RESUMO
BACKGROUND: Polymer-coating represents a key component of drug-eluting stent (DES) technology and its possible impact on vessel-wall healing is a matter of debate. The clinical impact of different polymer-coating may be assessed by comparing the outcome of patients treated by DES having the same stent platform and drug, and differing in the polymer. Thus, we compared the clinical outcome of patients treated by Endeavor Zotarolimus-eluting stent (E-ZES) and Resolute Zotarolimus-eluting stent (R-ZES) as they differ in the polymer-coating only. METHODS: At our Institution, E-ZES was available during a first period and then it was substituted by the R-ZES during a second period. Clinical, angiographic, and procedural data were prospectively collected. Clinical follow-up was prospectively obtained up to 1-year. Primary endpoint was the occurrence of major adverse cardiac events (MACE) at 12-month. RESULTS: A total of 467 patients undergoing percutaneous coronary intervention were enrolled: 233 patients treated with E-ZES and 234 with R-ZES. Patients treated by R-ZES had similar clinical characteristics and worse angiographic characteristics compared with those treated by E-ZES. At 12-month follow-up, MACE rate was significantly lower in the R-ZES group compared with E-ZES group (4.2% vs. 14.6%; P < 0.01). This difference was due to nonsignificantly lower rates of death and myocardial infarction and to significant lower rate of target-lesion-revascularization (R-ZES 3.4% vs. E-ZES 10.3%, P < 0.01). CONCLUSIONS: The results of this study suggest that the clinical outcome of patients treated by DES differing for the polymer coating only may be different. Polymer coating is a pivotal, probably underrated, component of DES technology which may influence the clinical performance of DES.
Assuntos
Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/análogos & derivados , Idoso , Angiografia Coronária , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Cidade de Roma , Sirolimo/administração & dosagem , Trombose/etiologia , Trombose/mortalidade , Fatores de Tempo , Resultado do TratamentoRESUMO
BACKGROUND: Randomized trials have shown that transradial approach, compared with transfemoral, reduces vascular complications (VCs) of coronary procedures in selected patients. Yet, radial approach is associated to a variety of access-site VC as well as to a higher failure rate compared with femoral access. METHODS: At our institution, from May 2005 to May 2010, we prospectively assessed the occurrence and outcome of VC in consecutive patients undergoing transradial percutaneous coronary procedures performed by trained radial operators. The need of access crossover to complete the procedure was also prospectively investigated. Vascular complications were classified as "radial related" or "nonradial related" (in the case of access crossover). Vascular complications were also classified "major" if requiring surgery and/or blood transfusions or causing hemoglobin drop >3 g/dL. RESULTS: Ten thousand six hundred seventy-six procedures were performed using a right radial (87.5%), left radial (12.4%), or ulnar (0.1%) artery as primary access. A total of 53 VCs (0.5%) were observed: 44 (83%) radial related and 9 (17%) nonradial related. Major VCs occurred in 16 patients only (0.2%) and were radial related in 10 (62.5%) and nonradial related in 6 (37.5%) patients. Vascular complications rate was stable during the study and independent of operator's experience. Access crossover rate was 4.9%, differed according to the operator radial experience and significantly decreased over time. CONCLUSIONS: The present study, conducted in a center with high volume of radial procedures, shows that transradial approach is associated with a very low rate of VC, which is stable over time. On the contrary, access crossover rate decreased over time and differed according to operator (radial) experience.
Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Cateterismo Cardíaco/efeitos adversos , Infarto do Miocárdio/terapia , Artéria Radial , Doenças Vasculares/etiologia , Idoso , Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Feminino , Seguimentos , Humanos , Incidência , Itália/epidemiologia , Masculino , Estudos Prospectivos , Fatores de Risco , Doenças Vasculares/epidemiologiaRESUMO
BACKGROUND: Trans-radial approach (TRA) reduces vascular access-site complications but has some technical limitations. Usually, TRA procedures are performed using 5 Fr or 6 Fr sheaths, whereas complex interventions requiring larger sheaths are approached by trans-femoral access. METHODS: During 4 years, at two Institutions with high TRA use, we have attempted to perform selected complex coronary or peripheral interventions by TRA using sheaths larger than 6 Fr. Clinical and procedural data were prospectively collected. Attempt to place a 7 Fr or 8 Fr sheath (according to the planned strategy of the procedure) was performed after 5-6 Fr sheath insertion, administration of intra-arterial nitrates and radial artery angiography. Late (>3 months) patency of the radial artery was checked (by angiography in the case of repeated procedures or by palpation + reverse Allen test). RESULTS: We collected 60 patients in which TRA large sheath insertion was attempted. The large sheath (87% 7 Fr, 13% 8 Fr) was successfully placed in all cases. Most of the procedures were complex coronary interventions (bifurcated or highly thrombotic or calcific chronic total occlusive lesions), whereas 8.3% were carotid interventions. Procedural success rate was 98.3% (1 failure to reopen a chronic total occlusion). No access-site related complication occurred. In 57 (95%) patients, late radial artery patency was assessed and showed patency in 90% of the cases, the remaining patients having asymptomatic collateralized occlusion. CONCLUSIONS: In selected patients, complex percutaneous interventions requiring 7-8 Fr sheaths can be successfully performed by RA approach without access-site clinical consequences.
Assuntos
Cateterismo Cardíaco , Doenças das Artérias Carótidas/terapia , Cateterismo Periférico , Catéteres , Doença das Coronárias/terapia , Artéria Radial , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Palpação , Estudos Prospectivos , Artéria Radial/diagnóstico por imagem , Artéria Radial/fisiopatologia , Radiografia , Espanha , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
Drug-eluting stents (DES) have revolutionized the treatment of coronary bifurcation lesions. Among different DES types, sirolimus-eluting stents (SES) showed better outcomes than paclitaxel-eluting stents. Because novel sirolimus analogues have been implemented in DES, a prospective observational comparison was undertaken to compare major mammalian target of rapamycin inhibitor-eluting stents in the treatment of bifurcation lesions according to the provisional T-stenting and small protrusion (TAP) technique. Overall, 187 patients (165 men, 65 ± 10 years) were enrolled in the study: 80 patients received a SES, whereas zotarolimus-eluting stents (ZES) were implanted in 53 patients and everolimus-eluting stents (EvES) in 62 patients. Primary end-point of the study was the 12-month incidence of target bifurcation failure (TBF) defined as occurrence of cardiovascular death, nonfatal myocardial infarction (MI), and target vessel revascularization (TVR) or angiographic documentation of > 50% restenosis on the main vessel or TIMI flow < 3 on the side branch. Groups were homogeneous according to main clinical and angiographic characteristics. Overall, 17 (9.1%) patients had TBF: 4 (2.1%) patients had nonfatal non-ST-segment elevation MI, 9 (4.8%) patients underwent TVR, and 6 (3.2%) patients had an angiographic restenosis. The rate of TBF was statistically different among the three groups (7.9% in SES group, 18% in ZES group, and 3.3% in EvES group, P = 0.024). Previous MI was associated with a worse outcome (P = 0.025), whereas final kissing balloon was associated with a better outcome (P = 0.045). In conclusion, in this prospective registry, significant differences between DES were found in the outcome of patients treated for coronary bifurcation lesions according to provisional TAP technique. Thus, prospective randomized trials in this field are needed.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Estenose Coronária/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Serina-Treonina Quinases TOR/antagonistas & inibidores , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Angiografia Coronária , Reestenose Coronária/etiologia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Everolimo , Feminino , Humanos , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: To investigate the role of renal stenting in selected patients with chronic ischemic heart disease and renal artery stenosis. METHODS: Consecutive patients, with chronic ischemic heart disease and severe hypertension and/or impaired renal function undergoing renal stenting, were prospectively enrolled. Mid-term (at least 2 years) follow-up was performed to assess both changes in renal function [serum creatinine and estimated glomerular filtrate rate (eGFR)] and blood pressure (BP) control (number of required drugs) and to record the incidence of clinical major adverse events. Moreover, in the first consecutive 24 patients, out-of-range pressure values at 24-hr BP monitoring and GFR at renal scintigraphy were measured at baseline and 1 month after stenting. RESULTS: Seventy patients treated by stenting on 86 renal arteries entered the study. Procedural success rate was 99% and no major complication occurred. At 2-year follow-up, both mean serum creatinine (-0.1 +/- 0.7 mg/dl at follow-up compared to baseline, P = 0.6) and eGFR (+3.7 +/- 23.5 ml/min/1.73m(2) at follow-up compared to baseline, P = 0.2) did not significantly change while the number of drugs required to control BP significantly decreased (2.7 +/- 0.8 to 2.2 +/- 0.7, P < 0.0001). In the subset of 24 patients evaluated at 1 month, GFR significantly increased (62 +/- 20 ml/min to 67 +/- 21 ml/min; P = 0.008) and the rate of the out-of-range systolic pressure values at 24-hr monitoring significantly decreased (51-33%, P = 0.005). Elevated baseline creatinine values and the presence of global renal ischemia were identified as predictors of poor outcome at the multivariate analysis. CONCLUSIONS: In selected patients with chronic ischemic heart disease and hypertension and/or renal insufficiency, renal stenting may be performed with very low periprocedural complications and results in unchanged renal function and improved BP control.
Assuntos
Angioplastia/instrumentação , Hipertensão Renovascular/terapia , Isquemia Miocárdica/complicações , Obstrução da Artéria Renal/terapia , Stents , Idoso , Angioplastia/efeitos adversos , Anti-Hipertensivos/uso terapêutico , Biomarcadores/sangue , Pressão Sanguínea , Distribuição de Qui-Quadrado , Doença Crônica , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Humanos , Hipertensão Renovascular/sangue , Hipertensão Renovascular/etiologia , Hipertensão Renovascular/fisiopatologia , Itália , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/sangue , Isquemia Miocárdica/fisiopatologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Obstrução da Artéria Renal/sangue , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/fisiopatologia , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do TratamentoRESUMO
OBJECTIVES: To investigate the outcome of patients undergoing percutaneous coronary interventions (PCI) with implantation of a new thin-strut cobalt-chromium bare-metal-stent (BMS) in the drug-eluting-stent (DES) era. BACKGROUND: Despite the contemporary penetration of DES in the clinical practice, a relevant percentage of patients are still treated by BMS. Data on clinical outcome of novel BMSs are lacking. METHODS: This is a single-centre-registry enrolling patients treated by Skylor stent implantation. During the study, the criteria for BMS selection adopted at our institution ("internal" criteria) were as follows: (1) limited compliance to prolonged double antiplatelet therapy, (2) ST-elevation myocardial infarction (STEMI) or saphenous vein grafts (SVG) interventions, and (3) in the absence of these conditions, noncomplex (no bifurcations, no chronic total occlusions) lesions considered at low restenosis risk on the basis of arbitrary angiographic criteria (short lesions, large vessels). Primary and secondary end-points were respectively major adverse cardiovascular events (MACE) and target vessel failure (TVF) up to 9-month. RESULTS: A total of 150 patients were treated with Skylor stent on 169 lesions. At 9-month follow-up, MACE occurred in 12 patients (8.0%) and TVF in 21 lesions (12.4%). By multivariable analysis, the predictors of MACE were Euroscore>or=9 and ejection fraction < 30% while the predictors of TVF were the absence of the angiographic criteria of low restenosis risk and ejection fraction < 30%. CONCLUSIONS: In the DES era, the use of a last-generation BMS in patients with limited compliance to double antiplatelet therapy, STEMI or SVG interventions, and noncomplex angiographic lesions may be associated with acceptable clinical outcome.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Ligas de Cromo , Doença da Artéria Coronariana/terapia , Stents , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/prevenção & controle , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Stents Farmacológicos , Feminino , Humanos , Itália , Masculino , Adesão à Medicação , Pessoa de Meia-Idade , Seleção de Pacientes , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do TratamentoRESUMO
Overlapping homogenous drug-eluting stents (DESs) may be used instead of overlapping bare metal stents (BMSs) to treat coronary lesions longer than available stents. Yet, no data are available on patients treated with overlapping heterogenous DESs or DESs and BMSs. We prospectively assessed 9-month clinical outcome and 6-month angiographic late loss (evaluated at 5 different lesion segments) in a consecutive series of 40 patients who received overlapping homogenous DESs (sirolimus-eluting stent [SES] or paclitaxel-eluting stent [PES]), heterogenous DESs (SES + PES), or overlapping DESs and BMSs. In 8 patients (7 with angiographic follow-up) with overlapping heterogenous DESs, no angiographic or clinical adverse event was observed. Moreover, in-segment late loss was similar to that of patients who received homogenous DESs. In 8 patients (7 with angiographic follow-up) with overlapping DESs and BMSs, there was a higher incidence of major adverse events (3 repeat percutaneous coronary interventions and 1 death, 50% adverse event rate) and worse in-segment binary restenosis rate compared with patients treated with homogenous or heterogenous DESs (p = 0.02 and 0.012, respectively). Late lumen loss at the site of stent overlap showed significant differences according to type of overlapped stent (1.00 +/- 0.76 mm in DES-BMS overlap, 0.32 +/- 0.55 mm in PES-PES overlap, 0.13 +/- 0.11 in SES-PES overlap, and 0.08 +/- 0.10 mm in SES-SES overlap, p = 0.005). In conclusion, the present study suggests that overlap of DESs and BMSs should be avoided because the antirestenotic effect of DESs is skewed by contiguous BMS implantation. Overlap between SESs and PESs in this very preliminary report was associated with no specific adverse event.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Materiais Revestidos Biocompatíveis , Doença das Coronárias/terapia , Metais , Stents , Idoso , Antineoplásicos Fitogênicos/farmacologia , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Paclitaxel/farmacologia , Estudos Prospectivos , Desenho de Prótese , Sirolimo/farmacologia , Resultado do TratamentoRESUMO
BACKGROUND: The purpose of this research was to investigate the in vivo morphofunctional changes induced in the radial artery (RA) by its use as coronary artery bypass conduit by comparing the morphological features and vasoreactivity of the native RA versus the coronary RA graft in the same patient. METHODS AND RESULTS: Ten years after surgery, 10 patients were submitted to intravascular ultrasound examination of the RA graft of the controlateral (in situ) RA and of the internal thoracic artery (ITA) graft and to vasoactive challenges with acetylcholine and serotonin. Quantitative angiographic assessment showed that the mean diameter of the RA coronary grafts was significantly larger than that of the in situ RA and of the ITA (2.89+/-0.40 mm RA grafts, 2.14+/-0.52 mm in situ RA, 2.25+/-0.53 mm ITA grafts; P<0.001). The in situ RA demonstrated a typical muscular architecture, whereas RA coronary grafts showed a clear reduction of the thickness of the medial layer and had a less well-defined muscular component of the media with interposition of elastic tissue. Serotonin endovascular infusion elicited a strong spastic reaction in in situ RAs; the same challenge induced only moderate constriction in RA and ITA coronary grafts. CONCLUSIONS: Implantation in the coronary circulation leads to major anatomic and vasoreactive modifications of the RAs that tend to lose the morphofunctional features of a muscular conduit and assume those of an elastomuscular artery, such as the ITA.
Assuntos
Ponte de Artéria Coronária , Tecido Elástico/ultraestrutura , Músculo Liso Vascular/ultraestrutura , Artéria Radial/transplante , Acetilcolina , Prótese Vascular , Angiografia Coronária , Tecido Elástico/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Anastomose de Artéria Torácica Interna-Coronária , Dinitrato de Isossorbida/farmacologia , Masculino , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/efeitos dos fármacos , Artéria Torácica Interna/ultraestrutura , Pessoa de Meia-Idade , Músculo Liso Vascular/diagnóstico por imagem , Artéria Radial/diagnóstico por imagem , Artéria Radial/efeitos dos fármacos , Artéria Radial/ultraestrutura , Serotonina , Transplante Heterotópico , Ultrassonografia de Intervenção , Vasoconstritores/farmacologia , Vasodilatadores/farmacologiaRESUMO
BACKGROUND: In patients who develop in-stent restenosis, successful revascularization can be difficult to achieve using percutaneous methods. This study was designed to verify the surgical results in this setting and to evaluate the potential beneficial role of arterial bypass conduits. METHODS AND RESULTS: Sixty consecutive coronary artery bypass patients with previous in-stent restenosis and 60 control cases were randomly assigned to receive an arterial conduit (either right internal thoracic or radial artery; study group) or a great saphenous vein graft (control group) on the first obtuse marginal artery to complete the surgical revascularization procedure. At a mean follow-up of 52+/-11 months, patients were reassessed clinically and by angiography. Freedom from clinical and instrumental evidence of ischemia recurrence was found in 19 of 60 subjects in the study group versus 45 of 60 in the control series (P=0.01). The results of the arterial grafts were excellent in both the study and control groups (right internal thoracic artery patency rate, 19 of 20 for both, and radial artery patency rate, 20 of 20 versus 19 of 20; P=0.99). Saphenous vein grafts showed lower patency rate than arterial grafts in both series and had extremely high failure rate in the study group (patency rate, 10 of 20 in the study group versus 18 of 20 in the control group; P=0.001). Use of venous graft was an independent predictor of failure in the study group, whereas hypercholesterolemia was associated with graft failure in both series. CONCLUSIONS: Venous grafts have an high incidence of failure among cases who previously developed in-stent restenosis, whereas the use of arterial conduits can improve the angiographic and clinical results. Arterial grafts should probably be the first surgical choice in this patient population.
Assuntos
Ponte de Artéria Coronária/métodos , Reestenose Coronária/cirurgia , Oclusão de Enxerto Vascular/cirurgia , Artéria Radial/transplante , Reoperação/métodos , Veia Safena/transplante , Stents , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Ponte de Artéria Coronária/estatística & dados numéricos , Estenose Coronária/terapia , Feminino , Seguimentos , Humanos , Anastomose de Artéria Torácica Interna-Coronária/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Transplante Heterotópico , Resultado do Tratamento , Grau de Desobstrução VascularRESUMO
OBJECTIVES: The aim of this study was to evaluate the use of a new manual thrombus-aspirating device in unselected patients with ST-segment elevation acute myocardial infarction (STEMI) undergoing urgent percutaneous coronary intervention (PCI). BACKGROUND: Failure to achieve myocardial reperfusion often occurs during PCI in patients with STEMI. The use of thrombus-aspirating devices might improve myocardial reperfusion by reducing distal embolization. METHODS: We prospectively randomized before coronary angiography 100 consecutive patients with STEMI to either standard PCI or PCI with manual thrombus-aspiration. Primary end points of the study were post-procedural rates of myocardial blush grade (MBG) > or =2 and ST-segment resolution (STR) > or =70%. Analyses were planned by intention to treat. RESULTS: Ninety-nine patients entered the analyses. The rates of post-procedural MBG > or =2 and STR > or =70% were, respectively, 68.0% and 44.9% in the thrombus-aspiration group compared with 58.0% and 36.7% in the standard PCI group: odds ratio (OR) 2.6 (95% confidence interval [CI] 1.2 to 5.9), p = 0.020, and 2.4 (95% CI 1.1 to 5.3), p = 0.034, respectively. Moreover, the rate of patients achieving both the angiographic and electrocardiographic (ECG) criteria of optimal reperfusion was significantly higher in the thrombus-aspiration group compared with standard PCI: 46.0% versus 24.5%, OR 2.6 (95% CI 1.1 to 6.2), p = 0.025. In multivariate analysis, randomization to thrombus-aspiration was a significant independent predictor of achievement of MBG > or =2 and STR > or =70% (p = 0.013). CONCLUSIONS: This prospective randomized study shows that manual thrombus-aspiration in unselected patients with STEMI undergoing primary or rescue PCI is clinically feasible and results in better angiographic and ECG myocardial reperfusion rates compared with those achieved by standard PCI.
Assuntos
Angioplastia Coronária com Balão , Cateterismo Cardíaco/instrumentação , Trombose Coronária/terapia , Infarto do Miocárdio/terapia , Sucção/instrumentação , Angiografia Coronária , Eletrocardiografia , Embolia/prevenção & controle , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Reperfusão Miocárdica , Estudos Prospectivos , Fatores de RiscoRESUMO
BACKGROUND: Platelet reactivity is increased by exercise in patients with obstructive coronary artery disease (CAD) but not in patients with syndrome X. In this study, we prospectively investigated whether the platelet response to exercise might help distinguish, among patients with angina, those with obstructive CAD from those with normal coronary arteries (NCAs). METHODS AND RESULTS: Venous blood samples were collected before and 5 minutes after exercise from 194 consecutive patients with stable angina. Platelet reactivity was measured by the platelet function analyzer (PFA)-100 system as the time for flowing whole blood to occlude a collagen-adenosine diphosphate ring (closure time). Coronary angiography showed CAD in 163 patients (84%) and NCA in 31 patients (16%). Baseline closure time was shorter in NCA patients (78.0+/-16 versus 95.5+/-23 seconds, P<0.0001). With exercise, closure time decreased in CAD patients (-15.5 seconds; 95% confidence limits [CL], -13.0 to -18.0 seconds; P<0.0001), but increased in NCA patients (12.5 seconds; 95% CL, 7.4 to 17.7 seconds; P=0.0004). An increase in closure time with exercise > or =10 seconds had 100% specificity and positive predictive value for NCAs. Similarly, a decrease > or =10 seconds had 100% specificity and positive predictive value for CAD. A closure time change (increase or decrease) > or =10 seconds allowed a correct classification of 55% of all patients. CONCLUSIONS: Among patients with stable angina, the response of platelet reactivity to exercise was predictive of normal or stenosed coronary arteries at angiography. Specifically, an increase in closure time with exercise > or =10 seconds was invariably associated with the presence of NCA.
Assuntos
Angina Pectoris/diagnóstico por imagem , Angina Pectoris/diagnóstico , Angiografia Coronária , Teste de Esforço , Ativação Plaquetária , Estenose Coronária/diagnóstico , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , SíndromeRESUMO
BACKGROUND: No information is available on the long-term results of radial artery (RA) grafts used as coronary artery bypass conduits. METHODS AND RESULTS: In this report, we describe the long-term (105+/-9 months) angiographic results of a series of 90 consecutive patients in whom the RA was used as a coronary artery bypass conduit directly anastomosed to the ascending aorta. The long-term patency and perfect patency rates of the RA were 91.6% and 88%, respectively, versus 97.5% and 96.3% for internal thoracic artery grafts. The severity of stenosis of the target vessel clearly influenced long-term RA patency, whereas location of the target vessel and long-term use of calcium channel blockers did not influence angiographic results. Preserved endothelial function and absence of flow-limiting, fibrous, intimal hyperplasia were also documented. CONCLUSIONS: Ten years after surgery, RA grafts have excellent patency and perfect patency rates. Appropriate surgical technique and correct indication are the key factors for long-term RA patency.
Assuntos
Ponte de Artéria Coronária , Artéria Radial/transplante , Bloqueadores dos Canais de Cálcio/uso terapêutico , Angiografia Coronária , Doença das Coronárias/diagnóstico , Doença das Coronárias/tratamento farmacológico , Doença das Coronárias/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento , UltrassonografiaRESUMO
Gadolinium chelates have been recently proposed and preliminarily tested as contrast agents for diagnostic and interventional angiography in alternative to iodinated media. However, in most studies low-osmolarity agents were employed and digital subtraction was required for satisfactory images. In this article, we report for the first time in the literature two cases of successful percutaneous renal artery stenting in which gadobutrol, a high-osmolar (1 mmol/ml) gadolinium chelate, was employed as contrast agent because of chronic renal failure and substantial risk for iodinated contrast-associated nephrotoxicity. In both patients gadobutrol yielded high-quality images without digital subtraction and was well tolerated with no ensuing renal dysfunction.
Assuntos
Angiografia Digital/métodos , Implante de Prótese Vascular/instrumentação , Falência Renal Crônica , Compostos Organometálicos , Artéria Renal/cirurgia , Stents , Idoso , Seguimentos , Humanos , Falência Renal Crônica/diagnóstico por imagem , Falência Renal Crônica/cirurgia , Masculino , Pessoa de Meia-Idade , Concentração Osmolar , Artéria Renal/diagnóstico por imagem , SegurançaRESUMO
The buddy wire technique, i.e. the use of a second 0.014 inch guide wire placed alongside the one employed to advance balloons and stents inside the coronary artery during percutaneous coronary intervention (PCI), may help in a series of procedural challenges during PCI. Indeed, by improving both the stability of the guiding catheter and the support for balloon and stent, a buddy wire use is sometimes the simplest way to accomplish a successful procedure. In this paper, we discuss technical aspects of some specific circumstances frequently encountered during PCI, in which a buddy wire may be helpful. These include: 1) The reduction of balloon slippage during angioplasty for in-stent restenosis; 2) insufficient back-up of the guiding catheter; 3) stenting of lesions located in vessels with proximal tortuosities/angulations; 4) stenting of lesions distally located in the vessel; 5) facilitation in the positioning of distal protection devices; 6) stenting of a lesion distally located from a previously implanted stent or from a coronary segment with both calcification and sharp bend; 7) PCI on coronary arteries with anomalous origin. Because of its simplicity, low cost, and availability, the use of a buddy wire should be considered when dealing with the aforementioned conditions during PCI procedures.
Assuntos
Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Estenose Coronária/patologia , HumanosRESUMO
AIMS: The aim of this study was to assess the feasibility of unprotected non-ostial left main (LM) imaging by frequency domain optical coherence tomography (FD-OCT). METHODS AND RESULTS: We conducted a retrospective analysis of OCT studies performed to image lesions located in the non-ostial LM. OCT studies were analysed off-line to detect the number of artefact frames in the different LM/bifurcation segments. OCT cross-sectional images were used to assess area measures. OCT longitudinal reconstructions were used to obtain the LM length. Standard quantitative coronary angiography (QCA) was used as the reference methodology. A total of 54 patients with non-ostial LM disease entered the study. The mean number of LM artefact frames was 8±10, corresponding to 19% of the total number of LM frames analysed. The percentages of artefact frames differed significantly according to the segment analysed: 43.3% proximal LM, 11.4% mid LM and 2.1% distal LM, 2.0% ostial left anterior descending artery and 0% ostial left circumflex artery (p<0.0001). All LM OCT measurements were significantly correlated with QCA measurements. CONCLUSIONS: The results of the present study show that FD-OCT assessment of non-ostial LM disease is feasible and may provide high-quality imaging. OCT assessment of distal LM is more efficient than that of the proximal LM segment.
Assuntos
Angiografia Coronária , Doença das Coronárias/patologia , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Tomografia de Coerência Óptica , Idoso , Artefatos , Angiografia Coronária/métodos , Doença das Coronárias/cirurgia , Estudos Transversais , Humanos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodosRESUMO
Although direct stenting (DS) is increasingly used in clinical practice instead of stent implantation after predilatation (conventional stenting [CS]), its impact has not been scientifically proved. We therefore performed, using Mantel-Haenszel analysis, a meta-analysis of the published randomized studies comparing DS with CS. Furthermore, all the key procedural data were systematically sought out and pooled. Ten trials (2,650 coronary lesions, 2,576 patients) were identified and entered into the analysis. Adopted angiographic exclusion criteria were homogeneous. DS, compared with CS, was found to have a similar success rate (98.7% vs 98.9%) and no specific complications. Across the studies, the mean rate of crossover to predilatation in the DS arm was 5.9%. Overall, DS was associated with a 17% procedural time (95% confidence interval [CI] 14% to 20%), a 18% fluoroscopic time (95% CI 15% to 21%), a 11% contrast volume (95% CI 9% to 14%), and a 22% cost reduction (95% CI 16% to 28%). In the early postintervention period, DS was associated with a trend toward reduction of each of the major adverse events (MACEs) and with a significant reduction of myocardial infarction (MI) + death (odds ratio [OR] 0.57, 95% CI 0.35 to 0.95). However, at 6 months, the OR (95% CI) for death, MI, target lesion revascularization, and MACEs were 0.47 (0.19 to 1.27), 0.72 (0.45 to 1.25), 1.07 (0.77 to 1.46), and 0.82 (0.63 to 1.08), respectively. In the subgroup of studies providing quantitative angiographic data, all the parameters were found to be similar between the CS and DS groups. In conclusion, the present meta-analysis shows that DS compared with CS, in selected coronary lesions, is safe, optimizes equipment use, and may enhance the early results of coronary interventions while warranting similar late clinical outcomes.
Assuntos
Stents , Implante de Prótese Vascular/economia , Angiografia Coronária , Doença das Coronárias/complicações , Doença das Coronárias/economia , Doença das Coronárias/cirurgia , Custos e Análise de Custo/economia , Estudos Cross-Over , Seguimentos , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/economia , Complicações Pós-Operatórias/etiologia , Ensaios Clínicos Controlados Aleatórios como Assunto , Stents/economia , Fatores de Tempo , Resultado do TratamentoRESUMO
We report a complex case of percutaneous intervention on a right coronary artery with calcific stenoses and a large coronary aneurysm with long longitudinal diameter, which was successfully performed using a polytetrafluoroethylene-covered self-expandable stent (Symbiot; Boston Scientific; Natick, MA). The use of this new device may enhance the anatomic indications for percutaneous interventions on coronary aneurysms.
Assuntos
Aneurisma Coronário/terapia , Stents , Idoso , Humanos , Masculino , Politetrafluoretileno , Desenho de PróteseRESUMO
BACKGROUND: No data are available on the early vasoreactive profile of skeletonized internal thoracic artery grafts. METHODS: Fifteen patients undergoing primary isolated coronary artery bypass grafting were randomly assigned to receive a skeletonized or pedicled internal thoracic artery graft. On the second postoperative day all patients were subjected to follow-up angiography and endovascular infusion of serotonin, acetylcholine, and isosorbide dinitrate. RESULTS: Internal thoracic artery grafts were widely patent in all cases. Mean diameters of the internal thoracic artery were 1.95 +/- 0.17 mm in the pedicled group and 2.26 +/- 0.40 mm in the skeletonized group. After serotonin challenge, mean internal thoracic artery diameters were reduced to 1.44 +/- 0.34 mm and 1.64 +/- 0.14 mm, respectively; acetylcholine challenge lead to a moderate degree of vasoconstriction (1.55 +/- 0.59 mm in the pedicled group and 1.84 +/- 0.15 mm in the skeletonized group). No statistically significant difference was evident between the two groups at any step. CONCLUSION: Skeletonization does not affect the early vasoreactive profile of internal thoracic artery grafts used for surgical myocardial revascularization.
Assuntos
Dissecação/métodos , Anastomose de Artéria Torácica Interna-Coronária/métodos , Retalhos Cirúrgicos , Artérias Torácicas/fisiopatologia , Artérias Torácicas/transplante , Coleta de Tecidos e Órgãos/métodos , Vasoconstrição , Vasodilatação , Acetilcolina/farmacologia , Idoso , Angiografia Coronária , Dissecação/efeitos adversos , Feminino , Humanos , Dinitrato de Isossorbida/farmacologia , Masculino , Pessoa de Meia-Idade , Serotonina/farmacologia , Artérias Torácicas/diagnóstico por imagem , Artérias Torácicas/efeitos dos fármacos , Coleta de Tecidos e Órgãos/efeitos adversos , Resultado do Tratamento , Grau de Desobstrução Vascular , Vasoconstrição/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos , Vasodilatadores/farmacologiaRESUMO
We report the case of a 60-year-old man with a history of recurrent transient ischemic attacks, effort syncope, cyanosis, erythrocytosis and a systolic murmur. Echocardiography and catheterization showed severe pulmonary stenosis and a patent foramen ovale with a right-to-left shunt. The patient was submitted to combined percutaneous pulmonary valvuloplasty and patent foramen ovale closure using the Amplatzer device.