Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Environ Technol ; 37(2): 279-91, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26230635

RESUMO

One of the waste products of the industrial process of the sugar and alcohol agribusiness is filter cake (FC). This waste product has high levels of organic matter, mainly proteins and lipids, and is rich in calcium, nitrogen, potassium and phosphorous. In this work we characterized samples of FC from sugar and alcohol industries located in sugarcane-producing regions in Brazil and assessed the adsorption of potentially toxic metals (Cu(II), Cd(II), Pb(II), Ni(II) and Cr(III)) by this waste in mono- and multi-elemental systems, seeking to use FC as an adsorbent in contaminated environments. The characterization of FCs showed significant differences between the samples and the adsorption studies showed retention of over 90% of potentially toxic metals. In a competitive environment (multi-metallic solution), the FC was effective in adsorbing all metals except lead, but less effective compared to the mono-metallic solution. These results show the potential for use of this residue as an adsorbent in contaminated environments.


Assuntos
Filtração , Indústria de Processamento de Alimentos , Resíduos Industriais/análise , Metais Pesados/química , Gerenciamento de Resíduos/métodos , Resíduos/análise , Adsorção , Brasil , Carboidratos , Etanol , Gerenciamento de Resíduos/instrumentação
2.
Br J Oral Maxillofac Surg ; 52(3): 258-63, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24456609

RESUMO

Our purpose was to compare the accuracy and reliability of linear measurements for Le Fort I osteotomy using volume rendering software. We studied 11 dried skulls and used cone-beam computed tomography (CT) to generate 3-dimensional images. Linear measurements were based on craniometric anatomical landmarks that were predefined as specifically used for Le Fort I osteotomy, and identified twice each by 2 radiologists, independently, using Dolphin imaging version 11.5.04.35. A third examiner then made physical measurements using digital calipers. There was a significant difference between Dolphin imaging and the gold standard, particularly in the pterygoid process. The largest difference was 1.85mm (LLpPtg L). The mean differences between the physical and the 3-dimensional linear measurements ranged from -0.01 to 1.12mm for examiner 1, and 0 to 1.85mm for examiner 2. Interexaminer analysis ranged from 0.51 to 0.93. Intraexaminer correlation coefficients ranged from 0.81 to 0.96 and 0.57 to 0.92, for examiners 1 and 2, respectively. We conclude that the Dolphin imaging should be used sparingly during Le Fort I osteotomy.


Assuntos
Cefalometria/estatística & dados numéricos , Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Osteotomia de Le Fort/estatística & dados numéricos , Adulto , Pontos de Referência Anatômicos/diagnóstico por imagem , Feminino , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Masculino , Maxila/diagnóstico por imagem , Pessoa de Meia-Idade , Cavidade Nasal/diagnóstico por imagem , Variações Dependentes do Observador , Fossa Pterigopalatina/diagnóstico por imagem , Reprodutibilidade dos Testes , Software , Osso Esfenoide/diagnóstico por imagem , Adulto Jovem
3.
J Endod ; 40(9): 1472-6, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25146036

RESUMO

INTRODUCTION: The purpose of the present study was (1) to test the accuracy of a small-volume cone-beam computed tomographic (CBCT) device in detecting horizontal root fractures (HRFs) in teeth with and without an intracanal metallic post (IMP) and (2) to investigate the use of 2 different acquisition protocols of a CBCT device for HRF diagnosis. METHODS: Forty endodontically treated teeth with and without an IMP were examined using PreXion 3D CBCT scanner (Terarecon, San Mateo, CA) with a 5-cm high and 5-cm diameter cylinder at 0.10-mm voxel reconstruction. Two observers analyzed the samples to determine the presence and location of HRFs. RESULTS: Sensitivity values ranged from 0.40-0.80. The most favorable results were found for the samples with no IMP observed using the protocol of a higher number of x-ray projections (0.70-0.80). Accuracy in the groups with an IMP ranged from 75%-90% in the 1024 x-ray projection protocol (HI-HI group) versus 70%-85% for the same samples examined in the 512 x-ray projection protocol (HI-STD group). Intraobserver agreement ranged from relevant to perfect concordance for both protocols (HI-HI = Kappa: 0.60-1.00 and HI-STD = Kappa: 0.55-0.89). Interobserver agreement ranged from moderate to perfect concordance for both protocols (HI-HI = Kappa: 0.79-0.89 and HI-STD = Kappa: 0.42-0.76). CONCLUSIONS: Even though there are statistically significant differences for the protocol with the higher number of x-ray projections, we found high accuracy, sensitivity, sensibility, and intra- and interobserver agreement in detecting HRFs for both Prexion 3D protocols.


Assuntos
Tomografia Computadorizada de Feixe Cônico/estatística & dados numéricos , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/lesões , Dente não Vital/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Ligas Dentárias/química , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Imageamento Tridimensional/estatística & dados numéricos , Mandíbula/diagnóstico por imagem , Variações Dependentes do Observador , Imagens de Fantasmas , Técnica para Retentor Intrarradicular/instrumentação , Doses de Radiação , Sensibilidade e Especificidade , Alvéolo Dental/diagnóstico por imagem
4.
Braz Oral Res ; 27(2): 128-35, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23459775

RESUMO

The purpose of this study was to evaluate which post-processing imaging protocol would be better to analyze the additional mental foramen (AMF) in preoperative planning with cone-beam computed tomography (CBCT) exams, and to test reproducibility of measurements, using open source software (OsiriX). The software was used to detect the cases of AMF from among 58 exams for dental implant planning in edentulous mandible areas-three cases were found. The case images were submitted to qualitative analysis using 2D orthogonal MPR, 3D-MPR and 3D volume rendering protocols by two oral and maxillofacial radiologists. Quantitative analysis used the 3D-MPR protocol; the closed polygon tool measured the mental foramen (MF) and the AMF areas; the length tool measured the distance between foramina. The measurements were performed independently by the examiners, at two different times. Intra- and interexaminer agreement was assessed using the intraclass correlation coefficient. The panoramic view did not show the MF and the AMF clearly. The AMF could be detected in the parasagittal view. 2D Orthogonal MPR was effective to observe the AMF in some cases. The 3D-MPR and 3D view protocols were the most effective to locate and analyze the AMF. In conclusion, a 3D view improves visualization when anatomical points are not clearly visible. 3D-MPR was considered a more effective post-processing imaging protocol to observe foramina relationships. The high reproducibility of measurements for anatomical MF variations was established using specific tools featured in open source software for CBCT. OsiriX is realistic and recommended for preoperative planning.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Imageamento Tridimensional/métodos , Mandíbula/diagnóstico por imagem , Software , Anatomia Transversal , Feminino , Humanos , Masculino , Mandíbula/anatomia & histologia , Variações Dependentes do Observador , Tamanho do Órgão , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes
5.
Rev. patol. trop ; 26(1): 49-57, jan.-jun. 1997. ilus, tab
Artigo em Português | LILACS | ID: lil-205215

RESUMO

Foi estudada a positividade dos caramujos Biomphalaria glabrata, único hospedeiro intermidiário de esquitossomose, encontrado até agora naturalmente infectado no bairro do telégrafo, em Belém do Pará , Säo apresentados, também, os números de pessoas infectadas, observadas ao longo dos últimos dez anos pelo setor de endemias da FNS-PA, que utilizou o método Kato-Katz. Os resultados mostram que existem índices de infecçäo para os caramujos coletados, variando de 0 a 60 por cento nos logradouros pesquisados. Em relaçäo ao número de pessoas infectadas, para uma populaçäo de 44.309 habitantes, os índices variaram de 0,8 a 4,0 por cento


Assuntos
Animais , Biomphalaria/parasitologia , Esquistossomose mansoni , Manejo de Espécimes , Brasil
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa