Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Glob Cardiol Sci Pract ; 2021(3): e202121, 2021 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-34805379

RESUMO

Background: There is a pressing need to improve early and long-term results of the Mustard operation. A modification of the operation was introduced at the Aswan Heart Centre for this purpose which relies on creating new functional atria rather than the two rigid channels in the classical Mustard operation. Objectives: To evaluate the morphology and function of the neo-atria, shortly after modified mustard operation for a 'neglected' patient with TGA, VSD and severe pulmonary hypertension. Methods: A 6-year-old with neglected TGA, VSD and pulmonary hypertension presented with severe cyanosis, clubbing and haemoconcentration (Hb 22 g/dL), underwent the modified Aswan-Mustard operation (MAM) with rapid smooth postoperative recovery. Repeated 2D echograms and multi-slice CT scans, followed by 3D segmentation, were performed after the operation. The size, shape, and morphology of the neo-atria were measured and measurements of the patterns of instantaneous filling and emptying of the right and left ventricles were quantified. Results: The neo-systemic venous atrium consisted of three components with a combined volume of 78 mL/m2, all of which contributed to the reservoir, conduit, and importantly contractile function of the neo-atrium. The pulmonary venous atrium consisted of two components with a combined volume of 66 mL/m2. These measurements were made at atrial end diastole. The volumes of the systemic venous and the pulmonary venous diminished to 51 and 54 mL/m2, respectively, at the end atrial systole - indicating relatively preserved contractile functions. Conclusion: Following the modified Aswan-Mustard operation, neo-atrial function was relatively well preserved compared to the classical operation. The long-term results of these findings and their effects on quality of life need to be studied further.

2.
Glob Cardiol Sci Pract ; 2019(2): e201918, 2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31799292

RESUMO

Background. Truncus arteriosus (TA) caries a very poor prognosis. In the absence of early correction, only 12 percent of patients born with this anomaly survive beyond one year. There is no agreement about the best method of surgical correction of this anomaly. We have devised an innovative valveless technique using autologous arterial tissue to repair TA. Objectives. Characterizing the size, shape and pattern of flow in the neo-aorta and pulmonary artery, in a patient following the new technique. Patient and Methods. Cardiac MRI and multislice CT imaging, followed by offline computerized image analysis was used in a patient aged 3 months, within 3 weeks of operating. Results. The size, shape and topology of the neo-aorta and pulmonary artery, approximated that present in normal hearts. The pattern of flow in the reconstructed vessels was laminar, throughout the cardiac cycle with minor acceleration during systole. The pulmonary regurgitation resulting from the absence of a valve occurred during late diastole, and was well tolerated. The size of the right ventricle diminished considerably following operation, and the right ventricular ejection fraction was supernormal. Conclusion. This early study in one patient provides new unique data of the size, shape, topology and pattern of flow in the neo-aorta and pulmonary artery, which appear to approximate normality. The long-term results of this promising operation need to be studied.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa