RESUMO
AIMS: Participation in outdoor cold-water swimming (OCWS) events combines endurance exercise and cold exposure. Concerns have emerged about the potential risk of acute adverse cardiac events during OCWS, particularly during endurance events. We analysed the effect of prolonged OCWS on cardiac function in trained athletes. METHODS: The swimming event consisted of laps over a 1000-m course, for up to 6 h, in water at 15 °C. Twenty participants (11 males, 47.3 ± 8.6 years old) were included. Core temperature (Tcore) was monitored using an ingestible temperature sensor during and up to 1 h after the swim. Body composition, blood pressure, electrocardiogram (ECG), and transthoracic echocardiography were assessed 1 day before the event and within the first hour upon completion of the swim. RESULTS: Mean body mass index was 27.1 ± 5.1 kg/m2 and fat mass was 25.2 ± 9.1 %. Mean duration of swimming was 214 ± 115 min. Minimum Tcore was 35.6 ± 1.3 °C. A significant lengthening of the QT interval corrected (QTc) for heart rate was observed post-exercise (437.7 ± 27.7 vs. 457.2 ± 35.9 ms, p = 0.012), with 5 participants exhibiting post-exercise QTc >500ms. OCWS did not alter the biventricular systolic function and left ventricular relaxation. No correlation was observed between ΔQTc and ΔTcore. CONCLUSION: OCWS seemed to acutely delay post-exercise cardiac repolarization without alteration of cardiac function in a healthy trained population. Additional investigations would be warranted to explore the clinical implications of QT lengthening and its relationship with autonomic nervous system regulation during OCWS.
RESUMO
An increase in left ventricular volumes between baseline and follow-up imaging is the main criteria for the quantification of left ventricular remodelling (LVR) after ST-elevation myocardial infarction (STEMI), but without consensual definition. We aimed to review the criteria used for the definition of LVR based on cardiac magnetic resonance imaging (CMR) in STEMI patients. A systematic literature search was conducted using MEDLINE and the Cochrane Library from January 2010 to August 2019. Thirty-seven studies involving 4209 patients were included. Among these studies, 30 (81%) used a cut-off value for defining LVR, with a pooled LVR prevalence estimate of 22.8%, 95% CI [19.4-26.7%] and a major between-study heterogeneity (I2 = 82%). The seven remaining studies (19%) defined LVR as a continuous variable. The definition of LVR using CMR following STEMI is highly variable, among studies including highly selected patients. A 20% increase or a 15% increase in left ventricular volumes between a baseline and a follow-up CMR imaging were the two most common criterion (13 [35%] and 9 [24%] studies, respectively). The most frequent LVR criterion was a 20% increase in end-diastolic volumes or a 15% increase in end-systolic volumes. A composite cut-off value of a 12 to 15% increase in end-systolic volume and a 12 to 20% increase in end-diastolic volume using a follow-up CMR imaging 3 months after STEMI might be proposed as a consensual cut-off for defining adverse LVR for future large-sized, prospective studies with serial CMR imaging and long-term follow-up in unselected patients.
Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Estudos Prospectivos , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação VentricularRESUMO
BACKGROUND: Left ventricular remodeling (LVR) is common and associated with adverse outcome after ST-elevation myocardial infarction (STEMI). We aimed to investigate the association between left atrial (LA) mechanical function using speckle tracking imaging and early LVR at follow-up in STEMI patients. METHODS: Baseline 3D thoracic echocardiograms were performed within 48 h following admission and at a median follow-up of 7 months after STEMI. A > 20% increase in the left ventricular (LV) end-diastolic volume compared to baseline at follow-up was defined as LVR. LA global longitudinal strain was evaluated for the reservoir, conduit, and contraction (LASct) phases. RESULTS: A total of 121 patients without clinical heart failure (HF) were prospectively included, between June 2015 and October 2018 (age 58.3 ± 12.5 years, male 98 (81%)). Baseline and follow-up LV ejection fraction (LVEF) were 46.8% [41.0, 52.9] and 52.1% [45.8, 57.0] respectively (p < .001). Compared to other patients, those with LVR had significantly lower values of LASct at baseline (-7.4% [-10.1, -6.5] vs. -9.9% [-12.8, -8.1], p < .01), both on univariate and baseline LV volumes-adjusted analyses. Baseline LA strain for reservoir and conduit phases were not associated with significant LVR at follow-up. Intra- and interobserver analysis showed good reproducibility of LA strain. CONCLUSIONS: Baseline LASct may help identifying patients without HF after STEMI who are at higher risk of further early LVR and subsequent HF and who may benefit from more intensive management.
Assuntos
Fibrilação Atrial , Infarto do Miocárdio , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Remodelação Ventricular , Reprodutibilidade dos Testes , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico por imagemRESUMO
BACKGROUND: The left ventricular ejection fraction (LVEF) is the key selection criterion for an implanted cardioverter defibrillator (ICD) in primary prevention of sudden cardiac death. LVEF is usually assessed by two-dimensional echocardiography, but cardiovascular magnetic resonance (CMR) imaging is increasingly used. The aim of our study was to evaluate whether LVEF assessment using CMR imaging (CMR-LVEF) or two-dimensional echocardiography (2D echo-LVEF) may predict differently the occurrence of clinical outcomes. METHODS: In this retrospective study, we reviewed patients referred for primary prevention ICD implantation to Caen University Hospital from 2005 to 2014. We included 173 patients with either ischemic (n = 120) or dilated cardiomyopathy (n = 53) and who had undergone pre-ICD CMR imaging. The primary composite end point was the time to death from any cause or first appropriate device therapy. RESULTS: The mean CMR-LVEF was significantly lower than the mean 2D echo-LVEF (24% ± 6 vs 28% ± 6, respectively; p < 0.001). CMR-LVEF was a better independent predictive factor for the occurrence of the primary composite endpoint with a cut-off value of 22% (Hazard Ratio [HR] = 2.22; 95% CI [1.34-3.69]; p = 0.002) than 2D echo-LVEF with a cut-off value of 26% (HR = 1.61; 95% CI [0.99-2.61]; p = 0.056). Combination of the presence of scar with CMR-LVEF< 22% improved the predictive value for the occurrence of the primary outcome (HR = 2.58; 95% CI [1.54-4.30]; p < 0.001). The overall survival was higher among patients with CMR-LVEF≥22% than among patients with CMR-LVEF< 22% (p = 0.026), whereas 2D echo-LVEF was not associated with death. CONCLUSIONS: CMR-LVEF is better associated with clinical outcomes than 2D echo-LVEF in primary prevention using an ICD. Scar identification further improved the outcome prediction. The combination of CMR imaging and echocardiography should be encouraged in addition to other risk markers to better select patients.
Assuntos
Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Ecocardiografia , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Prevenção Primária/instrumentação , Volume Sistólico , Função Ventricular Esquerda , Idoso , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do TratamentoRESUMO
AIMS: Limited data exist concerning fragmented QRS complexes (fQRSs) on the surface electrocardiogram (ECG) of apparently healthy athletes. We aimed to study the prevalence and significance of fQRS in lead V1 (fQRSV1), representing right ventricular (RV) activation, regarding training-induced RV morphological remodelling. METHODS AND RESULTS: Between January 2017 and August 2019, 434 consecutive non-sedentary subjects underwent preparticipation cardiovascular screening, including a 12-lead ECG. Three hundred and ninety-three apparently healthy subjects were included, 119 of them were athletes (defined as performing ≥8 h/week for the last 6 months) and 274 were non-athletes. All athletes underwent two-dimensional transthoracic echocardiography. Fragmented QRS complex in lead V1 pattern was defined as a narrow (<120 ms) and quadriphasic QRS complex in lead V1. Fragmented QRS complex in lead V1 was more frequent in athletes compared with non-athletes (22% vs. 5.1%, P < 0.001) and was independently associated with the athlete status [adjusted odds ratio (aOR) = 4.693, 95% confidence interval (95% CI) 2.299-9.583; P < 0.001], the endurance category (aOR = 2.522, 95% CI 1.176-5.408; P = 0.017), and age (aOR = 0.962, 95% CI 0.934-0.989; P = 0.007) in multivariate analysis. In the subgroup of athletes, fQRSV1 was independently associated with mean RV outflow tract diameter (aOR = 1.458, 95% CI 1.105-1.923; P = 0.008) and age (aOR = 0.941, 95% CI 0.894-0.989; P = 0.017) in multivariate analysis. CONCLUSION: Fragmented QRS complex in lead V1 is a newly described, frequent, ECG pattern in young and apparently healthy athletes and is associated with training-induced RV remodelling.
Assuntos
Atletas , Eletrocardiografia , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , PrevalênciaRESUMO
BACKGROUND: Left ventricular remodeling following ST-elevation myocardial infarction (STEMI) is associated with poor outcome, including heart failure (HF). Neprilysin inhibition leads to improved outcome in patients with altered left ventricular ejection fraction (LVEF). METHODS: We aimed to assess the association between serum levels of neprilysin and left ventricular (LV) volumes, function and remodeling in STEMI patients with successful myocardial reperfusion and no clinical sign of HF. Sixty-eight patients were admitted for STEMI and had both plasma neprilysin measurement at baseline and 3D transthoracic echocardiogram at baseline and after a median follow-up of 7 months. We compared 3 groups: a group with a low-level of plasma neprilysin (< 125 pg/mL, i.e. the lower limit of detection of the assay) and the two other groups were defined as being below or above the median value of the remaining samples. RESULTS: Median age was 58.5 ± 12.8 years and 56 (82.4%) were men. Median LVEF was 45.0 ± 8.5%. Baseline characteristics were comparable between groups (low-level of neprilysin group [≤125 pg/mL, n = 38], medium-level of neprilysin group [126-450 pg/mL, n = 15] and a high-level group [> 450 pg/mL, n = 15]). At baseline there was a non-significant trend towards lower end-diastolic volume (p = 0.07) but significantly lower LVEF in the high neprilysin group (46.4 ± 8.3%, 47.1 ± 8.1% and 39.1 ± 6.9%, p < 0.01). At follow-up, the magnitude of LVEF increase was significantly more important in the high neprilysin group compared to the other groups (p = 0.022 for relative change in LVEF and 6.6 ± 7.3%, 3.6 ± 9.0% and 11.3 ± 8.4%, p = 0.031 for absolute change in LVEF) resulting in similar LVEF levels at follow-up between all groups (53.0 ± 8.9%, 50.6 ± 9.7% and 50.4 ± 9.9%, p = 0.55). CONCLUSIONS: Initial high neprilysin levels may identify patients with stunned myocardium early after STEMI, with a recovery of contractility leading to improved LVEF at follow-up. Future studies will have to assess the role of neprilysin in the setting of STEMI and the potential benefit of its blockade.
Assuntos
Miocárdio Atordoado/sangue , Neprilisina/sangue , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Função Ventricular Esquerda , Remodelação Ventricular , Adulto , Idoso , Biomarcadores/sangue , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Miocárdio Atordoado/diagnóstico , Miocárdio Atordoado/fisiopatologia , Estudos Prospectivos , Recuperação de Função Fisiológica , Infarto do Miocárdio com Supradesnível do Segmento ST/sangue , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Left ventricular untwisting generates an early diastolic intraventricular pressure gradient (DIVPG) than can be quantified by echocardiography. We sought to confirm the quantitative relationship between peak untwisting rate and peak DIVPG in a large adult population. METHODS: From our echocardiographic database, we retrieved all the echocardiograms with a normal left ventricular ejection fraction, for whom color Doppler M-Mode interrogation of mitral inflow was available, and left ventricular untwisting rate was measurable using speckle tracking. Standard indices of left ventricular early diastolic function were assessed by Doppler (peaks E, e' and Vp) and speckle tracking (peak strain rate Esr). Load dependency of DIVPG and untwisting rate was evaluated using a passive leg raising maneuver. RESULTS: We included 154 subjects, aged between 18 to 77 years old, 63% were male. Test-retest reliability for color Doppler-derived DIVPG measurements was good, the intraclass correlation coefficients were 0.97 [0.91-0.99] and 0.97 [0.67-0.99] for intra- and inter-observer reproducibility, respectively. Peak DIVPG was positively correlated with peak untwisting rate (r = 0.73, P < 0.001). On multivariate analysis, peak DIVPG was the only diastolic parameter that was independently associated with untwisting rate. Age and gender were the clinical predictive factors for peak untwisting rate, whereas only age was independently associated with peak DIVPG. Untwisting rate and DIVPG were both load-dependent, without affecting their relationship. CONCLUSIONS: Color Doppler-derived peak DIVPG was quantitatively and independently associated with peak untwisting rate. It thus provides a reliable flow-based index of early left ventricular diastolic function.
Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler/métodos , Ventrículos do Coração/diagnóstico por imagem , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Adulto , Diástole , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Adulto JovemRESUMO
PURPOSE: Cardiac stiffness is a marker of diastolic function with a strong prognostic significance in many heart diseases that is not measurable in clinical practice. This study investigates whether elastometry, a surrogate for organ stiffness, is measurable in the heart using ShearWave Imaging. METHODS: In 33 anesthetized patients scheduled for cardiac surgery, ShearWave imaging was acquired epicardially using a dedicated ultrasound machine on the left ventricle parallel to the left anterior descending coronary artery in a loaded heart following the last cardiac beat. Cardiac elastometry was measured offline using the Young modulus with customized software. RESULTS: Overall, the ejection fraction was 61 ± 10%. E/A and E/e' ratios were 1.0 ± 0.5 and 10.5 ± 4.1, respectively. Cardiac elastometry averaged 15.3 ± 5.3 kPa with a median of 18 kPa. Patients with high elastometry >18 kPa were older (P = .04), had thicker (P = .02) but smaller LV (P = .004), had larger left atria (P = .05) and a higher BNP level (P = .04). We distinguished three different transmural elastometry patterns: higher epicardial, higher endocardial, or uniformly distributed elastometry. CONCLUSION: Elastometry measurement was feasible for the human heart. This surrogate for cardiac stiffness dichotomized patients with low and high elastometry, and provided three different phenotypes of transmural elastometry with link to diastolic function.
Assuntos
Disfunção Ventricular Esquerda , Diástole , Ecocardiografia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Projetos PilotoAssuntos
Transplante de Coração , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Falha de Prótese , Ecocardiografia TransesofagianaRESUMO
INTRODUCTION AND OBJECTIVES: Cardiac manifestations in Fabry disease are mainly characterized by left ventricular hypertrophy (LVH). The aims of this study were (1) to describe the pattern of regional strain in patients with Fabry disease and (2) to assess whether this pattern may help differentiate patients with Fabry disease from patients with sarcomeric hypertrophic cardiomyopathy (HCM). METHODS: Seventy-seven subjects were investigated: patients with Fabry disease (n=37; 57% with LVH), patients with HCM (n=21), and healthy controls (n=19). Global and segmental longitudinal and circumferential strain (CS) analyses were performed by two-dimensional speckle strain imaging. Base-to-apex longitudinal and CS gradient, defined as the peak gradient difference between averaged basal and apical strain, was calculated. RESULTS: Longitudinal strain gradient did not differ between controls and Fabry patients without hypertrophy (respectively: -10±3.2 vs -8±4.3, P=.41) or between the HCM group and Fabry patients with hypertrophy (respectively: -7.5±4.5 vs -9±4.5, P=.37). The CS gradient was lower in Fabry patients without hypertrophy compared to the controls (respectively: 1±8 vs 14.2±9.5, P<.01), and lower in Fabry patients with hypertrophy compared to the HCM group (respectively: 0.5±8 vs 6±9, P<.01). Base-to-apex CS gradient was lost in both Fabry groups. CONCLUSION: Loss of base-to-apex CS gradient may be a specific left ventricular deformation pattern of Fabry cardiomyopathy in patients with and without LVH.
Assuntos
Ecocardiografia/métodos , Doença de Fabry/complicações , Hipertrofia Ventricular Esquerda/complicações , Hipertrofia Ventricular Esquerda/diagnóstico por imagem , Adulto , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Estudos Transversais , Diagnóstico Diferencial , Doença de Fabry/fisiopatologia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos TestesRESUMO
AIMS: After an old myocardial infarction (MI), patients are at risk for reentrant ventricular tachycardia (VT) due to scar tissue that can be accurately identified by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR). Although the ability of LGE-CMR to predict sustained VT in implantable cardioverter-defibrillator (ICD) recipients has been well established, its use to predict monomorphic VT (sustained or not) cycle length (CL) and so, optimize ICD programming has never been investigated. METHODS AND RESULTS: We included retrospectively 49 consecutive patients with an old MI who had undergone LGE-CMR before ICD implantation over a 4-year period (2006-09). Patients with amiodarone used were excluded. Scar extent was assessed by measuring scar mass, percent scar, and transmural scar extent. The endpoint was the occurrence of monomorphic VT, requiring an ICD therapy or not. The endpoint occurred in 26 patients. The median follow-up duration was 31 months. Scar extent parameters were significantly correlated with the study endpoint. With univariate regression analysis, the scar mass had the highest correlation with the VT CL (R = 0.671, P = 0.0002). Receiver-operating characteristic curve showed that scar mass can predict VT CL (area under the curve = 0.977, P < 0.0001). For a cut-off value of scar mass at 17.6 g, there is 100% specificity and 94.4% sensitivity. CONCLUSION: In this observational and retrospective study, scar mass studied by LGE-CMR was specific and sensitive to predict VT CL and so could be a promising option to improve ICD post-implantation programming and decrease appropriate and inappropriate shocks. These conclusions must now be confirmed in a large and prospective study.
Assuntos
Cicatriz/etiologia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Imageamento por Ressonância Magnética , Infarto do Miocárdio/complicações , Miocárdio/patologia , Taquicardia Ventricular/terapia , Idoso , Área Sob a Curva , Cicatriz/patologia , Meios de Contraste , Feminino , Humanos , Masculino , Meglumina , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Compostos Organometálicos , Seleção de Pacientes , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Resultado do TratamentoRESUMO
OBJECTIVE: The purpose of this study was to assess cardiac shear wave imaging implemented in a new MACH 30 ultrasound machine (SuperSonic Imaging, Aix-en-Provence, France) and interfaced with a linear probe and a phased array probe, in comparison with a previously validated Aixplorer system connected to a linear probe (SuperSonic Imaging) using Elasticity QA phantoms (Models 039 and 049, CIRS Inc., Norfolk, VA, USA). METHODS: Quantile-quantile plots were used for distribution agreement. The accuracy of stiffness measurement was assessed by the percentage error and the mean percentage error (MPE), and its homogeneity, by the standard deviation of the MPE. A p value <0.01 was considered to indicate statistical significance. RESULTS: The accuracy of dedicated cardiac sequences for linear probes was similar for the two systems with an MPE of 8 ± 14% versus 20 ± 21% (p = not significant) with the SuperSonic MACH 30 and Aixplorer, respectively, and was influenced by target stiffness and location of the measurement in the field of view, but without drift over time. The optimal transthoracic cardiac probe workspace was located between 4 and 10 cm, with an MPE of 29.5 ± 25% compared with 93.3 ± 130% outside this area (p < 0.0001). In this area, stiffness below 20 kPa was significantly different from the reference (p < 0.0001). The sectorial probe revealed no MPE difference in any of the measurement areas, with no significant lateral or axial gradient. CONCLUSION: The new Supersonic MACH 30 system upgraded with a sectorial probe and specific cardiac settings provided homogenous stiffness measurements, especially when operating at depths between 4 and 10 cm. These phantom results may be useful in designing future in vivo studies.
Assuntos
Técnicas de Imagem por Elasticidade , Desenho de Equipamento , Imagens de Fantasmas , Técnicas de Imagem por Elasticidade/métodos , Técnicas de Imagem por Elasticidade/instrumentação , Reprodutibilidade dos Testes , Humanos , Módulo de Elasticidade , Análise de Falha de Equipamento , Coração/diagnóstico por imagem , Sensibilidade e Especificidade , Ecocardiografia/métodos , Ecocardiografia/instrumentaçãoRESUMO
BACKGROUND: Recent studies on American-style football (ASF) athletes raised questions about the impact of training on the cardiovascular phenotype, particularly among linemen players who engage mostly in static exercise during competition and who exhibit concentric cardiac remodeling, often considered maladaptive. We aimed to examine the cardiovascular adaptation to the inter-season mixed-team training program among ASF players. METHODS: A prospective, longitudinal, cohort study was conducted among competitive male ASF players from the University of Montreal before and after an inter-season training, which lasted 7 months. This program includes, for all players, combined dynamic and static exercises. Clinical and echocardiographic examinations were performed at both steps. Left atrial (LA) and ventricular (LV) morphological and functional changes were assessed using a multiparametric echocardiographic approach (2D and 3D-echo, Doppler, and speckle tracking). Two-way ANOVA was performed to analyze the impacts of time and field position (linemen versus non-linemen). RESULTS: Fifty-nine players (20 linemen and 39 non-linemen) were included. At baseline, linemen had higher blood pressure (65% were prehypertensive and 10% were hypertensive), thicker LV walls, lower LV systolic and diastolic functions, lower LA-reservoir and conduit functions than non-linemen. After training, linemen significantly reduced weight (Δ-3.4%, P < 0.001) and systolic blood pressure (Δ-4.5%, P < 0.001), whereas non-linemen maintained their weight and significantly increased their systolic (Δ+4.2%, P = 0.037) and diastolic (Δ+16%, P < 0.001) blood pressure ). Mixed training was associated with significant increases in 2D-LA volume (P < 0.001), 3D-LV end-diastolic volume (P < 0.001), 3D-LV mass (P < 0.001), and an improvement in LV systolic function, independently of the field position. Non-linemen remodeled their LV in a more concentric fashion and showed reductions in LV diastolic and LA reservoir functions. CONCLUSIONS: Our study underscored the influence of field position on cardiovascular adaptation among university-level ASF players, and emphasized the potential of inter-season training to modulate cardiovascular risk factors, particularly among linemen.
RESUMO
Pre-participation screening and management of congenital cardiac valvulopathy in competitive athletes can be challenging, particularly within the context of ultra-endurance disciplines. A 55-year-old female athlete without a reported history of cardiac disease exhibited clinical signs of cardiogenic pulmonary edema during a 156â¯km ultra-trail race. The echocardiographic assessment revealed the presence of a parachute mitral valve, with no evidence of mitral stenosis or regurgitation at rest, but it demonstrated severe dynamic mitral stenosis during exercise. In competitive athletes, the detection of rare valvulopathy should prompt a comprehensive cardiac evaluation aimed at assessing the potential for dynamic valvular dysfunction.
Assuntos
Ecocardiografia , Estenose da Valva Mitral , Valva Mitral , Humanos , Feminino , Pessoa de Meia-Idade , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Valva Mitral/anormalidades , Edema Pulmonar/diagnóstico por imagem , AtletasRESUMO
BACKGROUND: Coronary artery disease (CAD) patients are at risk for life-threatening ventricular arrhythmias (VA) related to scar tissue. Late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) can accurately identify myocardial scar extent. It has been shown that scar extent, particularly scar transmurality, percent scar and scar mass, are associated with the occurrence of appropriate implantable cardioverter-defibrillator (ICD) therapy. However, quantification of transmurality extent has never been studied. The purpose of our study was to evaluate whether different methods quantifying scar transmurality, percent scar and scar mass (assessed with LGE-CMR) can predict appropriate ICD therapy in CAD patients with a long term follow-up period. METHODS AND RESULTS: We enrolled retrospectively 66 patients with chronic CAD referred for primary or secondary preventive ICD implantation and LGE-CMR before ICD implantation. Using LGE-CMR, scar extent was assessed by measuring scar mass, percent scar and transmural scar extent using four different methods. The median follow-up duration was 41.5 months (interquartile range 22-52). The endpoint was the occurrence of appropriate device therapy and occurred in 14 patients. Pre-ICD revascularization and transmural scar extent were significantly associated with the study endpoint but the latter was especially highly dependent on the method used. Patients with appropriate device therapy had also larger scar mass (29.6 ± 14.5 g vs 17.1 ± 8.8 g, p = 0.004), and larger percent scar (15.1 ± 8.2% vs 9.9 ± 5.6%, p = 0.03) than patients without appropriate device therapy. In multivariate analysis, scar extent variables remained significantly associated with the study end-point. CONCLUSIONS: In this study of CAD patients implanted for primary or secondary preventive ICD, pre-ICD revascularization and scar extent studied by LGE-CMR were significantly associated with appropriate device therapy and can identify a subgroup of CAD patients with an increased risk of life-threatening VA. Depending of the method used, transmural scar extent may vary significantly and needs further studies to obtain a validated and consensual study method.
Assuntos
Arritmias Cardíacas/prevenção & controle , Meios de Contraste , Doença da Artéria Coronariana/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Imagem Cinética por Ressonância Magnética , Meglumina , Miocárdio/patologia , Compostos Organometálicos , Prevenção Primária , Prevenção Secundária , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Função Ventricular EsquerdaRESUMO
BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.
Assuntos
Marca-Passo Artificial , Síndromes da Apneia do Sono , Idoso , Humanos , Sono , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Polissonografia , AlgoritmosRESUMO
BACKGROUND: As strength sports gain popularity, there is a growing need to explore the impact of sustained strength training on cardiac biventricular structure and function, an area that has received less attention compared to the well-established physiological cardiac adaptation to endurance training. OBJECTIVE: This study aims to implement a 20-week high-intensity strength training program to enhance maximal muscle strength and evaluate its impact on cardiac biventricular adaptation in healthy, untrained men. METHODS: A total of 27 healthy and untrained young men (mean age 22.8, SD 3.2 years) participated in a strength training program designed to increase muscle strength. The training program involved concentric, eccentric, and isometric exercise phases, conducted over a consecutive 20-week time frame with a frequency of 3 weekly training sessions. Participants were evaluated before and after 12 and 20 weeks of training through body composition analysis (bioelectrical impedance), a 12-lead resting electrocardiogram, 3D transthoracic echocardiography, cardiopulmonary exercise testing, and muscle isokinetic dynamometry. The progression of strength training loads was guided by 1-repetition maximum (RM) testing during the training program. RESULTS: Of the initial cohort, 22 participants completed the study protocol. No injuries were reported. The BMI (mean 69.8, SD 10.8 kg/m² vs mean 72, SD 11 kg/m²; P=.72) and the fat mass (mean 15.3%, SD 7.5% vs mean 16.5%, SD 7%; P=.87) remained unchanged after training. The strength training program led to significant gains in 1-RM exercise testing as early as 4 weeks into training for leg extension (mean 69.6, SD 17.7 kg vs mean 96.5, SD 31 kg; P<.001), leg curl (mean 43.2, SD 9.7 kg vs mean 52.8, SD 13.4 kg; P<.001), inclined press (mean 174.1, SD 41.1 kg vs mean 229.2, SD 50.4 kg; P<.001), butterfly (mean 26.3, SD 6.2 kg vs mean 32.5, SD 6.6 kg; P<.001), and curl biceps on desk (mean 22.9, SD 5.2 kg vs mean 29.6, SD 5.2 kg; P<.001). After 20 weeks, the 1-RM leg curl, bench press, pullover, butterfly, leg extension, curl biceps on desk, and inclined press showed significant mean percentage gains of +40%, +41.1%, +50.3%, +63.5%, +80.1%, +105%, and +106%, respectively (P<.001). Additionally, the isokinetic evaluation confirmed increases in maximal strength for the biceps (+9.2 Nm), triceps (+11.6 Nm), quadriceps (+46.8 Nm), and hamstrings (+25.3 Nm). In this paper, only the training and muscular aspects are presented; the cardiac analysis will be addressed separately. CONCLUSIONS: This study demonstrated that a short-term high-intensity strength training program was successful in achieving significant gains in muscle strength among previously untrained young men. We intend to use this protocol to gain a better understanding of the impact of high-intensity strength training on cardiac physiological remodeling, thereby providing new insights into the cardiac global response in strength athletes. TRIAL REGISTRATION: ClinicalTrials.gov NCT04187170; https://clinicaltrials.gov/study/NCT04187170.
RESUMO
AIMS: Left ventricle ejection fraction (LVEF) ≤ 30-35% is widely accepted as a cut-off for primary prevention with an implantable cardiac defibrillator (ICD) in patients with both ischaemic and non-ischaemic cardiomyopathy supposedly on optimal medical therapy. This study reports evolutions of LVEF and treatments of patients implanted in our institution with an ICD for primary prevention of sudden death, after 2 years of follow-up. METHODS AND RESULTS: Among 84 patients with LVEF under 35% implanted between 2005 and 2007, 28 (33%) had improved their LVEF >35% after the 2 years of follow-up. During this period, even if Beta-blockers (98%) and renin-angiotensin system (RAS) blockers (95%) were already initially prescribed, treatments were significantly optimized with improvement of maximal doses of beta-blockers and RAS blockers at 2 year follow-up compared with initial prescription (62 vs. 37% and 68 vs. 45%, respectively). In patients with improved LVEF, a trend toward a better treatment optimization and revascularization procedures (in the sub-group of ischaemic patients) were observed compared with non-improved LVEF patients. CONCLUSIONS: In our study of patients with prophylactic ICD, one-third of them have improved their LVEF after a 2 year follow-up. Despite an optimal medical therapy at the time of implantation, we were able to further improve the maximal treatment doses after implantation. This study highlights the issue of what should be considered as 'optimal' therapy and the possibility of improvement of LVEF related to a real optimized treatment before implantation.
Assuntos
Cardiomiopatias/terapia , Fármacos Cardiovasculares/uso terapêutico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica , Prevenção Primária , Disfunção Ventricular Esquerda/terapia , Antagonistas Adrenérgicos beta/uso terapêutico , Adulto , Idoso , Bloqueadores do Receptor Tipo 1 de Angiotensina II/uso terapêutico , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Cardiomiopatias/complicações , Cardiomiopatias/fisiopatologia , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária/instrumentação , Prevenção Primária/métodos , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico/efeitos dos fármacos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacosRESUMO
AIM: Age-associated changes in cardiac filling and function are well known in the general population. Yet, the effect of aging on left atrial (LA) function, and its interaction with left ventricular (LV) adaptation, remain less described when combined with high-intensity chronic training. We aimed to analyze the effects of aging on LA and LV functions in trained athletes. METHODS AND RESULTS: Ninety-five healthy highly-trained athletes referred for resting echocardiography were included. Two groups of athletes were retrospectively defined based on age: young athletes aged <35 years (n = 54), and master athletes aged ≥35 years (n = 41). All subjects were questioned about their sports practice. Echocardiographic analysis of LV systolic and diastolic functions (2D-echo, 3D-echo, and Doppler), as well as LA 2D dimensions and phasic deformations assessed by speckle tracking, were analyzed. Master athletes (mean age = 46.3 ± 8.3 years, mean duration of sustained training = 13.7 ± 8.9 years) exhibited significantly stiffer LV and LA with reduced LV early diastolic functional parameters (ratio E/A, peak e', and ratio e'/a'), LA reservoir and conduit strain, whereas LA volume, LA contractile strain and LV peak a' were higher, compared to young athletes. Multivariate regression analysis confirmed that age was predictive of peak e', LA reservoir strain and LA conduit strain, independently of training variables. LA phasic strains were strongly associated with LV diastolic function. CONCLUSIONS: Regardless of chronic sports practice, master athletes exhibited age-related changes in LA function closely coupled to LV diastolic properties, which led to LV filling shifts to late diastole.
Assuntos
Função do Átrio Esquerdo , Remodelamento Atrial , Adulto , Atletas , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Função Ventricular EsquerdaRESUMO
Motion estimation in echocardiography plays an important role in the characterization of cardiac function, allowing the computation of myocardial deformation indices. However, there exist limitations in clinical practice, particularly with regard to the accuracy and robustness of measurements extracted from images. We therefore propose a novel deep learning solution for motion estimation in echocardiography. Our network corresponds to a modified version of PWC-Net which achieves high performance on ultrasound sequences. In parallel, we designed a novel simulation pipeline allowing the generation of a large amount of realistic B-mode sequences. These synthetic data, together with strategies during training and inference, were used to improve the performance of our deep learning solution, which achieved an average endpoint error of 0.07 ± 0.06 mm per frame and 1.20 ± 0.67 mm between ED and ES on our simulated dataset. The performance of our method was further investigated on 30 patients from a publicly available clinical dataset acquired from a GE system. The method showed promise by achieving a mean absolute error of the global longitudinal strain of 2.5 ± 2.1% and a correlation of 0.77 compared to GLS derived from manual segmentation, much better than one of the most efficient methods in the state-of-the-art (namely the FFT-Xcorr block-matching method). We finally evaluated our method on an auxiliary dataset including 30 patients from another center and acquired with a different system. Comparable results were achieved, illustrating the ability of our method to maintain high performance regardless of the echocardiographic data processed.