Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Catheter Cardiovasc Interv ; 102(4): 683-687, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37506123

RESUMO

Covered stent correction of a superior sinus venosus atrial septal defect is increasingly performed as an alternative to surgical repair. While sinus node dysfunction requiring pacemaker implantation may be required after surgical repair, this has not been previously reported after covered stent implantation. We reviewed the experience in two interventional centers. Balloon inflation in the superior vena cava was used to confirm the anomalous pulmonary vein drainage would be unobstructed after stent implantation. During balloon testing in 62 consecutive patients, we assessed gradients across the pulmonary vein to left atrium while monitoring the rhythm. We observed the outcomes after covered stent correction in 51 patients. In a single patient, significant bradycardia and pauses developed on repeat balloon testing and the procedure was abandoned without stent implantation. In another patient, there was no sign of sinus node dysfunction during balloon testing but several hours after stent implantation, the patient became symptomatic from sinus bradycardia and pauses and had a pacemaker implanted 3 days later. Over a year later there are some signs of improvement in sinus node function. While sinus node dysfunction has not been described previously during balloon testing or after stent implantation, this report demonstrates for the first time that it may occur. Larger registries are therefore required to monitor for this uncommon complication.

2.
J Cardiothorac Vasc Anesth ; 35(6): 1638-1645, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33419684

RESUMO

OBJECTIVES: The aim of this study was to analyze whether right ventricular free wall longitudinal strain (RVFWSL) could be a predictor of low-cardiac-output syndrome (LCOS) after surgical aortic valve replacement (SAVR) in patients with left ventricular ejection fraction ≥40%. DESIGN: Prospective, observational study. SETTING: The study was conducted at a third level university hospital. PARTICIPANTS: The study comprised 75 patients with severe aortic stenosis and LVEF ≥40% who underwent SAVR. The primary outcome was the occurrence of LCOS, and secondary outcomes were in-hospital mortality, hospital stay, or vasoplegic syndrome. INTERVENTIONS: Patients were divided into two groups (LCOS and no LCOS), and RVFWSL was analyzed to determine whether it is a predictor for LCOS. In addition, a receiver operating characteristic curve also was constructed, and the best cutoff value to predict LCOS was found. Furthermore, the reproducibility of RVFWSL measurements was evaluated. MEASUREMENT AND MAIN RESULTS: The incidence of LCOS was 20% in the present study's cohort. After multivariate analysis, cross-clamp time (odds ratio 1.06, 95% confidence interval 1.02-1.11; p = 0.002) and RVFWSL (odds ratio 1.41, 95% confidence interval 1.07-1.87; p = 0.015) were the only predictors of LCOS. However, RVFWSL did not show association with secondary outcomes (p > 0.05 for all). The area under the curve of RVFWSL to predict LCOS was 0.75, and the best cutoff value was -17.3%, with a sensitivity of 86.7% and specificity of 61.7%. CONCLUSIONS: RVFWSL seems to be a predictor of LCOS in patients with severe aortic stenosis and LVEF ≥40% undergoing SAVR. RVFWSL less than -17.3% may identify patients at increased risk for LCOS.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
3.
Echocardiography ; 37(5): 769-780, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32338402

RESUMO

Increased catheter-based interventions in congenital and structural heart disease require imaging modalities to be oriented in the same visual perspective. The use of echocardiography-fluoroscopy fusion (EFF) imaging has been developed for better characterization of complex anatomy and to facilitate key steps in interventional procedures. This review will detail the technology behind EFF, the differences between the two ultrasound fusion systems, and essential features of EFF imaging in congenital and structural heart disease interventions.


Assuntos
Cardiopatias Congênitas , Radiografia Intervencionista , Cateterismo Cardíaco , Ecocardiografia , Fluoroscopia , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Imagem Multimodal , Ultrassonografia de Intervenção
4.
Catheter Cardiovasc Interv ; 92(7): 1323-1328, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30196542

RESUMO

BACKGROUND: Variable patent ductus arteriosus (PDA) morphology and the need to close PDAs in small size patients has led physicians to use Amplatzer Vascular Plugs (AVP) and recently available Amplatzer Duct Occluder II - Additional Sizes (ADO II AS). The purpose of this study was to analyze the safety, efficacy, and complication rates of the ADO II AS and AVPs, specifically AVP II. METHODS: All patients undergoing PDA closure with an AVP or ADO II AS from 2011 to 2016 were included. Clinical, echocardiographic, and angiographic data were collected and reviewed. RESULTS: Four hundred and sixty-nine patients were included. Median age was 27 months (0.75-852) and the median weight was 11.4 kg (1-92). There were 51 patients ≤5 kg. Type A PDA was most common in 48% (n = 225), followed by type E (27.5%, n = 129), type D (13%, n = 61), type C (10.2%, n = 48), and type B (1.3%, n = 6). Devices included AVP II (n = 421), ADO II AS (n = 30), and AVP IV (n = 18), left pulmonary artery stenosis occurred in 4.3% (n = 20). One patient required surgery for severe stenosis; the remaining cases were mild and required no intervention. Device embolization occurred in 3 patients (10%) with the ADO II AS. Successful device closure was achieved in 98.9% of cases. CONCLUSIONS: The AVP II was highly effective for closing PDAs in smaller babies with varying morphologies and is safe when used in small sized patients with relatively low risk of complications. More studies are warranted to clarify the risks of ADO II AS.


Assuntos
Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Cardiol Young ; 27(6): 1219-1220, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28606209

RESUMO

A 10-month-old girl with type I Loeys-Dietz syndrome developed a conspicuous aortic root aneurysm that was well demonstrated on chest X-ray/CT reconstruction. She underwent successful valve-spare repair of the ascending aorta.


Assuntos
Aorta/diagnóstico por imagem , Aneurisma da Aorta Torácica/complicações , Implante de Prótese Vascular/métodos , Síndrome de Loeys-Dietz/complicações , Aorta/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/cirurgia , Feminino , Seguimentos , Humanos , Lactente , Síndrome de Loeys-Dietz/diagnóstico , Tomografia Computadorizada por Raios X
7.
Cells ; 12(4)2023 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-36831251

RESUMO

The TBX20 gene has a key role during cardiogenesis, and it has been related to epigenetic mechanisms in congenital heart disease (CHD). The purpose of this study was to assess the association between DNA methylation status and congenital septal defects. The DNA methylation of seven CpG sites in the TBX20 gene promoter was analyzed through pyrosequencing as a quantitative method in 48 patients with congenital septal defects and 104 individuals with patent ductus arteriosus (PDA). The average methylation was higher in patients than in PDA (p < 0.001). High methylation levels were associated with a higher risk of congenital septal defects (OR = 4.59, 95% CI = 1.57-13.44, p = 0.005). The ROC curve analysis indicated that methylation of the TBX20 gene could be considered a risk marker for congenital septal defects (AUC = 0.682; 95% CI = 0.58-0.77; p < 0.001). The analysis of environmental risk factors in patients with septal defects and PDA showed an association between the consumption of vitamins (OR = 0.10; 95% CI = 0.01-0.98; p = 0.048) and maternal infections (OR = 3.10; 95% CI = 1.26-7.60; p = 0.013). These results suggest that differences in DNA methylation of the TBX20 gene can be associated with septal defects.


Assuntos
Permeabilidade do Canal Arterial , Cardiopatias Congênitas , Proteínas com Domínio T , Criança , Humanos , Epigênese Genética , Cardiopatias Congênitas/genética , Regiões Promotoras Genéticas , Fatores de Risco , Proteínas com Domínio T/genética
8.
Front Pediatr ; 11: 1200395, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37484769

RESUMO

Endothelial progenitor cells and circulating endothelial cells have been proposed as useful markers of severity and disease progression in certain vascular diseases, including pulmonary arterial hypertension. Our study focused on evaluating the levels of circulating endothelial progenitor cells and circulating endothelial cells in patients with congenital left-to-right shunts and pulmonary hypertension undergoing definitive repair. Endothelial progenitor cells (identified by simultaneous co-expression of CD45dim, CD34 + and KDR2 + surface antibodies) and circulating endothelial cells (identified by simultaneous co-expression of inherent antibodies CD45-, CD31+, CD146 + and CD105+) were prospectively measured in seventy-four children (including children with Down syndrome), median age six years (2.75-10), with clinically significant left-to-right shunts undergoing transcatheter or surgical repair and compared to thirty healthy controls. Endothelial progenitor cells and, particularly, circulating endothelial cells were significantly higher in children with heart disease and pulmonary arterial hypertension when compared to controls. Endothelial progenitor cells showed significant correlation with pulmonary vascular resistance index when measured both systemically (r = 0.259; p = 0.026) and in the superior vena cava (r = 0.302; p = 0.009). Children with Down syndrome showed a stronger correlation between systemic cellularity and pulmonary vascular resistance index (r = 0.829; p = 0.002). Endothelial progenitor cells were reduced along their transit through the lung, whereas circulating endothelial cells did not suffer any modification across the pulmonary circulation. In children with yet to be repaired left-to-right shunts, endothelial progenitor cells and circulating endothelial cell counts are increased compared to healthy subjects.

9.
Circ Heart Fail ; 16(7): e00080, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37357777

RESUMO

Patients with pulmonary hypertension associated with congenital heart disease make up an increasing proportion of the total pulmonary hypertension population who bring with them added complexity because of underlying anatomical and hemodynamic abnormalities. Currently, no consensus recommendations are available on how to best manage this group of patients for either the primary cardiologist or pulmonary hypertension subspecialist, including timing of referral. The purposes of this document are (1) to describe the various pulmonary hypertension groups and subgroups associated with congenital heart disease, (2) to describe imaging modalities used in patient evaluation, (3) to elucidate medical and surgical management considerations, (4) to highlight disparities within this population, and (5) to identify gaps and future research needs of patients with pulmonary hypertension associated with congenital heart disease.


Assuntos
Cardiopatias Congênitas , Insuficiência Cardíaca , Hipertensão Pulmonar , Estados Unidos/epidemiologia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/terapia , American Heart Association , Insuficiência Cardíaca/complicações , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Hemodinâmica
10.
Front Cardiovasc Med ; 10: 1270608, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37928756

RESUMO

Introduction: Time-fixed analyses have traditionally been utilized to examine outcomes in post-infarction ventricular septal defect (VSD). The aims of this study were to: (1) analyze the relationship between VSD closure/non-closure and mortality; (2) assess the presence of immortal-time bias. Material and methods: In this retrospective cohort study, patients with ST-elevation myocardial infarction (STEMI) complicated by VSD. Time-fixed and time-dependent Cox regression methodologies were employed. Results: The study included 80 patients: surgical closure (n = 26), transcatheter closure (n = 20), or conservative management alone (n = 34). At presentation, patients without VSD closure exhibited high-risk clinical characteristics, had the shortest median time intervals from STEMI onset to VSD development (4.0, 4.0, and 2.0 days, respectively; P = 0.03) and from STEMI symptom onset to hospital arrival (6.0, 5.0, and 0.8 days, respectively; P < 0.0001). The median time from STEMI onset to closure was 22.0 days (P = 0.14). In-hospital mortality rate was higher among patients who did not undergo defect closure (50%, 35%, and 88.2%, respectively; P < 0.0001). Closure of the defect using a fixed-time method was associated with lower in-hospital mortality (HR = 0.13, 95% CI 0.05-0.31, P < 0.0001, and HR 0.13, 95% CI 0.04-0.36, P < 0.0001, for surgery and transcatheter closure, respectively). However, when employing a time-varying method, this association was not observed (HR = 0.95, 95% CI 0.45-1.98, P = 0.90, and HR 0.88, 95% CI 0.41-1.87, P = 0.74, for surgery and transcatheter closure, respectively). These findings suggest the presence of an immortal-time bias. Conclusions: This study highlights that using a fixed-time analytic approach in post-infarction VSD can result in immortal-time bias. Researchers should consider employing time-dependent methodologies.

11.
J Clin Med ; 12(1)2022 Dec 23.
Artigo em Inglês | MEDLINE | ID: mdl-36614920

RESUMO

Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005-2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

12.
Biology (Basel) ; 11(1)2022 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-35053095

RESUMO

The TBX5 gene regulates morphological changes during heart development, and it has been associated with epigenetic abnormalities observed in congenital heart defects (CHD). The aim of this research was to evaluate the association between DNA methylation levels of the TBX5 gene promoter and congenital septal defects. DNA methylation levels of six CpG sites in the TBX5 gene promoter were evaluated using pyrosequencing analysis in 35 patients with congenital septal defects and 48 controls. Average methylation levels were higher in individuals with congenital septal defects than in the controls (p < 0.004). In five CpG sites, we also found higher methylation levels in patients than in the controls (p < 0.05). High methylation levels were associated with congenital septal defects (OR = 3.91; 95% CI = 1.02-14.8; p = 0.045). The analysis of Receiver Operating Characteristic (ROC) showed that the methylation levels of the TBX5 gene could be used as a risk marker for congenital septal defects (AUC = 0.68, 95% CI = 0.56-0.80; p = 0.004). Finally, an analysis of environmental factors indicated that maternal infections increased the risk (OR = 2.90; 95% CI = 1.01-8.33; p = 0.048) of congenital septal defects. Our data suggest that a high DNA methylation of the TBX5 gene could be associated with congenital septal defects.

13.
Circ Cardiovasc Interv ; 13(11): e008938, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33167702

RESUMO

BACKGROUND: Balloon angioplasty for native coarctation of the aorta (CoA) is successful in children and adults but in neonates results in frequent restenosis. The efficacy of balloon angioplasty for native CoA during infancy beyond the neonatal period was examined in infants aged 3 to 12 months of age. METHODS: A retrospective review of 68 infants who underwent balloon angioplasty for native CoA. 95% CI are in parentheses. RESULTS: Procedural age was (mean±SD) 6±3.4 months and weight was 7±1.8 kg. Balloon angioplasty produced a large decrease in both the noninvasive arm-to-leg blood pressure gradient (41.2±18.7 to 5.6±9.6 mm Hg) and the invasive peak systolic pressure gradient (34±12 to 11±9 mm Hg). Balloon angioplasty increased the CoA diameter from 2.7±1 mm to 4.6±1.2 mm. One patient was lost to follow-up. A catheter reintervention was required in 11.8% and surgery in 10.3%. The hazard of reintervention was highest early. Median freedom from reintervention was 89% (95% CI, 80%-96%) at 1 year, 83% (95% CI, 73%-92%) at 5 years, and 81% (95% CI, 69%-90%) at 10 years. Femoral artery thrombosis was documented in 6 (9%) infants without any long-term consequence. One patient developed a small aortic aneurysm late and has not required treatment. A robust estimate of the frequency of aortic aneurysms remains to be determined as the majority of subjects have not had cross-sectional imaging. CONCLUSIONS: Balloon angioplasty of native CoA is effective and safe in infants aged 3 to 12 months with outcomes comparable to those in older children and adults. Catheter reinterventions can avoid the need for surgery in most patients.


Assuntos
Angioplastia com Balão , Coartação Aórtica/cirurgia , Adolescente , Fatores Etários , Angioplastia com Balão/efeitos adversos , Coartação Aórtica/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Recidiva , Retratamento , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
14.
Seizure ; 81: 287-291, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32927243

RESUMO

PURPOSE: The Status Epilepticus Severity Score (STESS) is one of the most well-known clinical scoring systems to predict mortality in status epilepticus (SE). The objective of this study was to validate STESS in a Colombian population. METHOD: We evaluated historical data of adult patients (age ≥16 years) with a clinical or electroencephalographic diagnosis of SE admitted between 2014 and 2017. Prospectively, we included patients admitted from January to June of 2018. The primary outcome was in-hospital mortality. Receiver operating characteristic (ROC)-analysis, determination of best cutoff values, sensitivity, specificity, and positive and negative likelihood ratios were performed. RESULTS: The sample was 395 patients, with in-hospital mortality of 16.8 %. The area under the ROC curve for STESS was 0.84. A cutoff point of ≥3 produced the highest sensitivity of 84.9 % (95 % CI 73.9 %-92.5 %) and a specificity of 65.7 % (95 % CI 60.2 %-70.8 %), with a positive likelihood ratio of 2.5 and a negative likelihood ratio of 0.2. CONCLUSIONS: STESS is a useful tool to predict mortality in patients with SE. In Medellin, Colombia, a STESS < 3 allows the identification of the patients who survive reliably. Those patients with a score <3 may have a better prognosis, and treatment with fewer side effects than anaesthetics could be suggested, always remembering the importance of the treating physician's clinical judgement.


Assuntos
Estado Epiléptico , Adolescente , Adulto , Colômbia , Mortalidade Hospitalar , Hospitais , Humanos , Prognóstico , Curva ROC , Índice de Gravidade de Doença , Estado Epiléptico/diagnóstico
15.
Int J Cardiovasc Imaging ; 36(4): 595-604, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31894525

RESUMO

To investigate the role of right ventricular free wall strain (RVFWSL) to predict low functional capacity in repaired tetralogy of Fallot (rTOF). We prospectively enrolled 33 patients with rTOF with moderate to severe PR who underwent rest and peak exercise echocardiography on a semisupine cycloergometer. Conventional function and strain imaging parameters of both ventricles were measured. Patients performing < 7 METS were defined to have low functional capacity. Logistic regression was used to identify parameters associated with low functional capacity. Eleven patients (33.3%) had low functional capacity. These patients were shorter (height 155 ± 7 vs 163 ± 9 cm, p = 0.023), more frequently female (27.3 vs 72.7%, p = 0.024) and had history of Blalock-Taussig shunt (45.5 vs 9.1%, p = 0.027). On multivariate analysis RVFWSL was the only predictor of low functional capacity OR 1.39 (CI 95%, 1.06-1.83., p = 0.018) per % change. A RVFWSL < 17% (absolute value) had an AUC of 0.785, sensitivity of 81.8% and specificity of 77.3% to predict low functional capacity. Right ventricular free wall strain is an independent predictor of low functional capacity in repaired tetralogy of Fallot with moderate to severe PR. A value < 17% might be useful in deciding when to perform pulmonary valve replacement, when functional capacity cannot be objectively measured.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Doppler em Cores , Ecocardiografia sob Estresse , Teste de Esforço , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita , Adolescente , Adulto , Ciclismo , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Tomada de Decisão Clínica , Feminino , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/cirurgia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/fisiopatologia , Resultado do Tratamento , Adulto Jovem
16.
Can J Cardiol ; 34(6): 726-735, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29801738

RESUMO

BACKGROUND: Novel quantification of stroke volume according to mitral inflow and aortic outflow using automated real-time 3-dimensional volume colour flow Doppler echocardiography (3D-RT-VCFDE) is more accurate than 2-dimensional echocardiography and has excellent correlation with cardiac magnetic resonance imaging-based flows in adults. This technology is applied for the first time to the right heart and in children. METHODS: 3D-RT-VCFDE was performed in 61 image sets of flow through the aortic (AV), mitral (MV), pulmonary (PV), and tricuspid (TV) valves of 34 children. These were compared with stroke volumes of the right (RV) and left (LV) ventricles and ratio of pulmonary to systemic blood flow determined using the Fick method in 31 children with atrial shunts. RESULTS: The mean age was 8.0 ± 3.3 years, and the mean weight was 27.8 ± 10.0 kg. The mean temporal resolution for flow analyses was ≥ 22 volumes per second. In conditions with no shunt, the correlations were: AV with MV flows (r = 0.98), PV with TV flows (r = 0.96), RV stroke volume with PV flow (r = 0.95), and with TV flow (r = 0.93), LV stroke volume with AV flow (r = 0.87), and with MV flow (r = 0.89). Fick ratio of pulmonary to systemic blood flow correlations were: PV/AV ratio (r = 0.84), TV/MV ratio (r = 0.87), and RV/LV ratio (r = 0.70). CONCLUSIONS: Stroke volume determined using automated 3D-RT-VCFDE is feasible in children and in the right side of the heart. This technique potentially provides a noninvasive alternative to historically invasively acquired hemodynamic data and to cardiac magnetic resonance imaging.


Assuntos
Ecocardiografia Tridimensional/métodos , Valvas Cardíacas , Ventrículos do Coração , Hemodinâmica/fisiologia , Criança , Pré-Escolar , Precisão da Medição Dimensional , Ecocardiografia Doppler em Cores/métodos , Feminino , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Masculino , Reprodutibilidade dos Testes
17.
Biomed Res Int ; 2018: 3742362, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29850507

RESUMO

BACKGROUND: Delayed sternal closure (DSC) after cardiac surgery is a therapeutic option in the treatment of the severely impaired heart in pediatric cardiac surgery. METHODS: A single-center retrospective review of all bypass surgeries performed over a 10-year period (2003-2012). RESULTS: Of a total of 2325 patients registered in our database, the DSC group included 259 cases (11%), and the remaining 2066 cases (89%) constituted the control group (PSC). RACHS-1 risk was higher for the DSC group (74% had a score of 3 or 4) than for the PSC group (82% had a score of 2 or 3). The most frequent diagnosis for the DSC group was transposition of the great arteries (28%). We found out that hemodynamic instability was the main indication observed in patients aged ≤ 8 years (63%), while bleeding was the principal indication for patients aged ≥ 8 years (94%) (p ≤ 0.001). The average time between surgery and sternal closure was 2.3 ± 1.4 days. Overall mortality rates were higher for patients of the DSC group (22%) than for the PSC group (8.7%) (OR: 0.4 (95% CI: 0.4 to 0.5), p < 0.05). There were six patients with DSC who developed mediastinitis (2.3%). The risk of mediastinitis was significantly higher when DSC was performed 4 days after the primary surgery. CONCLUSIONS: DSC is an important management strategy for congenital cardiac surgery in infants and children. The prolonged sternal closure time is associated with an increased rate of postoperative mediastinitis.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Esterno/cirurgia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Criança , Pré-Escolar , Demografia , Feminino , Cardiopatias/congênito , Cardiopatias/diagnóstico , Cardiopatias/mortalidade , Cardiopatias/cirurgia , Humanos , Masculino , Período Pós-Operatório , Fatores de Risco , Resultado do Tratamento
19.
Ann Pediatr Cardiol ; 9(1): 39-41, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27011690

RESUMO

Radiofrequency (RF) assisted perforation of the atrial septum was performed successfully in three infants using a 0.035" RF wire deployed through a Williams right posterior catheter. Balloon atrial septoplasty was performed over the 0.035" RF wire in two of them, shortening the procedural time.

20.
Can J Cardiol ; 32(12): 1575.e13-1575.e15, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27746092

RESUMO

A 33-day-old infant with obstructed cor triatriatum sinister and partial anomalous pulmonary venous drainage presented with respiratory distress and fever. Her suprasystemic pulmonary hypertension was relieved by opening the connection to the right atrium using balloon atrial septoplasty and septostomy, and to the inferior chamber using balloon dilation of a fenestration in the dividing membrane. This enabled extubation and discharge, with elective surgical repair at 2 months. To our knowledge, this is the youngest patient to receive a catheter intervention for obstructed cor triatriatum sinister, providing relief of pulmonary hypertension and postponement of surgical repair.


Assuntos
Septo Interatrial , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Coração Triatriado , Hipertensão Pulmonar , Cuidados Paliativos/métodos , Septo Interatrial/patologia , Septo Interatrial/fisiopatologia , Septo Interatrial/cirurgia , Coração Triatriado/complicações , Coração Triatriado/diagnóstico , Coração Triatriado/fisiopatologia , Coração Triatriado/cirurgia , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Lactente , Reoperação/métodos , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa