Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
Curr Cardiol Rep ; 26(5): 393-404, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38526749

RESUMO

PURPOSE OF REVIEW: Although rare, the development of mechanical complications following an acute myocardial infarction is associated with a high morbidity and mortality. Here, we review the clinical features, diagnostic strategy, and treatment options for each of the mechanical complications, with a focus on the role of echocardiography. RECENT FINDINGS: The growth of percutaneous structural interventions worldwide has given rise to new non-surgical options for management of mechanical complications. As such, select patients may benefit from a novel use of these established treatment methods. A thorough understanding of the two-dimensional, three-dimensional, color Doppler, and spectral Doppler findings for each mechanical complication is essential in recognizing major causes of hemodynamic decompensation after an acute myocardial infarction. Thereafter, echocardiography can aid in the selection and maintenance of mechanical circulatory support and potentially facilitate the use of a percutaneous intervention.


Assuntos
Infarto do Miocárdio , Humanos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/complicações , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea , Coração Auxiliar/efeitos adversos , Ecocardiografia/métodos , Ecocardiografia Doppler em Cores
2.
Curr Cardiol Rep ; 25(3): 97-107, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36680732

RESUMO

PURPOSE OF REVIEW: Percutaneous structural interventions have provided patients with an effective therapeutic option, and its growth has been aided by echocardiography. We describe the vital role that transesophageal echocardiography (TEE) plays in screening patients prior to their procedure. RECENT FINDINGS: A multimodality imaging approach is employed by the valve team, but TEE plays a unique role in diagnosis and planning. Utilization of all TEE views and features such as biplane, 3D imaging, and multiplanar reconstruction ensures accurate assessment of the structural lesion of interest. The role of TEE remains essential in the planning of structural interventions, and these studies should be performed in a systematic and comprehensive manner.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ecocardiografia Tridimensional , Humanos , Ecocardiografia Transesofagiana/métodos , Ecocardiografia Tridimensional/métodos , Imagem Multimodal
3.
Echocardiography ; 39(10): 1348-1358, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36198094

RESUMO

INTRODUCTION: Gram-negative organisms of the AACEK group, formerly known as HACEK, rarely cause endocarditis. CASE SERIES: We present three cases of bacterial endocarditis, involving native and prosthetic valves, caused by AACEK organisms. In two patients, Cardiobacterium hominis was the responsible organism, and in a third, Aggregatibacter aphrophilus was implicated. A dental source of infection was identified in two patients, and in all three patients, the presentation of endocarditis was subacute. DISCUSSION: This case series highlights the indolent nature of infection with the AACEK organisms. It also demonstrates the crucial role of multimodality imaging, especially transesophageal echocardiography, in the diagnosis of AACEk endocarditis of both native and prosthetic valves, and in delineating the extent of abscess in those with prosthetic valve infection.


Assuntos
Endocardite Bacteriana , Endocardite , Humanos , Endocardite Bacteriana/diagnóstico , Endocardite Bacteriana/diagnóstico por imagem , Ecocardiografia Transesofagiana
4.
Echocardiography ; 39(1): 112-117, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34923683

RESUMO

Infective endocarditis (IE) is a life-threatening disease associated with in-hospital mortality of nearly one in five cases. IE can destroy valvular tissue, which may rarely progress to aneurysm formation, most commonly at the anterior leaflet in instances of mitral valve involvement. We present a remarkable case of a patient with IE and a rare complication of a ruptured aneurysm of the posterior leaflet of the mitral valve. Two- and Three-dimensional transesophageal echocardiography, intra-operative videography, and histopathologic analysis revealed disruption at this unusual location-at the junction of the P2 and P3 scallops, surrounded by an annular abscess.


Assuntos
Aneurisma Roto , Endocardite Bacteriana , Endocardite , Aneurisma Cardíaco , Insuficiência da Valva Mitral , Aneurisma Roto/complicações , Aneurisma Roto/diagnóstico por imagem , Ecocardiografia Transesofagiana/métodos , Endocardite/complicações , Endocardite/diagnóstico por imagem , Endocardite Bacteriana/complicações , Endocardite Bacteriana/diagnóstico por imagem , Aneurisma Cardíaco/complicações , Aneurisma Cardíaco/diagnóstico por imagem , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Staphylococcus
5.
Crit Care Med ; 49(8): 1285-1292, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33730745

RESUMO

OBJECTIVES: To describe the development and initial results of an examination and certification process assessing competence in critical care echocardiography. DESIGN: A test writing committee of content experts from eight professional societies invested in critical care echocardiography was convened, with the Executive Director representing the National Board of Echocardiography. Using an examination content outline, the writing committee was assigned topics relevant to their areas of expertise. The examination items underwent extensive review, editing, and discussion in several face-to-face meetings supervised by National Board of Medical Examiners editors and psychometricians. A separate certification committee was tasked with establishing criteria required to achieve National Board of Echocardiography certification in critical care echocardiography through detailed review of required supporting material submitted by candidates seeking to fulfill these criteria. SETTING: The writing committee met twice a year in person at the National Board of Medical Examiner office in Philadelphia, PA. SUBJECTS: Physicians enrolled in the examination of Special Competence in Critical Care Electrocardiography (CCEeXAM). MEASUREMENTS AND MAIN RESULTS: A total of 524 physicians sat for the examination, and 426 (81.3%) achieved a passing score. Of the examinees, 41% were anesthesiology trained, 33.2% had pulmonary/critical care background, and the majority had graduated training within the 10 years (91.6%). Most candidates work full-time at an academic hospital (46.9%). CONCLUSIONS: The CCEeXAM is designed to assess a knowledge base that is shared with echocardiologists in addition to that which is unique to critical care. The National Board of Echocardiography certification establishes that the physician has achieved the ability to independently perform and interpret critical care echocardiography at a standard recognized by critical care professional societies encompassing a wide spectrum of backgrounds. The interest shown and the success achieved on the CCEeXAM by practitioners of critical care echocardiography support the standards set by the National Board of Echocardiography for testamur status and certification in this imaging specialty area.


Assuntos
Certificação/normas , Competência Clínica/normas , Cuidados Críticos/normas , Ecocardiografia/normas , Medicina Interna/normas , Avaliação Educacional , Humanos , Conselhos de Especialidade Profissional
6.
Catheter Cardiovasc Interv ; 98(2): 319-327, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33180381

RESUMO

BACKGROUND: Patients with renal insufficiency have poor short-term outcomes after transcatheter aortic valve replacement (TAVR). METHODS: Retrospective chart review identified 575 consecutive patients not on hemodialysis who underwent TAVR between September 2014 and January 2017. Outcomes were defined by VARC-2 criteria. Primary outcome of all-cause mortality was evaluated at a median follow-up of 811 days (interquartile range 125-1,151). RESULTS: Preprocedural glomerular filtration rate (GFR) was ≥60 ml/min in 51.7%, 30-60 ml/min in 42.1%, and < 30 ml/min in 6.3%. Use of transfemoral access (98.8%) and achieved device success (91.0%) did not differ among groups, but less contrast was used with lower GFR (23 ml [15-33], 24 ml [14-33], 13 ml [8-20]; p < .001). Peri-procedural stroke (0.7%, 2.1%, 11.1%; p < .001) was higher with lower GFR. Core lab analysis of preprocedural computed tomography scans of patients who developed a peri-procedural stroke identified potential anatomic substrate for stroke in three out of four patients with GFR 30-60 ml/min and all three with GFR <30 ml/min (severe atheroma was the most common subtype of anatomical substrate present). Compared to GFR ≥60 ml/min, all-cause mortality was higher with GFR 30-60 ml/min (HR 1.61 [1.00-2.59]; aHR 1.61 [0.91-2.83]) and GFR <30 ml/min (HR 2.41 [1.06-5.48]; aHR 2.34 [0.90-6.09]) but not significant after multivariable adjustment. Follow-up echocardiographic data, available in 63%, demonstrated no difference in structural heart valve deterioration over time among groups. CONCLUSIONS: Patients with baseline renal insufficiency remain a challenging population with poor long-term outcomes despite procedural optimization with a transfemoral-first and an extremely low-contrast approach.


Assuntos
Estenose da Valva Aórtica , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
7.
Echocardiography ; 38(3): 446-449, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33586797

RESUMO

PURPOSE: The coronavirus disease-2019 (COVID-19) led to a large influx of critically ill patients and altered echocardiography laboratory workflow. We developed a point-of-care ultrasound (POCUS) first approach to patients requiring echocardiography and describe our workflow and findings. METHODS: We performed a single-center retrospective analysis of all POCUS studies performed on critically ill patients with COVID-19. Sonography was performed by intensivists, uploaded and archived, and rapidly reviewed by echocardiographers. We evaluated each study based on the number of views obtained. Additionally, we provide a description of the workflow during the COVID-19 surge at a tertiary care hospital in New York City. RESULTS: Fifty patients had POCUS studies performed by intensivists and reviewed by echocardiographers obviating the need for sonographer-performed studies. Of the 48 cardiac POCUS studies, 17% of patients had 4 of 4 standard views available while 53% had 3 of 4 standard views. The parasternal long-axis view was obtained on 81%, subxiphoid view on 79%, apical 4-chamber view on 71%, and parasternal short-axis view on 63% of patients. CONCLUSIONS: Our POCUS workflow allowed intensivists to perform cardiac sonography for rapid bedside diagnosis of pathology with immediate interpretation performed by echocardiographers. At least 3 views were obtained in the majority of cases.


Assuntos
COVID-19/epidemiologia , Estado Terminal , Ecocardiografia/métodos , Cardiopatias/diagnóstico , Pandemias , Testes Imediatos/organização & administração , Comorbidade , Cardiopatias/epidemiologia , Humanos , Estudos Retrospectivos
8.
Echocardiography ; 38(5): 798-804, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33715241

RESUMO

The COVID-19 pandemic has presented countless new challenges for healthcare providers including the challenge of differentiating COVID-19 infection from other diseases. COVID-19 infection and acute endocarditis may present similarly, both with shortness of breath and vital sign abnormalities, yet they require very different treatments. Here, we present two cases in which life-threatening acute endocarditis was initially misdiagnosed as COVID-19 infection during the height of the pandemic in New York City. The first was a case of Klebsiella pneumoniae mitral valve endocarditis leading to papillary muscle rupture and severe mitral regurgitation, and the second a case of Streptococcus mitis aortic valve endocarditis with heart failure due to severe aortic regurgitation. These cases highlight the importance of careful clinical reasoning and demonstrate how cognitive errors may impact clinical reasoning. They also underscore the limitations of real-time reverse transcription-polymerase chain reaction (RT-PCR) for SARS-CoV-2 testing and illustrate the ways in which difficulty interpreting results may also influence clinical reasoning. Accurate diagnosis of acute endocarditis is critical given that surgical intervention can be lifesaving in unstable patients.


Assuntos
COVID-19 , Endocardite Bacteriana , Endocardite , Próteses Valvulares Cardíacas , Valva Aórtica , Teste para COVID-19 , Erros de Diagnóstico , Endocardite Bacteriana/diagnóstico , Humanos , Pandemias , SARS-CoV-2
9.
J Clin Ultrasound ; 49(7): 644-649, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33665868

RESUMO

PURPOSE: The purpose of this study was to investigate the diagnostic potential of the aortic closure (A2) signal length on Doppler echocardiography in distinguishing aortic patient-prosthesis mismatch (PPM) from prosthetic stenosis among patients with elevated gradients over bioprosthetic valves. METHODS: The A2 signal length was retrospectively measured for 150 patients with bioprosthetic aortic valves (50 with PPM, 50 with prosthetic stenosis, and 50 with normally functioning valves) from transthoracic echocardiograms performed at NYU Langone Health between 01/01/2012 and 08/01/2018. RESULTS: Mean A2 signal length was shorter among patients with PPM (11.1 ms ± 5.2 ms), than among those with prosthetic stenosis (21.1 ms ± 6.0 ms), P < .001 and controls (21.7 ms ± 7.4 ms), P < .001. There was no difference in A2 signal length between prosthetic stenosis and controls. The A2 signal length yielded an AUC of 0.89 (95% CI 0.82-0.95) for predicting PPM over prosthetic stenosis. CONCLUSION: Among patients with bioprosthetic aortic valves, the length of the A2 signal on Doppler echocardiography is shorter in PPM than in prosthetic stenosis and normally functioning valves. The A2 signal length may represent a novel metric to distinguish PPM from prosthetic stenosis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Constrição Patológica , Ecocardiografia Doppler , Humanos , Desenho de Prótese , Estudos Retrospectivos
10.
J Nucl Cardiol ; 27(2): 410-416, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31975328

RESUMO

The 2019 American College of Cardiology Scientific Sessions displayed innovation in many areas for the evaluation and management of cardiovascular disease from preventive evaluation and care to advanced interventions. Imaging played a central role in these developments with a highlight of the conference being the imaging research presented. This review will summarize key imaging studies which were presented at this scientific meeting which will lead to innovation in the evaluation and management of cardiovascular disease. Experts in nuclear imaging (DW/MA), echocardiography (MS), cardiac magnetic resonance (SL), and cardiac computed tomography (RB) selected abstracts which they found to be of particular interest to the multimodality imaging audience and were integrated into this review (LP).


Assuntos
Cardiologia/tendências , Doenças Cardiovasculares/diagnóstico por imagem , Ecocardiografia/métodos , Coração/diagnóstico por imagem , Imagem Multimodal/tendências , Tomografia por Emissão de Pósitrons/métodos , Cardiologia/métodos , Congressos como Assunto , Diagnóstico por Imagem , Humanos , Valva Mitral/diagnóstico por imagem , Imagem Multimodal/métodos , Medicina Nuclear , Intervenção Coronária Percutânea/métodos , Risco , Sociedades Médicas , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
11.
Echocardiography ; 37(7): 1072-1076, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32654168

RESUMO

We report what appears to be the first case of biopsy-proven nonvalvular endocarditis with biventricular apical infected thrombi. A 47-year-old man presented with hypoxic respiratory failure from a multilobar pneumonia due to methicillin-resistant Staphylococcus aureus (MRSA). Transthoracic echocardiography and cardiac magnetic resonance imaging revealed biventricular apical masses suggestive of nonvalvular endocarditis with infected thrombi. Given concern for ongoing septic embolization to the lungs and brain despite appropriate antimicrobial therapy, the masses were surgically resected. Culture and histopathology confirmed MRSA-positive infected thrombi. In this case report, we highlight the differential diagnosis of apical masses and the role of multimodality imaging.


Assuntos
Endocardite , Staphylococcus aureus Resistente à Meticilina , Trombose , Ecocardiografia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Trombose/diagnóstico , Trombose/diagnóstico por imagem
12.
Echocardiography ; 36(8): 1601-1604, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31385344

RESUMO

Recent improvements in 3D TEE post processing rendering techniques referred to as TrueVue (Philips Medical Systems, Andover, MA, USA). It allows for novel photorealistic imaging of cardiac structures including left atrial appendage (LAA) and its closure devices. Here we present TrueVue images of the LAA prior to and after LAA exclusion/occlusion using various percutaneous and surgical techniques. TrueVue may improve delineation of LAA anatomy prior to occlusion as well as visualization of occluder device position within the LAA.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana/métodos , Dispositivo para Oclusão Septal , Cirurgia Assistida por Computador/métodos , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Ecocardiografia Tridimensional/métodos , Humanos
13.
Echocardiography ; 36(8): 1586-1589, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31246314

RESUMO

A 51-year-old man with Klippel-Feil syndrome (KFS) and immunodeficiency syndrome, status postintravenous immunoglobulin therapy, presented with shortness of breath. He was found to have severe aortic regurgitation in the setting of a trileaflet aortic valve with thickened leaflets and mild prolapse of the right coronary cusp with left ventricular dilation and borderline left ventricular ejection fraction. Although various cardiac anomalies have been described in KPS, otherwise unexplained severe aortic regurgitation has not been previously reported to the best of our knowledge. The patient underwent an uncomplicated surgical aortic valve replacement with a 25-mm Medtronic Avalus pericardial tissue valve resulting in symptomatic improvement. Intra-operative management and transesophageal echocardiography can be particularly challenging in KFS patients. We describe the first reported case of severe aortic regurgitation in KPS, review the cardiac anomalies associated with the syndrome, and highlight the clinical challenges in intra-operative management of these patients.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Ecocardiografia Transesofagiana/métodos , Imageamento Tridimensional/métodos , Síndrome de Klippel-Feil/complicações , Imagem Multimodal , Tomografia Computadorizada por Raios X/métodos , Valva Aórtica , Insuficiência da Valva Aórtica/diagnóstico , Diagnóstico Diferencial , Humanos , Síndrome de Klippel-Feil/diagnóstico , Masculino , Pessoa de Meia-Idade
14.
Echocardiography ; 36(1): 47-60, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30548699

RESUMO

BACKGROUND: Acute left ventricular (LV) apical ballooning with normal coronary angiography occurs rarely in obstructive hypertrophic cardiomyopathy (OHCM); it may be associated with severe hemodynamic instability. METHODS, RESULTS: We searched for acute LV ballooning with apical hypokinesia/akinesia in databases of two HCM treatment programs. Diagnosis of OHCM was made by conventional criteria of LV hypertrophy in the absence of a clinical cause for hypertrophy and mitral-septal contact. Among 1519 patients, we observed acute LV ballooning in 13 (0.9%), associated with dynamic left ventricular outflow tract (LVOT) obstruction and high gradients, 92 ± 37 mm Hg, 10 female (77%), age 64 ± 7 years, LVEF 31.6 ± 10%. Septal hypertrophy was mild compared to that of the rest of our HCM cohort, 15 vs 20 mm (P < 0.00001). An elongated anterior mitral leaflet or anteriorly displaced papillary muscles occurred in 77%. Course was complicated by cardiogenic shock and heart failure in 5, and refractory heart failure in 1. High-dose beta-blockade was the mainstay of therapy. Three patients required urgent surgical relief of LVOT obstruction, 2 for refractory cardiogenic shock, and one for refractory heart failure. In the three patients, surgery immediately normalized refractory severe LV dysfunction, and immediately reversed cardiogenic shock and heart failure. All have normal LV systolic function at 45-month follow-up, and all have survived. CONCLUSIONS: Acute LV apical ballooning, associated with high dynamic LVOT gradients, may punctuate the course of obstructive HCM. The syndrome is important to recognize on echocardiography because it may be associated with profound reversible LV decompensation.


Assuntos
Cardiomiopatia Hipertrófica/complicações , Ventrículos do Coração/diagnóstico por imagem , Hipertrofia Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/complicações , Obstrução do Fluxo Ventricular Externo/complicações , Ecocardiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
15.
Curr Cardiol Rep ; 21(7): 66, 2019 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-31183616

RESUMO

PURPOSE OF REVIEW: Atrial fibrillation is the most common arrhythmia worldwide and is a major risk factor for embolic stroke. For patients with atrial fibrillation who are unable to tolerate systemic anticoagulation, left atrial appendage (LAA) occlusion has been shown to mitigate stroke risk. In this article, we describe the vital role of the echocardiographer in intraprocedural guidance of percutaneous LAA occlusion procedures as well as in the pre- and post-procedure assessment of these patients. RECENT FINDINGS: A few percutaneously delivered devices for LAA exclusion from the systemic circulation are available in contemporary practice. These devices employ an either exclusive endocardial LAA occlusion approach, such as the Watchman (Boston Scientific, Maple Grove, MN) and Amulet (St. Jude Medical, Minneapolis, MN), or both an endocardial and pericardial (epicardial) approach such as the Lariat procedure (SentreHEART, Palo Alto, CA). Two- and three-dimension transesophageal echocardiography is critical for patient selection, procedure planning, procedural guidance, and ensuring satisfactory immediate as well as long-term LAA occlusion/exclusion efficacy. This review will provide an overview of the role of the echocardiographer in all aspects of LAA occlusion/exclusion procedures for the most commonly used commercially available devices in current practice.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia Transesofagiana/métodos , Cirurgia Assistida por Computador/métodos , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico , Átrios do Coração , Humanos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
16.
J Interv Cardiol ; 31(6): 849-860, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30203608

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for low gradient (LG) severe aortic stenosis (AS) with preserved left ventricular ejection fraction (LVEF) remains an area of clinical uncertainty. METHODS: Retrospective review identified 422 patients who underwent TAVR between September 4, 2014 and July 1, 2016. Procedural indication other than severe AS (n = 22) or LVEF <50% (n = 98) were excluded. Outcomes were defined by valve academic research consortium two criteria when applicable and compared between LG (peak velocity <4.0 m/s and mean gradient <40 mmHg; n = 73) and high gradient (HG) (n = 229) groups. The LG group was further categorized as low stroke volume index (SVI) (n = 41) or normal SVI (n = 32). Median follow-up was 747 days [interquartile range 220-1013]. RESULTS: Baseline thirty-day mortality risk (LG 6.2% [3.8-8.1] vs HG 5.7% [4.1-7.4], P = 0.43) did not differ between groups. Short-term outcomes, including procedural success rate (86.1% vs 88.8%, P = 0.53), peri-procedural complications (intra-procedural heart block: 6.8% vs 7.9%, P = 0.99; permanent pacemaker placement: 11.0% vs 13.6%, P = 0.69; moderate paravalvular regurgitation: 2.7% vs 1.3%, P = 0.60), and all-cause in-hospital mortality (2.7% vs 0.9%, P = 0.25) did not differ between LG and HG groups. On long-term follow-up, all-cause mortality also did not differ between LG and HG groups (6.8% vs 10.0%, plog-rank = 0.33) or between the LG low SVI (9.8%), LG normal SVI (3.1%), and HG (10.0%) groups (plog-rank = 0.39). CONCLUSION: Patients with preserved LVEF undergoing TAVR for severe AS with LG, including LG with low SVI, have no significant difference in adverse outcomes when compared to patients with HG.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
17.
Echocardiography ; 35(9): 1388-1401, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30079966

RESUMO

Echocardiography has become a critical tool in clinical cardiology in evaluating cardiac physiology and diagnosing cardiac disease states. However, imaging artifacts are commonly encountered and often lead to misdiagnoses of life-threatening diseases, such as aortic dissection and ventricular thrombus. It is, thus, critical for clinicians to understand these artifacts to avoid these misdiagnoses and protect patients from undue intervention. Artifacts can be broken down into two categories: those from violation of ultrasound system assumptions and those from interference by external equipment and devices. This review article discusses the most commonly encountered artifacts by category, explains their physical mechanisms, elaborates on their most common presentations, and instructs clinicians on how to avoid their misinterpretation.


Assuntos
Artefatos , Erros de Diagnóstico/prevenção & controle , Ecocardiografia/métodos , Cardiopatias/diagnóstico por imagem , Humanos
19.
Echocardiography ; 35(10): 1684-1691, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30136740

RESUMO

Partial anomalous pulmonary venous return (PAPVR) comprises a group of congenital cardiovascular anomalies associated with pulmonary venous flow directly or indirectly into the right atrium. Scimitar syndrome is a variant of PAPVR in which the right lung is drained by right pulmonary veins connected anomalously to the inferior vena cava. Surgery is the definitive treatment for scimitar syndrome. However, it is not always necessary as many patients are asymptomatic, have small left-to-right shunts, and enjoy a normal life expectancy without surgery. We report multimodality imaging in four adults with scimitar syndrome and the implications for management of this rare syndrome.


Assuntos
Diagnóstico por Imagem/métodos , Imagem Multimodal/métodos , Veias Pulmonares/diagnóstico por imagem , Síndrome de Cimitarra/diagnóstico por imagem , Veia Cava Inferior/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiografia , Tomografia Computadorizada por Raios X
20.
Echocardiography ; 35(12): 1939-1946, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30315597

RESUMO

BACKGROUND: Studies have demonstrated the value of transthoracic echocardiogram (TTE) diastolic parameters in predicting left atrial appendage (LAA) thrombus; however, these studies have been small. We aim to clarify the relationship between TTE diastolic parameters, in particular average e', and LAA thrombus or sludge. METHODS: A case-control review was conducted of subjects with non-valvular atrial fibrillation (n = 2263) who had undergone TEE (transesophageal echocardiogram) and had a TTE within 1 year of TEE. Cases of LAA sludge or thrombus were matched to controls by age, sex, left ventricular ejection fraction (LVEF), and anticoagulation status. RESULTS: Forty-three subjects (mean age 73 ± 12, 65% male, LVEF 47%, 44% on anticoagulation) with LAA sludge or thrombus were identified. Compared to matched controls, average TTE e' (7.3 ± 2.1 cm/s vs 8.7 ± 2.1 cm/s, P < 0.001) and the E:e' ratio (15 ± 7 cm/s vs 12 ± 5 cm/s; P = 0.005) were significant predictors of LAA sludge or thrombus. Average TTE e' value of >11 cm/s had 100% sensitivity for ruling out LAA sludge or thrombus. CONCLUSION: In individuals with atrial fibrillation, average e' >11 cm/s on TTE is a promising independent predictor of the absence of LAA sludge or thrombus on TEE.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Transesofagiana/métodos , Cardiopatias/diagnóstico , Trombose/diagnóstico , Função Ventricular Esquerda/fisiologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ecocardiografia Doppler , Feminino , Seguimentos , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Trombose/etiologia , Trombose/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa