Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Radiology ; 311(2): e231921, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38805732

RESUMO

Background Many clinically relevant fractures are occult on conventional radiographs and therefore challenging to diagnose reliably. X-ray dark-field radiography is a developing method that uses x-ray scattering as an additional signal source. Purpose To investigate whether x-ray dark-field radiography enhances the depiction of radiographically occult fractures in an experimental model compared with attenuation-based radiography alone and whether the directional dependence of dark-field signal impacts observer ratings. Materials and Methods Four porcine loin ribs had nondisplaced fractures experimentally introduced. Microstructural changes were visually verified using high-spatial-resolution three-dimensional micro-CT. X-ray dark-field radiographs were obtained before and after fracture, with the before-fracture scans serving as control images. The presence of a fracture was scored by three observers using a six-point scale (6, surely; 5, very likely; 4, likely; 3, unlikely; 2, very unlikely; and 1, certainly not). Differences between scores based on attenuation radiographs alone (n = 96) and based on combined attenuation and dark-field radiographs (n = 96) were evaluated by using the DeLong method to compare areas under the receiver operating characteristic curve. The impact of the dark-field signal directional sensitivity on observer ratings was evaluated using the Wilcoxon test. The dark-field data were split into four groups (24 images per group) according to their sensitivity orientation and tested against each other. Musculoskeletal dark-field radiography was further demonstrated on human finger and foot specimens. Results The addition of dark-field radiographs was found to increase the area under the receiver operating characteristic curve to 1 compared with an area under the receiver operating characteristic curve of 0.87 (95% CI: 0.80, 0.94) using attenuation-based radiographs alone (P < .001). There were similar observer ratings for the four different dark-field sensitivity orientations (P = .16-.65 between the groups). Conclusion These results suggested that the inclusion of dark-field radiography has the potential to help enhance the detection of nondisplaced fractures compared with attenuation-based radiography alone. © RSNA, 2024 See also the editorial by Rubin in this issue.


Assuntos
Estudos de Viabilidade , Animais , Suínos , Microtomografia por Raio-X/métodos , Fraturas das Costelas/diagnóstico por imagem , Fraturas Fechadas/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos
2.
World J Urol ; 42(1): 290, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702557

RESUMO

PURPOSE: mpMRI is routinely used to stratify the risk of clinically significant prostate cancer (csPCa) in men with elevated PSA values before biopsy. This study aimed to calculate a multivariable risk model incorporating standard risk factors and mpMRI findings for predicting csPCa on subsequent prostate biopsy. METHODS: Data from 677 patients undergoing mpMRI ultrasound fusion biopsy of the prostate at the TUM University Hospital tertiary urological center between 2019 and 2023 were analyzed. Patient age at biopsy (67 (median); 33-88 (range) (years)), PSA (7.2; 0.3-439 (ng/ml)), prostate volume (45; 10-300 (ml)), PSA density (0.15; 0.01-8.4), PI-RADS (V.2.0 protocol) score of index lesion (92.2% ≥3), prior negative biopsy (12.9%), suspicious digital rectal examination (31.2%), biopsy cores taken (12; 2-22), and pathological biopsy outcome were analyzed with multivariable logistic regression for independent associations with the detection of csPCa defined as ISUP ≥ 3 (n = 212 (35.2%)) and ISUP ≥ 2 (n = 459 (67.8%) performed on 603 patients with complete information. RESULTS: Older age (OR: 1.64 for a 10-year increase; p < 0.001), higher PSA density (OR: 1.60 for a doubling; p < 0.001), higher PI-RADS score of the index lesion (OR: 2.35 for an increase of 1; p < 0.001), and a prior negative biopsy (OR: 0.43; p = 0.01) were associated with csPCa. CONCLUSION: mpMRI findings are the dominant predictor for csPCa on follow-up prostate biopsy. However, PSA density, age, and prior negative biopsy history are independent predictors. They must be considered when discussing the individual risk for csPCa following suspicious mpMRI and may help facilitate the further diagnostical approach.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Masculino , Neoplasias da Próstata/patologia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/sangue , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Adulto , Estudos Retrospectivos , Valor Preditivo dos Testes , Hospitais com Alto Volume de Atendimentos , Medição de Risco , Biópsia Guiada por Imagem
3.
World J Urol ; 41(1): 101-107, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36269368

RESUMO

INTRODUCTION: Urothelial bladder cancer (UBC) with clinical suspicion of locally advanced growth or pelvic lymphogenic spread has a high risk of progression and death. PATIENTS AND METHODS: Bladder cancer patients with locally advanced (cT3/4) tumor growth or suspected pelvic lymphogenic spread (cN+) were treated with preoperative cisplatin-containing chemotherapy and consolidative cystectomy with pelvic lymphadenectomy. We aimed to identify prognostic factors and describe the patients' oncological outcome. RESULTS: A complete dataset including follow-up data was available for 96 patients. In a univariate analysis, we identified cN stage (cN+ vs cN-, HR 2.7, 95% CI 1.3-6.0), response to chemotherapy (HR 0.2, 95% CI 0.1-0.5), ypT stage (ypT0/is/1 vs ypT2-4, HR 3.1, 95% CI 1.4-6.8), ypN stage (ypN + vs ypN-, HR 7.9, 95% CI 3.7-17.0), resection status (HR 4.4, 95% CI HR 1.5-13.0) as significantly associated with cancer-specific survival. In a multivariate regression analysis, both cN and ypN statuses were validated as independent prognostic factors for cancer-specific survival (cN: HR 2.6, 95% CI 1.1-6.1; ypN: HR 5.5, 95% CI 2.0-15.1). DISCUSSION: Lymph node status was identified as a prognostic marker in a high-risk cohort of UBC patients treated with inductive chemotherapy and cystectomy. Establishing cN status as a prognosticator underlines the necessity to aggressively treat these patients despite reported impreciseness of imaging procedures in UCB. Patients with histologically positive lymph nodes following preoperative chemotherapy have a very poor prognosis, and thus, the need for adjuvant systemic treatment is emphasized. CONCLUSION: Both clinically and pathologically affected lymph nodes convey a poor prognosis in bladder cancer and necessitate aggressive treatment.


Assuntos
Carcinoma de Células de Transição , Neoplasias da Bexiga Urinária , Humanos , Cistectomia/métodos , Terapia Neoadjuvante , Resultado do Tratamento , Metástase Linfática/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/tratamento farmacológico , Carcinoma de Células de Transição/diagnóstico por imagem , Carcinoma de Células de Transição/cirurgia , Linfonodos/patologia , Excisão de Linfonodo , Estadiamento de Neoplasias
4.
World J Urol ; 41(3): 679-685, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35986781

RESUMO

PURPOSE: Renal cysts comprise benign and malignant entities. Risk assessment profits from CT/MRI imaging using the Bosniak classification. While Bosniak-IIF, -III, and -IV cover complex cyst variants, Bosniak-IIF and -III stand out due to notorious overestimation. Contrast-enhanced ultrasound (CEUS) is promising to overcome this deficit but warrants standardization. This study addresses the benefits of a combined CEUS and CT/MRI evaluation of renal cysts. The study provides a realistic account of kidney tumor boards' intricacies in trying to validate renal cysts. METHODS: 247 patients were examined over 8 years. CEUS lesions were graded according to CEUS-Bosniak (IIF, III, IV). 55 lesions were resected, CEUS-Bosniak- and CT/MRI-Bosniak-classification were correlated with histopathological diagnosis. Interobserver agreement between the classifications was evaluated statistically. 105 lesions were followed by ultrasound, and change in CEUS-Bosniak-types and lesion size were documented. RESULTS: 146 patients (156 lesions) were included. CEUS classified 67 lesions as CEUS-Bosniak-IIF, 44 as CEUS-Bosniak-III, and 45 as CEUS-Bosniak-IV. Histopathology of 55 resected lesions revealed benign cysts in all CEUS-Bosniak-IIF lesions (2/2), 40% of CEUS-Bosniak-III and 8% of CEUS-Bosniak-IV, whereas malignancy was uncovered in 60% of CEUS-Bosniak-III and 92% of CEUS-Bosniak-IV. Overall, CEUS-Bosniak-types matched CT/MRI-Bosniak types in 58% (fair agreement, κ = 0.28). CEUS-Bosniak resulted in higher stages than CT/MRI-Bosniak (40%). Ultrasound follow-up of 105 lesions detected no relevant differences between CEUS-Bosniak-types concerning cysts size. 99% of lesions showed the same CEUS-Bosniak-type. CONCLUSION: The CEUS-Bosniak classification is an essential tool in clinical practice to differentiate and monitor renal cystic lesions and empowers diagnostic work-up and patient care.


Assuntos
Cistos , Doenças Renais Císticas , Neoplasias Renais , Humanos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Rim/diagnóstico por imagem , Rim/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Doenças Renais Císticas/diagnóstico por imagem , Doenças Renais Císticas/patologia , Cistos/patologia
5.
Eur Radiol ; 33(8): 5549-5556, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36806571

RESUMO

OBJECTIVES: To compare the visibility of anatomical structures and overall quality of the attenuation images obtained with a dark-field X-ray radiography prototype with those from a commercial radiography system. METHODS: Each of the 65 patients recruited for this study obtained a thorax radiograph at the prototype and a reference radiograph at the commercial system. Five radiologists independently assessed the visibility of anatomical structures, the level of motion artifacts, and the overall image quality of all attenuation images on a five-point scale, with 5 points being the highest rating. The average scores were compared between the two image types. The differences were evaluated using an area under the curve (AUC) based z-test with a significance level of p ≤ 0.05. To assess the variability among the images, the distributions of the average scores per image were compared between the systems. RESULTS: The overall image quality was rated high for both devices, 4.2 for the prototype and 4.6 for the commercial system. The rating scores varied only slightly between both image types, especially for structures relevant to lung assessment, where the images from the commercial system were graded slightly higher. The differences were statistically significant for all criteria except for the bronchial structures, the cardiophrenic recess, and the carina. CONCLUSIONS: The attenuation images acquired with the prototype were assigned a high diagnostic quality despite a lower resolution and the presence of motion artifacts. Thus, the attenuation-based radiographs from the prototype can be used for diagnosis, eliminating the need for an additional conventional radiograph. KEY POINTS: • Despite a low tube voltage (70 kVp) and comparably long acquisition time, the attenuation images from the dark-field chest radiography system achieved diagnostic quality for lung assessment. • Commercial chest radiographs obtained a mean rating score regarding their diagnostic quality of 4.6 out of 5, and the grating-based images had a slightly lower mean rating score of 4.2 out of 5. • The difference in rating scores for anatomical structures relevant to lung assessment is below 5%.


Assuntos
Radiografia Torácica , Tórax , Humanos , Raios X , Radiografia Torácica/métodos , Radiografia , Pulmão/diagnóstico por imagem
6.
J Med Internet Res ; 25: e50865, 2023 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-38133918

RESUMO

Exploring the generative capabilities of the multimodal GPT-4, our study uncovered significant differences between radiological assessments and automatic evaluation metrics for chest x-ray impression generation and revealed radiological bias.


Assuntos
Radiologia , Humanos , Raios X , Radiografia , Benchmarking , Percepção
7.
Radiology ; 303(1): 119-127, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35014904

RESUMO

Background Dark-field chest radiography allows for assessment of lung alveolar structure by exploiting wave optical properties of x-rays. Purpose To evaluate the qualitative and quantitative features of dark-field chest radiography in participants with pulmonary emphysema as compared with those in healthy control subjects. Materials and Methods In this prospective study conducted from October 2018 to October 2020, participants aged at least 18 years who underwent clinically indicated chest CT were screened for participation. Inclusion criteria were an ability to consent to the procedure and stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and any lung condition besides emphysema that was visible on CT images. Participants were examined with a clinical dark-field chest radiography prototype that simultaneously acquired both attenuation-based radiographs and dark-field chest radiographs. Dark-field coefficients were tested for correlation with each participant's CT-based emphysema index using the Spearman correlation test. Dark-field coefficients of adjacent groups in the semiquantitative Fleischner Society emphysema grading system were compared using a Wilcoxon Mann-Whitney U test. The capability of the dark-field coefficient to enable detection of emphysema was evaluated with receiver operating characteristics curve analysis. Results A total of 83 participants (mean age, 65 years ± 12 [standard deviation]; 52 men) were studied. When compared with images from healthy participants, dark-field chest radiographs in participants with emphysema had a lower and inhomogeneous dark-field signal intensity. The locations of focal signal intensity loss on dark-field images corresponded well with emphysematous areas found on CT images. The dark-field coefficient was negatively correlated with the quantitative CT-based emphysema index (r = -0.54, P < .001). Participants with Fleischner Society grades of mild, moderate, confluent, or advanced destructive emphysema exhibited a lower dark-field coefficient than those without emphysema (eg, 1.3 m-1 ± 0.6 for participants with confluent or advanced destructive emphysema vs 2.6 m-1 ± 0.4 for participants without emphysema; P < .001). The area under the receiver operating characteristic curve for detection of mild emphysema was 0.79. Conclusion Pulmonary emphysema leads to reduced signal intensity on dark-field chest radiographs, showing the technique has potential as a diagnostic tool in the assessment of lung diseases. © RSNA, 2022 See also the editorial by Hatabu and Madore in this issue.


Assuntos
Enfisema , Enfisema Pulmonar , Adolescente , Adulto , Idoso , Enfisema/diagnóstico por imagem , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Estudos Prospectivos , Enfisema Pulmonar/diagnóstico por imagem , Radiografia , Radiografia Torácica/métodos
9.
J Digit Imaging ; 35(6): 1738-1747, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35879495

RESUMO

Hepatic steatosis is a common condition and an early manifestation of a systemic metabolic syndrome. As of today, there is no broadly accepted method for the diagnosis of hepatic steatosis in contrast-enhanced CT images. This retrospective study evaluates the potential of quantitative iodine values in portal venous phase iodine images in dual-energy CT (DECT) by measuring iodine concentrations in regions of interest (ROI) and analyzing the absolute iodine concentration of the liver parenchyma as well as three different blood-normalized iodine concentrations in a study cohort of 251 patients. An independent two sample t-test (p < 0.05) was used to compare the iodine concentrations of healthy and fatty liver. Diagnostic performance was assessed by ROC (receiver operating characteristic) curve analysis. The results showed significant differences between the average iodine concentration of healthy and fatty liver parenchyma for the absolute and for the blood-normalized iodine concentrations. The study concludes that the iodine uptake of the liver parenchyma is impaired by hepatic steatosis, and that the measurement of iodine concentration can provide a suitable method for the detection of hepatic steatosis in quantitative iodine images. Suitable thresholds of quantitative iodine concentration values for the diagnosis of hepatic steatosis are provided.


Assuntos
Fígado Gorduroso , Iodo , Humanos , Meios de Contraste , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Fígado Gorduroso/diagnóstico por imagem
10.
Radiology ; 301(2): 389-395, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34427464

RESUMO

Background X-ray dark-field radiography takes advantage of the wave properties of x-rays, with a relatively high signal in the lungs due to the many air-tissue interfaces in the alveoli. Purpose To describe the qualitative and quantitative characteristics of x-ray dark-field images in healthy human subjects. Materials and Methods Between October 2018 and January 2020, patients of legal age who underwent chest CT as part of their diagnostic work-up were screened for study participation. Inclusion criteria were a normal chest CT scan, the ability to consent, and the ability to stand upright without help. Exclusion criteria were pregnancy, serious medical conditions, and changes in the lung tissue, such as those due to cancer, pleural effusion, atelectasis, emphysema, infiltrates, ground-glass opacities, or pneumothorax. Images of study participants were obtained by using a clinical x-ray dark-field prototype, recently constructed and commissioned at the authors' institution, to simultaneously acquire both attenuation-based and dark-field thorax radiographs. Each subject's total dark-field signal was correlated with his or her lung volume, and the dark-field coefficient was correlated with age, sex, weight, and height. Results Overall, 40 subjects were included in this study (average age, 62 years ± 13 [standard deviation]; 26 men, 14 women). Normal human lungs have high signal, while the surrounding osseous structures and soft tissue have very low and no signal, respectively. The average dark-field signal was 2.5 m-1 ± 0.4 of examined lung tissue. There was a correlation between the total dark-field signal and the lung volume (r = 0.61, P < .001). No difference was found between men and women (P = .78). Also, age (r = -0.18, P = .26), weight (r = 0.24, P = .13), and height (r = 0.01, P = .96) did not influence dark-field signal. Conclusion This study introduces qualitative and quantitative values for x-ray dark-field imaging in healthy human subjects. The quantitative x-ray dark-field coefficient is independent from demographic subject parameters, emphasizing its potential in diagnostic assessment of the lung. ©RSNA, 2021 See also the editorial by Hatabu and Madore in this issue.


Assuntos
Pulmão/anatomia & histologia , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Estudos de Avaliação como Assunto , Feminino , Humanos , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pesquisa Qualitativa , Valores de Referência
11.
Eur Radiol ; 31(2): 1002-1010, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32856165

RESUMO

OBJECTIVES: To assess the clinical utility of dual-energy CT (DE-CT)-derived iodine concentration (IC) and effective Z (Zeff) in addition to conventional CT attenuation (HU) for the discrimination between primary lung cancer (LC) and pulmonary metastases (PM) from different primary malignancies. METHODS: DE-CT scans of 79 patients with LC (3 histopathologic subgroups) and 89 patients with PM (5 histopathologic subgroups) were evaluated. Quantitative IC, Zeff, and conventional HU values were extracted and normalized to the thoracic aorta. Differences between groups were assessed by pairwise Welch's t test. Correlation and linear regression analyses were used to examine the relationship of imaging parameters in LC and PM. Diagnostic accuracy was measured by the area under receiver operator characteristic curve (AUC) and validated based on resampling methods. RESULTS: Significant differences between subgroups of LC and PMs were noted for all imaging parameters, with the highest number of significant pairs for IC. In univariate analysis, only IC was a significant diagnostic feature for discriminating LC from PM (p = 0.03). All quantitative imaging parameters correlated significantly (p < 0.0001, respectively), with the highest correlation between IC and Zeff (r = 0.91), followed by IC and HU (r = 0.76) and Zeff and HU (r = 0.73). Diagnostic models combining IC or Zeff with HU (IC+HU: AUC = 0.73; Zeff+HU: AUC = 0.69; IC+Zeff+HU: AUC = 0.73) were not significantly different and outperformed individual parameters (IC: AUC = 0.57; Zeff: AUC = 0.57; HU: AUC = 0.55) in diagnostic accuracy (p < 0.05, respectively). CONCLUSION: DE-CT-derived IC or Zeff and conventional HU represent complementary imaging parameters, which, if used in combination, may improve the differentiation between LC and PM. KEY POINTS: • Individual quantitative imaging parameters derived from DE-CT (iodine concentration, effective Z) and conventional CT (HU) provide complementary diagnostic information for the differentiation of primary lung cancer and pulmonary metastases. • A combination of conventional HU and DE-CT parameters enhances the diagnostic utility of individual parameters.


Assuntos
Neoplasias Pulmonares , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Biomarcadores , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
12.
Eur Radiol ; 31(6): 4175-4183, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33211140

RESUMO

OBJECTIVE: Assessing the advantage of x-ray dark-field contrast over x-ray transmission contrast in radiography for the detection of developing radiation-induced lung damage in mice. METHODS: Two groups of female C57BL/6 mice (irradiated and control) were imaged obtaining both contrasts monthly for 28 weeks post irradiation. Six mice received 20 Gy of irradiation to the entire right lung sparing the left lung. The control group of six mice was not irradiated. A total of 88 radiographs of both contrasts were evaluated for both groups based on average values for two regions of interest, covering (irradiated) right lung and healthy left lung. The ratio of these average values, R, was distinguished between healthy and damaged lungs for both contrasts. The time-point when deviations of R from healthy lung exceeded 3σ was determined and compared among contrasts. The Wilcoxon-Mann-Whitney test was used to test against the null hypothesis that there is no difference between both groups. A selection of 32 radiographs was assessed by radiologists. Sensitivity and specificity were determined in order to compare the diagnostic potential of both contrasts. Inter-reader and intra-reader accuracy were rated with Cohen's kappa. RESULTS: Radiation-induced morphological changes of lung tissue caused deviations from the control group that were measured on average 10 weeks earlier with x-ray dark-field contrast than with x-ray transmission contrast. Sensitivity, specificity, and accuracy doubled using dark-field radiography. CONCLUSION: X-ray dark-field radiography detects morphological changes of lung tissue associated with radiation-induced damage earlier than transmission radiography in a pre-clinical mouse model. KEY POINTS: • Significant deviations from healthy lung due to irradiation were measured after 16 weeks with x-ray dark-field radiography (p = 0.004). • Significant deviations occur on average 10 weeks earlier for x-ray dark-field radiography in comparison to x-ray transmission radiography. • Sensitivity and specificity doubled when using x-ray dark-field radiography instead of x-ray transmission radiography.


Assuntos
Pulmão , Animais , Feminino , Pulmão/diagnóstico por imagem , Camundongos , Camundongos Endogâmicos C57BL , Radiografia , Sensibilidade e Especificidade , Raios X
13.
BMC Cancer ; 20(1): 8, 2020 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-31900121

RESUMO

BACKGROUND: Patients with locally advanced bladder cancer (cT3/4 cN0/N+ cM0) have a poor prognosis despite radical surgical therapy and perioperative chemotherapy. Preliminary data suggest that the combination of radiation and immunotherapy does not lead to excess toxicity and may have synergistic (abscopal) anti-tumor effects. We hypothesize that the combined preoperative application of the PD-1 checkpoint-inhibitor Nivolumab with concomitant radiation therapy of the bladder and pelvic region followed by radical cystectomy with standardized lymphadenectomy is safe and feasible and might improve outcome for patients with locally advanced bladder cancer. METHODS: Study design: "RACE IT" (AUO AB 65/18) is an investigator initiated, prospective, multicenter, open, single arm phase II trial sponsored by Technical University Munich. Study drug and funding are provided by the company Bristol-Myers Squibb. Study treatment: Patients will receive Nivolumab 240 mg i.v. every 2 weeks for 4 cycles preoperatively with concomitant radiation therapy of bladder and pelvic region (max. 50.4 Gy). Radical cystectomy with standardized bilateral pelvic lymphadenectomy will be performed between week 11-15. Primary endpoint: Rate of patients with completed treatment consisting of radio-immunotherapy and radical cystectomy at the end of week 15. Secondary endpoints: Acute and late toxicity, therapy response and survival (1 year follow up). Main inclusion criteria: Patients with histologically confirmed, locally advanced bladder cancer (cT3/4, cN0/N+), who are ineligible for neoadjuvant, cisplatin-based chemotherapy or who refuse neoadjuvant chemotherapy. Main exclusion criteria: Patients with metastatic disease (lymph node metastasis outside pelvis or distant metastasis) or previous chemo-, immune- or radiation therapy. Planned sample size: 33 patients, interim analysis after 11 patients. DISCUSSION: This trial aims to evaluate the safety and feasibility of the combined approach of preoperative PD-1 checkpoint-inhibitor therapy with concomitant radiation of bladder and pelvic region followed by radical cystectomy. The secondary objectives of therapy response and survival are thought to provide preliminary data for further clinical evaluation after successful completion of this trial. Recruitment has started in February 2019. TRIAL REGISTRATION: Protocol Code RACE IT: AB 65/18; EudraCT: 2018-001823-38; Clinicaltrials.gov: NCT03529890; Date of registration: 27 June 2018.


Assuntos
Radioterapia Adjuvante , Neoplasias da Bexiga Urinária/diagnóstico , Neoplasias da Bexiga Urinária/terapia , Antineoplásicos Imunológicos/farmacologia , Antineoplásicos Imunológicos/uso terapêutico , Quimioterapia Adjuvante , Terapia Combinada , Cistectomia , Feminino , Humanos , Imunoterapia , Masculino , Metástase Neoplásica , Estadiamento de Neoplasias , Radioterapia Adjuvante/efeitos adversos , Radioterapia Adjuvante/métodos , Resultado do Tratamento
14.
Acta Radiol ; 61(11): 1505-1511, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32064891

RESUMO

BACKGROUND: Lymph nodes (LN) are examined in every computed tomography (CT) scan. Until now, an evaluation is only possible based on morphological criteria. With dual-energy CT (DECT) systems, iodine concentration (IC) can be measured which could conduct in an improved diagnostic evaluation of LNs. PURPOSE: To define standard values for IC of cervical, axillary, and inguinal LNs in DECT. MATERIAL AND METHODS: Imaging data of 297 patients who received a DECT scan of the neck, thorax, abdomen-pelvis, or a combination of those in a portal-venous phase were retrospectively collected from the institutional PACS. No present history of malignancy, inflammation, or trauma in the examined region was present. For each examined region, the data of 99 patients were used. The IC of the three largest LNs, the main artery, the main vein, and a local muscle of the examined area was measured, respectively. RESULTS: Normalization of the IC of LNs to the artery, vein, muscle, or a combination of those did not lead to a decreased value-range. The smallest range and confidence interval (CI) of IC was found when using absolute values of IC for each region. Hereby, mean values (95% CI) for IC of LN were found: 2.09 mg/mL (2.00-2.18 mg/mL) for neck, 1.24 mg/mL (1.16-1.33 mg/mL) for axilla, and 1.11 mg/mL (1.04-1.17 mg/mL) for groin. CONCLUSION: The present study suggests standard values for IC of LNs in dual-layer CT could be used to differentiate between healthy and pathological lymph nodes, considering the used contrast injection protocol.


Assuntos
Meios de Contraste/farmacocinética , Iodo/farmacocinética , Linfonodos/metabolismo , Intensificação de Imagem Radiográfica/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Axila , Estudos de Coortes , Feminino , Virilha , Humanos , Linfonodos/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Pescoço , Estudos Retrospectivos
16.
Knee Surg Sports Traumatol Arthrosc ; 28(3): 897-904, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31127313

RESUMO

PURPOSE: Several anatomic risk factors associated with patellofemoral disorders have been described. The purpose of this study was to analyze the relationship between bony parameters commonly used to analyze and define patellofemoral malalignment. METHODS: Patients with patellofemoral disorders presenting between 2016 and 2018 who underwent a standardized radiographic workup including conventional radiographs, weight bearing full-leg radiographs, magnetic resonance imaging (MRI) of the knee, and torsional analysis using hip-knee-ankle MRI were initially included. Patients with a history of lower extremity fracture and a history of surgical procedures affecting bony alignment or partial/total arthroplasty were subsequently excluded. Radiographs and MRI of all included patients were analyzed by four independent observers. Parameters of interest were: femoral torsion, tibial torsion, trochlear dysplasia, tibial tuberosity-trochlear groove (TT-TG) distance, and frontal mechanical axis. All parameters were compared between patients with low grade and high grade trochlear dysplasia as well as between female and male patients. Correlation of continuous variables was assessed with the Pearson correlation coefficient. A binary logistic regression model was used for the calculation of odds ratio between different parameters. Interclass correlation coefficients (ICC) were calculated to determine the interobserver reproducibility. RESULTS: A total of 151 patients could be included for detailed analysis. Group comparison revealed that patients with high grade trochlear dysplasia showed significantly higher values for femoral torsion (low grade: 9.8° ± 11.0°, high grade: 16.8° ± 11.5°; p < 0.001) and significantly higher values for TT-TG distance (low grade: 19.0 mm ± 5.0 mm, high grade: 21.9 mm ± 5.4 mm; p = 0.002). No significant difference was found for age, tibial torsion, and frontal mechanical axis. With regard to gender, female patients had higher values for femoral torsion (female: 15.6° ± 11.3°, male: 11.0° ± 12.7°; p = 0.044). The correlation analysis found significant correlation between femoral torsion and tibial torsion (r = 0.244, p = 0.003), femoral torsion and TT-TG distance (r = 0.328, p < 0.001), femoral torsion and frontal mechanical axis (r = 0.291, p < 0.001), and tibial torsion and TT-TG distance (r = 0.182, p = 0.026). CONCLUSION: Bony malalignment in patients with patellofemoral disorder is a complex problem given the significant correlation between femoral and tibial torsion, trochlear dysplasia, TT-TG distance, and frontal mechanical axis. Advanced imaging to analyze rotational and frontal plane alignment is recommended in patients with trochlear dysplasia and/or increased TT-TG on standard radiographs and knee MRI. Understanding of the bony pathology in patellofemoral disorders is key to improve the therapeutic and surgical decision. LEVEL OF EVIDENCE: III, retrospective cohort study.


Assuntos
Mau Alinhamento Ósseo/fisiopatologia , Articulação Patelofemoral/fisiopatologia , Adolescente , Adulto , Mau Alinhamento Ósseo/diagnóstico por imagem , Feminino , Fêmur/diagnóstico por imagem , Fêmur/fisiopatologia , Fêmur/cirurgia , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Articulação Patelofemoral/diagnóstico por imagem , Articulação Patelofemoral/cirurgia , Radiografia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Rotação , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Tíbia/cirurgia
17.
Int J Cancer ; 145(8): 2292-2303, 2019 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-30882891

RESUMO

This prospective trial aimed to investigate whether tumor-specific cKIT and PDGFRA mutations can be detected and quantified in circulating tumor (ct)DNA in patients with active GIST, and whether detection indicates disease activity. We included 25 patients with active disease and cKIT or PDGFRA mutations detected in tissue. Mutant ctDNA was detected in the peripheral blood plasma using allele-specific ligation (L-)PCR and droplet digital (d)PCR. CtDNA harboring tumor-specific cKIT or PDGFRA mutations was detected at least once in 16 out of 25 patients using L-PCR (64%) and in 20 out of 25 patients with dPCR (80%). Using dPCR, the absolute numbers of ctDNA fragments (DNA copies/ml) and the mutant allele frequency (MAF; in percent of wild-type control) strongly correlated with tumor size expressed as RECIST1.1 sum of diameter (SOD) in mm (ρ = 0.3719 and 0.408, respectively, p < 0.0001) and response status (ρ = 0.3939 and 0.392, respectively, p < 0.0001 and p < 0.001). Specificity of dPCR for detection of progression was 79.2% with a sensitivity of 55.2% and dPCR discriminated CR from active disease with a specificity of 96% and s sensitivity of 44.7%. With L-PCR, correlations of MAF with tumor size and response status were less prominent. Serial ctDNA measurement reflected individual disease courses over time. Targeted panel sequencing of four patients detected additional driver mutations in all cases and secondary resistance mutations in two cases. Thus, ctDNA indicates disease activity in patients with GIST and should be incorporated as companion biomarker in future prospective trials.


Assuntos
DNA Tumoral Circulante/genética , DNA de Neoplasias/genética , Tumores do Estroma Gastrointestinal/genética , Mutação , Proteínas Proto-Oncogênicas c-kit/genética , Receptor alfa de Fator de Crescimento Derivado de Plaquetas/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/genética , DNA Tumoral Circulante/sangue , DNA de Neoplasias/sangue , Feminino , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde/métodos , Reação em Cadeia da Polimerase/métodos , Estudos Prospectivos , Inibidores de Proteínas Quinases/uso terapêutico
18.
Eur Radiol ; 29(11): 5950-5960, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31073861

RESUMO

OBJECTIVES: Evaluation of sparse sampling computed tomography (SpSCT) regarding subjective and objective image criteria for the detection of pulmonary embolism (PE) at different simulated dose levels. METHODS: Computed tomography pulmonary angiography (CTPA) scans of 20 clinical patients were used to obtain simulated low-dose scans with 100%-50%-25%-12.5%-6.3%-3.1% of the clinical dose, resulting in a total of six dose levels (DL). From these full sampling (FS) data, every second (2-SpSCT) or fourth (4-SpSCT) projection was used to obtain simulated sparse sampling scans. Each image set was evaluated by four blinded radiologists regarding subjective image criteria (artifacts, image quality) and diagnostic performance (confidence, sensitivity, specificity, accuracy, and area under the curve). Additionally, the contrast-to-noise ratio (CNR) was evaluated for objective image quality. RESULTS: Sensitivity was 100% with 2-SpSCT and 4-SpSCT at the 25% DL and the 12.5% DL for all localizations of PE (one subgroup 98.5%). With FS, the sensitivity decreased to 90% at the 12.5% DL. 2-SpSCT and 4-SpSCT showed higher values for sensitivity, specificity, accuracy, and the area under the curve at all DL compared with FS. Subjective image quality was significantly higher for 4-SpSCT compared with FS at each dose level (p < 0.01, paired t test). Only with 4-SpSCT, all examinations were rated as showing diagnostic image quality at the 12.5% DL. CONCLUSIONS: Via SpSCT, a dose reduction down to a 12.5% dose level (corresponding to a mean effective dose of 0.38 mSv in the current study) for CTPA is possible while maintaining high image quality and full diagnostic confidence. KEY POINTS: • With sparse sampling CT, radiation dose could be significantly reduced in clinical routine. • Sparse sampling CT is a novel hardware solution with which less projection images are acquired. • In the current study, a dose reduction of 87.5% (corresponding to a mean effective dose of 0.38 mSv) for CTPA could be achieved while maintaining excellent diagnostic performance.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Embolia Pulmonar/diagnóstico por imagem , Análise de Variância , Artefatos , Estudos de Viabilidade , Humanos , Pulmão/diagnóstico por imagem , Segurança do Paciente , Doses de Radiação , Sensibilidade e Especificidade
19.
BMC Med Imaging ; 19(1): 57, 2019 07 24.
Artigo em Inglês | MEDLINE | ID: mdl-31340756

RESUMO

BACKGROUND: In this study we sought to retrospectively evaluate whether a very brief cardiac magnetic resonance imaging (CMR) protocol sufficiently distinguishes patients with relevant myocardial changes with need for further examination from healthy subjects. METHODS: Patients with clinical indication for CMR (n = 160) were included in the study. Patients were categorized into two groups depending on presence of left ventricular (LV) dysfunction. ROC-analysis was done for results of T1-, T2- mapping and extracellular volume evaluation in patients without LV dysfunction. Binary endpoint was correctly depicted pathology of the conventional qualitative CMR techniques and report. RESULTS: In the patient cohort without LV dysfunction (49%), AUC for T1 mapping was 82% (p < 0.001), 60% for T2 mapping (p = 0.1) and 79% for ECV (p < 0.001). T1 mapping was significantly superior to T2 mapping to rule out left ventricular pathology (p = 0.012). Sensitivity for the combined use of T1 mapping and sBTFE cine imaging was 98%; the negative predictive value was 90%. In 49 patients (30%) full protocol CMR did not provide any additional information; T1 mapping correctly detected 57% of the subjects from this group who would not benefit from additional CMR. CONCLUSION: A shortened CMR protocol comprising T1 mapping and LV-function analysis seems suitable to rule out myocardial alterations. Every third patient of the study population did not benefit from full contrast enhanced CMR. The shortened protocol correctly identified every fifth patient who would not benefit but no relevant pathologic findings with the obligation for treatment were missed.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Disfunção Ventricular Esquerda/patologia , Função Ventricular Esquerda
20.
Acta Radiol ; 60(4): 478-487, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29933714

RESUMO

BACKGROUND: Computed tomography pulmonary angiography (CTPA) is the standard imaging modality for detection or rule out of pulmonary embolism (PE); however, radiation exposure is a serious concern. With iterative reconstruction algorithms a distinct dose reduction could be achievable. PURPOSE: To evaluate a next generation iterative reconstruction algorithm for detection or rule-out of PE in simulated low-dose CTPA. MATERIAL AND METHODS: Low-dose CT datasets with 50%, 25%, and 12.5% of the original tube current were simulated based on CTPA examinations of 92 patients with suspected PE. All datasets were reconstructed with two reconstruction algorithms: standard filtered back-projection (FBP) and iterative model reconstruction (IMR). In total, 736 CTPA datasets were evaluated by three blinded radiologists regarding image quality, diagnostic confidence, and detectability of PE. Furthermore, contrast-to-noise ratio (CNR) was calculated. RESULTS: Images reconstructed with IMR showed better detectability of PE than images reconstructed with FBP, especially at lower dose levels. With IMR, sensitivity was over 95% for central and segmental PE down to a dose level of 25%. Significantly higher subjective image quality was shown at lower dose levels (25% and 12.5%) for IMR images whereas it was higher for FBP images at higher dose levels. FBP was rated as showing less artificial image appearance. CNR was significantly higher with IMR at all dose levels. CONCLUSION: By using IMR, a dose reduction of up to 50% while maintaining satisfactory image quality seems feasible in standard clinical situations, resulting in a mean effective dose of 1.38 mSv for CTPA.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa