Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Opt Express ; 32(1): 987-1002, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38175118

RESUMO

In this paper, an end-to-end methane gas detection algorithm based on transformer and multi-layer perceptron (MLP) for tunable diode laser absorption spectroscopy (TDLAS) is presented. It consists of a Transformer-based U-shaped Neural Network (TUNN) filtering algorithm and a concentration prediction network (CPN) based on MLP. This algorithm employs an end-to-end architectural design to extract information from noisy transmission spectra of methane and derive the CH4 concentrations from denoised spectra, without intermediate steps. The results demonstrate the superiority of the proposed TUNN filtering algorithm over other typically employed digital filters. For concentration prediction, the determination coefficient (R2) reached 99.7%. Even at low concentrations, R2 remained notably high, reaching up to 89%. The proposed algorithm results in a more efficient, convenient, and accurate spectral data processing for TDLAS-based gas sensors.

2.
Opt Lett ; 48(3): 562-565, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36723531

RESUMO

In this Letter, a side-excitation light-induced thermoelastic spectroscopy (SE-LITES) technique was developed for trace gas detection. A novel, to the best of our knowledge, custom quartz tuning fork (QTF) was used as a transducer for photon detection by the thermoelastic effect. The mechanical stress distribution on the QTF surface was analyzed to identify the optimum thermoelastic excitation approach. The electrode film on the QTF surface also works as a partially reflective layer to obtain a long optical absorption path inside the QTF body. With the long optical absorption length and the inner face excitation of the QTF, the thermoelastic effect was greatly enhanced. With an optimized modulation depth, a signal-to-noise ratio (SNR) improvement of more than one order of magnitude was achieved, compared to traditional LITES.

3.
Opt Lett ; 47(17): 4556-4559, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36048703

RESUMO

In this Letter, clamp-type quartz tuning fork enhanced photoacoustic spectroscopy (Clamp-type QEPAS) is proposed and realized through the design, realization, and testing of clamp-type quartz tuning forks (QTFs) for photoacoustic gas sensing. The clamp-type QTF provides a wavefront-shaped aperture with a diameter up to 1 mm, while keeping Q factors > 104. This novel, to the best of our knowledge, design results in a more than ten times increase in the area available for laser beam focusing for the QEPAS technique with respect to a standard QTF. The wavefront-shaped clamp-type prongs effectively improve the acoustic wave coupling efficiency. The possibility to implement a micro-resonator system for clamp-type QTF is also investigated. A signal-to-noise enhancement of ∼30 times has been obtained with a single-tube acoustic micro resonator length of 8 mm, ∼20% shorter than the dual-tube micro-resonator employed in a conventional QEPAS system.


Assuntos
Quartzo , Quartzo/química , Análise Espectral/métodos
4.
Molecules ; 27(19)2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36235042

RESUMO

A photoacoustic detection module based on a gold-plated photoacoustic cell was reported in this manuscript to measure hydrogen sulfide (H2S) gas in sewers. A 1582 nm distributed feedback (DFB) diode laser was employed as the excitation light source of the photoacoustic sensor. Operating pressure within the photoacoustic cell and laser modulation depth were optimized at room temperature, and the long-term stability of the photoacoustic sensor system was analyzed by an Allan-Werle deviation analysis. Experimental results showed that under atmospheric pressure and room temperature conditions, the photoacoustic detection module exhibits a sensitivity of 11.39 µV/ppm of H2S and can reach a minimum detection limit (1σ) of 140 ppb of H2S with an integration time of 1 s. The sensor was tested for in-field measurements by sampling gas in the sewer near the Shanxi University canteen: levels of H2S of 81.5 ppm were measured, below the 100 ppm limit reported by the Chinese sewer bidding document.


Assuntos
Sulfeto de Hidrogênio , Érbio , Ouro , Humanos , Sulfeto de Hidrogênio/análise , Lasers Semicondutores , Análise Espectral/métodos
5.
Opt Express ; 29(16): 25100-25108, 2021 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-34614848

RESUMO

In this paper, we report on an ultra-highly sensitive light-induced thermoelastic spectroscopy (LITES)-based carbon monoxide (CO) sensor exploiting custom quartz tuning forks (QTFs) as a photodetector, a multi-pass cell and a mid-infrared quantum cascade laser (QCL) for the first time. The QCL emitting at 4.58 µm with output power of 145 mW was employed as exciting source and the multi-pass cell was employed to increase the gas absorption pathlength. To reduce the noise level, wavelength modulation spectroscopy (WMS) and second harmonic demodulation techniques were exploited. Three QTFs including two custom QTFs (#1 and #2) with different geometries and a commercial standard QTF (#3) were tested as photodetector in the gas sensor. When the integration time of the system was set at 200 ms, minimum detection limits (MDLs) of 750 part-per-trillion (ppt), 4.6 part-per-billion (ppb) and 5.8 ppb were achieved employing QTF #1 #2, and #3, respectively. A full sensor calibration was achieved using the most sensitive QTF#1, demonstrating an excellent linear response with CO concentration.

6.
Opt Lett ; 46(5): 977-980, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33649635

RESUMO

A multi-pass quartz-enhanced photoacoustic spectroscopy (MP-QEPAS)-based trace gas sensor is reported. In MP-QEPAS, a multi-pass laser beam pattern through the prong spacing of a quartz tuning fork (QTF) is obtained by means of two right-angle prisms. A large QTF with the prong length of 17 mm and prong spacing of 0.8 mm was employed to increase the passage of multi-pass time and ease the alignment of the beam reflection pattern through the QTF. This multi-pass configuration allows the laser beam to pass through the QTF prong spacing six times. Water vapor (H2O) was chosen as target gas to investigate the performance of the MP-QEPAS sensor. Compared to a conventional QEPAS measurement, the MP-QEPAS technique provided an enhancement of signal level of ∼3.2 times.

7.
Anal Chem ; 92(16): 11035-11043, 2020 08 18.
Artigo em Inglês | MEDLINE | ID: mdl-32674566

RESUMO

We report on a statistical tool based on partial least-squares regression (PLSR) able to retrieve single-component concentrations in a multiple-gas mixture characterized by spectrally overlapping absorption features. Absorption spectra of mixtures of CO-N2O and mixtures of C2H2-CH4-N2O, both diluted in N2, were detected in the mid-IR range by exploiting quartz-enhanced photoacoustic spectroscopy (QEPAS) and using two quantum cascade lasers as light sources. Single-gas reference spectra of each target molecule were acquired and used as PLSR-based algorithm training data set. The concentration range explored in the analysis varies from a few parts-per-million (ppm) to thousands of ppm. Within this concentration range, the influence of the gas matrix on nonradiative relaxation processes can be neglected. Exploiting the ability of PLSR to deal with correlated data, these spectra were used to generate new simulated spectra, i.e., linear combinations of the reference ones. A Gaussian noise distribution was added to the created data set, simulating the real QEPAS signal fluctuations around the peak value. Compared with standard multilinear regression, PLSR predicted gas concentrations with a calibration error up to 5 times better, even with absorption features with spectral overlap greater than 97%.

8.
Opt Express ; 28(13): 19074-19084, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32672192

RESUMO

We report on a study of light-induced thermo-elastic effects occurring in quartz tuning forks (QTFs) when exploited as near-infrared light detectors in a tunable diode laser absorption spectroscopy sensor setup. Our analysis showed that when the residual laser beam transmitted by the absorption cell is focused on the QTF surface area where the maximum strain field occurs, the QTF signal-to-noise ratio (SNR) is proportional to the strain itself and to the QTF accumulation time. The SNR was also evaluated when the pressure surrounding the QTF was lowered from 700 Torr to 5 Torr, resulting in an enhancement factor of ∽4 at the lowest pressure. At 5 torr, the QTF employed as light detector showed an SNR ∽6.5 times higher than that obtained by using a commercially available amplified photodetector.

9.
Opt Express ; 28(13): 19446-19456, 2020 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-32672221

RESUMO

An ultra-highly sensitive and robust CH4 sensor is reported based on a 3.3 µm interband cascade laser (ICL) and a low-noise differential photoacoustic (PAS) cell. The ICL emission wavelength targeted a fundamental absorption line of CH4 at 2988.795 cm-1 with an intensity of 1.08 × 10-19 cm/molecule. The double-pass and differential design of the PAS cell effectively enhanced the PAS signal amplitude and decreased its background noise. The wavelength modulation depth, operating pressure and V-T relaxation promotion were optimized to maximize the sensor detection limit. With an integration time of 90 s, a detection limit of 0.6 ppb was achieved. No additional water or air laser cooling were required and thereby allowing the realization of a compact and robust CH4 sensor.

10.
Sensors (Basel) ; 20(10)2020 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-32455887

RESUMO

A dual-gas sensor based on the combination of a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor and an electronic hygrometer was realized for the simultaneous detection of methane (CH4) and water vapor (H2O) in air. The QEPAS sensor employed an interband cascade laser operating at 3.34 µm capable of targeting a CH4 absorption line at 2988.8 cm-1 and a water line at 2988.6 cm-1. Water vapor was measured with both the electronic hygrometer and the QEPAS sensor for comparison. The measurement accuracy provided by the hygrometer enabled the adjustment of methane QEPAS signal with respect to the water vapor concentration to retrieve the actual CH4 concentration. The sensor was tested by performing prolonged measurements of CH4 and H2O over 60 h to demonstrate the effectiveness of this approach for environmental monitoring applications.

11.
Molecules ; 25(23)2020 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-33260601

RESUMO

We report on a fiber-coupled, quartz-enhanced photoacoustic spectroscopy (QEPAS) near-IR sensor for sequential detection of methane (CH4 or C1) and ethane (C2H6 or C2) in air. With the aim of developing a lightweight, compact, low-power-consumption sensor suitable for unmanned aerial vehicles (UAVs)-empowered environmental monitoring, an all-fiber configuration was designed and realized. Two laser diodes emitting at 1653.7 nm and 1684 nm for CH4 and C2H6 detection, respectively, were fiber-combined and fiber-coupled to the collimator port of the acoustic detection module. No cross talk between methane and ethane QEPAS signal was observed, and the related peak signals were well resolved. The QEPAS sensor was calibrated using gas samples generated from certified concentrations of 1% CH4 in N2 and 1% C2H6 in N2. At a lock-in integration time of 100 ms, minimum detection limits of 0.76 ppm and 34 ppm for methane and ethane were achieved, respectively. The relaxation rate of CH4 in standard air has been investigated considering the effects of H2O, N2 and O2 molecules. No influence on the CH4 QEPAS signal is expected when the water vapor concentration level present in air varies in the range 0.6-3%.


Assuntos
Monitoramento Ambiental/métodos , Etano/análise , Metano/análise , Técnicas Fotoacústicas/métodos , Quartzo/química , Espectroscopia de Luz Próxima ao Infravermelho/métodos
12.
Anal Chem ; 91(9): 5834-5840, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-30994331

RESUMO

A compact and sensitive carbon monoxide (CO) sensor was demonstrated by using quartz enhanced photoacoustic spectroscopy (QEPAS) exploiting a novel 15.2 kHz quartz tuning fork (QTF) with grooved surfaces. The custom QTF was designed to provide a quality factor as high as 15 000 at atmospheric pressure, which offers a high detection sensitivity. A large QTF prong spacing of 800 µm was selected, allowing one to avoid the use of any spatial filters when employing a quantum cascade laser as the excitation source. Four rectangular grooves were carved on two prong surfaces of the QTF to decrease the electrical resistance and hence enhance the signal amplitude. With water vapor as the catalyst for vibrational energy transfer, the sensor system using the novel surface grooved QTF achieved a CO minimum detection limit of 7 ppb for a 300 ms averaging time, which corresponds to a normalized noise equivalent absorption coefficient of 8.74 × 10-9 cm-1W /√Hz. Continuous measurements covering a seven-day period for atmospheric CO were implemented to verify the reliability and validity of the developed CO sensor system.


Assuntos
Monóxido de Carbono/análise , Gases/análise , Lasers Semicondutores , Técnicas Fotoacústicas/métodos , Quartzo/química , Limite de Detecção , Técnicas Fotoacústicas/instrumentação , Propriedades de Superfície
13.
Anal Chem ; 91(20): 12866-12873, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31500409

RESUMO

The development of a dual-gas quartz-enhanced photoacoustic (QEPAS) sensor capable of simultaneous detection of water vapor and alternatively methane or nitrous oxide is reported. A diode laser and a quantum cascade laser (QCL) excited independently and simultaneously both the fundamental and the first overtone flexural mode of the quartz tuning fork (QTF), respectively. The diode laser targeted a water absorption line located at 7181.16 cm-1 (1.392 µm), while the QCL emission wavelength is centered at 7.71 µm and was tuned to target two strong absorption lines of methane and nitrous oxide, located at 1297.47 and 1297.05 cm-1, respectively. Two sets of microresonator tubes were positioned, respectively, at the antinode points of the fundamental and the first overtone flexural modes of the QTF to enhance the QEPAS signal-to-noise ratio. Detection limits of 18 ppb for methane, 5 ppb for nitrous oxide and 20 ppm for water vapor have been achieved at a lock-in integration time of 100 ms.

14.
Opt Express ; 27(24): 35267-35278, 2019 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-31878699

RESUMO

A grooved quartz tuning fork (QTF) with a prong spacing of 800 µm for QEPAS application is reported. The prongs spacing is large enough to facilitate optical alignments when a degraded laser beam is used for QEPAS-based trace gas sensors. The grooved QTF has a resonance frequency of 15.2 kHz at atmospheric pressure and is characterized by four rectangular grooves carved on the QTF prong surfaces. With a grooved-prong, the electrical resistance R of the QTF is reduced resulting in an enhanced piezoelectric signal, while the Q factor is not affected, remaining as high as 15000 at atmospheric pressure. The geometric parameters of the acoustic micro resonators (AmRs) for on-beam QEPAS were optimized to match the grooved QTF, and a signal-to-noise gain factor of ∼ 30 was obtained with an optimum configuration. The performance of the QEPAS-based sensor was demonstrated exploiting an interband cascade laser (ICL) for CH4 detection and a 1σ normalized noise equivalent absorption (NNEA) coefficient of 4.1×10-9 cm-1 W/√Hz was obtained at atmospheric pressure.

15.
Opt Express ; 27(2): 1401-1415, 2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30696206

RESUMO

We report on the design, realization, and performance of novel quartz tuning forks (QTFs) optimized for quartz-enhanced photoacoustic spectroscopy (QEPAS). Starting from a QTF geometry designed to provide a fundamental flexural in-plane vibrational mode resonance frequency of ~16 kHz, with a quality factor of 15,000 at atmospheric pressure, two novel geometries have been realized: a QTF with T-shaped prongs and a QTF with prongs having rectangular grooves carved on both surface sides. The QTF with grooves showed the lowest electrical resistance, while the T-shaped prongs QTF provided the best photoacoustic response in terms of signal-to-noise ratio (SNR). When acoustically coupled with a pair of micro-resonator tubes, the T-shaped QTF provides a SNR enhancement of a factor of 60 with respect to the bare QTF, which represents a record value for mid-infrared QEPAS sensing.

16.
Opt Express ; 27(4): 4271-4280, 2019 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-30876044

RESUMO

The design and realization of two highly sensitive and easily interchangeable spectrophones based on custom quartz tuning forks, with a rectangular (S1) or T-shaped (S2) prongs geometry, is reported. The two spectrophones have been implemented in a QEPAS sensor for ethylene detection, employing a DFB-QCL emitting at 10.337 µm with an optical power of 74.2 mW. A comparison between their performances showed a signal-to-noise ratio 3.4 times higher when implementing the S2 spectrophone. For the S2-based sensor, a linear dependence of the QEPAS signal on ethylene concentration was demonstrated in the 5 ppm -100 ppm range. For a 10 s lock-in integration time, an ethylene minimum detection limit of 10 ppb was calculated.

17.
Sensors (Basel) ; 19(19)2019 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-31547566

RESUMO

A theoretical model describing the acoustic coupling between two resonator tubes in spectrophones exploiting custom-made quartz tuning forks (QTFs) is proposed. The model is based on an open-end correction to predict the optimal tube length. A calculation of the sound field distribution from one tube exit allowed for the estimation of the optimal radius as a function of the QTF prong spacing and the sound wavelength. The theoretical predictions have been confirmed using experimental studies employing a custom QTF with a fundamental flexural mode resonance frequency of 15.8 kHz and a quality factor of 15,000 at atmospheric pressure. The spacing between the two prongs was 1.5 mm. Spectrophones mounting this QTF were implemented for the quartz-enhanced photoacoustic detection of water vapor in air in the mid-infrared spectral range.

18.
Sensors (Basel) ; 19(18)2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31487884

RESUMO

A detailed investigation of the influence of quartz tuning forks (QTFs) resonance properties on the performance of quartz-enhanced photoacoustic spectroscopy (QEPAS) exploiting QTFs as acousto-electric transducers is reported. The performance of two commercial QTFs with the same resonance frequency (32.7 KHz) but different geometries and two custom QTFs with lower resonance frequencies (2.9 KHz and 7.2 KHz) were compared and discussed. The results demonstrated that the fundamental resonance frequency as well as the quality factor and the electrical resistance were strongly inter-dependent on the QTF prongs geometry. Even if the resonance frequency was reduced, the quality factor must be kept as high as possible and the electrical resistance as low as possible in order to guarantee high QEPAS performance.

19.
Opt Lett ; 43(8): 1854-1857, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29652382

RESUMO

The design, realization, and performance analysis of an octupole electrode pattern configuration intended for the optimization of the charge collection efficiency in quartz tuning forks (QTFs) vibrating at the first overtone in-plane flexural mode is reported. Two QTFs having the same geometry, but differing in the electrode pattern deposited on the QTF prongs, have been realized in order to study the influence of the electrode pattern on the resonance quality factor and electrical resistance. A standard quadrupole pattern (optimized for the fundamental mode) and an octupole electrode layout have been implemented. Although both QTFs show the same resonance quality factor for the first overtone, the octupole pattern provides a reduction of the QTF electrical resistance by more than four times. The sensing performance of the two QTFs has been compared by employing them in a mid-IR quartz-enhanced photoacoustic sensor (QEPAS) system targeting a water absorption line. When operating at the first overtone mode, the QTF with an octupole electrode pattern provides a QEPAS signal more than two times higher with respect to the QTF employing the standard quadrupole configuration.

20.
Opt Express ; 24(14): 15872-81, 2016 Jul 11.
Artigo em Inglês | MEDLINE | ID: mdl-27410857

RESUMO

The implementation, performance validation, and testing of a gas-leak optical sensor based on mid-IR quartz-enhanced photoacoustic (QEPAS) spectroscopic technique is reported. A QEPAS sensor was integrated in a vacuum-sealed test station for mechatronic components. The laser source for the sensor is a quantum cascade laser emitting at 10.56 µm, resonant with a strong absorption band of sulfur hexafluoride (SF6), which was selected as a leak tracer. The minimum detectable concentration of the QEPAS sensor is 2.7 parts per billion with an integration time of 1 s, corresponding to a sensitivity of leak flows in the 10-9 mbar∙l/s range, comparable with state-of-the-art leak detection techniques.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa