Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
1.
Anal Bioanal Chem ; 413(22): 5669-5678, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34244834

RESUMO

Plant viruses are major contributors to crop losses and induce high economic costs worldwide. For reliable, on-site and early detection of plant viral diseases, portable biosensors are of great interest. In this study, a field-effect SiO2-gate electrolyte-insulator-semiconductor (EIS) sensor was utilized for the label-free electrostatic detection of tobacco mosaic virus (TMV) particles as a model plant pathogen. The capacitive EIS sensor has been characterized regarding its TMV sensitivity by means of constant-capacitance method. The EIS sensor was able to detect biotinylated TMV particles from a solution with a TMV concentration as low as 0.025 nM. A good correlation between the registered EIS sensor signal and the density of adsorbed TMV particles assessed from scanning electron microscopy images of the SiO2-gate chip surface was observed. Additionally, the isoelectric point of the biotinylated TMV particles was determined via zeta potential measurements and the influence of ionic strength of the measurement solution on the TMV-modified EIS sensor signal has been studied.


Assuntos
Vírus do Mosaico do Tabaco/isolamento & purificação , Vírion/isolamento & purificação , Produtos Agrícolas/virologia , Espectroscopia Dielétrica , Microscopia Eletrônica de Varredura , Concentração Osmolar , Eletricidade Estática
2.
Sensors (Basel) ; 21(18)2021 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-34577368

RESUMO

The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed.


Assuntos
Eletrólitos , Semicondutores , Capacitância Elétrica
3.
Sensors (Basel) ; 20(19)2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33023133

RESUMO

Electrolyte-insulator-semiconductor (EIS) field-effect sensors belong to a new generation of electronic chips for biochemical sensing, enabling a direct electronic readout. The review gives an overview on recent advances and current trends in the research and development of chemical sensors and biosensors based on the capacitive field-effect EIS structure-the simplest field-effect device, which represents a biochemically sensitive capacitor. Fundamental concepts, physicochemical phenomena underlying the transduction mechanism and application of capacitive EIS sensors for the detection of pH, ion concentrations, and enzymatic reactions, as well as the label-free detection of charged molecules (nucleic acids, proteins, and polyelectrolytes) and nanoparticles, are presented and discussed.


Assuntos
Técnicas Biossensoriais , Eletrólitos , Semicondutores , Polieletrólitos
4.
Sensors (Basel) ; 20(17)2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32878210

RESUMO

Multi-enzyme immobilization onto a capacitive field-effect biosensor by nano-spotting technique is presented. The nano-spotting technique allows to immobilize different enzymes simultaneously on the sensor surface with high spatial resolution without additional photolithographical patterning. The amount of applied enzymatic cocktail on the sensor surface can be tailored. Capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors with Ta2O5 as pH-sensitive transducer layer have been chosen to immobilize the three different (pL droplets) enzymes penicillinase, urease, and glucose oxidase. Nano-spotting immobilization is compared to conventional drop-coating method by defining different geometrical layouts on the sensor surface (fully, half-, and quarter-spotted). The drop diameter is varying between 84 µm and 102 µm, depending on the number of applied drops (1 to 4) per spot. For multi-analyte detection, penicillinase and urease are simultaneously nano-spotted on the EIS sensor. Sensor characterization was performed by C/V (capacitance/voltage) and ConCap (constant capacitance) measurements. Average penicillin, glucose, and urea sensitivities for the spotted enzymes were 81.7 mV/dec, 40.5 mV/dec, and 68.9 mV/dec, respectively.


Assuntos
Técnicas Biossensoriais , Capacitância Elétrica , Enzimas Imobilizadas , Semicondutores , Urease
5.
Sensors (Basel) ; 20(6)2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32192226

RESUMO

In this review article, we are going to present an overview on possible applications of light-addressable electrodes (LAE) as actuator/manipulation devices besides classical electrode structures. For LAEs, the electrode material consists of a semiconductor. Illumination with a light source with the appropiate wavelength leads to the generation of electron-hole pairs which can be utilized for further photoelectrochemical reaction. Due to recent progress in light-projection technologies, highly dynamic and flexible illumination patterns can be generated, opening new possibilities for light-addressable electrodes. A short introduction on semiconductor-electrolyte interfaces with light stimulation is given together with electrode-design approaches. Towards applications, the stimulation of cells with different electrode materials and fabrication designs is explained, followed by analyte-manipulation strategies and spatially resolved photoelectrochemical deposition of different material types.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Luz , Semicondutores , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Materiais Revestidos Biocompatíveis/síntese química , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/provisão & distribuição , Materiais Revestidos Biocompatíveis/uso terapêutico , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Galvanoplastia/instrumentação , Galvanoplastia/métodos , Desenho de Equipamento , Humanos , Iluminação/instrumentação , Iluminação/métodos , Microtecnologia/métodos
6.
Anal Chem ; 91(23): 15293-15299, 2019 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-31674761

RESUMO

A facile approach for the construction of reagent-free electrochemical dehydrogenase-based biosensors is presented. Enzymes and cofactors (NAD+ and Fe(CN)63-) were immobilized by modification of screen-printed carbon electrodes with graphene oxide (GO) and an additional layer of cellulose acetate. The sensor system was exemplarily optimized for an l-lactate electrode in terms of GO concentration, working potential, and pH value. The biosensor exhibited best characteristics at pH 7.5 in 100 mM potassium phosphate buffer at an applied potential of +0.250 V versus an internal pseudo Ag reference electrode. Thereby, sensor performance was characterized by a linear working range from 0.25 to 4 mM and a sensitivity of 0.14 µA mM-1. The detection principle was additionally evaluated with three other dehydrogenases (d-lactate dehydrogenase, alcohol dehydrogenase, and formate dehydrogenase, respectively). The developed reagentless biosensor array enabled simultaneous and cross-talk free determination of l-lactate, d-lactate, ethanol, and formate.


Assuntos
Técnicas Biossensoriais , Carbono/química , Técnicas Eletroquímicas , Grafite/química , NAD/química , Oxirredutases/química , Carbono/metabolismo , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Etanol/análise , Etanol/metabolismo , Ferricianetos/química , Ferricianetos/metabolismo , Formiatos/análise , Formiatos/metabolismo , Grafite/metabolismo , Concentração de Íons de Hidrogênio , Ácido Láctico/análise , Ácido Láctico/metabolismo , NAD/metabolismo , Oxirredutases/metabolismo , Prata/química
7.
Sensors (Basel) ; 19(21)2019 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-31671716

RESUMO

Monitoring the cellular metabolism of bacteria in (bio)fermentation processes is crucial to control and steer them, and to prevent undesired disturbances linked to metabolically inactive microorganisms. In this context, cell-based biosensors can play an important role to improve the quality and increase the yield of such processes. This work describes the simultaneous analysis of the metabolic behavior of three different types of bacteria by means of a differential light-addressable potentiometric sensor (LAPS) set-up. The study includes Lactobacillus brevis, Corynebacterium glutamicum, and Escherichia coli, which are often applied in fermentation processes in bioreactors. Differential measurements were carried out to compensate undesirable influences such as sensor signal drift, and pH value variation during the measurements. Furthermore, calibration curves of the cellular metabolism were established as a function of the glucose concentration or cell number variation with all three model microorganisms. In this context, simultaneous (bio)sensing with the multi-organism LAPS-based set-up can open new possibilities for a cost-effective, rapid detection of the extracellular acidification of bacteria on a single sensor chip. It can be applied to evaluate the metabolic response of bacteria populations in a (bio)fermentation process, for instance, in the biogas fermentation process.


Assuntos
Bactérias/metabolismo , Técnicas Biossensoriais , Luz , Potenciometria , Bactérias/efeitos dos fármacos , Bactérias/crescimento & desenvolvimento , Calibragem , Contagem de Colônia Microbiana , Eletrodos , Glucose/farmacologia
8.
Anal Chem ; 90(12): 7747-7753, 2018 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-29770694

RESUMO

Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results.


Assuntos
Técnicas Biossensoriais/métodos , DNA Bacteriano/genética , Técnicas Eletroquímicas , Mycobacterium tuberculosis/genética , Polieletrólitos/química , Reação em Cadeia da Polimerase , Semicondutores , Benzotiazóis , DNA Bacteriano/análise , Diaminas , Técnicas Eletroquímicas/instrumentação , Corantes Fluorescentes/química , Técnicas de Amplificação de Ácido Nucleico/instrumentação , Compostos Orgânicos/química , Quinolinas
9.
Langmuir ; 34(9): 3082-3093, 2018 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-29397738

RESUMO

Algal polysaccharides (extracellular polysaccharides) and carbon nanotubes (CNTs) were adsorbed on dioctadecyldimethylammonium bromide Langmuir monolayers to serve as a matrix for the incorporation of urease. The physicochemical properties of the supramolecular system as a monolayer at the air-water interface were investigated by surface pressure-area isotherms, surface potential-area isotherms, interfacial shear rheology, vibrational spectroscopy, and Brewster angle microscopy. The floating monolayers were transferred to hydrophilic solid supports, quartz, mica, or capacitive electrolyte-insulator-semiconductor (EIS) devices, through the Langmuir-Blodgett (LB) technique, forming mixed films, which were investigated by quartz crystal microbalance, fluorescence spectroscopy, and field emission gun scanning electron microscopy. The enzyme activity was studied with UV-vis spectroscopy, and the feasibility of the thin film as a urea sensor was essayed in an EIS sensor device. The presence of CNT in the enzyme-lipid LB film not only tuned the catalytic activity of urease but also helped to conserve its enzyme activity. Viability as a urease sensor was demonstrated with capacitance-voltage and constant capacitance measurements, exhibiting regular and distinctive output signals over all concentrations used in this work. These results are related to the synergism between the compounds on the active layer, leading to a surface morphology that allowed fast analyte diffusion owing to an adequate molecular accommodation, which also preserved the urease activity. This work demonstrates the feasibility of employing LB films composed of lipids, CNT, algal polysaccharides, and enzymes as EIS devices for biosensing applications.


Assuntos
Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/metabolismo , Nanotubos de Carbono/química , Polissacarídeos/química , Urease/metabolismo , Brometos/química , Enzimas Imobilizadas/química , Lipídeos/química , Compostos de Amônio Quaternário/química , Espectrometria de Fluorescência , Propriedades de Superfície , Urease/química
10.
Sensors (Basel) ; 18(5)2018 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-29738487

RESUMO

Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at −21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at −21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media.

11.
Chemphyschem ; 18(12): 1541-1551, 2017 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-28301717

RESUMO

We study the mechanisms involved in the release, triggered by the application of glucose, of insulin entrapped in Fe3+ -cross-linked alginate hydrogel particles further stabilized with a polyelectrolyte. Platelet-shaped alginate particles are synthesized containing enzyme glucose oxidase conjugated with silica nanoparticles, which are also entrapped in the hydrogel. Glucose diffuses in from solution, and production of hydrogen peroxide is catalyzed by the enzyme within the hydrogel. We argue that, specifically for the Fe3+ -cross-linked systems, the produced hydrogen peroxide is further converted to free radicals via a Fenton-type reaction catalyzed by the iron cations. The activity of free radicals, as well as the reduction of Fe3+ by the enzyme, and other mechanisms contribute to the decrease in density of the hydrogel. As a result, while the particles remain intact, void sizes increase and release of insulin ensues and is followed experimentally. A theoretical description of the involved processes is proposed and utilized to fit the data. It is then used to study the long-time properties of the release process that offers a model for designing new drug-release systems.


Assuntos
Reagentes de Ligações Cruzadas/metabolismo , Compostos Férricos/metabolismo , Glucose Oxidase/metabolismo , Glucose/metabolismo , Hidrogéis/metabolismo , Insulina/metabolismo , Reagentes de Ligações Cruzadas/química , Compostos Férricos/química , Glucose/química , Glucose Oxidase/química , Hidrogéis/química , Insulina/química , Modelos Moleculares , Nanopartículas/química , Nanopartículas/metabolismo , Tamanho da Partícula , Dióxido de Silício/química , Dióxido de Silício/metabolismo
12.
Anal Bioanal Chem ; 409(1): 81-94, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27900435

RESUMO

The paper is an overview of enzyme-based logic gates and their short circuits, with specific examples of Boolean AND and OR gates, and concatenated logic gates composed of multi-step enzyme-biocatalyzed reactions. Noise formation in the biocatalytic reactions and its decrease by adding a "filter" system, converting convex to sigmoid response function, are discussed. Despite the fact that the enzyme-based logic gates are primarily considered as components of future biomolecular computing systems, their biosensing applications are promising for immediate practical use. Analytical use of the enzyme logic systems in biomedical and forensic applications is discussed and exemplified with the logic analysis of biomarkers of various injuries, e.g., liver injury, and with analysis of biomarkers characteristic of different ethnicity found in blood samples on a crime scene. Interfacing of enzyme logic systems with modified electrodes and semiconductor devices is discussed, giving particular attention to the interfaces functionalized with signal-responsive materials. Future perspectives in the design of the biomolecular logic systems and their applications are discussed in the conclusion. Graphical Abstract Various applications and signal-transduction methods are reviewed for enzyme-based logic systems.


Assuntos
Técnicas Biossensoriais/instrumentação , Computadores Moleculares , Animais , Biocatálise , Técnicas Biossensoriais/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Desenho de Equipamento , Humanos , Modelos Moleculares , Semicondutores , Transdutores
13.
Anal Chem ; 87(13): 6607-13, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26016927

RESUMO

Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte-insulator-semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(D,L-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers.


Assuntos
Materiais Biocompatíveis , Técnicas Biossensoriais , Polímeros/química , Biocatálise , Microscopia de Força Atômica
14.
Sensors (Basel) ; 15(10): 26115-27, 2015 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-26473883

RESUMO

In this work, a sensor to evaluate sterilization processes with hydrogen peroxide vapor has been characterized. Experimental, analytical and numerical methods were applied to evaluate and study the sensor behavior. The sensor set-up is based on planar interdigitated electrodes. The interdigitated electrode structure consists of 614 electrode fingers spanning over a total sensing area of 20 mm². Sensor measurements were conducted with and without microbiological spores as well as after an industrial sterilization protocol. The measurements were verified using an analytical expression based on a first-order elliptical integral. A model based on the finite element method with periodic boundary conditions in two dimensions was developed and utilized to validate the experimental findings.


Assuntos
Análise de Elementos Finitos , Esterilização , Eletrodos , Peróxido de Hidrogênio/análise , Esterilização/instrumentação , Esterilização/métodos , Esterilização/normas
15.
Anal Chem ; 86(15): 7867-74, 2014 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-24999077

RESUMO

This study describes a label-free impedimetric sensor based on short ssDNA recognition elements for the detection of hybridization events. We concentrate on the elucidation of the influence of target length and recognition sequence position on the sensorial performance. The impedimetric measurements are performed in the presence of the redox system ferri-/ferrocyanide and show an increase in charge transfer resistance upon hybridization of ssDNA to the sensor surface. Investigations on the impedimetric signal stability demonstrate a clear influence of the buffers used during the sensor preparation and the choice of the passivating mercaptoalcanol compound. A stable sensor system has been developed, enabling a reproducible detection of 25mer target DNA in the low nanomolar range. After hybridization, a sensor regeneration can be reached with deionized water by adjustment of effective convection conditions, ensuring a sensor reusability. By investigations of longer targets with overhangs exposed to the solution, we can demonstrate applicability of the impedimetric detection for longer ssDNA. However, a decreasing charge transfer resistance change (ΔR(ct)) is found by extending the overhang. As a strategy to increase the impedance change for longer target strands, the position of the recognition sequence can be designed in a way that a small overhang is exposed to the electrode surface. This is found to result in an increase in the relative R(ct) change. These results suggest that DNA and consequently negative charge near the electrode possess a larger impact on the impedimetric signal than DNA further away.


Assuntos
Técnicas Biossensoriais , DNA de Cadeia Simples/análise , Sequência de Bases , Oxirredução
16.
Anal Chem ; 86(11): 5370-5, 2014 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-24814256

RESUMO

The ideal combination among biomolecules and nanomaterials is the key for reaching biosensing units with high sensitivity. The challenge, however, is to find out a stable and sensitive film architecture that can be incorporated on the sensor's surface. In this paper, we report on the benefits of incorporating a layer-by-layer (LbL) nanofilm of polyamidoamine (PAMAM) dendrimer and carbon nanotubes (CNTs) on capacitive electrolyte-insulator-semiconductor (EIS) field-effect sensors for detecting urea. Three sensor arrangements were studied in order to investigate the adequate film architecture, involving the LbL film with the enzyme urease: (i) urease immobilized directly onto a bare EIS [EIS-urease] sensor; (ii) urease atop the LbL film over the EIS [EIS-(PAMAM/CNT)-urease] sensor; and (iii) urease sandwiched between the LbL film and another CNT layer [EIS-(PAMAM/CNT)-urease-CNT]. The surface morphology of all three urea-based EIS biosensors was investigated by atomic force microscopy (AFM), while the biosensing abilities were studied by means of capacitance-voltage (C/V) and dynamic constant-capacitance (ConCap) measureaments at urea concentrations ranging from 0.1 mM to 100 mM. The EIS-urease and EIS-(PAMAM/CNT)-urease sensors showed similar sensitivity (~18 mV/decade) and a nonregular signal behavior as the urea concentration increased. On the other hand, the EIS-(PAMAM/CNT)-urease-CNT sensor exhibited a superior output signal performance and higher sensitivity of about 33 mV/decade. The presence of the additional CNT layer was decisive to achieve a urea based EIS sensor with enhanced properties. Such sensitive architecture demonstrates that the incorporation of an adequate hybrid enzyme-nanofilm as sensing unit opens new prospects for biosensing applications using the field-effect sensor platform.


Assuntos
Técnicas Biossensoriais/métodos , Nanotubos de Carbono/química , Ureia/análise , Urease/química , Dendrímeros/química , Enzimas Imobilizadas/química , Microscopia de Força Atômica , Semicondutores
17.
Analyst ; 139(8): 1839-42, 2014 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-24603754

RESUMO

An enzyme system organized in a flow device was used to mimic a reversible Controlled NOT (CNOT) gate with two input and two output signals. Reversible conversion of NAD(+) and NADH cofactors was used to perform a XOR logic operation, while biocatalytic hydrolysis of p-nitrophenyl phosphate resulted in an Identity operation working in parallel. The first biomolecular realization of a CNOT gate is promising for integration into complex biomolecular networks and future biosensor/biomedical applications.


Assuntos
Enzimas/metabolismo , NAD/metabolismo , Biocatálise , Hidrólise , Nitrofenóis/metabolismo , Compostos Organofosforados/metabolismo
18.
Biosens Bioelectron ; 261: 116491, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38879900

RESUMO

As one class of molecular imprinted polymers (MIPs), surface imprinted polymer (SIP)-based biosensors show great potential in direct whole-bacteria detection. Micro-contact imprinting, that involves stamping the template bacteria immobilized on a substrate into a pre-polymerized polymer matrix, is the most straightforward and prominent method to obtain SIP-based biosensors. However, the major drawbacks of the method arise from the requirement for fresh template bacteria and often non-reproducible bacteria distribution on the stamp substrate. Herein, we developed a positive master stamp containing photolithographic mimics of the template bacteria (E. coli) enabling reproducible fabrication of biomimetic SIP-based biosensors without the need for the "real" bacteria cells. By using atomic force and scanning electron microscopy imaging techniques, respectively, the E. coli-capturing ability of the SIP samples was tested, and compared with non-imprinted polymer (NIP)-based samples and control SIP samples, in which the cavity geometry does not match with E. coli cells. It was revealed that the presence of the biomimetic E. coli imprints with a specifically designed geometry increases the sensor E. coli-capturing ability by an "imprinting factor" of about 3. These findings show the importance of geometry-guided physical recognition in bacterial detection using SIP-based biosensors. In addition, this imprinting strategy was employed to interdigitated electrodes and QCM (quartz crystal microbalance) chips. E. coli detection performance of the sensors was demonstrated with electrochemical impedance spectroscopy (EIS) and QCM measurements with dissipation monitoring technique (QCM-D).


Assuntos
Aderência Bacteriana , Técnicas Biossensoriais , Escherichia coli , Polímeros , Escherichia coli/isolamento & purificação , Polímeros/química , Impressão Molecular/métodos , Propriedades de Superfície , Polímeros Molecularmente Impressos/química , Infecções por Escherichia coli/microbiologia , Materiais Biomiméticos/química
19.
ACS Sens ; 9(3): 1533-1544, 2024 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-38445576

RESUMO

The miniaturization of microfluidic systems usually comes at the cost of more difficult integration of sensors and actuators inside the channel. As an alternative, this work demonstrates the embedding of semiconductor-based sensor and actuator technologies that can be spatially and temporally controlled from outside the channel using light. The first element is a light-addressable potentiometric sensor, consisting of an Al/Si/SiO2/Si3N4 structure, that can measure pH changes at the Si3N4/electrolyte interface. The pH value is a crucial factor in biological and chemical systems, and besides measuring, it is often important to bring the system out of equilibrium or to adjust and control precisely the surrounding medium. This can be done photoelectrocatalytically by utilizing light-addressable electrodes. These consist of a glass/SnO2:F/TiO2 structure, whereby direct charge transfer between the TiO2 and the electrolyte leads to a pH change upon irradiation. To complement the advantages of both, we integrated a light-addressable sensor with a pH sensitivity of 41.5 mV·pH-1 and a light-addressable electrode into a microfluidic setup. Here, we demonstrated a simultaneous operation with the ability to generate and record pH gradients inside a channel under static and dynamic flow conditions. The results show that dependent on the light-addressable electrode (LAE)-illumination conditions, pH changes up to ΔpH of 2.75 and of 3.52 under static and dynamic conditions, respectively, were spatially monitored by the light-addressable potentiometric sensor. After flushing with fresh buffer solution, the pH returned to its initial value. Depending on the LAE illumination, pH gradients with a maximum pH change of ΔpH of 1.42 were tailored perpendicular to the flow direction. In a final experiment, synchronous LAE illumination led to a stepwise increase in the pH inside the channel.


Assuntos
Técnicas Biossensoriais , Luz , Dióxido de Silício , Técnicas Biossensoriais/métodos , Eletrólitos , Dispositivos Lab-On-A-Chip , Concentração de Íons de Hidrogênio
20.
Micromachines (Basel) ; 15(6)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38930725

RESUMO

In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems.

SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa