Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
1.
N Engl J Med ; 390(3): 212-220, 2024 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-38231622

RESUMO

BACKGROUND: The Resynchronization-Defibrillation for Ambulatory Heart Failure Trial (RAFT) showed a greater benefit with respect to mortality at 5 years among patients who received cardiac-resynchronization therapy (CRT) than among those who received implantable cardioverter-defibrillators (ICDs). However, the effect of CRT on long-term survival is not known. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more (or a paced QRS duration of 200 msec or more) to receive either an ICD alone or a CRT defibrillator (CRT-D). We assessed long-term outcomes among patients at the eight highest-enrolling participating sites. The primary outcome was death from any cause; the secondary outcome was a composite of death from any cause, heart transplantation, or implantation of a ventricular assist device. RESULTS: The trial enrolled 1798 patients, of whom 1050 were included in the long-term survival trial; the median duration of follow-up for the 1050 patients was 7.7 years (interquartile range, 3.9 to 12.8), and the median duration of follow-up for those who survived was 13.9 years (interquartile range, 12.8 to 15.7). Death occurred in 405 of 530 patients (76.4%) assigned to the ICD group and in 370 of 520 patients (71.2%) assigned to the CRT-D group. The time until death appeared to be longer for those assigned to receive a CRT-D than for those assigned to receive an ICD (acceleration factor, 0.80; 95% confidence interval, 0.69 to 0.92; P = 0.002). A secondary-outcome event occurred in 412 patients (77.7%) in the ICD group and in 392 (75.4%) in the CRT-D group. CONCLUSIONS: Among patients with a reduced ejection fraction, a widened QRS complex, and NYHA class II or III heart failure, the survival benefit associated with receipt of a CRT-D as compared with ICD appeared to be sustained during a median of nearly 14 years of follow-up. (RAFT ClinicalTrials.gov number, NCT00251251.).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Estimativa de Kaplan-Meier , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Eletrocardiografia , Seguimentos , Fatores de Tempo
2.
N Engl J Med ; 388(2): 105-116, 2023 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-36342178

RESUMO

BACKGROUND: Atrial fibrillation is a chronic, progressive disorder, and persistent forms of atrial fibrillation are associated with increased risks of thromboembolism and heart failure. Catheter ablation as initial therapy may modify the pathogenic mechanism of atrial fibrillation and alter progression to persistent atrial fibrillation. METHODS: We report the 3-year follow-up of patients with paroxysmal, untreated atrial fibrillation who were enrolled in a trial in which they had been randomly assigned to undergo initial rhythm-control therapy with cryoballoon ablation or to receive antiarrhythmic drug therapy. All the patients had implantable loop recorders placed at the time of trial entry, and evaluation was conducted by means of downloaded daily recordings and in-person visits every 6 months. Data regarding the first episode of persistent atrial fibrillation (lasting ≥7 days or lasting 48 hours to 7 days but requiring cardioversion for termination), recurrent atrial tachyarrhythmia (defined as atrial fibrillation, flutter, or tachycardia lasting ≥30 seconds), the burden of atrial fibrillation (percentage of time in atrial fibrillation), quality-of-life metrics, health care utilization, and safety were collected. RESULTS: A total of 303 patients were enrolled, with 154 patients assigned to undergo initial rhythm-control therapy with cryoballoon ablation and 149 assigned to receive antiarrhythmic drug therapy. Over 36 months of follow-up, 3 patients (1.9%) in the ablation group had an episode of persistent atrial fibrillation, as compared with 11 patients (7.4%) in the antiarrhythmic drug group (hazard ratio, 0.25; 95% confidence interval [CI], 0.09 to 0.70). Recurrent atrial tachyarrhythmia occurred in 87 patients in the ablation group (56.5%) and in 115 in the antiarrhythmic drug group (77.2%) (hazard ratio, 0.51; 95% CI, 0.38 to 0.67). The median percentage of time in atrial fibrillation was 0.00% (interquartile range, 0.00 to 0.12) in the ablation group and 0.24% (interquartile range, 0.01 to 0.94) in the antiarrhythmic drug group. At 3 years, 8 patients (5.2%) in the ablation group and 25 (16.8%) in the antiarrhythmic drug group had been hospitalized (relative risk, 0.31; 95% CI, 0.14 to 0.66). Serious adverse events occurred in 7 patients (4.5%) in the ablation group and in 15 (10.1%) in the antiarrhythmic drug group. CONCLUSIONS: Initial treatment of paroxysmal atrial fibrillation with catheter cryoballoon ablation was associated with a lower incidence of persistent atrial fibrillation or recurrent atrial tachyarrhythmia over 3 years of follow-up than initial use of antiarrhythmic drugs. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Humanos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Recidiva , Taquicardia/etiologia , Resultado do Tratamento , Progressão da Doença , Seguimentos
3.
Eur Heart J ; 45(7): 510-518, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-37624879

RESUMO

BACKGROUND AND AIMS: Atrial fibrillation (AF) is a chronic progressive disorder. Persistent forms of AF are associated with increased rates of thromboembolism, heart failure, and death. Catheter ablation modifies the pathogenic mechanism of AF progression. No randomized studies have evaluated the impact of the ablation energy on progression to persistent atrial tachyarrhythmia. METHODS: Three hundred forty-six patients with drug-refractory paroxysmal AF were enrolled and randomly assigned to contact-force-guided RF ablation (CF-RF ablation, 115), 4 min cryoballoon ablation (CRYO-4, 115), or 2 min cryoballoon ablation (CRYO-2, 116). Implantable cardiac monitors placed at study entry were used for follow-up. The main outcome was the first episode of persistent atrial tachyarrhythmia. Secondary outcomes included atrial tachyarrhythmia recurrence and arrhythmia burden on the implantable monitor. RESULTS: At a median of 944.0 (interquartile range [IQR], 612.5-1104) days, 0 of 115 patients (0.0%) randomly assigned to CF-RF, 8 of 115 patients (7.0%) assigned to CRYO-4, and 5 of 116 patients (4.3%) assigned to CRYO-2 experienced an episode of persistent atrial tachyarrhythmia (P = .03). A documented recurrence of any atrial tachyarrhythmia ≥30 s occurred in 56.5%, 53.9%, and 62.9% of those randomized to CF-RF, CRYO-4, and CRYO-2, respectively; P = .65. Compared with that of the pre-ablation monitoring period, AF burden was reduced by a median of 99.5% (IQR 94.0%, 100.0%) with CF-RF, 99.9% (IQR 93.3%-100.0%) with CRYO-4, and 99.1%% (IQR 87.0%-100.0%) with CRYO-2 (P = .38). CONCLUSIONS: Catheter ablation of paroxysmal AF using radiofrequency energy was associated with fewer patients developing persistent AF on follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Taquicardia , Recidiva , Veias Pulmonares/cirurgia
4.
N Engl J Med ; 384(4): 305-315, 2021 01 28.
Artigo em Inglês | MEDLINE | ID: mdl-33197159

RESUMO

BACKGROUND: Guidelines recommend a trial of one or more antiarrhythmic drugs before catheter ablation is considered in patients with atrial fibrillation. However, first-line ablation may be more effective in maintaining sinus rhythm. METHODS: We randomly assigned 303 patients with symptomatic, paroxysmal, untreated atrial fibrillation to undergo catheter ablation with a cryothermy balloon or to receive antiarrhythmic drug therapy for initial rhythm control. All the patients received an implantable cardiac monitoring device to detect atrial tachyarrhythmia. The follow-up period was 12 months. The primary end point was the first documented recurrence of any atrial tachyarrhythmia (atrial fibrillation, atrial flutter, or atrial tachycardia) between 91 and 365 days after catheter ablation or the initiation of an antiarrhythmic drug. The secondary end points included freedom from symptomatic arrhythmia, the atrial fibrillation burden, and quality of life. RESULTS: At 1 year, a recurrence of atrial tachyarrhythmia had occurred in 66 of 154 patients (42.9%) assigned to undergo ablation and in 101 of 149 patients (67.8%) assigned to receive antiarrhythmic drugs (hazard ratio, 0.48; 95% confidence interval [CI], 0.35 to 0.66; P<0.001). Symptomatic atrial tachyarrhythmia had recurred in 11.0% of the patients who underwent ablation and in 26.2% of those who received antiarrhythmic drugs (hazard ratio, 0.39; 95% CI, 0.22 to 0.68). The median percentage of time in atrial fibrillation was 0% (interquartile range, 0 to 0.08) with ablation and 0.13% (interquartile range, 0 to 1.60) with antiarrhythmic drugs. Serious adverse events occurred in 5 patients (3.2%) who underwent ablation and in 6 patients (4.0%) who received antiarrhythmic drugs. CONCLUSIONS: Among patients receiving initial treatment for symptomatic, paroxysmal atrial fibrillation, there was a significantly lower rate of atrial fibrillation recurrence with catheter cryoballoon ablation than with antiarrhythmic drug therapy, as assessed by continuous cardiac rhythm monitoring. (Funded by the Cardiac Arrhythmia Network of Canada and others; EARLY-AF ClinicalTrials.gov number, NCT02825979.).


Assuntos
Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Adulto , Idoso , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/prevenção & controle , Flutter Atrial , Ablação por Cateter/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Modelos de Riscos Proporcionais , Qualidade de Vida , Recidiva , Prevenção Secundária , Método Simples-Cego , Taquicardia
5.
Am Heart J ; 274: 1-10, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38649085

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) in patients with prior myocardial infarction is associated with adverse quality of life and clinical outcomes, despite the presence of implanted defibrillators (ICDs). Suppression of recurrent VT can be accomplished with antiarrhythmic drug therapy or catheter ablation. The Ventricular Tachycardia Antiarrhythmics or Ablation In Structural Heart Disease 2 (VANISH2) trial is designed to determine whether ablation is superior to antiarrhythmic drug therapy as first line therapy for patients with ischemic cardiomyopathy and VT. METHODS: The VANISH2 trial enrolls patients with prior myocardial infarction and VT (with one of: ≥1 ICD shock; ≥3 episodes treated with antitachycardia pacing (ATP) and symptoms; ≥5 episodes treated with ATP regardless of symptoms; ≥3 episodes within 24 hours; or sustained VT treated with electrical cardioversion or pharmacologic conversion). Enrolled patients are classified as either sotalol-eligible, or amiodarone-eligible, and then are randomized to either catheter ablation or to that antiarrhythmic drug therapy, with randomization stratified by drug-eligibility group. Drug therapy, catheter ablation procedures and ICD programming are standardized. All patients will be followed until two years after randomization. The primary endpoint is a composite of mortality at any time, appropriate ICD shock after 14 days, VT storm after 14 days, and treated sustained VT below detection of the ICD after 14 days. The outcomes will be analyzed according to the intention-to-treat principle using survival analysis techniques RESULTS: The results of the VANISH2 trial are intended to provide data to support clinical decisions on how to suppress VT for patients with prior myocardial infarction. CLINICALTRIALS: gov registration NCT02830360.


Assuntos
Antiarrítmicos , Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/terapia , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Isquemia Miocárdica/complicações , Masculino , Feminino , Desfibriladores Implantáveis , Pessoa de Meia-Idade , Amiodarona/uso terapêutico , Resultado do Tratamento , Sotalol/uso terapêutico , Terapia Combinada
6.
Cardiovasc Diabetol ; 23(1): 82, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402400

RESUMO

BACKGROUND: Intensive glycemic control reduced coronary artery disease (CAD) events among the Action to Control Cardiovascular Disease Risk in Diabetes (ACCORD) participants with the haptoglobin (Hp) 2-2 phenotype only. It remains unknown whether Hp phenotype modifies the effect of an intensive lifestyle intervention (ILI) on CAD in type 2 diabetes. METHODS: Haptoglobin phenotype was measured in 4542 samples from the Action for Health in Diabetes (Look AHEAD) study. Cox regression models assessed the effect of ILI (focused on weight loss from caloric restriction and physical activity) versus diabetes support and education (DSE) on CAD events in each phenotype group, and within pre-specified subgroups including race/ethnicity, sex, history of cardiovascular disease, diabetes medication use, and diabetes duration. RESULTS: 1590 (35%) participants had the Hp2-2 phenotype. The ILI did not lower glycated hemoglobin (%HbA1c) to < 6.5% in either phenotype, with a peak significant difference between treatment arms of 0.5% [non-Hp2-2] and 0.6% [Hp2-2]. The cumulative CAD incidence was 13.4% and 13.8% in the DSE arm and 12.2% and 13.6% in the ILI arm for non-Hp2-2 and Hp2-2 groups, respectively. Compared to DSE, the ILI was not associated with CAD among participants without (HR = 0.95, 95% CI 0.78-1.17) or with (0.89, 0.68-1.19) the Hp2-2 phenotype (p-interaction between Hp phenotype and ILI = 0.58). After Bonferroni correction, there were no significant results among any subgroups. CONCLUSIONS: Hp phenotype did not modify the effect of the weight loss ILI on risk of CAD in Look AHEAD, potentially because it did not substantially impact glycemic control among participants with or without the Hp2-2 phenotype. Further research is needed to determine if these results are conclusive.


Assuntos
Doenças Cardiovasculares , Doença da Artéria Coronariana , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Mellitus Tipo 2/terapia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/prevenção & controle , Haptoglobinas/genética , Doenças Cardiovasculares/complicações , Estilo de Vida , Fenótipo , Redução de Peso
7.
Circulation ; 145(23): 1693-1704, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35313733

RESUMO

BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) frequently coexist and can be challenging to treat. Pharmacologically based rhythm control of AF has not proven to be superior to rate control. Ablation-based rhythm control was compared with rate control to evaluate if clinical outcomes in patients with HF and AF could be improved. METHODS: This was a multicenter, open-label trial with blinded outcome evaluation using a central adjudication committee. Patients with high-burden paroxysmal (>4 episodes in 6 months) or persistent (duration <3 years) AF, New York Heart Association class II to III HF, and elevated NT-proBNP (N-terminal pro brain natriuretic peptide) were randomly assigned to ablation-based rhythm control or rate control. The primary outcome was a composite of all-cause mortality and all HF events, with a minimum follow-up of 2 years. Secondary outcomes included left ventricular ejection fraction, 6-minute walk test, and NT-proBNP. Quality of life was measured using the Minnesota Living With Heart Failure Questionnaire and the AF Effect on Quality of Life. The primary analysis was time-to-event using Cox proportional hazards modeling. The trial was stopped early because of a determination of apparent futility by the Data Safety Monitoring Committee. RESULTS: From December 1, 2011, to January 20, 2018, 411 patients were randomly assigned to ablation-based rhythm control (n=214) or rate control (n=197). The primary outcome occurred in 50 (23.4%) patients in the ablation-based rhythm-control group and 64 (32.5%) patients in the rate-control group (hazard ratio, 0.71 [95% CI, 0.49-1.03]; P=0.066). Left ventricular ejection fraction increased in the ablation-based group (10.1±1.2% versus 3.8±1.2%, P=0.017), 6-minute walk distance improved (44.9±9.1 m versus 27.5±9.7 m, P=0.025), and NT-proBNP demonstrated a decrease (mean change -77.1% versus -39.2%, P<0.0001). Minnesota Living With Heart Failure Questionnaire demonstrated greater improvement in the ablation-based rhythm-control group (least-squares mean difference of -5.4 [95% CI, -10.5 to -0.3]; P=0.0036), as did the AF Effect on Quality of Life score (least-squares mean difference of 6.2 [95% CI, 1.7-10.7]; P=0.0005). Serious adverse events were observed in 50% of patients in both treatment groups. CONCLUSIONS: In patients with high-burden AF and HF, there was no statistical difference in all-cause mortality or HF events with ablation-based rhythm control versus rate control; however, there was a nonsignificant trend for improved outcomes with ablation-based rhythm control over rate control. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01420393.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Qualidade de Vida , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
8.
J Transl Med ; 21(1): 439, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37408044

RESUMO

BACKGROUND: Cardiopulmonary bypass (CPB) is associated with systemic inflammation, featuring increased levels of circulating pro-inflammatory cytokines. Intra-operative ultrafiltration extracts fluid and inflammatory factors potentially dampening inflammation-related organ dysfunction and enhancing post-operative recovery. This study aimed to define the impact of continuous subzero-balance ultrafiltration (SBUF) on circulating levels of major inflammatory mediators. METHODS: Twenty pediatric patients undergoing cardiac surgery, CPB and SBUF were prospectively enrolled. Blood samples were collected prior to CPB initiation (Pre-CPB Plasma) and immediately before weaning off CPB (End-CPB Plasma). Ultrafiltrate effluent samples were also collected at the End-CPB time-point (End-CPB Effluent). The concentrations of thirty-nine inflammatory factors were assessed and sieving coefficients were calculated. RESULTS: A profound increase in inflammatory cytokines and activated complement products were noted in plasma following CBP. Twenty-two inflammatory mediators were detected in the ultrafiltrate effluent. Novel mediators removed by ultrafiltration included cytokines IL1-Ra, IL-2, IL-12, IL-17A, IL-33, TRAIL, GM-CSF, ET-1, and the chemokines CCL2, CCL3, CCL4, CXCL1, CXCL2 and CXCL10. Mediator extraction by SBUF was significantly associated with molecular mass < 66 kDa (Chi2 statistic = 18.8, Chi2 with Yates' correction = 16.0, p < 0.0001). There was a moderate negative linear correlation between molecular mass and sieving coefficient (Spearman R = - 0.45 and p = 0.02). Notably, the anti-inflammatory cytokine IL-10 was not efficiently extracted by SBUF. CONCLUSIONS: CPB is associated with a burden of circulating inflammatory mediators, and SBUF selectively extracts twenty of these pro-inflammatory factors while preserving the key anti-inflammatory regulator IL-10. Ultrafiltration could potentially function as an immunomodulatory therapy during pediatric cardiac surgery. Trial registration ClinicalTrials.gov, NCT05154864. Registered retrospectively on December 13, 2021. https://clinicaltrials.gov/ct2/show/record/NCT05154864 .


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Humanos , Criança , Ultrafiltração , Estudos Retrospectivos , Citocinas , Inflamação , Quimiocina CCL2 , Anti-Inflamatórios
9.
Pacing Clin Electrophysiol ; 46(8): 1019-1031, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37402219

RESUMO

BACKGROUND: Surface ECG is a useful tool to guide mapping of focal atrial tachycardia (AT). OBJECTIVES: We aimed to construct 12-lead ECG templates for P-wave morphology (PWM) during endocardial pacing from different sites in both atria in patients with no apparent structural heart disease (derivation cohort), with the goal of creating a localization algorithm, which could subsequently be validated in a cohort of patients undergoing catheter ablation of focal AT (validation cohort). METHODS: We prospectively enrolled consecutive patients who underwent electrophysiology study, had no structural heart disease and no atrial enlargement. Atrial pacing, at twice diastolic threshold, was carried out at different anatomical sites in both atria. Paced PWM and duration were assessed. An algorithm was generated from the constructed templates of each pacing site. The algorithm was applied on a retrospective series of successfully ablated AT patients. Overall and site-specific accuracy were determined. RESULTS: Derivation cohort included 65 patients (25 men, age 37 ± 13 years). Atrial pacing was performed in 1025 sites in 61 patients (95%) in RA and in 15 patients (23%) in LA. The validation cohort included 71 patients (28 men, age 52 ± 19 years). AT were right atrial in 66.2%. The algorithm successfully predicted AT origin in 91.5% of patients (100% in LA and 87.2% in RA). It was off by one adjacent segment in the remaining 8.5%. CONCLUSIONS: A simple ECG algorithm based on paced PWM templates was highly accurate in localizing site of origin of focal AT in patients with structurally normal hearts.


Assuntos
Ablação por Cateter , Taquicardia Atrial Ectópica , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Eletrocardiografia , Átrios do Coração , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/cirurgia , Endocárdio
10.
Ann Intern Med ; 175(12): 1658-1665, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36343346

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) improve survival in patients at risk for cardiac arrest, but are associated with intravascular lead-related complications. The subcutaneous ICD (S-ICD), with no intravascular components, was developed to minimize lead-related complications. OBJECTIVE: To assess key ICD performance measures related to delivery of ICD therapy, including inappropriate ICD shocks (delivered in absence of life-threatening arrhythmia) and failed ICD shocks (which did not terminate ventricular arrhythmia). DESIGN: Randomized, multicenter trial. (ClinicalTrials.gov: NCT02881255). SETTING: The ATLAS trial. PATIENTS: 544 eligible patients (141 female) with a primary or secondary prevention indication for an ICD who were younger than age 60 years, had a cardiogenetic phenotype, or had prespecified risk factors for lead complications were electrocardiographically screened and 503 randomly assigned to S-ICD (251 patients) or transvenous ICD (TV-ICD) (252 patients). Mean follow-up was 2.5 years (SD, 1.1). Mean age was 49.0 years (SD, 11.5). MEASUREMENTS: The primary outcome was perioperative major lead-related complications. RESULTS: There was a statistically significant reduction in perioperative, lead-related complications, which occurred in 1 patient (0.4%) with an S-ICD and in 12 patients (4.8%) with TV-ICD (-4.4%; 95% CI, -6.9 to -1.9; P = 0.001). There was a trend for more inappropriate shocks with the S-ICD (hazard ratio [HR], 2.37; 95% CI, 0.98 to 5.77), but no increase in failed appropriate ICD shocks (HR, 0.61 (0.15 to 2.57). Patients in the S-ICD group had more ICD site pain, measured on a 10-point numeric rating scale, on the day of implant (4.2 ± 2.8 vs. 2.9 ± 2.2; P < 0.001) and 1 month later (1.3 ± 1.8 vs. 0.9 ± 1.5; P = 0.035). LIMITATION: At present, the ATLAS trial is underpowered to detect differences in clinical shock outcomes; however, extended follow-up is ongoing. CONCLUSION: The S-ICD reduces perioperative, lead-related complications without significantly compromising the effectiveness of ICD shocks, but with more early postoperative pain and a trend for more inappropriate shocks. PRIMARY FUNDING SOURCE: Boston Scientific.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Feminino , Humanos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Arritmias Cardíacas , Fatores de Risco , Morte Súbita Cardíaca/etiologia
12.
Am Heart J ; 254: 133-140, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36030965

RESUMO

BACKGROUND: Atrial low voltage area (LVA) catheter ablation has emerged as a promising strategy for ablation of persistent atrial fibrillation (AF). It is unclear if catheter ablation of atrial LVA increases treatment success rates in patients with persistent AF. OBJECTIVE: The primary aim of this trial is to assess the potential benefit of adjunctive catheter ablation of atrial LVA in addition to pulmonary vein isolation (PVI) in patients with persistent AF, when compared to PVI alone. The secondary aims are to evaluate safety outcomes, the quality of life and the healthcare resource utilization. METHODS/DESIGN: A multicenter, prospective, parallel-group, 2-arm, single-blinded randomized controlled trial is under way (NCT03347227). Patients who are candidates for catheter ablation for persistent AF will be randomly assigned (1:1) to either PVI alone or PVI + atrial LVA ablation. The primary outcome is 18-month documented event rate of atrial arrhythmia (AF, atrial tachycardia or atrial flutter) post catheter ablation. Secondary outcomes include procedure-related complications, freedom from atrial arrhythmia at 12 months, AF burden, need for emergency department visits/hospitalization, need for repeat ablation for atrial arrhythmia, quality of life at 12 and 18 months, ablation time, and procedure duration. DISCUSSION: Characterization of Arrhythmia Mechanism to Ablate Atrial Fibrillation (COAST-AF) is a multicenter randomized trial evaluating ablation strategies for catheter ablation. We hypothesize that catheter ablation of atrial LVA in addition to PVI will result in higher procedural success rates when compared to PVI alone in patients with persistent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Qualidade de Vida , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
13.
Europace ; 24(6): 948-958, 2022 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-34964475

RESUMO

AIMS: Complexity of the ventricular tachycardia (VT) substrate and the size and thickness of infarction area border zones differ based on location of myocardial infarctions (MIs). These differences may translate into heterogeneity in the effectiveness of treatments. This study aims to examine the influence of infarct location on the effectiveness of VT ablation in comparison with escalated pharmacological therapy in patients with prior MI and antiarrhythmic drug (AAD)-refractory VT. METHODS AND RESULTS: VANISH trial participants were categorized based on the presence or absence of an inferior MI scar. Inverse probability of treatment weighted Cox models were calculated for each subgroup. Of 259 randomized patients (median age 69.8 years, 7.0% women), 135 had an inferior MI and 124 had a non-inferior MI. Among patients with an inferior MI, no statistically significant difference in the composite primary outcome of all-cause mortality, appropriate implantable cardioverter-defibrillator (ICD) shock, and VT storm was detected between treatment arms [adjusted hazard ratio (aHR) 0.80, 95% confidence interval (CI) 0.51-1.20]. In contrast, patients with non-inferior MIs had a statistically significant reduction in the incidence of the primary outcome with ablation (aHR 0.48, 95% CI 0.27-0.86). In a sensitivity analysis of anterior MI patients (n = 83), a trend towards a reduction in the primary outcome with ablation was detected (aHR 0.50, 95% CI 0.23-1.09). CONCLUSION: The effectiveness of VT ablation versus escalated AADs varies based on the location of the MI. Patients with MI scars located only in non-inferior regions of the ventricles derive greater benefit from VT ablation in comparison to escalation of AADs in reducing VT-related events.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Infarto do Miocárdio , Taquicardia Ventricular , Idoso , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/etiologia , Feminino , Humanos , Masculino , Infarto do Miocárdio/tratamento farmacológico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
14.
Europace ; 24(7): 1112-1118, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35030257

RESUMO

AIMS: Catheter ablation is superior to escalated antiarrhythmic drugs among patients with ventricular tachycardia (VT) and prior myocardial infarction (MI). However, it is uncertain whether clinical VT characteristics, should influence choice of therapy. The purpose of this study was to evaluate whether presentation with electrical storm and the clinical VT cycle length predicted response to ablation vs. escalated antiarrhythmic therapy. METHODS AND RESULTS: All patients enrolled in the Ventricular Tachycardia Ablation vs. Escalated Antiarrhythmic Drug Therapy in Ischaemic Heart Disease (VANISH) trial were included. The association between VT cycle length and presentation with electrical storm and the primary outcome of death, subsequent VT storm or appropriate ICD shock was evaluated. Among the study population of 259 patients, escalated antiarrhythmic drug therapy had worse outcomes for those presenting with a VT cycle length >400 ms [<150 b.p.m., 89/259, hazard ratio (HR) 1.7 (1.02-3.13)]. This effect was more pronounced among those taking amiodarone at baseline [HR of 2.22 (1.19-4.16)]. Presentation with VT storm (32/259) did not affect the primary outcome between groups. However, those presenting with VT storm on amiodarone had a trend towards worse outcomes with escalated antiarrhythmic therapy [HR 4.31 (0.55-33.93)]. CONCLUSION: The VT cycle length can influence response to either ablation or escalated drug therapy in patients with VT and prior MI. Those with slow VT had improved outcomes with ablation. Patients presenting with electrical storm demonstrated similar outcomes to the overall trial population, with a trend to benefit of catheter ablation, particularly in those on amiodarone.


Assuntos
Amiodarona , Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Ablação por Cateter/métodos , Humanos , Infarto do Miocárdio/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
15.
Europace ; 23(5): 748-756, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-33367623

RESUMO

AIMS: Post-operative pain following cardiac implantable electronic device (CIED) insertion is associated with patient dissatisfaction, emotional distress, and emergency department visits. We sought to identify factors associated with post-operative pain and develop a prediction score for post-operative pain. METHODS AND RESULTS: All patients from the BRUISE CONTROL-1 and 2 trials were included in this analysis. A validated Visual Analogue Scale (VAS) was used to assess the severity of pain related to CIED implant procedures. Patients were asked to grade the most severe post-operative pain, average post-operative pain, and pain on the day of the first post-operative clinic. Multivariable regression analyses were performed to identify predictors of significant post-operative pain and to develop a pain-prediction score. A total of 1308 patients were included. Multivariable regression analysis found that the presence of post-operative clinically significant haematoma {CSH; P value < 0.001; odds ratio (OR) 3.82 [95% confidence interval (CI): 2.37-6.16]}, de novo CIED implantation [P value < 0.001; OR 1.90 (95% CI: 1.47-2.46)], female sex [P value < 0.001; OR 1.61 (95% CI: 1.22-2.12)], younger age [<65 years; P value < 0.001; OR 1.54 (95% CI: 1.14-2.10)], and lower body mass index [<20 kg/m2; P value < 0.05; OR 2.05 (95% CI: 0.98-4.28)] demonstrated strong and independent associations with increased post-operative pain. An 11-point post-operative pain prediction score was developed using the data. CONCLUSION: Our study has identified multiple predictors of post-operative pain after CIED insertion. We have developed a prediction score for post-operative pain that can be used to identify individuals at risk of experiencing significant post-operative pain.


Assuntos
Contusões , Desfibriladores Implantáveis , Marca-Passo Artificial , Idoso , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Feminino , Humanos , Marca-Passo Artificial/efeitos adversos , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
16.
BMC Cardiovasc Disord ; 21(1): 445, 2021 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-34530738

RESUMO

BACKGROUND: Catheter ablation is an established therapy for atrial fibrillation but is limited by recurrence; efforts have been made to identify biomarkers that predict recurrence. We investigated the effect of baseline NT-proBNP on AF recurrence following catheter ablation in patients randomized to aggressive (< 120/80 mmHg) or standard blood pressure management (< 140/90 mmHg) in the Substrate Modification with Aggressive Blood Pressure Control trial (SMAC-AF). METHODS: The SMAC-AF study included 173 patients resistant or intolerant to at least one class I or III antiarrhythmic drug. We studied the effect of baseline NT-proBNP on the primary outcome of AF recurrence > 3 months post-ablation. RESULTS: Of the 173 patients, 88 were randomized to the aggressive cohort, and 85 into the standard group. The primary outcome occurred in 61.4% of those in the aggressive arm, versus 61.2% in the standard arm. In the aggressive group, logNT-proBNP predicted recurrence (HR 1.28, p = 0.04, adjusted HR 1.43, p = 0.03), while in the standard cohort, it did not (HR 0.94, p = 0.62, adjusted HR 0.83, p = 0.22). NT-proBNP ≥ 280 pg/mL also predicted occurrence in the aggressive (HR 1.98, p = 0.02) but not the standard cohort (HR 1.00, p = 1.00). CONCLUSION: We conclude that pre-ablation NT-proBNP may be useful in predicting recurrence in hypertensive patients and identifying patients who benefit from aggressive blood control and upstream therapies. TRIAL REGISTRATION: NCT00438113, registered February 21, 2007.


Assuntos
Anti-Hipertensivos/uso terapêutico , Fibrilação Atrial/cirurgia , Pressão Sanguínea/efeitos dos fármacos , Ablação por Cateter , Criocirurgia , Frequência Cardíaca , Hipertensão/tratamento farmacológico , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Potenciais de Ação , Idoso , Anti-Hipertensivos/efeitos adversos , Fibrilação Atrial/sangue , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Biomarcadores/sangue , Canadá , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Hipertensão/sangue , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Pacing Clin Electrophysiol ; 44(3): 432-441, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33527422

RESUMO

INTRODUCTION: We recently developed two noninvasive methodologies to help guide VT ablation: population-derived automated VT exit localization (PAVEL) and virtual-heart arrhythmia ablation targeting (VAAT). We hypothesized that while very different in their nature, limitations, and type of ablation targets (substrate-based vs. clinical VT), the image-based VAAT and the ECG-based PAVEL technologies would be spatially concordant in their predictions. OBJECTIVE: The objective is to test this hypothesis in ischemic cardiomyopathy patients in a retrospective feasibility study. METHODS: Four post-infarct patients who underwent LV VT ablation and had pre-procedural LGE-CMRs were enrolled. Virtual hearts with patient-specific scar and border zone identified potential VTs and ablation targets. Patient-specific PAVEL based on a population-derived statistical method localized VT exit sites onto a patient-specific 238-triangle LV endocardial surface. RESULTS: Ten induced VTs were analyzed and 9-exit sites were localized by PAVEL onto the patient-specific LV endocardial surface. All nine predicted VT exit sites were in the scar border zone defined by voltage mapping and spatially correlated with successful clinical lesions. There were 2.3 ± 1.9 VTs per patient in the models. All five VAAT lesions fell within regions ablated clinically. VAAT targets correlated well with 6 PAVEL-predicted VT exit sites. The distance between the center of the predicted VT-exit-site triangle and nearest corresponding VAAT ablation lesion was 10.7 ± 7.3 mm. CONCLUSIONS: VAAT targets are concordant with the patient-specific PAVEL-predicted VT exit sites. These findings support investigation into combining these two complementary technologies as a noninvasive, clinical tool for targeting clinically induced VTs and regions likely to harbor potential VTs.


Assuntos
Ablação por Cateter/métodos , Isquemia Miocárdica/cirurgia , Taquicardia Ventricular/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem
18.
Circulation ; 140(22): 1779-1788, 2019 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-31630538

RESUMO

BACKGROUND: Advanced generation ablation technologies have been developed to achieve more effective pulmonary vein isolation (PVI) and minimize arrhythmia recurrence after atrial fibrillation (AF) ablation. METHODS: We randomly assigned 346 patients with drug-refractory paroxysmal AF to contact force-guided radiofrequency ablation (CF-RF; n=115), 4-minute cryoballoon ablation (Cryo-4; n=115), or 2-minute cryoballoon ablation (Cryo-2; n=116). Follow-up was 12 months. The primary outcome was time to first documented recurrence of symptomatic or asymptomatic atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia) between days 91 and 365 after ablation or a repeat ablation procedure at any time. Secondary end points included freedom from symptomatic arrhythmia and AF burden. All patients received an implantable loop recorder. RESULTS: One-year freedom from atrial tachyarrhythmia defined by continuous rhythm monitoring was 53.9%, 52.2%, and 51.7% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.87). One-year freedom from symptomatic atrial tachyarrhythmia defined by continuous rhythm monitoring was 79.1%, 78.2%, and 73.3% with CF-RF, Cryo-4, and Cryo-2, respectively (P=0.26). Compared with the monitoring period before ablation, AF burden was reduced by a median of 99.3% (interquartile range, 67.8%-100.0%) with CF-RF, 99.9% (interquartile range, 65.3%-100.0%) with Cryo-4, and 98.4% (interquartile range, 56.2%-100.0%) with Cryo-2 (P=0.36). Serious adverse events occurred in 3 patients (2.6%) in the CF-RF group, 6 patients (5.3%) in the Cryo-4 group, and 7 patients (6.0%) in the Cryo-2 group, with no significant difference between groups (P=0.24). The CF-RF group had a significantly longer procedure duration but significantly shorter fluoroscopy exposure (P<0.001 vs cryoballoon groups). CONCLUSIONS: In this multicenter, randomized, single-blinded trial, CF-RF and 2 different regimens of cryoballoon ablation resulted in no difference in 1-year efficacy, which was 53% by time to first recurrence but >98% burden reduction as assessed by continuous cardiac rhythm monitoring. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01913522.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Feminino , Fluoroscopia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
19.
Artigo em Inglês | MEDLINE | ID: mdl-32627264

RESUMO

BACKGROUND: Concerns remain regarding the effectiveness of PVI using the fixed diameter non-compliant cryoballoon in the presence of a left common pulmonary vein (LCPV). We sought to evaluate the effectiveness of PVI performed by contact-force guided radiofrequency (CF-RF) versus second-generation cryoballoon-based ablation in patients with LCPV. METHODS AND RESULTS: We enrolled 346 patients with paroxysmal AF and randomized them to CF-RF or cryoballoon ablation. PV anatomy was not assessed prior to enrolment, and there were no exclusions based on PV anatomy. All patients received an implantable cardiac monitor. LCPV was observed in 13.6% of patients (47/346). Left atrial time and fluoroscopy time did not differ between those with and without LCPV (P=0.58 and P=0.06, respectively). Freedom from any atrial tachyarrhythmia at one year was observed in 46.8% with LCPV and 54.5% without LCPV (P=0.06). In those with LCPV the freedom from any atrial tachyarrhythmia did not differ between those randomized to CF-RF or cryoballoon ablation (HR for recurrence 1.19, 95% CI 0.53-2.65, P=0.69). In those with LCPV the AF burden was reduced to a similar extent with CF-RF and cryoballoon ablation (99.7% vs. 99.5%, respectively; P=0.97). CONCLUSIONS: In this randomized clinical trial, the presence of a LCPV was associated with a trend towards higher rates of arrhythmia recurrence following PVI. No significant difference in arrhythmia recurrence was observed between patients with LCPV randomized to cryoballoon ablation or contact-force guided RF ablation, suggesting that either ablation modality is suitable in this population. (Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation [CIRCA-DOSE], NCT01913522) This article is protected by copyright. All rights reserved.

20.
Curr Opin Cardiol ; 35(2): 138-144, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31895241

RESUMO

PURPOSE OF REVIEW: Patients with heart failure are at increased risk of sudden cardiac death. The methods to predict patients at high risk of sudden cardiac death in heart failure are neither sensitive nor specific; both overestimating risk in those with ejection fractions less than 35% and not identifying those at risk with ejection fractions greater than 35%. RECENT FINDINGS: The absolute risk of sudden cardiac death in patients with heart failure have decreased over the past 20 years. New novel tools are being developed and tested to identify those at higher risk of sudden cardiac death. Reduction in the risk of sudden cardiac death has been achieved with the use of beta-blockers, spironolactone, sacubitril-valsartan, cardiac resynchronization and implantable cardioverter defibrillators. SUMMARY: The use of contemporary treatments for patients with heart failure can reduce the risk of sudden cardiac death, but research is required to identify those at highest risk.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca/complicações , Disfunção Ventricular Esquerda , Morte Súbita Cardíaca/prevenção & controle , Humanos , Volume Sistólico
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa