Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-24704687

RESUMO

A rapid quantification method of diclofenac from sludge samples through ultrasonication assisted extraction and solid phase extraction (SPE) was developed and used for the quantification of diclofenac concentrations in sludge samples with liquid chromatography/tandem mass spectrometry (LC-MS/MS). Although the concentration of diclofenac in sludge samples taken from different units of wastewater treatment plants in Istanbul was below the limit of quantification (LOQ; 5ng/g), an optimized method for sludge samples along with the total mass balances in a wastewater treatment plant can be used to determine the phase with which diclofenac is mostly associated. Hence, the results will provide information on fate and transport of diclofenac, as well as on the necessity of alternative removal processes. In addition, since the optimization procedure is provided in detail, it is possible for other researchers to use this procedure as a starting point for the determination of other emerging pollutants in wastewater sludge samples.


Assuntos
Diclofenaco/isolamento & purificação , Esgotos/análise , Extração em Fase Sólida/métodos , Sonicação/métodos , Poluentes Químicos da Água/isolamento & purificação , Cromatografia Líquida/métodos , Limite de Detecção , Espectrometria de Massas em Tandem/métodos , Águas Residuárias/análise
2.
J Hazard Mater ; 272: 155-64, 2014 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-24709411

RESUMO

The pharmaceutically active compound diclofenac has been monitored during one year at separate treatment units of two municipal wastewater treatment plants (WWTPs) to evaluate its seasonal variation and the removal efficiency. Conventional wastewater characterization was also performed to assess the possible relationship between conventional parameters and diclofenac. Diclofenac concentrations in the influent and effluent of both WWTPs were detected in the range of 295-1376 and 119-1012ng/L, respectively. Results indicated that the higher diclofenac removal efficiency was observed in summer season in both WWTPs. Although a consistency in diclofenac removal was observed in WWTP_1, significant fluctuation was observed at WWTP_2 based on seasonal evaluation. The main removal mechanism of diclofenac in the WWTPs was most often biological (55%), followed by UV disinfection (27%). When diclofenac removal was evaluated in terms of the treatment units in WWTPs, a significant increase was achieved at the treatment plant including UV disinfection unit. Based on the statistical analysis, higher correlation was observed between diclofenac and suspended solids concentrations among conventional parameters in the influent whereas the removal of diclofenac was highly correlated with nitrogen removal efficiency.


Assuntos
Diclofenaco/química , Estações do Ano , Poluentes Químicos da Água/química , Purificação da Água/métodos , Nitrogênio/química , Turquia , Raios Ultravioleta , Eliminação de Resíduos Líquidos/métodos , Águas Residuárias/química
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa