac death, TLR and stent thrombosis. CONCLUSION: The Orsiro BP-SES shows promising clinical outcomes in patients undergoing percutaneous coronary intervention compared with contemporary second-generation DES at a short to medium term follow-up. More research is warranted to evaluate performance over a longer follow-up period and in different clinical and lesion subsets.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa