Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Respir Med Case Rep ; 43: 101838, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37021142

RESUMO

Background: The clinical and molecular characteristics of three patients with previously unreported SERPINA1 mutations associated with severe alpha-1 antitrypsin deficiency (AATD) are described. The pathophysiology of the chronic obstructive pulmonary disease (COPD) present in these patients was characterized through clinical, biochemical, and genetic examinations. Case presentations: Case 1: A 73-year-old male with bilateral centri-to panlobular emphysema and multiple increasing ventrobasal bullae and incomplete fissures, COPD (Global Initiative for Chronic Obstructive Lung Disease (GOLD) grade III B), progressive dyspnea on exertion (DOE), AAT level of 0.1-0.2 g/L. Genetic testing revealed a unique SERPINA1 mutation: Pi*Z/c.1072C > T. This allele was designated PiQ0Heidelberg II. Case 2: A 47-year-old male with severely heterogenous centri-to panlobular emphysema concentrated in the lower lobes, COPD GOLD IV D with progressive DOE, AAT <0.1 g/L. He also had a unique Pi*Z/c.10del mutation in SERPINA1. This allele was named PiQ0Heidelberg III. Case 3: A 58-year-old female with basally accentuated panlobular emphysema, GOLD II B COPD, progressive DOE. AAT 0.1 g/L. Genetic analysis revealed Pi*Z/c.-5+1G > A and c.-472G > A mutations in SERPINA1. This variant allele was named PiQ0Heidelberg IV. Conclusions: Each of these patients had a unique and previously unreported SERPINA1 mutation. In two cases, AATD and a history of smoking led to severe lung disease. In the third case, timely diagnosis, and institution of AAT replacement stabilized lung function. Wider screening of COPD patients for AATD could lead to faster diagnosis and earlier treatment of AATD patients with AATD which could slow or prevent progression of their disease.

2.
Rofo ; 190(6): 542-550, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29390229

RESUMO

INTRODUCTION: To prospectively evaluate the feasibility of single contrast bolus high-pitch CT pulmonary angiography (CTPA) subsequently followed by low-dose retrospectively ECG-gated cardiac CT (4D-cCT) in patients with suspected pulmonary embolism (PE) to accurately evaluate right ventricular (RV) function. MATERIALS AND METHODS: 62 patients (33 female, age 65.1 ±â€Š17.5 years) underwent high-pitch CTPA examination with 80cc of iodinated contrast material. 5 s after the end of the high-pitch CTPA study, a low-dose retrospectively ECG-gated cardiac CT examination was automatically started. The volume CT dose index (CTDI vol) and dose length product (DLP) were recorded in all patients and the effective dose was calculated. For the assessment of image quality, attenuation was measured as Hounsfield units (HUs) within various regions of interest (ROIs). These ROIs were used to calculate the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality was assessed using a five-point Likert scale. On 4D-cCT, the ejection fraction of both ventricles (RVEF, LVEF) as well as the ratio of RVEF and LVEF (RVEF/LVEF) was assessed. The statistical difference of all parameters between the PE and non-PE group was calculated. RESULTS: The mean effective radiation dose was 4.22 ± 2.05 mSv. Attenuation measurements on CTPA showed the highest attenuation values in the main pulmonary artery (442.01 ±â€Š187.64). On 4D-cCT attenuation values were highest in the descending aorta (560.59 ±â€Š208.81). The CNR and SNR values on CTPA were highest within the main pulmonary artery (CNR = 12.43 ±â€Š4.57; SNR = 15.14 ±â€Š4.90). On 4D-cCT images, the highest SNR and CNR could be measured in the descending aorta (CNR = 10.26 ±â€Š5.57; SNR = 10.86 ±â€Š5.17). The mean LVEF was 60.73 %±â€Š14.65 %, and the mean RVEF was 44.90 %±â€Š9.54 %. The mean RVEF/LVEF was 0.79 ±â€Š0.29. There was no significant difference between the PE and non-PE group for either of the parameters. CONCLUSION: The investigated combined CTPA and 4D-cCT protocol is feasible using a single contrast bolus and allows the evaluation of RV function in patients with suspected PE. Further studies have to evaluate the additional value of this protocol regarding risk stratification in patients with PE. KEY POINTS: · High-pitch CTPA is fast enough to leave sufficient contrast material within the heart that can be used for an additional low-dose functional cardiac CT examination.. · The tube current of the evaluated 4D-cCT is reduced over the entire cardiac cycle without any full dose peak.. · Low-dose cardiac CT subsequently performed after high-pitch CTPA allows for detailed analysis of RV function.. CITATION FORMAT: · Schäfer JC, Haubenreisser H, Meyer M et al. Feasibility of a Single Contrast Bolus High-Pitch Pulmonary CT Angiography Protocol Followed by Low-Dose Retrospectively ECG-Gated Cardiac CT in Patients with Suspected Pulmonary Embolism. Fortschr Röntgenstr 2018; 190: 542 - 550.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/administração & dosagem , Tomografia Computadorizada Quadridimensional/métodos , Iopamidol/análogos & derivados , Embolia Pulmonar/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Iopamidol/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa