1.
Eur Radiol ; 34(4): 2560-2573, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37707548

RESUMO

OBJECTIVES: Response assessment to neoadjuvant systemic treatment (NAST) to guide individualized treatment in breast cancer is a clinical research priority. We aimed to develop an intelligent algorithm using multi-modal pretreatment ultrasound and tomosynthesis radiomics features in addition to clinical variables to predict pathologic complete response (pCR) prior to the initiation of therapy. METHODS: We used retrospective data on patients who underwent ultrasound and tomosynthesis before starting NAST. We developed a support vector machine algorithm using pretreatment ultrasound and tomosynthesis radiomics features in addition to patient and tumor variables to predict pCR status (ypT0 and ypN0). Findings were compared to the histopathologic evaluation of the surgical specimen. The main outcome measures were area under the curve (AUC) and false-negative rate (FNR). RESULTS: We included 720 patients, 504 in the development set and 216 in the validation set. Median age was 51.6 years and 33.6% (242 of 720) achieved pCR. The addition of radiomics features significantly improved the performance of the algorithm (AUC 0.72 to 0.81; p = 0.007). The FNR of the multi-modal radiomics and clinical algorithm was 6.7% (10 of 150 with missed residual cancer). Surface/volume ratio at tomosynthesis and peritumoral entropy characteristics at ultrasound were the most relevant radiomics. Hormonal receptors and HER-2 status were the most important clinical predictors. CONCLUSION: A multi-modal machine learning algorithm with pretreatment clinical, ultrasound, and tomosynthesis radiomics features may aid in predicting residual cancer after NAST. Pending prospective validation, this may facilitate individually tailored NAST regimens. CLINICAL RELEVANCE STATEMENT: Multi-modal radiomics using pretreatment ultrasound and tomosynthesis showed significant improvement in assessing response to NAST compared to an algorithm using clinical variables only. Further prospective validation of our findings seems warranted to enable individualized predictions of NAST outcomes. KEY POINTS: • We proposed a multi-modal machine learning algorithm with pretreatment clinical, ultrasound, and tomosynthesis radiomics features to predict response to neoadjuvant breast cancer treatment. • Compared with the clinical algorithm, the AUC of this integrative algorithm is significantly higher. • Used prior to the initiative of therapy, our algorithm can identify patients who will experience pathologic complete response following neoadjuvant therapy with a high negative predictive value.


Assuntos
Neoplasias da Mama , Humanos , Pessoa de Meia-Idade , Feminino , Neoplasias da Mama/terapia , Neoplasias da Mama/tratamento farmacológico , Terapia Neoadjuvante , Estudos Retrospectivos , Neoplasia Residual , Radiômica
2.
J Ultrasound Med ; 43(1): 109-114, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772458

RESUMO

OBJECTIVES: Shear wave elastography (SWE) is increasingly used in breast cancer diagnostics. However, large, prospective, multicenter data evaluating the reliability of SWE is missing. We evaluated the intra- and interobserver reliability of SWE in patients with breast lesions categorized as BIRADS 3 or 4. METHODS: We used data of 1288 women at 12 institutions in 7 countries with breast lesions categorized as BIRADS 3 to 4 who underwent conventional B-mode ultrasound and SWE. 1243 (96.5%) women had three repetitive conventional B-mode ultrasounds as well as SWE measurements performed by a board-certified senior physician. 375 of 1288 (29.1%) women received an additional ultrasound examination with B-mode and SWE by a second physician. Intraclass correlation coefficients (ICC) were calculated to examine intra- and interobserver reliability. RESULTS: ICC for intraobserver reliability showed an excellent correlation with ICC >0.9, while interobserver reliability was moderate with ICC of 0.7. There were no clinically significant differences in intraobserver reliability when SWE was performed in lesions categorized as BI-RADS 3 or 4 as well as in histopathologically benign or malignant lesions. CONCLUSION: Reliability of additional SWE was evaluated on a study cohort consisting of 1288 breast lesions categorized as BI-RADS 3 and 4. SWE shows an excellent intraobserver reliability and a moderate interobserver reliability in the evaluation of solid breast masses.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Masculino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Ultrassonografia Mamária , Estudos Prospectivos , Reprodutibilidade dos Testes , Mama/diagnóstico por imagem , Mama/patologia , Sensibilidade e Especificidade , Diagnóstico Diferencial
3.
Breast Cancer Res Treat ; 201(1): 57-66, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37302085

RESUMO

PURPOSE: A previous study in our breast unit showed that the diagnostic accuracy of intraoperative specimen radiography and its potential to reduce second surgeries in a cohort of patients treated with neoadjuvant chemotherapy were low, which questions the routine use of Conventional specimen radiography (CSR) in this patient group. This is a follow-up study in a larger cohort to further evaluate these findings. METHODS: This retrospective study included 376 cases receiving breast-conserving surgery (BCS) after neoadjuvant chemotherapy (NACT) of primary breast cancer. CSR was performed to assess potential margin infiltration and recommend an intraoperative re-excision of any radiologically positive margin. The histological workup of the specimen served as gold standard for the evaluation of the accuracy of CSR and the potential reduction of second surgeries by CSR-guided re-excisions. RESULTS: 362 patients with 2172 margins were assessed. The prevalence of positive margins was 102/2172 (4.7%). CSR had a sensitivity of 37.3%, a specificity of 85.6%, a positive predictive value (PPV) of 11.3%, and a negative predictive value (NPV) of 96.5%. The rate of secondary procedures was reduced from 75 to 37 with a number needed to treat (NNT) of CSR-guided intraoperative re-excisions of 10. In the subgroup of patients with clinical complete response (cCR), the prevalence of positive margins was 38/1002 (3.8%), PPV was 6.5% and the NNT was 34. CONCLUSION: This study confirms our previous finding that the rate of secondary surgeries cannot be significantly reduced by CSR-guided intraoperative re-excisions in cases with cCR after NACT. The routine use CSR after NACT is questionable, and alternative tools of intraoperative margin assessment should be evaluated.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Humanos , Feminino , Terapia Neoadjuvante/métodos , Seguimentos , Estudos Retrospectivos , Carcinoma Ductal de Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Mastectomia Segmentar/métodos , Margens de Excisão , Radiografia
4.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
5.
Arch Gynecol Obstet ; 308(1): 219-229, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36604331

RESUMO

PURPOSE: Today, the decision to treat patients with chemotherapy for early breast cancer (EBC) is made based on the patient's individual risk stratification and tumor biology. In cases with chemotherapy indication, the neoadjuvant application (NACT) is the preferred option in comparison with primary surgery and adjuvant chemotherapy (ACT). Age remains a relevant factor in the decision-making process. The aim of the present study was to illustrate the impact of age on the use of systemic therapy in clinical routine. METHODS: The study separately analyzed chemotherapy use among six age cohorts of EBC patients who had been treated at 104 German breast units between January 2008 and December 2017. RESULTS: In total, 124,084 patients were included, 46,279 (37.3%) of whom had received chemotherapy. For 44,765 of these cases, detailed information on treatment was available. Within this cohort, chemotherapy was administered as NACT to 14,783 patients (33.0%) and as ACT to 29,982 (67.0%) patients. Due to the higher prevalence of unfavorable tumor subtypes, younger patients had a higher rate of chemotherapy (≤ 29y: 74.2%; 30-39y: 71.3%) and a higher proportion of NACT administration ( ≤ 29y: 66.9%; 30-39y: 56.0%) in comparison with elderly patients, who had lower rates for overall chemotherapy (60-69y: 37.5%; ≥ 70y: 17.6%) and NACT (60-69y: 25.5%; ≥ 70y: 22.8%). Pathologic complete response was higher in younger than in older patients (≤ 29y: 30.4% vs. ≥ 70y: 16.7%), especially for HER2- subtypes. CONCLUSION: The data from the nationwide German cohort reveal relevant age-dependent discrepancies concerning the use of chemotherapy for EBC.


Assuntos
Neoplasias da Mama , Humanos , Idoso , Feminino , Neoplasias da Mama/patologia , Quimioterapia Adjuvante , Terapia Neoadjuvante/métodos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
6.
Ann Surg Oncol ; 28(13): 8742-8751, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34279753

RESUMO

BACKGROUND: Poor patient-reported satisfaction after breast-conserving therapy (BCT) has been associated with impaired health-related quality of life (HRQOL) and subsequent depression in retrospective analysis. This prospective cohort study aimed to assess the HRQOL of patients who have undergone BCT using the BREAST-Q, and to identify clinical risk factors for lower patient satisfaction. METHODS: Patients with primary breast cancer undergoing BCT were asked to complete the BREAST-Q preoperatively (T1) for baseline evaluation, then 3 to 4 weeks postoperatively (T2), and finally 1 year after surgery (T3). Clinicopathologic data were extracted from the patients' charts. Repeated measures analysis of variance (ANOVA) was used to determine significant differences in mean satisfaction and well-being levels among the test intervals. Multiple linear regression was used to evaluate risk factors for lower satisfaction. RESULTS: The study enrolled 250 patients. The lowest baseline BREAST-Q score was reported for "satisfaction with breast" (mean, 61 ± 19), but this increased postoperatively (mean, 66 ± 18) and was maintained at the 1 year follow-up evaluation (mean, 67 ± 21). "Physical well-being" decreased from T1 (mean, 82 ± 17) to T2 (mean, 28 ± 13) and did not recover much by T3 (mean, 33 ± 13), being the lowest BREAST-Q score postoperatively and in the 1-year follow-up evaluation. In multiple regression, baseline psychosocial well-being, body mass index (BMI), and type of incision were risk factors for lower "satisfaction with breasts." CONCLUSION: Both the aesthetic/surgery-related and psychological aspects are equally important with regard to "satisfaction with breasts" after BCT. The data could serve as the benchmark for future studies.


Assuntos
Satisfação do Paciente , Qualidade de Vida , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Inquéritos e Questionários
7.
Eur Radiol ; 31(6): 3712-3720, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33313983

RESUMO

OBJECTIVE: The FUSION-X-US-II prototype was developed to combine 3D automated breast ultrasound (ABUS) and digital breast tomosynthesis in a single device. We evaluated the performance of ABUS and tomosynthesis in a single examination in a clinical setting. METHODS: In this prospective feasibility study, digital breast tomosynthesis and ABUS were performed using the FUSION-X-US-II prototype without any change of the breast position in patients referred for clarification of breast lesions with an indication for tomosynthesis. The tomosynthesis and ABUS images of the prototype were interpreted independently from the clinical standard by a breast diagnostics specialist. Any detected lesion was classified using BI-RADS® scores, and results of the standard clinical routine workup (gold standard) were compared to the result of the separate evaluation of the prototype images. Image quality was rated subjectively and coverage of the breast was measured. RESULTS: One hundred one patients received both ABUS and tomosynthesis using the prototype. The duration of the additional ABUS acquisition was 40 to 60 s. Breast coverage by ABUS was approximately 80.0%. ABUS image quality was rated as diagnostically useful in 86 of 101 cases (85.1%). Thirty-three of 34 malignant breast lesions (97.1%) were identified using the prototype. CONCLUSION: The FUSION-X-US-II prototype allows a fast ABUS scan in combination with digital breast tomosynthesis in a single device integrated in the clinical workflow. Malignant breast lesions can be localized accurately with direct correlation of ABUS and tomosynthesis images. The FUSION system shows the potential to improve breast cancer screening in the future after further technical improvements. KEY POINTS: • The FUSION-X-US-II prototype allows the combination of automated breast ultrasound and digital breast tomosynthesis in a single device without decompression of the breast. • Image quality and coverage of ABUS are sufficient to accurately detect malignant breast lesions. • If tomosynthesis and ABUS should become part of breast cancer screening, the combination of both techniques in one device could offer practical and logistic advantages. To evaluate a potential benefit of a combination of ABUS and tomosynthesis in screening-like settings, further studies are needed.


Assuntos
Neoplasias da Mama , Ultrassonografia Mamária , Mama/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Mamografia , Estudos Prospectivos , Sensibilidade e Especificidade
8.
Breast Cancer Res Treat ; 179(2): 425-433, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31654190

RESUMO

PURPOSE: To explore the ability of intraoperative specimen radiography (SR) to correctly identify positive margins in patients receiving breast conserving surgery (BCS). To assess whether the reoperation rate can be reduced by using this method. METHODS: This retrospective study included 470 consecutive cases receiving BCS due to a primarily diagnosed breast cancer. SR was carried out in two planes, assessing the specimen regarding the presence of the lesion and its relation to all margins. If indicated, re-excision of selective orientations was advised. Under consideration of gross inspection and the SR-findings, it was up to the surgeon whether to perform re-resections. The recommendations for re-excision were, separately for each orientation, compared to the histopathological results, serving as gold standard. RESULTS: Intraoperative SR was performed in 470 cases, thus 2820 margins were assessed. Of those, 2510 (89.0%) were negative and 310 (11.0%) positive. SR identified 2179 (77.3%) margins correctly as negative, whereas 331 (11.7%) clear margins were misjudged as positive. Of 310 infiltrated margins, SR identified 114 (4.0%) correctly, whereas 196 (7.0%) infiltrated margins were missed. This resulted in a sensitivity/specificity of 36.8%/86.8% and PPV/NPV of 25.6%/91.8%. Through targeted re-resections positive margins could be reduced by 31.0% [310 to 214 (7.6%)]. On case level, the rate of secondary procedures could be reduced by 37.0% [from 162 to 102 (21.7%)]. CONCLUSIONS: SR is a helpful tool to identify infiltrated margins and to reduce the rate of secondary surgeries by recommending targeted re-excisions of according orientations in order to obtain a final negative margin status.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/cirurgia , Cuidados Intraoperatórios , Mastectomia Segmentar , Radiografia , Idoso , Biópsia , Feminino , Humanos , Cuidados Intraoperatórios/métodos , Margens de Excisão , Mastectomia Segmentar/métodos , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radiografia/métodos , Cirurgia Assistida por Computador , Terapêutica , Resultado do Tratamento
9.
Breast J ; 25(6): 1251-1253, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31280490

RESUMO

Recently, it has been reported that IgG4-related disease may occur in the breast manifesting as nodular sclerosing interstitial mastitis. Here we report a case with multiple tumor-like nodules in one breast. The histologic diagnosis was established on core needle biopsies, and treatment was initiated without open biopsy. Diagnosis of IgG4-related sclerosing mastitis should be suspected in cases of tumor-like lesions on imaging with an interstitial plasma cell-rich sclerosing inflammation on histology.


Assuntos
Biópsia com Agulha de Grande Calibre/métodos , Mama , Mastite/patologia , Plasmócitos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Doença Relacionada a Imunoglobulina G4/diagnóstico , Doença Relacionada a Imunoglobulina G4/patologia , Doença Relacionada a Imunoglobulina G4/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Mastite/imunologia , Pessoa de Meia-Idade , Plasmócitos/imunologia , Plasmócitos/patologia , Esclerose , Ultrassonografia de Intervenção/métodos
10.
Breast Care (Basel) ; 19(2): 87-94, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38765898

RESUMO

Introduction: Pre-therapeutic histologic diagnosis through image-guided core needle biopsy (CNB) or vacuum-assisted biopsy (VAB) for suspicious breast findings is a standard procedure. Despite the moderate risk of bleeding, a significant proportion of patients are on temporary or permanent anti-coagulation therapy (ACT) or anti-platelet therapy (APT). Currently, there are no established guidelines for managing biopsies in such patients, leading to varying approaches in clinical practice. Methods: An online survey was conducted among all members of the breast ultrasound working group at the German Society for Ultrasound in Medicine (DEGUM) and the working group for breast diagnostics at the German Radiology Society (DRG). It included n = 51 questions about individual risk perception of biopsy-related bleeding complications and the specific management of biopsies on ACT/APT. Results: A total of 332 experts participated, with 51.8% reporting the absence of a standardized management plan for breast biopsies on ACT/APT. Concerning specific ACT/APT medications, the survey revealed discrepancies in risk perception and management: The majority preferred discontinuing medication with directly acting oral anti-coagulants (DOACs; CNB: 66.9%; VAB: 91.1%), phenprocoumon (CNB: 74.9%; VAB: 96.7%), or therapeutic heparin (CNB: 46.1%; VAB: 72.7%). However, there was a lower inclination to discontinue acetylsalicylic acid (ASA; CNB: 15.2%; VAB: 50.3%) or prophylactic heparin (CNB: 11.9%, VAB: 36.3%). Conclusion: Breast biopsies for patients on ASA or prophylactic heparin are deemed safe and part of standard clinical practice. However, despite available feasibility studies, conducting breast biopsies on ACT medications such as DOACs or phenprocoumon appears feasible only for a minority of experts.

11.
Breast ; 68: 194-200, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36842192

RESUMO

PURPOSE: The Histolog® Scanner (SamanTree Medical SA, Lausanne, Switzerland) is a large field-of-view confocal laser scanning microscope designed to allow intraoperative margin assessment by the production of histological images ready for assessment in the operating room. We evaluated the feasibility and the performance of the Histolog® Scanner (HS) to correctly identify infiltrated margins in clinical practice of lumpectomy specimens. It was extrapolated if the utilization of the HS has the potential to reduce infiltrated margins and therefore reduce re-operation rates in patients undergoing breast conserving surgery (BCS) due to a primarily diagnosed breast cancer including ductal carcinoma in situ. METHODS: This is a single-center, prospective, non-interventional, diagnostic pilot study including 50 consecutive patients receiving BCS. The complete surface of the specimen was scanned using the HS intraoperatively. The surgery and the intraoperative margin assessment of the specimen was performed according to the clinical routine consisting of conventional specimen radiography as well as the clinical impression of the surgeon. Three surgeons and an experienced pathologist assessed the scans produced by the HS for cancer cells on the surface. The potential of the HS to correctly identify involved margins was compared to the results of the conventional specimen radiography alone as well as the clinical routine. The histopathological report served as the gold standard. RESULTS: 50 specimens corresponding to 300 surfaces were scanned by the HS. The mean sensitivity of the surgeons to identify involved margins with the HS was 37.5% ± 5.6%, the specificity was 75.2% ± 13.0%. The assessment of resection margins by the pathologist resulted in a sensitivity of 37.5% and a specificity of 81.0%, while the local clinical routine resulted in a sensitivity of 37.5% and a specificity of 78.2%. CONCLUSION: Acquisition of high-resolution histological images using the HS was feasible in clinical practice. Sensitivity and specificity were comparable to clinical routine. With more specific training and experience on image interpretation and acquisition, the HS may have the potential to enable more accuracy in the margin assessment of BCS specimens.


Assuntos
Neoplasias da Mama , Carcinoma Ductal de Mama , Humanos , Feminino , Mastectomia Segmentar/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/cirurgia , Carcinoma Ductal de Mama/patologia , Estudos Prospectivos , Projetos Piloto , Margens de Excisão , Radiografia , Microscopia Confocal
12.
Br J Radiol ; 95(1139): 20220372, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36000742

RESUMO

OBJECTIVES: To define reference values for shear wave elastography (SWE) in unsuspicious axillary lymph nodes in patients undergoing breast ultrasound examination. METHODS: In total, 177 clinically and sonographically unsuspicious axillary lymph nodes were prospectively evaluated with SWE using Virtual Touch Tissue Imaging Quantification (VTIQ) in 175 women. Mean values of tissue stiffness for axillary fatty tissue, lymph node cortex, and lymph node hilus were measured. Additionally, test-retest reliability of SWE in the assessment of axillary lymph node stiffness was evaluated by repeating each measurement three times. RESULTS: In 177 axillary lymph nodes, the mean stiffness of lymph node cortex, hilus, and surrounding fatty tissue as quantified by SWE was 1.90 m/s (SD: 0.34 m/s), 2.02 m/s (SD: 0.37 m/s), and 1.75 m/s (SD: 0.38 m/s), respectively. The mean stiffness of cortex and hilus was significantly higher compared to fatty tissue (p < 0.0001). SWE demonstrated good test-retest reliability in the assessment of stiffness of the lymph node hilus, cortex, and the surrounding fatty tissue with an intraclass correlation of 0.79 (95% CI: 0.75; 0.83), 0.75 (95% CI: 0.70; 0.79), and 0.78 (95% CI: 0.74; 0.82), respectively, (p < 0.0001). CONCLUSIONS: Reference values for SWE in unsuspicious axillary lymph nodes are determined. These results may help to better identify axillary lymph node metastasis for breast cancer patients when combined with other lymph node features. SWE is a reliable method for the objective quantification of tissue stiffness of axillary lymph nodes. ADVANCES IN KNOWLEDGE: This study presents physiological reference values for tissue stiffness by examining the axillary lymph nodes with SWE in 175 women with sonomorphologically unsuspicious lymph nodes.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Técnicas de Imagem por Elasticidade/métodos , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos , Axila/patologia , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia
13.
Breast ; 58: 63-71, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33933924

RESUMO

BACKGROUND: Over the past decade, chemotherapy has been used more selectively in early breast cancer (EBC) due to better risk stratification. Neoadjuvant chemotherapy (NACT) has evolved to the primary treatment option. The type and size of hospitals is known to have a substantial influence on the kinds of treatment they provide, and therefore on patient outcomes (e.g. rates for pathological complete response, pCR), but it is not yet known how this has affected delivery of chemotherapy for EBC in Germany. METHODS: This study analyzed chemotherapy use and pCR rates after NACT for EBC patients treated at 104 German institutions 2008-2017. Institutions were separated into associated hospital type (university hospital; teaching hospital; community hospital) and annual caseload (≤100; 101-250; >250 cases/year). RESULTS: Overall, 124,084 patients were included, of whom 11.6% were treated at university hospitals, 63.1% at teaching hospitals, and 25.3% at community hospitals. In total, 46,274 (37.3%) received chemotherapy, of whom 44,765 had information available about systemic treatment and surgery. From 2008 to 2017, chemotherapy use declined from 48.3% to 36.4% for university hospitals, from 40.7% to 30.3% for teaching hospitals, and from 42.4% to 33.7% for community hospitals. Furthermore, the proportion of NACT increased the most in university hospitals (from 32.0% to 68.1%); whereas, the rate of pCR (defined as ypT0 ypN0) increased irrespective of institutional type. Analyses regarding annual caseload did not show any differences. CONCLUSIONS: The results from this large, nationwide cohort reflect a more selective use of chemotherapy in Germany, irrespective of institutional type or case load.


Assuntos
Neoplasias da Mama , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Quimioterapia Adjuvante , Feminino , Hospitais , Humanos , Terapia Neoadjuvante
14.
Eur J Radiol ; 128: 109025, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32371182

RESUMO

OBJECTIVE: To compare the validity of Shear Wave Elastography (SWE) for the preoperative assessment of pathological complete response (pCR) to standard clinical assessment in breast cancer patients undergoing neoadjuvant chemotherapy (NACT). MATERIALS AND METHODS: This prospective, consecutive clinical trial was conducted under routine clinical practice. Analysis included 134 patients. SWE served as index test, final pathology from surgical specimen as reference standard. PCR (ypT0) was defined as primary endpoint. Elasticity changes were compared for the pCR- vs. non-pCR group. To determine the validity of shear wave velocity (Vs), ROC analyses and diagnostic accuracy parameters were calculated and compared to the final standard clinical assessment by physical examination, mammography and B-mode ultrasound (ycT + vs. ycT0). RESULTS: Vs was significantly reduced in pCR and non-pCR groups during NACT (pCR: ΔVs(abs) = 3.90 m/s, p < 0.001; non-pCR: ΔVs(abs) = 3.10 m/s, p < 0.001). The pCR-group showed significant lower Vs for all control visits (t1,2,END: p < 0.001). ROC analysis of Vs yielded moderate AUCs for the total population (t0: 0.613, t1: 0.745, t2: 0.685, tEND: 0.718). Compared to standard clinical assessment, Vs(tEND) (cut-off: ≤3.35 m/s) was superior in sensitivity (79.6 % vs. 54.5 %), NPV (86.4 % vs. 77.5 %), FNR (20.4 % vs. 45.5 %), inferior in specificity (58.6 % vs. 77.5 %), PPV (46.3 % vs. 54.5 %), FPR (41.4 % vs. 22.5 %). CONCLUSION: SWE measures significant differences in tumour elasticity changes in pCR vs. non-pCR cases. SWE shows improved sensitivity compared to standard clinical assessment, high NPV and low FNR, but failed in specificity in order to predict pCR under routine conditions.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Técnicas de Imagem por Elasticidade/métodos , Terapia Neoadjuvante/métodos , Ultrassonografia Mamária/métodos , Área Sob a Curva , Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento