1.
Acta Radiol ; 64(4): 1566-1572, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36373570

RESUMO

BACKGROUND: Bone strength is related to both mineral density (BMD) and the bone microstructure. However, only the assessment of BMD is available in clinical routine care today. PURPOSE: To analyze and study the correlation of trabecular bone microstructure from the imaging data of a prototype Multitom Rax system, using micro-computed tomography (CT) data as the reference method (Skyscan 1176). MATERIAL AND METHODS: Imaging data from 14 bone samples from the human radius were analyzed regarding six bone structure parameters, i.e. trabecular nodes, separation, spacing, and thickness as well as bone volume (BV/TV) and structural model index (SMI). RESULTS: All six structure parameters showed strong correlations to micro-CT with Spearman correlation coefficients in the range of 0.83-0.93. BV/TV and SMI had a correlation >0.90. Two of the parameters, namely, separation and number, had mean values in the same range as micro-CT. The other four were either over- or underestimated. CONCLUSION: The strong correlation between micro-CT and the clinical imaging system, indicates the possibility for analyzing bone microstructure with potential to add value in fracture assessment using the studied device in a clinical workflow.


Assuntos
Osso Esponjoso , Procedimentos Cirúrgicos Robóticos , Humanos , Microtomografia por Raio-X/métodos , Osso Esponjoso/diagnóstico por imagem , Raios X , Osso e Ossos/diagnóstico por imagem , Densidade Óssea
2.
Acta Radiol ; 64(11): 2957-2966, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37735891

RESUMO

BACKGROUND: As guidelines endorse the use of computed tomography (CT) for examining coronary artery disease (CAD), it is important to compare the advantages and disadvantages of the novel photon counting detector CT (PCD-CT) technology with the established energy integrating detector CT (EID-CT). PURPOSE: To compare the image quality of coronary computed tomography angiography (CCTA) and the Agatston scores (AS) derived from EID-CT and PCD-CT. MATERIAL AND METHODS: In this prospective observational study, 28 patients underwent clinical calcium score and CCTA scans on an EID-CT and a PCD-CT scanner. CCTA images were qualitatively analyzed by five observers using visual grading characteristics. The correlation and agreement of the AS were assessed using Spearman's rank correlation and Bland-Altman plots. RESULTS: This qualitative analyses demonstrated a high fraction of "good" or "excellent" ratings for the image criteria in both CT systems. The sharpness of the distal lumen and image quality regarding motion artifacts were rated significantly higher for EID-CT (P < 0.05). However, the sharpness of coronary calcification was rated significantly higher for PCD-CT (P < 0.05). Spearman's rank correlation and Bland-Altman plots showed good correlation (P = 0.95) and agreement regarding the AS between EID-CT and PCD-CT. CONCLUSION: Both CT systems exhibited high CCTA image quality. The sharpness of calcifications was rated significantly higher for PCD-CT. A good correlation was observed between the AS derived from the two systems.


Assuntos
Calcinose , Doença da Artéria Coronariana , Humanos , Angiografia por Tomografia Computadorizada/métodos , Estudos Prospectivos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Doença da Artéria Coronariana/diagnóstico por imagem
3.
J Radiol Prot ; 42(3)2022 07 28.
Artigo em Inglês | MEDLINE | ID: mdl-35728585

RESUMO

Vascular x-ray guided interventions are complex and may result in high occupational doses to ionising radiation if staff do not take appropriate actions to minimise their exposure. In this prospective intervention study, ten staff members wore an extra personal dosimeter on the upper body above their regular protective clothing during four consecutive periods. Between each period either additional practical radiological protection training was given or a real-time direct display dosimeter were provided to the staff. Each staff's personal dose equivalent, Hp(10) normalised to the total air kerma-area product for the procedures where each staff were involved, KAPt, was used as the dependent variable. A focus-group interview with the staff were performed about the usefulness of the training and real-time dose rate display system. Our aim was to investigate if the interventions (practical training or real-time dose rate display) did affect the staff doses in the short and long term (five months later). Significant (p < 0.05) reductions of staff doses Hp(10)/KAPt were found after practical radiological protection training, but not after using real-time dose rate displays. Significant reductions were maintained after five months without additional interventions. The results from the focus-group interview indicated that making radiation 'visible', during practical training and usage of real-time direct display dosimeter, made it easier to understand how to act to lower occupational doses.


Assuntos
Exposição Ocupacional , Dosímetros de Radiação , Angiografia , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Estudos Prospectivos , Doses de Radiação
4.
BMC Med Imaging ; 19(1): 64, 2019 08 09.
Artigo em Inglês | MEDLINE | ID: mdl-31399078

RESUMO

BACKGROUND: Our aim was to compare CT images from native, nephrographic and excretory phases using image quality criteria as well as the detection of positive pathological findings in CT Urography, to explore if the radiation burden to the younger group of patients or patients with negative outcomes can be reduced. METHODS: This is a retrospective study of 40 patients who underwent a CT Urography examination on a 192-slice dual source scanner. Image quality was assessed for four specific renal image criteria from the European guidelines, together with pathological assessment in three categories: renal, other abdominal, and incidental findings without clinical significance. Each phase was assessed individually by three radiologists with varying experience using a graded scale. Certainty scores were derived based on the graded assessments. Statistical analysis was performed using visual grading regression (VGR). The limit for significance was set at p = 0.05. RESULTS: For visual reproduction of the renal parenchyma and renal arteries, the image quality was judged better for the nephrogram phase (p < 0.001), whereas renal pelvis/calyces and proximal ureters were better reproduced in the excretory phase compared to the native phase (p < 0.001). Similarly, significantly higher certainty scores were obtained in the nephrogram phase for renal parenchyma and renal arteries, but in the excretory phase for renal pelvis/calyxes and proximal ureters. Assessment of pathology in the three categories showed no statistically significant differences between the three phases. Certainty scores for assessment of pathology, however, showed a significantly higher certainty for renal pathology when comparing the native phase to nephrogram and excretory phase and a significantly higher score for nephrographic phase but only for incidental findings. CONCLUSION: Visualisation of renal anatomy was as expected with each post-contrast phase showing favourable scores compared to the native phase. No statistically significant differences in the assessment of pathology were found between the three phases. The low-dose CT (LDCT) seems to be sufficient in differentiating between normal and pathological examinations. To reduce the radiation burden in certain patient groups, the LDCT could be considered a suitable alternative as a first line imaging method. However, radiologists should be aware of its limitations.


Assuntos
Rim/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Artéria Renal/diagnóstico por imagem , Urografia/instrumentação , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Rim/irrigação sanguínea , Masculino , Pessoa de Meia-Idade , Tecido Parenquimatoso/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/instrumentação
5.
Eur Radiol ; 28(6): 2464-2473, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29368163

RESUMO

PURPOSE: To estimate potential dose reduction in abdominal CT by visually comparing images reconstructed with filtered back projection (FBP) and strengths of 3 and 5 of a specific MBIR. MATERIAL AND METHODS: A dual-source scanner was used to obtain three data sets each for 50 recruited patients with 30, 70 and 100% tube loads (mean CTDIvol 1.9, 3.4 and 6.2 mGy). Six image criteria were assessed independently by five radiologists. Potential dose reduction was estimated with Visual Grading Regression (VGR). RESULTS: Comparing 30 and 70% tube load, improved image quality was observed as a significant strong effect of log tube load and reconstruction method with potential dose reduction relative to FBP of 22-47% for MBIR strength 3 (p < 0.001). For MBIR strength 5 no dose reduction was possible for image criteria 1 (liver parenchyma), but dose reduction between 34 and 74% was achieved for other criteria. Interobserver reliability showed agreement of 71-76% (κw 0.201-0.286) and intra-observer reliability of 82-96% (κw 0.525-0.783). CONCLUSION: MBIR showed improved image quality compared to FBP with positive correlation between MBIR strength and increasing potential dose reduction for all but one image criterion. KEY POINTS: • MBIR's main advantage is its de-noising properties, which facilitates dose reduction. • MBIR allows for potential dose reduction in relation to FBP. • Visual Grading Regression (VGR) produces direct numerical estimates of potential dose reduction. • MBIR strengths 3 and 5 dose reductions were 22-34 and 34-74%. • MBIR strength 5 demonstrates inferior performance for liver parenchyma.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Protocolos Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Radiografia Abdominal/normas , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/normas , Adulto Jovem
6.
Radiat Prot Dosimetry ; 200(5): 504-514, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38369635

RESUMO

Non-linear properties of iterative reconstruction (IR) algorithms can alter image texture. We evaluated the effect of a model-based IR algorithm (advanced modelled iterative reconstruction; ADMIRE) and dose on computed tomography thorax image quality. Dual-source scanner data were acquired at 20, 45 and 65 reference mAs in 20 patients. Images reconstructed with filtered back projection (FBP) and ADMIRE Strengths 3-5 were assessed independently by six radiologists and analysed using an ordinal logistic regression model. For all image criteria studied, the effects of tube load 20 mAs and all ADMIRE strengths were significant (p < 0.001) when compared to reference categories 65 mAs and FBP. Increase in tube load from 45 to 65 mAs showed image quality improvement in three of six criteria. Replacing FBP with ADMIRE significantly improves perceived image quality for all criteria studied, potentially permitting a dose reduction of almost 70% without loss in image quality.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Tórax/diagnóstico por imagem
7.
Acta Radiol ; 54(2): 226-30, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23138023

RESUMO

BACKGROUND: Optimization of CT radiation dose is important for children due to their higher risk of radiation-induced adverse effects. Anatomical structures with high inherent contrast, such as bones can be imaged at very low radiation doses by optimizing scan parameters. PURPOSE: To assess feasibility of sub-milliSievert whole spine CT scanning protocol for evaluation of scoliosis in children. MATERIAL AND METHODS: With approval of the ethical board, we performed whole spine CT for evaluation of scoliosis in 22 children (age range, 3-18 years; mean age, 13 years; 13 girls, 9 boys) on a 128-slice dual source multidetector-row CT scanner. Lowest possible quality reference mAs value (image quality factor for xy-z automatic exposure control or xyz-AEC, CARE Dose 4D) was selected on a per patient basis. Remaining parameters were held constant at 3.0:1 pitch, 128 × 0.6 mm detector collimation, 115.2 mm table feed per gantry rotation, 100 kVp, and 1 and 3 mm reconstructed sections. Average mAs, projected estimated dose savings with AEC, computed tomography dose index volume (CTDI vol), and dose length product (DLP) were recorded. Artifacts were graded on a four-point scale (1, no artifacts; 4, severe artifacts). Ability to identify vertebral and pedicular contours, and measure pedicular width and degree of vertebral rotation was graded on a three-point scale (1, unacceptable; 3, excellent). RESULTS: All CT examinations were deemed as reliable for identifying vertebral and pedicular contours as well as for measuring pedicular width (5.9 ± 1.6 mm) and degree of vertebral rotation (28.7 ± 23.4°). Mean objective image noise and signal to noise ratio (SNR) were 57.5 ± 21.5 and 4.7 ± 2.3, respectively. With a mean quality reference mAs of 13, the scanner employed an average actual effective mAs of 10 ± 3.8 (range, 6-18 mAs) with an estimated radiation dose saving of 43.5 ± 16.3% with xyz-AEC compared with fixed mAs. The mean CTDI, DLP, and estimated effective doses were 0.4 ± 0.1 mGy (0.2-0.7 mGy), 21 ± 10 mGy.cm (8-41 mGy.cm), and 0.3 ± 0.1 mSv (0.12-0.64 mSv), respectively. CONCLUSION: Radiation dose for whole spine CT for evaluation of scoliosis in children can be minimized to less than one-third of a milliSievert while maintaining diagnostic image quality.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Doses de Radiação , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Adolescente , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Cifose/diagnóstico por imagem , Masculino
8.
Eur J Radiol Open ; 10: 100490, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37207049

RESUMO

Objectives: Images reconstructed with higher strengths of iterative reconstruction algorithms may impair radiologists' subjective perception and diagnostic performance due to changes in the amplitude of different spatial frequencies of noise. The aim of the present study was to ascertain if radiologists can learn to adapt to the unusual appearance of images produced by higher strengths of Advanced modeled iterative reconstruction algorithm (ADMIRE). Methods: Two previously published studies evaluated the performance of ADMIRE in non-contrast and contrast-enhanced abdominal CT. Images from 25 (first material) and 50 (second material) patients, were reconstructed with ADMIRE strengths 3, 5 (AD3, AD5) and filtered back projection (FBP). Radiologists assessed the images using image criteria from the European guidelines for quality criteria in CT. To ascertain if there was a learning effect, new analyses of data from the two studies was performed by introducing a time variable in the mixed-effects ordinal logistic regression model. Results: In both materials, a significant negative attitude to ADMIRE 5 at the beginning of the viewing was strengthened during the progress of the reviews for both liver parenchyma (first material: -0.70, p < 0.01, second material: -0.96, p < 0.001) and overall image quality (first material:-0.59, p < 0.05, second material::-1.26, p < 0.001). For ADMIRE 3, an early positive attitude for the algorithm was noted, with no significant change over time for all criteria except one (overall image quality), where a significant negative trend over time (-1.08, p < 0.001) was seen in the second material. Conclusions: With progression of reviews in both materials, an increasing dislike for ADMIRE 5 images was apparent for two image criteria. In this time perspective (weeks or months), no learning effect towards accepting the algorithm could be demonstrated.

9.
Brachytherapy ; 22(3): 407-415, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36739222

RESUMO

PURPOSE: The aim was to evaluate a postprocessing optimization algorithm's ability to improve the spatial properties of a clinical treatment plan while preserving the target coverage and the dose to the organs at risk. The goal was to obtain a more homogenous treatment plan, minimizing the need for manual adjustments after inverse treatment planning. MATERIALS AND METHODS: The study included 25 previously treated prostate cancer patients. The treatment plans were evaluated on dose-volume histogram parameters established clinical and quantitative measures of the high dose volumes. The volumes of the four largest hot spots were compared and complemented with a human observer study with visual grading by eight oncologists. Statistical analysis was done using ordinal logistic regression. Weighted kappa and Fleiss' kappa were used to evaluate intra- and interobserver reliability. RESULTS: The quantitative analysis showed that there was no change in planning target volume (PTV) coverage and dose to the rectum. There were significant improvements for the adjusted treatment plan in: V150% and V200% for PTV, dose to urethra, conformal index, and dose nonhomogeneity ratio. The three largest hot spots for the adjusted treatment plan were significantly smaller compared to the clinical treatment plan. The observers preferred the adjusted treatment plan in 132 cases and the clinical in 83 cases. The observers preferred the adjusted treatment plan on homogeneity and organs at risk but preferred the clinical plan on PTV coverage. CONCLUSIONS: Quantitative analysis showed that the postadjustment optimization tool could improve the spatial properties of the treatment plans while maintaining the target coverage.


Assuntos
Braquiterapia , Neoplasias da Próstata , Masculino , Humanos , Dosagem Radioterapêutica , Próstata , Braquiterapia/métodos , Planejamento da Radioterapia Assistida por Computador , Reprodutibilidade dos Testes , Neoplasias da Próstata/radioterapia
10.
Acta Radiol ; 53(3): 335-42, 2012 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-22362136

RESUMO

BACKGROUND: Abdominal computed tomography (CT) is a frequently performed imaging procedure, resulting in considerable radiation doses to the patient population. Postprocessing filters are one of several dose reduction measures that might help to reduce radiation doses without loss of image quality. PURPOSE: To assess and compare the effect of two- and three-dimensional (2D, 3D) non-linear adaptive filters on reduced dose abdominal CT images. MATERIAL AND METHODS: Two baseline abdominal CT image series with a volume computer tomography dose index (CTDI (vol)) of 12 mGy and 6 mGy were acquired for 12 patients. Reduced dose images were postprocessed with 2D and 3D filters. Six radiologists performed blinded randomized, side-by-side image quality assessments. Objective noise was measured. Data were analyzed using visual grading regression and mixed linear models. RESULTS: All image quality criteria were rated as superior for 3D filtered images compared to reduced dose baseline and 2D filtered images (P < 0.01). Standard dose images had better image quality than reduced dose 3D filtered images (P < 0.01), but similar image noise. For patients with body mass index (BMI) < 30 kg/m(2) however, 3D filtered images were rated significantly better than normal dose images for two image criteria (P < 0.05), while no significant difference was found for the remaining three image criteria (P > 0.05). There were no significant variations of objective noise between standard dose and 2D or 3D filtered images. CONCLUSION: The quality of 3D filtered reduced dose abdominal CT images is superior compared to reduced dose unfiltered and 2D filtered images. For patients with BMI < 30 kg/m(2), 3D filtered images are comparable to standard dose images.


Assuntos
Imageamento Tridimensional/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carga Corporal (Radioterapia) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Doses de Radiação , Método Simples-Cego
11.
Radiat Prot Dosimetry ; 198(5): 265-273, 2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35348761

RESUMO

X-ray-guided interventions have increased in number and complexity. Mandatory radiological protection training includes both theoretical and practical training sessions. A recent additional training tool is real-time display dosemeters that give direct feedback to staff on their individual dose rates. Ten staff members who regularly perform pulmonary bronchoscopy wore an extra dosemeter during four 2-month periods. We controlled for the patient air kerma area product and the number of procedures in each period. Between periods 1 and 2, radiological training sessions were held and during period 3 the staff used the real-time display system. Focus-group interviews with the staff were held to obtain their opinion about learning radiological protection. We hypothesised that neither training nor the additional real-time dose rate display alters the personal dose equivalent, Hp(d); d = 0.07 and 10 mm. Useful experiences from radiological protection training were obtained, and median staff doses did decrease, however not significantly.


Assuntos
Exposição Ocupacional , Proteção Radiológica , Broncoscopia , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Doses de Radiação , Proteção Radiológica/métodos , Raios X
12.
Catheter Cardiovasc Interv ; 77(2): 272-5, 2011 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-20824753

RESUMO

OBJECTIVES: We have developed a method using transthoracic echocardiography in establishing optimal visualization of the aortic root, to reduce the amount of contrast medium used in each patient. BACKGROUND: During transcatheter aortic valve implantation, it is necessary to obtain an optimal fluoroscopic projection for deployment of the valve showing the aortic ostium with the three cusps aligned in the beam direction. This may require repeat aortic root angiograms at this stage of the procedure with a high amount of contrast medium with a risk of detrimental influence on renal function. METHODS: We studied the conventional way and an echo guided way to optimize visualisation of the aortic root. Echocardiography was used initially allowing easier alignment of the image intensifier with the transducer's direction. RESULTS: Contrast volumes, radiation/fluoroscopy exposure times, and postoperative creatinine levels were significantly less in patients having the echo-guided orientation of the optimal fluoroscopic angles compared with patients treated with the conventional approach. CONCLUSION: We present a user-friendly echo-guided method to facilitate fluoroscopy adjustment during transcatheter aortic valve implantation. In our series, the amounts of contrast medium and radiation have been significantly reduced, with a concomitant reduction in detrimental effects on renal function in the early postoperative phase.


Assuntos
Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco , Meios de Contraste , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Radiografia Intervencionista , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Cateterismo Cardíaco/instrumentação , Meios de Contraste/efeitos adversos , Creatinina/sangue , Feminino , Fluoroscopia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Nefropatias/sangue , Nefropatias/induzido quimicamente , Masculino , Pessoa de Meia-Idade , Radiografia Intervencionista/efeitos adversos , Medição de Risco , Resultado do Tratamento , Ultrassonografia
13.
Acta Radiol ; 52(7): 716-22, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21852437

RESUMO

BACKGROUND: Computed tomography (CT) is becoming increasingly popular as a non-invasive method for visualizing the coronary arteries but patient radiation doses are still an issue. Postprocessing filters such as 2D adaptive non-linear filters might help to reduce the dose without loss of image quality. PURPOSE: To investigate whether the use of a 2D, non-linear adaptive noise reduction filter can improve image quality in cardiac computed tomography angiography (CCTA). MATERIAL AND METHODS: CCTA examinations were performed in 36 clinical patients on a dual source CT using two patient dose levels: maximum dose during diastole and reduced dose (20% of maximum dose) during systole. One full-dose and one reduced-dose image were selected from each of the examinations. The reduced-dose image was duplicated and one copy postprocessed using a 2D non-linear adaptive noise reduction filter, resulting in three images per patient. Image quality was assessed using visual grading with three criteria from the European guidelines for assessment of image quality and two additional criteria regarding the left main artery and the overall image quality. Also, the HU value and its standard deviation were measured in the ascending and descending aorta. Data were analyzed using Visual Grading Regression and paired t-test. RESULT: For all five criteria, there was a significant (P < 0.01 or better) improvement in perceived image quality when comparing postprocessed low-dose images with low-dose images without noise reduction. Comparing full dose images with postprocessed low-dose images resulted in a considerably larger, significant (P < 0.001) difference. Also, there was a significant reduction of the standard deviation of the HU values in the ascending and descending aorta when comparing postprocessed low-dose images with low-dose images without postprocessing. CONCLUSION: Even with an 80% dose reduction, there was a significant improvement in the perceived image quality when using a 2D noise-reduction filter, though not approaching the quality of full-dose images. This indicates that cardiac CT examinations could benefit from noise-reducing postprocessing with 2D non-linear adaptive filters.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Curva ROC , Doses de Radiação
14.
Radiat Prot Dosimetry ; 195(3-4): 407-415, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33517437

RESUMO

Visibility of low-contrast details in fluoroscopy and interventional radiology is important. Assessing detail visibility with human observers typically suffers from large observer variances. Objective, quantitative measurement of low-contrast detail visibility using a model observer, such as the square of the signal-to-noise ratio rate (SNR2rate), was implemented in MATLAB™ and evaluated. The expected linear response of SNR2rate based on predictions by the so-called Rose model and frame statistics was verified. The uncertainty in the measurement of SNR2rate for a fixed imaging geometry was 6% based on 16 repeated measurements. The results show that, as expected, reduced object thickness and x-ray field size substantially improved SNR2rate/PKA,rate with PKA,rate being the air kerma area product rate. The measurement precision in SNR2rate/PKA,rate (8-9%) is sufficient to detect small but important improvements, may guide the selection of better imaging settings and provides a tool for teaching good radiological imaging techniques to clinical staff.


Assuntos
Radiologia Intervencionista , Fluoroscopia , Humanos , Imagens de Fantasmas , Controle de Qualidade , Razão Sinal-Ruído
15.
J Contemp Brachytherapy ; 13(1): 59-71, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34025738

RESUMO

PURPOSE: High dose-rate prostate brachytherapy has been implemented in Sweden in the late 1980s and early 1990s in six clinics using the same schedule: 20 Gy in two fractions combined with 50 Gy in 25 fractions with external beam radiation therapy. Thirty years have passed and during these years, various aspects of the treatment process have developed, such as ultrasound-guided imaging and treatment planning system. An audit was conducted, including a questionnaire and treatment planning, which aimed to gather knowledge about treatment planning methods in Swedish clinics. MATERIAL AND METHODS: A questionnaire and a treatment planning case (non-anatomical images) were sent to six Swedish clinics, in which high-dose-rate prostate brachytherapy is performed. Treatment plans were compared using dosimetric indices and equivalent 2 Gy doses (EQD2). Treatment planning system report was used to compare dwell positions and dwell times. RESULTS: For all the clinics, the planning aim for the target was 10.0 Gy, but the volume to receive the dose differed from 95% to 100%. Dose constraints for organs at risk varied with up to 2 Gy. The dose to 90% of target volume ranged from 10.0 Gy to 11.1 Gy, equivalent to 26.0 Gy EQD2 and 31.3 Gy EQD2, respectively. Dose non-homogeneity ratio differed from 0.18 to 0.32 for clinical target volume (CTV) in treatment plans and conformity index ranged from 0.52 to 0.59 for CTV. CONCLUSIONS: Dose constraints for the organs at risk are showing a larger variation than that reflected in compared treatments plans. In all treatment plans in our audit, at least 10 Gy was administered giving a total treatment of 102 Gy EQD2, which is in the upper part of the prescription doses published in the GEC/ESTRO recommendations.

16.
Radiat Prot Dosimetry ; 195(3-4): 212-217, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34265847

RESUMO

Dual-energy computed tomography (CT) can be used in radiotherapy treatment planning for the calculation of absorbed dose distributions. The aim of this work is to evaluate whether there is room for improvement in the accuracy of the Monoenergetic Plus algorithm by Siemens Healthineers. A Siemens SOMATOM Force scanner was used to scan a cylindrical polymethyl methacrylate phantom with four rod-inserts made of different materials. Images were reconstructed using ADMIRE and processed with Monoenergetic Plus. The resulting CT numbers were compared with tabulated values and values simulated by the proof-of-a-concept algorithm DIRA developed by the authors. Both the Monoenergetic Plus and DIRA algorithms performed well; the accuracy of attenuation coefficients was better than about ±1% at the energy of 70 keV. Compared with DIRA, the worse performance of Monoenergetic Plus was caused by its (i) two-material decomposition to iodine and water and (ii) imperfect suppression of the beam hardening artifact in ADMIRE.


Assuntos
Iodo , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Algoritmos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
17.
Radiat Prot Dosimetry ; 195(3-4): 218-224, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34240219

RESUMO

The choice of the material base to which the material decomposition is performed in dual-energy computed tomography may affect the quality of reconstructed images. The aim of this work is to investigate how the commonly used bases (water, bone), (water, iodine) and (photoelectric effect, Compton scattering) affect the reconstructed linear attenuation coefficient in the case of the Alvarez-Macovski method. The performance of this method is also compared with the performance of the Dual-energy Iterative Reconstruction Algorithm (DIRA). In both cases, the study is performed using simulations. The results show that the Alvarez-Macovski method produced artefacts when iodine was present in the phantom together with human tissues since this method can only work with one doublet. It was shown that these artefacts could be avoided with DIRA using the (water, bone) doublet for tissues and the (water, iodine) doublet for the iodine solution.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Humanos , Imagens de Fantasmas
18.
Radiat Prot Dosimetry ; 195(3-4): 172-176, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-34037238

RESUMO

Automatic segmentation of bones in computed tomography (CT) images is used for instance in beam hardening correction algorithms where it improves the accuracy of resulting CT numbers. Of special interest are pelvic bones, which-because of their strong attenuation-affect the accuracy of brachytherapy in this region. This work evaluated the performance of the JJ2016 algorithm with the performance of MK2014v2 and JS2018 algorithms; all these algorithms were developed by authors. Visual comparison, and, in the latter case, also Dice similarity coefficients derived from the ground truth were used. It was found that the 3D-based JJ2016 performed better than the 2D-based MK2014v2, mainly because of the more accurate hole filling that benefitted from information in adjacent slices. The neural network-based JS2018 outperformed both traditional algorithms. It was, however, limited to the resolution of 1283 owing to the limited amount of memory in the graphical processing unit (GPU).


Assuntos
Ossos Pélvicos , Tomografia Computadorizada por Raios X , Algoritmos , Processamento de Imagem Assistida por Computador , Aprendizado de Máquina , Redes Neurais de Computação , Pelve/diagnóstico por imagem
19.
Radiat Prot Dosimetry ; 195(3-4): 257-263, 2021 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-33709133

RESUMO

Skin injuries may occur when radiation doses to the skin exceed 2 Gy. This study aimed to measure changes in skin microcirculation in patients undergoing chronic total occlusion percutaneous coronary interventions (CTO-PCI). In 14 patients, peak skin dose (PSD) was estimated with radiographic films and skin microcirculation was assessed with laser speckle contrast imaging (LSCI), before, 1 day after the intervention, and 4-6 weeks later. The mean PSD was 1.8 ± 0.9 Gy. Peak skin microcirculation increased by 12% from 45 ± 6 PU before to 50 ± 9 PU 1 day after the intervention (p = 0.01), and returned to 46 ± 8 PU after 4-6 weeks (p = 0.15). There was no significant correlation between PSD and the change in perfusion, neither 1 day (r = -0.13, p = 0.69) nor 4-6 weeks after the intervention (r = 0.33, p = 0.35). These results suggest that there are no radiation-induced microvascular changes in the skin after CTO-PCI at skin doses below 2 Gy.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Microcirculação , Intervenção Coronária Percutânea/efeitos adversos , Pele
20.
Eur Radiol ; 20(3): 725-33, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19727739

RESUMO

PURPOSE: To assess patient skin and eye lens doses in interventional neuroradiology and to assess both stochastic and deterministic radiation risks. METHODS: Kerma-area product (P (KA)) was recorded and skin doses measured using thermoluminescence dosimeters. Estimated dose at interventional reference point (IRP) was compared with measured absorbed doses. RESULTS: The average and maximum fluoroscopy times were 32 and 189 min for coiling and 40 and 144 min for embolisation. The average and maximum P (KA) for coiling were 121 and 436 Gy cm(2), respectively, and 189 and 677 Gy cm(2) for embolisation. The average and maximum values of the measured maximum absorbed skin doses were 0.72 and 3.0 Sv, respectively, for coiling and 0.79 and 2.1 Sv for embolisation. Two out of the 52 patients received skin doses in excess of 2 Sv. The average and maximum doses to the eye lens (left eye) were 51 and 515 mSv (coiling) and 71 and 289 mSv (embolisation). CONCLUSION: The ratio between the measured dose and the dose at the IRP was 0.44 +/- 0.18 mSv/mGy indicating that the dose displayed by the x-ray unit overestimates the maximum skin dose but is still a valuable indication of the dose. The risk of inducing skin erythema and lens cataract during our hospital procedures is therefore small.


Assuntos
Angiografia Cerebral , Cristalino/fisiologia , Neurorradiografia , Doses de Radiação , Radiografia Intervencionista , Radiometria , Fenômenos Fisiológicos da Pele , Humanos , Eficiência Biológica Relativa