Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Card Surg ; 37(12): 4459-4464, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36229968

RESUMO

PURPOSE: To evaluate the clinical and surgical outcomes among children with bicuspid aortic valve who underwent cardiac surgery. METHODS: This observational and retrospective study included patients with a diagnosis of bicuspid aortic valve who underwent cardiac surgery between January 1, 2003, and March 31, 2020. Demographic characteristics and perioperative conditions were described. RESULTS: One hundred and sixteen patients were included, with a mean age of 12.4 ± 4.2 years; 63.2% were male. The most frequent diagnosis was congenital aortic stenosis (23.5%), followed by connective tissue disorders (16%). Mechanical aortic prostheses were used in 87.7% of cases, with a mean size of 21 ± 2.6 mm. The main factors associated with mortality were valve prosthesis dysfunction (odds ratio [OR]: 12.44; 95% confidence interval [CI]: 1.05-147.48; p = .04) and reoperation (OR: 24.29; 95% CI: 1.03-570.08; p = .04). The overall survival was 87.9%, with better outcomes among those who did not undergo reoperation (Log Rank, p = .01). CONCLUSIONS: Outcomes after aortic valve replacement in children with bicuspid aortic valve are excellent in the short and long term, regardless of using mechanical or biological prostheses.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Criança , Adolescente , Feminino , Doença da Válvula Aórtica Bicúspide/cirurgia , Estudos Retrospectivos , México/epidemiologia , Valva Aórtica/anormalidades , Estenose da Valva Aórtica/cirurgia , Reoperação , Resultado do Tratamento
2.
Biophys J ; 120(8): 1443-1453, 2021 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-33607085

RESUMO

Microchannels can be used to simulate xylem vessels and investigate phytopathogen colonization under controlled conditions. In this work, we explore surface functionalization strategies for polydimethylsiloxane and glass microchannels to study microenvironment colonization by Xylella fastidiosa subsp. pauca cells. We closely monitored cell initial adhesion, growth, and motility inside microfluidic channels as a function of chemical environments that mimic those found in xylem vessels. Carboxymethylcellulose (CMC), a synthetic cellulose, and an adhesin that is overexpressed during early stages of X. fastidiosa biofilm formation, XadA1 protein, were immobilized on the device's internal surfaces. This latter protocol increased bacterial density as compared with CMC. We quantitatively evaluated the different X. fastidiosa attachment affinities to each type of microchannel surface using a mathematical model and experimental observations acquired under constant flow of culture medium. We thus estimate that bacterial cells present ∼4 and 82% better adhesion rates in CMC- and XadA1-functionalized channels, respectively. Furthermore, variable flow experiments show that bacterial adhesion forces against shear stresses approximately doubled in value for the XadA1-functionalized microchannel as compared with the polydimethylsiloxane and glass pristine channels. These results show the viability of functionalized microchannels to mimic xylem vessels and corroborate the important role of chemical environments, and particularly XadA1 adhesin, for early stages of X. fastidiosa biofilm formation, as well as adhesivity modulation along the pathogen life cycle.


Assuntos
Biofilmes , Xylella , Aderência Bacteriana , Adesão Celular , Xilema
3.
J Card Surg ; 36(12): 4476-4484, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34494321

RESUMO

PURPOSE: The aim of the study was to identify, determine, and analyze the clinical and surgical outcomes of patients with atrial isomerism (AI) undergoing cardiac surgery. METHODS: A retrospective study was carried out. Patients with diagnosis of AI undergoing cardiac surgery at the National Institute of Cardiology Ignacio Chávez, from January 1, 2010 and March 31, 2020 were included; demographic characteristics and perioperative conditions of the patients were considered. RESULTS: Sixty-five patients were included, with an average age of 6.4 ± 4.9 years, 50.8% males. Thirty-eight (58.5%) had right atrial isomerism (RAI) and 27 (41.5%) had left atrial isomerism (LAI); univentricular physiology (78.5%) predominated. Atrioventricular septal defect (AVSD) in RAI and septal defects in LAI were identified as the main associated defects. The most common surgical procedures performed were modified Blalock-Taussig shunt (MBTS) (27.6%), MBTS with total anomalous pulmonary venous connection (TAPVC) repair (15.3%) and total cavopulmonary connection (TCPC) with an extracardiac conduit fenestrated (10.8%); 100% RAI required a univentricular approach, while in LAI it was 48.1%. Overall survival was 92.3%, with 100% survival in LAI with biventricular physiology and 86.8% in RAI with univentricular physiology. CONCLUSIONS: The survival of our institution is similar to that of other referral centers, where patients with LAI had a better evolution than RAI; in addition, the univentricular approach was required in all with RAI. Patients with AI must undergo a rigorous evaluation to determine an adequate repair strategy, considering univentricular RAI with a high possibility of morbidity and mortality.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Defeitos dos Septos Cardíacos , Síndrome de Heterotaxia , Criança , Pré-Escolar , Feminino , Síndrome de Heterotaxia/cirurgia , Humanos , Lactente , Isomerismo , Masculino , Estudos Retrospectivos
4.
Arch Cardiol Mex ; 90(2): 108-115, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32897262

RESUMO

Background: Paravalvular leak (PVL) is a frequent and important complication after surgical valvular replacement that can cause heart failure and hemolytic anemia and is associated with poor clinical outcomes. Surgical reoperation has been the standard treatment, but it is associated with high morbidity and mortality. Transcatheter closure is a therapeutic alternative. The aim of the present study is to analyze the feasibility and the short- and medium-term outcomes of the transcatheter closure of PVLs. Methods: Single-center registry of consecutive patients with post-surgical PVLs that underwent transcatheter closure, between January 2006 and December 2016. Efficacy and safety results were analyzed during the procedure and at 6-month follow-up. Results: Twenty-one PVLs (15 mitral, 5 aortic, and 1 tricuspid) were closure during 20 procedures. In the initial echocardiography, 91% of the leaks were severe. The most used device was the Amplatzer Vascular Plug III® in 10 procedures (50%). The three-dimensional transesophageal echocardiography was used in 70% of cases. The device was successfully implanted in 95% of cases, a regurgitation reduction ≥ 1 grade was achieved in 95% of the cases, and the clinical success was 79%. Six-month survival was 100%; however, three cases required valvular surgery (15%). Conclusions: Transcatheter closure of PVLs is a feasible and safe procedure with high rates of technical, echocardiographic, and clinical success in the short and medium term. It is an adequate therapeutic alternative, mainly in high surgical risk patients and multiples comorbidities.


Introducción: La fuga paravalvular es una complicación frecuente e importante posterior al reemplazo valvular quirúrgico que puede ocasionar insuficiencia cardiaca, anemia hemolítica y se relaciona con malos resultados clínicos. La reintervención quirúrgica ha sido el tratamiento habitual, pero se acompaña de alta morbimortalidad. El cierre transcatéter es una alternativa terapéutica. El objetivo del presente estudio es analizar la factibilidad y los resultados a corto y mediano plazo del cierre transcatéter de fugas paravalvulares con dispositivos oclusores. Métodos: Registro unicéntrico de una serie consecutiva de pacientes con fugas paravalvulares posquirúrgicas que fueron cerradas vía transcatéter con dispositivos oclusores, entre enero del 2006 y diciembre del 2016. Se analizaron los resultados de eficacia y seguridad durante el procedimiento y a seis meses. Resultados: Se trataron 21 fugas paravalvulares (15 mitrales, 5 aórticas y 1 tricuspídea) durante 20 procedimientos. El 91% de las fugas fue grave en la ecocardiografía inicial. El dispositivo utilizado con más frecuencia fue el Amplatzer Vascular Plug III® en 10 procedimientos (50%). Se utilizó ecocardiografía transesofágica tridimensional en 70% de los casos. Se logró implantar el dispositivo con éxito en el 95% de los casos; se consiguió una reducción ≥ 1 del grado de regurgitación en el 95% de las veces y se alcanzó el éxito clínico en el 79%. A seis meses la supervivencia fue del 100%; sin embargo, tres casos requirieron cirugía valvular (15%). Conclusiones: El cierre transcatéter de fugas paravalvulares es un procedimiento factible, seguro y con tasas elevadas de éxito técnico, ecocardiográfico y clínico a corto y mediano plazo. Es una alternativa terapéutica adecuada, en particular en pacientes considerados de alto riesgo quirúrgico y múltiples comorbilidades.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Adulto , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Sistema de Registros , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento
5.
Arch Cardiol Mex ; 90(2): 122-129, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32459208

RESUMO

Background: Paravalvular leak is a frequent and important complication after surgical valvular replacement that can cause heart failure, hemolytic anemia and is associated with poor clinical outcomes. Surgical reoperation has been the standard treatment, but it is associated with high morbidity and mortality. Transcatheter closure is a therapeutic alternative. The aim of the present study is to analyze the feasibility and the short and medium-term outcomes of the transcatheter closure of paravalvular leaks. Methods: Single-centre registry of consecutive patients with post-surgical paravalvular leaks, that underwent transcatheter closure, between January 2006 and December 2016. Efficacy and safety results were analyzed during the procedure and at 6-month follow-up. Results: 21 paravalvular leaks (15 mitral, 5 aortic and 1 tricuspid) were closure during 20 procedures. In the initial echocardiography 91% of the leaks were severe. The most used device was the Amplatzer Vascular Plug III® in 10 procedures (50%). The 3D transesophageal echocardiography was used in 70% of cases. The device was successfully implanted in 95% of cases, a regurgitation reduction ≥ 1 grade was achieved in 95% of the cases, and the clinical success was 79%. Six month survival was 100%; however, 3 cases required valvular surgery (15%). Conclusions: Transcatheter closure of paravalvular leaks is a feasible and safe procedure with high rates of technical, echocardiographic and clinical success in the short and medium term. It is an adequate therapeutic alternative, mainly in high surgical risk patients and multiples comorbidities.


Introducción: La fuga paravalvular es una complicación frecuente e importante posterior al reemplazo valvular quirúrgico que puede ocasionar insuficiencia cardiaca, anemia hemolítica y se relaciona con malos resultados clínicos. La reintervención quirúrgica ha sido el tratamiento habitual, pero se acompaña de alta morbimortalidad. El cierre transcatéter es una alternativa terapéutica. El objetivo del presente estudio es analizar la factibilidad y los resultados a corto y mediano plazo del cierre transcatéter de fugas paravalvulares con dispositivos oclusores. Métodos: Registro unicéntrico de una serie consecutiva de pacientes con fugas paravalvulares posquirúrgicas que fueron cerradas vía transcatéter con dispositivos oclusores, entre enero del 2006 y diciembre del 2016. Se analizaron los resultados de eficacia y seguridad durante el procedimiento y a seis meses. Resultados: Se trataron 21 fugas paravalvulares (15 mitrales, 5 aórticas y 1 tricuspídea) durante 20 procedimientos. El 91% de las fugas fue grave en la ecocardiografía inicial. El dispositivo utilizado con más frecuencia fue el Amplatzer Vascular Plug III® en 10 procedimientos (50%). Se utilizó ecocardiografía transesofágica tridimensional en 70% de los casos. Se logró implantar el dispositivo con éxito en el 95% de los casos; se consiguió una reducción ≥ 1 del grado de regurgitación en el 95% de las veces y se alcanzó el éxito clínico en el 79%. A seis meses la supervivencia fue del 100%; sin embargo, tres casos requirieron cirugía valvular (15%). Conclusiones: El cierre transcatéter de fugas paravalvulares es un procedimiento factible, seguro y con tasas elevadas de éxito técnico, ecocardiográfico y clínico a corto y mediano plazo. Es una alternativa terapéutica adecuada, en particular en pacientes considerados de alto riesgo quirúrgico y múltiples comorbilidades.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/cirurgia , Adulto , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/patologia , Valva Tricúspide/cirurgia
6.
Biomark Med ; 14(18): 1747-1757, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33346701

RESUMO

Aim: To analyze the association of NKX2.5 gene with congenital heart disease (CHD), and to determine if the variants rs703752, rs3729753 and rs2277923 increase the risk for developing CHD. Materials & methods: PubMed, EBSCO and Web of Science databases were screened to identify eligible studies. Through a comprehensive meta-analysis software, the association between NKX2.5 gene variants and susceptibility of CHD was calculated by pooled odd ratio (ORs) and 95% CI. Results: We observed that the allelic model of rs703752 and rs2277923 increased the risk in the overall population: OR = 1.24; 95% CI: 1.00-1.55; Z p-value = 0.049; OR = 1.18; 95% CI: 0.01-1.37; Z p-value = 0.036; respectively. Conclusion: Our results suggested that the rs703752 and rs2277923 polymorphisms of the NKX2.5 gene are associated with CHD.


Assuntos
Cardiopatias Congênitas/genética , Proteína Homeobox Nkx-2.5/genética , Proteína Homeobox Nkx-2.5/metabolismo , Alelos , Bases de Dados Genéticas , Frequência do Gene , Predisposição Genética para Doença , Cardiopatias Congênitas/metabolismo , Humanos , Polimorfismo de Nucleotídeo Único
7.
Arch. cardiol. Méx ; 90(2): 108-115, Apr.-Jun. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131018

RESUMO

Abstract Background: Paravalvular leak (PVL) is a frequent and important complication after surgical valvular replacement that can cause heart failure and hemolytic anemia and is associated with poor clinical outcomes. Surgical reoperation has been the standard treatment, but it is associated with high morbidity and mortality. Transcatheter closure is a therapeutic alternative. The aim of the present study is to analyze the feasibility and the short- and medium-term outcomes of the transcatheter closure of PVLs. Methods: Single-center registry of consecutive patients with post-surgical PVLs that underwent transcatheter closure, between January 2006 and December 2016. Efficacy and safety results were analyzed during the procedure and at 6-month follow-up. Results: Twenty-one PVLs (15 mitral, 5 aortic, and 1 tricuspid) were closure during 20 procedures. In the initial echocardiography, 91% of the leaks were severe. The most used device was the Amplatzer Vascular Plug III® in 10 procedures (50%). The three-dimensional transesophageal echocardiography was used in 70% of cases. The device was successfully implanted in 95% of cases, a regurgitation reduction ≥ 1 grade was achieved in 95% of the cases, and the clinical success was 79%. Six-month survival was 100%; however, three cases required valvular surgery (15%). Conclusions: Transcatheter closure of PVLs is a feasible and safe procedure with high rates of technical, echocardiographic, and clinical success in the short and medium term. It is an adequate therapeutic alternative, mainly in high surgical risk patients and multiples comorbidities.


Resumen Introducción: La fuga paravalvular es una complicación frecuente e importante posterior al reemplazo valvular quirúrgico que puede ocasionar insuficiencia cardiaca, anemia hemolítica y se relaciona con malos resultados clínicos. La reintervención quirúrgica ha sido el tratamiento habitual, pero se acompaña de alta morbimortalidad. El cierre transcatéter es una alternativa terapéutica. El objetivo del presente estudio es analizar la factibilidad y los resultados a corto y mediano plazo del cierre transcatéter de fugas paravalvulares con dispositivos oclusores. Métodos: Registro unicéntrico de una serie consecutiva de pacientes con fugas paravalvulares posquirúrgicas que fueron cerradas vía transcatéter con dispositivos oclusores, entre enero del 2006 y diciembre del 2016. Se analizaron los resultados de eficacia y seguridad durante el procedimiento y a seis meses. Resultados: Se trataron 21 fugas paravalvulares (15 mitrales, 5 aórticas y 1 tricuspídea) durante 20 procedimientos. El 91% de las fugas fue grave en la ecocardiografía inicial. El dispositivo utilizado con más frecuencia fue el Amplatzer Vascular Plug III® en 10 procedimientos (50%). Se utilizó ecocardiografía transesofágica tridimensional en 70% de los casos. Se logró implantar el dispositivo con éxito en el 95% de los casos; se consiguió una reducción ≥ 1 del grado de regurgitación en el 95% de las veces y se alcanzó el éxito clínico en el 79%. A seis meses la supervivencia fue del 100%; sin embargo, tres casos requirieron cirugía valvular (15%). Conclusiones: El cierre transcatéter de fugas paravalvulares es un procedimiento factible, seguro y con tasas elevadas de éxito técnico, ecocardiográfico y clínico a corto y mediano plazo. Es una alternativa terapéutica adecuada, en particular en pacientes considerados de alto riesgo quirúrgico y múltiples comorbilidades.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco/métodos , Insuficiência da Valva Mitral/cirurgia , Fatores de Tempo , Falha de Prótese , Próteses Valvulares Cardíacas , Sistema de Registros , Seguimentos , Resultado do Tratamento , Ecocardiografia Transesofagiana , Ecocardiografia Tridimensional , Dispositivo para Oclusão Septal
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa