Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 451
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Comput Assist Tomogr ; 48(3): 388-393, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38110294

RESUMO

OBJECTIVE: The aim of the study is to assess the correlation between artificial intelligence (AI)-based low attenuation volume percentage (LAV%) with forced expiratory volume in the first second to forced vital capacity (FEV1/FVC) and visual emphysema grades in routine chest computed tomography (CT). Furthermore, optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or moderate to more extensive visual emphysema grades were calculated. METHODS: In a retrospective study of 298 consecutive patients who underwent routine chest CT and spirometry examinations, LAV% was quantified using an AI-based software with a threshold < -950 HU. The FEV1/FVC was derived from spirometry, with FEV1/FVC < 70% indicating airway obstruction. The mean time interval of CT from spirometry was 3.87 ± 4.78 days. Severity of emphysema was visually graded by an experienced chest radiologist using an established 5-grade ordinal scale (Fleischner Society classification system). Spearman correlation coefficient between LAV% and FEV1/FVC was calculated. Receiver operating characteristic determined the optimal LAV% cutoff values for predicting a FEV1/FVC < 70% or a visual emphysema grade of moderate or higher (Fleischner grade 3-5). RESULTS: Significant correlation between LAV% and FEV1/FVC was found (ϱ = -0.477, P < 0.001). Increasing LAV% corresponded to higher visual emphysema grades. For patients with absent visual emphysema, mean LAV% was 2.98 ± 3.30, for patients with trace emphysema 3.22 ± 2.75, for patients with mild emphysema 3.90 ± 3.33, for patients with moderate emphysema 6.41 ± 3.46, for patients with confluent emphysema 9.02 ± 5.45, and for patients with destructive emphysema 16.90 ± 8.19. Optimal LAV% cutoff value for predicting a FEV1/FVC < 70 was 6.1 (area under the curve = 0.764, sensitivity = 0.773, specificity = 0.665), while for predicting a visual emphysema grade of moderate or higher, it was 4.7 (area under the curve = 0.802, sensitivity = 0.766, specificity = 0.742). Furthermore, correlation between visual emphysema grading and FEV1/FVC was found. In patients with FEV1/FVC < 70% a high proportion of subjects had emphysema grade 3 (moderate) or higher, whereas in patients with FEV1/FVC ≥ 70%, a larger proportion had emphysema grade 3 (moderate) or lower. The sensitivity for visual emphysema grading predicting a FEV1/FVC < 70% was 56.3% with an optimal cutoff point at a visual grade of 4 (confluent), demonstrating a lower sensitivity compared with LAV% (77.3%). CONCLUSIONS: A significant correlation between AI-based LAV% and FEV1/FVC as well as visual CT emphysema grades can be found in routine chest CT suggesting that AI-based LAV% measurement might be integrated as an add-on functional parameter in the evaluation of chest CT in the future.


Assuntos
Inteligência Artificial , Enfisema Pulmonar , Espirometria , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/fisiopatologia , Idoso , Volume Expiratório Forçado , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Radiografia Torácica/métodos , Índice de Gravidade de Doença , Adulto
2.
Acta Radiol ; 65(1): 145-151, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37743550

RESUMO

BACKGROUND: Vascular malformations are rare diseases that should be treated in dedicated vascular anomaly centers (VAC). There is only a small amount of data on the diagnostic and therapeutic handling of these patients, before they are referred to a VAC. PURPOSE: To demonstrate the disease-specific patient characteristics in a German VAC, which are required to determine diagnostic and therapeutic steps. MATERIAL AND METHODS: In a retrospective study, all patients who were treated in the VAC from April 2014 until August 2021 were identified. In total, 593 patients were included in this study. RESULTS: Almost all patients had previously consulted a physician (591/593, 99.7%). A mean of two different physicians had been consulted (range 0-10). Patients with more complex, syndromal vascular malformations had significantly more previous appointments (P = 0.0018). In only 44% (261/593) of patients, the referral diagnosis was made correctly. Most patients had been previously treated for their vascular anomaly: pharmacotherapy (n = 130; 21.9%), compression garments (n = 141; 23.8%), surgical resection (n = 80; 17.3%) and sclerotherapy (n = 68; 11.5%). Fifty-two patients who had been falsely diagnosed had also received therapy prior to their referral to the VAC (8.8%). Most patients received an ultrasound examination in the VAC (n = 464; 78.2%). Most frequently, compression therapy was prescribed (n = 256; 43.2%), followed by sclerotherapy (n = 175, 29.5%) and pharmacotherapy (n = 55; 9.3%). CONCLUSION: Patients suffering from vascular anomalies often go through a complicated scheduling with numerous outpatient appointments and have a high risk of misdiagnosis and mistreatment prolonging the medical condition. Therefore, patients with vascular anomalies should be treated in a dedicated vascular anomaly center.


Assuntos
Malformações Vasculares , Humanos , Estudos Retrospectivos , Malformações Vasculares/diagnóstico por imagem , Malformações Vasculares/terapia , Escleroterapia , Ultrassonografia
3.
Pediatr Radiol ; 54(1): 58-67, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37982901

RESUMO

BACKGROUND: Though neoadjuvant chemotherapy has been widely used in the treatment of hepatoblastoma, there still lacks an effective way to predict its effect. OBJECTIVE: To characterize hepatoblastoma based on radiomics image features and identify radiomics-based lesion phenotypes by unsupervised machine learning, intended to build a classifier to predict the response to neoadjuvant chemotherapy. MATERIALS AND METHODS: In this retrospective study, we segmented the arterial phase images of 137 cases of pediatric hepatoblastoma and extracted the radiomics features using PyRadiomics. Then unsupervised k-means clustering was applied to cluster the tumors, whose result was verified by t-distributed stochastic neighbor embedding (t-SNE). The least absolute shrinkage and selection operator (LASSO) regression was used for feature selection, and the clusters were visually analyzed by radiologists. The correlations between the clusters, clinical and pathological parameters, and qualitative radiological features were analyzed. RESULTS: Hepatoblastoma was clustered into three phenotypes (homogenous type, heterogenous type, and nodulated type) based on radiomics features. The clustering results had a high correlation with response to neoadjuvant chemotherapy (P=0.02). The epithelial ratio and cystic components in radiological features were also associated with the clusters (P=0.029 and 0.008, respectively). CONCLUSIONS: This radiomics-based cluster system may have the potential to facilitate the precise treatment of hepatoblastoma. In addition, this study further demonstrated the feasibility of using unsupervised machine learning in a disease without a proper imaging classification system.


Assuntos
Hepatoblastoma , Neoplasias Hepáticas , Criança , Humanos , Terapia Neoadjuvante , Hepatoblastoma/diagnóstico por imagem , Hepatoblastoma/tratamento farmacológico , Radiômica , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Fenótipo , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/tratamento farmacológico
4.
Eur Radiol ; 33(11): 7840-7848, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37338555

RESUMO

OBJECTIVES: To investigate the effect of a device-assisted suction against resistance Mueller maneuver (MM) on transient interruption of contrast (TIC) in the aorta and pulmonary trunk (PT) on computed tomography pulmonary angiogram (CTPA). METHODS: In this prospective single-center study, 150 patients with suspected pulmonary artery embolism were assigned randomly with two different breathing maneuvers (Mueller maneuver (MM) or standard end-inspiratory breath-hold command (SBC)) during routine CTPA. The MM was performed using a patented prototype (Contrast Booster™) which allows both the patient by means of visual feedback and the medical staff in the CT scanning room to monitor whether the patient is sucking sufficiently or not. Mean Hounsfield attenuation in descending aorta and PT was measured and compared. RESULTS: Overall, patients with MM showed an attenuation of 338.24 HU in the pulmonary trunk, compared to 313.71 HU in SBC (p = 0.157). In the aorta, the values for MM were lower compared to SBC (134.42 HU vs. 177.83 HU, p = 0.001). The TP-aortic ratio was significantly higher in the MM group at 3.86 compared to the SBC group at 2.26, p = 0.001. TIC phenomenon was absent in the MM group, whereas it was present in 9 patients (12.3%) in the SBC group (p = 0.005). Overall contrast was better on all levels for MM (p < 0.001). The presence of breathing artifacts was higher in the MM group (48.1% vs. 30.1%, p = 0.038), without clinical consequence. CONCLUSIONS: Performing the MM with the application of the prototype is an effective way of preventing the TIC phenomenon during i.v. contrast-enhanced CTPA scanning compared to the standard end-inspiratory breathing command. CLINICAL RELEVANCE: Compared to standard end-inspiratory breathing command, the device-assisted Mueller maneuver (MM) improves contrast enhancement and prevents the transient interruption of contrast (TIC) phenomenon in CTPA. Therefore, it may offer optimized diagnostic workup and timely treatment for patients with pulmonary embolism. KEY POINTS: • Transient interruption of contrast (TIC) may impair image quality in CTPA. • Mueller Maneuver using a device prototype could lower the rate of TIC. • Device application in clinical routine may increase diagnostic accuracy.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Sucção , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos , Artéria Pulmonar/diagnóstico por imagem , Embolia Pulmonar/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Meios de Contraste
5.
Eur Radiol ; 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37940710

RESUMO

OBJECTIVES: To investigate the feasibility of non-contrast-enhanced functional lung imaging in 2-year-old children after congenital diaphragmatic hernia (CDH) repair. METHODS: Fifteen patients after CDH repair were examined using non-contrast-enhanced dynamic magnetic resonance imaging (MRI). For imaging two protocols were used during free-breathing: Protocol A with high temporal resolution and Protocol B with high spatial resolution. The dynamic images were then analysed through a recently developed post-processing method called dynamic mode decomposition (DMD) to obtain ventilation and perfusion maps. The ventilation ratios (VRatio) and perfusion ratios (QRatio) of ipsilateral to contralateral lung were compared to evaluate functional differences. Lastly, DMD MRI-based perfusion results were compared with perfusion parameters obtained using dynamic contrast-enhanced (DCE) MRI to assess agreement between methods. RESULTS: Both imaging protocols successfully generated pulmonary ventilation (V) and perfusion (Q) maps in all patients. Overall, the VRatio and QRatio values were 0.84 ± 0.19 and 0.70 ± 0.24 for Protocol A, and 0.88 ± 0.18 and 0.72 ± 0.23 for Protocol B, indicating reduced ventilation ([Formula: see text]) and perfusion ([Formula: see text]) on the ipsilateral side. Moreover, there is a very strong positive correlation ([Formula: see text]) and close agreement between DMD MRI-based perfusion values and DCE MRI-based perfusion parameters. CONCLUSIONS: DMD MRI can obtain pulmonary functional information in 2-year-old CDH patients. The results obtained with DMD MRI correlate with DCE MRI, without the need for ionising radiation or exposure to contrast agents. While further studies with larger cohorts are warranted, DMD MRI is a promising option for functional lung imaging in CDH patients. CLINICAL RELEVANCE STATEMENT: We demonstrate that pulmonary ventilation and perfusion information can be obtained in 2-year-old patients after CDH repair, without the need for ionising radiation or contrast agents by utilising non-contrast-enhanced MRI acquisitions together with dynamic mode decomposition analysis. KEY POINTS: • Non-contrast-enhanced functional MR imaging is a promising option for functional lung imaging in 2-year-old children after congenital diaphragmatic hernia. • DMD MRI can generate pulmonary ventilation and perfusion maps from free-breathing dynamic acquisitions without the need for ionising radiation or contrast agents. • Lung perfusion parameters obtained with DMD MRI correlate with perfusion parameters obtained using dynamic contrast-enhanced MRI.

6.
Eur Radiol ; 33(7): 4905-4914, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36809435

RESUMO

OBJECTIVES: Radiomics image data analysis offers promising approaches in research but has not been implemented in clinical practice yet, partly due to the instability of many parameters. The aim of this study is to evaluate the stability of radiomics analysis on phantom scans with photon-counting detector CT (PCCT). METHODS: Photon-counting CT scans of organic phantoms consisting of 4 apples, kiwis, limes, and onions each were performed at 10 mAs, 50 mAs, and 100 mAs with 120-kV tube current. The phantoms were segmented semi-automatically and original radiomics parameters were extracted. This was followed by statistical analysis including concordance correlation coefficients (CCC), intraclass correlation coefficients (ICC), as well as random forest (RF) analysis, and cluster analysis to determine the stable and important parameters. RESULTS: Seventy-three of the 104 (70%) extracted features showed excellent stability with a CCC value > 0.9 when compared in a test and retest analysis, and 68 features (65.4%) were stable compared to the original in a rescan after repositioning. Between the test scans with different mAs values, 78 (75%) features were rated with excellent stability. Eight radiomics features were identified that had an ICC value greater than 0.75 in at least 3 of 4 groups when comparing the different phantoms in a phantom group. In addition, the RF analysis identified many features that are important for distinguishing the phantom groups. CONCLUSION: Radiomics analysis using PCCT data provides high feature stability on organic phantoms, which may facilitate the implementation of radiomics analysis likewise in clinical routine. KEY POINTS: • Radiomics analysis using photon-counting computed tomography provides high feature stability. • Photon-counting computed tomography may pave the way for implementation of radiomics analysis in clinical routine.


Assuntos
Algoritmo Florestas Aleatórias , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Fótons
7.
Eur Radiol ; 33(8): 5578-5586, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36890304

RESUMO

OBJECTIVES: Computed tomography (CT) is employed to evaluate surgical outcome after spinal interventions. Here, we investigate the potential of multispectral photon-counting computed tomography (PC-CT) on image quality, diagnostic confidence, and radiation dose compared to an energy-integrating CT (EID-CT). METHODS: In this prospective study, 32 patients underwent PC-CT of the spine. Data was reconstructed in two ways: (1) standard bone kernel with 65-keV (PC-CTstd) and (2) 130-keV monoenergetic images (PC-CT130 keV). Prior EID-CT was available for 17 patients; for the remaining 15, an age-, sex-, and body mass index-matched EID-CT cohort was identified. Image quality (5-point Likert scales on overall, sharpness, artifacts, noise, diagnostic confidence) of PC-CTstd and EID-CT was assessed by four radiologists independently. If metallic implants were present (n = 10), PC-CTstd and PC-CT130 keV images were again assessed by 5-point Likert scales by the same radiologists. Hounsfield units (HU) were measured within metallic artifact and compared between PC-CTstd and PC-CT130 keV. Finally, the radiation dose (CTDIvol) was evaluated. RESULTS: Sharpness was rated significantly higher (p = 0.009) and noise significantly lower (p < 0.001) in PC-CTstd vs. EID-CT. In the subset of patients with metallic implants, reading scores for PC-CT130 keV revealed superior ratings vs. PC-CTstd for image quality, artifacts, noise, and diagnostic confidence (all p < 0.001) accompanied by a significant increase of HU values within the artifact (p < 0.001). Radiation dose was significantly lower for PC-CT vs. EID-CT (mean CTDIvol: 8.83 vs. 15.7 mGy; p < 0.001). CONCLUSIONS: PC-CT of the spine with high-kiloelectronvolt reconstructions provides sharper images, higher diagnostic confidence, and lower radiation dose in patients with metallic implants. KEY POINTS: • Compared to energy-integrating CT, photon-counting CT of the spine had significantly higher sharpness and lower image noise while radiation dose was reduced by 45%. • In patients with metallic implants, virtual monochromatic photon-counting images at 130 keV were superior to standard reconstruction at 65 keV in terms of image quality, artifacts, noise, and diagnostic confidence.


Assuntos
Doenças da Coluna Vertebral , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fótons , Estudos Prospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/diagnóstico por imagem
8.
BMC Med Imaging ; 23(1): 97, 2023 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-37495950

RESUMO

BACKGROUND: Cardiovascular diseases remain the world's primary cause of death. The identification and treatment of patients at risk of cardiovascular events thus are as important as ever. Adipose tissue is a classic risk factor for cardiovascular diseases, has been linked to systemic inflammation, and is suspected to contribute to vascular calcification. To further investigate this issue, the use of texture analysis of adipose tissue using radiomics features could prove a feasible option. METHODS: In this retrospective single-center study, 55 patients (mean age 56, 34 male, 21 female) were scanned on a first-generation photon-counting CT. On axial unenhanced images, periaortic adipose tissue surrounding the thoracic descending aorta was segmented manually. For feature extraction, patients were divided into three groups, depending on coronary artery calcification (Agatston Score 0, Agatston Score 1-99, Agatston Score ≥ 100). 106 features were extracted using pyradiomics. R statistics was used for statistical analysis, calculating mean and standard deviation with Pearson correlation coefficient for feature correlation. Random Forest classification was carried out for feature selection and Boxplots and heatmaps were used for visualization. Additionally, monovariable logistic regression predicting an Agatston Score > 0 was performed, selected features were tested for multicollinearity and a 10-fold cross-validation investigated the stability of the leading feature. RESULTS: Two higher-order radiomics features, namely "glcm_ClusterProminence" and "glcm_ClusterTendency" were found to differ between patients without coronary artery calcification and those with coronary artery calcification (Agatston Score ≥ 100) through Random Forest classification. As the leading differentiating feature "glcm_ClusterProminence" was identified. CONCLUSION: Changes in periaortic adipose tissue texture seem to correlate with coronary artery calcium score, supporting a possible influence of inflammatory or fibrotic activity in perivascular adipose tissue. Radiomics features may potentially aid as corresponding biomarkers in the future.


Assuntos
Doenças Cardiovasculares , Doença da Artéria Coronariana , Humanos , Masculino , Feminino , Cálcio , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem
9.
Acta Radiol ; 64(6): 2111-2117, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37046385

RESUMO

BACKGROUND: Low attenuation volume percentage (LAV%) has been identified as a quantitative imaging biomarker for emphysema with good correlation with spirometry. The influence of intravenous contrast agent on LAV% and its correlation with spirometry is not well known. PURPOSE: To evaluate the influence of intravenous contrast agent on artificial intelligence (AI)-based LAV% in correlation with spirometric Tiffeneau-Pinelli Index (TI). MATERIAL AND METHODS: In a retrospective study, two groups of 47 patients (mean age 68.04 ± 12.64 and 67.89 ± 11.54 years) with either non-enhanced chest computed tomography (CT) or contrast-enhanced CT were compared. Using an AI-based software, LAV% was quantified using a threshold <-950 HU. TI was calculated from spirometry and pathologic airway obstruction was considered with a TI <70. The effect of contrast agent on LAV% and the relationship between TI and LAV% was analyzed. Correlation coefficients between TI and LAV% were compared for both groups. RESULTS: Patients with non-enhanced CT had a mean LAV% of 9.07 ± 7.53. Of them, 22 patients had a TI <70% and 25 patients a TI ≥70%. Patients with contrast-enhanced CT had a mean LAV% of 6.54 ± 4.62. Of them, 20 patients had a TI <70% and 27 patients had a TI ≥70%. Contrast agent did not show a major effect on LAV% (P = 0.099) and the relationship between TI and LAV% (P = 0.88). In both groups, a significant correlation between TI and LAV% was found (ρ = -0.317 for non-enhanced CT; ρ = -0.514 for contrast-enhanced CT). Difference between correlation coefficients was insignificant. CONCLUSION: Our findings suggest that contrast agent does not influence LAV% nor its correlation with TI.


Assuntos
Meios de Contraste , Pulmão , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Inteligência Artificial , Tomografia Computadorizada por Raios X/métodos
10.
Pediatr Radiol ; 53(6): 1057-1062, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36635378

RESUMO

BACKGROUND: With the clinical release of a photon counting detector-based computed tomography (CT) system, the potential benefits of this new technology need to be evaluated clinically. Literature concerning this new generation of detector is sparse, especially in the field of pediatric radiology. Therefore, this study outlines our initial experience with ultra-low dose chest CT imaging on the new photon counting CT system. MATERIALS AND METHODS: A pediatric phantom (1-year old, CIRS ATOM phantom, model 704 [CIRS-computerized imaging reference system, Norfolk, VA]) was scanned at different dose levels and different image quality levels to define a protocol for clinical examinations. Next, 20 consecutive pediatric non-contrast ultra-low dose chest CT examinations were evaluated for radiation dose and diagnostic image quality using a 4-point Likert-scale-1 = excellent, 4 = bad image quality-by two radiologists in a consensus reading. This retrospective analysis was approved by the local research ethics committee. RESULTS: Chest CT examinations performed at ultra-low radiation dose (effective dose 0.19 ± 0.07 mSv; size-specific dose estimate 0.45 ± 0.14 mGy) in pediatric patients ages (2.6 ± 1.8 years) show good to excellent image quality for lung structures (1.4 ± 0.4) and moderate image quality for soft tissue structures (2.8 ± 0.2). CONCLUSION: Pediatric ultra-low dose chest CT examinations are feasible with the new generation photon counting detector-based CT system. The benefits of this technology must be evaluated for pediatric patients from the outset.


Assuntos
Pulmão , Tomografia Computadorizada por Raios X , Humanos , Criança , Lactente , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Fótons , Imagens de Fantasmas
11.
Magn Reson Med ; 88(4): 1764-1774, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35608220

RESUMO

PURPOSE: To introduce phase-cycled balanced SSFP (bSSFP) acquisition as an alternative in Fourier decomposition MRI for improved robustness against field inhomogeneities. METHODS: Series 2D dynamic lung images were acquired in 5 healthy volunteers at 1.5 T and 3 T using bSSFP sequence with multiple RF phase increments and compared with conventional single RF phase increment acquisitions. The approach was evaluated based on functional map homogeneity analysis, while ensuring image and functional map quality by means of SNR and contrast-to-noise ratio analyses. RESULTS: At both field strengths, functional maps obtained with phase-cycled acquisitions displayed improved robustness against local signal losses compared with single-phase acquisitions. The coefficient of variation (mean ± SD, across volunteers) measured in the ventilation maps resulted in 29.7 ± 2.6 at 1.5 T and 37.5 ± 3.1 at 3 T for phase-cycled acquisitions, compared with 39.9 ± 5.2 at 1.5 T and 49.5 ± 3.7 at 3 T for single-phase acquisitions, indicating a significant improvement ( p<0.05$$ p<0.05 $$ ) in ventilation map homogeneity. CONCLUSIONS: Phase-cycled bSSFP acquisitions improve robustness against field inhomogeneity artifacts and significantly improve ventilation map homogeneity at both field strengths. As such, phase-cycled bSSFP may serve as a robust alternative in lung function assessments.


Assuntos
Algoritmos , Artefatos , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tórax
12.
Eur Radiol ; 32(4): 2572-2580, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34741621

RESUMO

OBJECTIVES: To evaluate whether lung perfusion continues to be reduced in 10-year-old children after congenital diaphragmatic hernia (CDH) and whether lung perfusion values correlate with spirometric lung function measurements. METHODS: Fifty-four patients after CDH repair received dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI)-based lung perfusion measurements at the age of 10 years (10.2 ± 1.0 years). Additionally, a control group of 10 children has been examined according to the same protocol. Lung spirometry was additionally available in 43 patients of the CDH group. A comparison of ipsilateral and contralateral parameters was performed. RESULTS: Pulmonary blood flow (PBF) was reduced on the ipsilateral side in CDH patients (60.4 ± 23.8 vs. 93.3 ± 16.09 mL/100 mL/min; p < 0.0001). In comparison to the control group, especially the ratio of ipsilateral to contralateral, PBF was reduced in CDH patients (0.669 ± 0.152 vs. 0.975 ± 0.091; p < 0.0001). There is a positive correlation between ipsilateral pulmonary blood flow, and spirometric forced 1-s volume (r = 0.45; p = 0.0024). CONCLUSIONS: Pulmonary blood flow impairment persists during childhood and correlates with spirometric measurements. Without the need for ionizing radiation, MRI measurements seem promising as follow-up parameters after CDH. KEY POINTS: • Ten-year-old children after congenital diaphragmatic hernia continue to show reduced perfusion of ipsilateral lung. • Lung perfusion values correlate with lung function tests after congenital diaphragmatic hernia.


Assuntos
Hérnias Diafragmáticas Congênitas , Adolescente , Criança , Humanos , Pulmão/patologia , Perfusão , Testes de Função Respiratória , Espirometria
13.
Ann Allergy Asthma Immunol ; 128(3): 314-318, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34637924

RESUMO

BACKGROUND: Patients with systemic mastocytosis (SM) are at increased risk of hypersensitivity reactions (HRs). Although Hymenoptera venoms are the predominant triggers, cases of contrast media-induced HR (CMIHR) have also been reported and prophylactic premedication is often performed. However, data from larger series are limited and differences between indolent and advanced SM have not yet been investigated. OBJECTIVE: To determine the incidence and severity of CMIHR in all subtypes of SM. METHODS: We analyzed 162 adult patients with SM (indolent systemic mastocytosis [ISM], n = 65; advanced systemic mastocytosis [advSM], n = 97). First, the cumulative incidence of CMIHR was retrospectively assessed in the patient's history. Second, at our institution, patients underwent 332 contrast media (CM)-enhanced imaging including 80 computed tomography (CT) scans with iodine-based contrast agent and 252 magnetic resonance imaging (MRI) with a gadolinium-based contrast agent, and tolerance was assessed. RESULTS: Previous CMIHRs to CT (vomiting, n = 1, erythema, n = 1, cardiovascular shock, n = 1), and MRI (dyspnea, n = 1, cardiovascular shock, n = 1) had been reported by 4 out of 162 (2.5%) patients (ISM, n = 3; advSM, n = 1). In contrast, during or after 332 CM-enhanced CT or MRI examinations at our institution, no CMIHRs were reported. Premedication was solely given to 3 patients before CT scans, including 1 with previous CMIHR, who tolerated the imaging well. CONCLUSION: We conclude that: (1) there is a substantial discrepancy between the perception and prevalence of HRs to CM in SM; (2) reactions are scarce in ISM and even rarer in advSM; and (3) in SM patients without previous history of CM hypersensitivity, prophylactic premedication before CM-enhanced CT or MRI is dispensable.


Assuntos
Venenos de Artrópodes , Mastocitose Sistêmica , Mastocitose , Adulto , Meios de Contraste/efeitos adversos , Humanos , Imageamento por Ressonância Magnética , Estudos Retrospectivos
14.
AJR Am J Roentgenol ; 218(4): 659-669, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34668385

RESUMO

BACKGROUND. CT-based criteria for assessing the gastrointestinal stromal tumor (GIST) response to tyrosine kinase inhibitor (TKI) therapy are limited in part because tumor attenuation is influenced by treatment-related changes including hemorrhage and calcification. The iodine concentration may be less impacted by such changes. OBJECTIVE. The purpose of this study was to determine whether the dual-energy CT (DECT) vital iodine tumor burden (TB) allows improved differentiation between treatment responders and nonresponders among patients with metastatic GIST who are undergoing TKI therapy compared with established CT and PET/CT criteria. METHODS. An anthropomorphic phantom with spherical inserts mimicking GIST lesions of varying iodine concentrations and having nonenhancing central necrotic cores underwent DECT to determine a threshold iodine concentration. Forty patients (25 women and 15 men; median age, 57 years) who were treated with TKI for metastatic GIST were retrospectively evaluated. Patients underwent baseline and follow-up DECT and FDG PET/CT. Response assessment was performed using RECIST 1.1, modified Choi (mChoi) criteria, vascular tumor burden (VTB) criteria, DECT vital iodine TB criteria, and European Organization for Research and Treatment of Cancer (EORTC) PET criteria. DECT vital iodine TB criteria used the same percentage changes as RECIST 1.1 response categories. Progression-free survival was compared between responders and nonresponders for each response criterion by use of Cox proportional hazard ratios and Harrell C-indexes (i.e., concordance indexes). RESULTS. The phantom experiment identified a threshold of 0.5 mg/mL to differentiate vital from nonvital tissue. With use of the DECT vital iodine TB, median progression-free survival was significantly different between responders and nonresponders (623 vs 104 days; p < .001).. For nonresponders versus responders, the hazard ratio for disease progression for DECT vital iodine TB was 6.9 versus 7.6 for EORTC PET criteria, 3.3 for VTB criteria, 2.3 for RECIST 1.1, and 2.1 for mChoi criteria. The C-index was 0.74 for EORTC PET criteria, 0.73 for DECT vital iodine TB criteria, 0.67 for VTB criteria, 0.61 for RECIST 1.1, and 0.58 for mChoi criteria. The C-index was significantly greater for DECT vital iodine TB criteria than for RECIST 1.1 (p = .02) and mChoi criteria (p = .002), but it was not different from that for VTB and EORTC PET criteria (p > .05). CONCLUSION. DECT vital iodine TB criteria showed performance comparable to that of EORTC PET criteria and outperformed RECIST 1.1 and mChoi criteria for response assessment of metastatic GIST treated with TKI therapy. CLINICAL IMPACT. DECT vital iodine TB could help guide early management decisions in patients receiving TKI therapy.


Assuntos
Tumores do Estroma Gastrointestinal , Iodo , Segunda Neoplasia Primária , Feminino , Fluordesoxiglucose F18 , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Carga Tumoral
15.
Acta Orthop Belg ; 88(1): 1-9, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35512148

RESUMO

The key element for differentiation between normal anatomical variants and pathological deformities is the prior definition of normal ranges for anthropometric parameters of acetabulum according to each age group. Aim of the present study is to analyze the development of the acetabulum in children/adolescents by accurate anthropometric measurements using 3D-CT scans and determine the variations occurring depending on age, gender and/or side. This retrospective observational study included 85 patients (170 hips) under 15 years of age (0-15) undergoing 1.5mm CT scanning for non-hip related reasons. The measurements were performed by 2 board-certified orthopaedic surgeons. Each year of life represented an age group forming a total of 16 groups. Median number of patients per age group was 12 (range 4-16). The anthropometric parameters included acetabular volume, inclination, version, depth (coronal and axial), width (coronal and axial), Tönnis angle as well as anterior and posterior acetabular sector angles. Mean values, range, standard deviation, p-values, intra- and interrater reliability were calculated. All measurement values correlated significantly with age. Statistically, there was no side or gender related difference. Rapid growth phases were observed at the age of 11-12. The inter- and intrarater reliability was high (range ICC 0.8-0.99, Cronbach alpha 0.86-0.99, Bland-Altman good agreement). The present data provides age- and gender-related normative values as well as growth phases describing acetabular morphology. It should help paediatricians as well as paediatric and orthopaedic surgeons as a tool for early diagnosis of deformity and guidance for possible procedures.


Assuntos
Acetábulo , Tomografia Computadorizada por Raios X , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Adolescente , Criança , Articulação do Quadril/cirurgia , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos
16.
Eur J Nucl Med Mol Imaging ; 48(10): 3268-3276, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33686457

RESUMO

PURPOSE: Rectal cancer is one of the most frequent causes of cancer-related morbidity and mortality in the world. Correct identification of the TNM state in primary staging of rectal cancer has critical implications on patient management. Initial evaluations revealed a high sensitivity and specificity for whole-body PET/MRI in the detection of metastases allowing for metastasis-directed therapy regimens. Nevertheless, its cost-effectiveness compared with that of standard-of-care imaging (SCI) using pelvic MRI + chest and abdominopelvic CT is yet to be investigated. Therefore, the aim of this study was to analyze the cost-effectiveness of whole-body 18F FDG PET/MRI as an alternative imaging method to standard diagnostic workup for initial staging of rectal cancer. METHODS: For estimation of quality-adjusted life years (QALYs) and lifetime costs of diagnostic modalities, a decision model including whole-body 18F FDG PET/MRI with a hepatocyte-specific contrast agent and pelvic MRI + chest and abdominopelvic CT was created based on Markov simulations. For obtaining model input parameters, review of recent literature was performed. Willingness to pay (WTP) was set to $100,000/QALY. Deterministic sensitivity analysis of diagnostic parameters and costs was applied, and probabilistic sensitivity was determined using Monte Carlo modeling. RESULTS: In the base-case scenario, the strategy whole-body 18F FDG PET/MRI resulted in total costs of $52,186 whereas total costs of SCI were at $51,672. Whole-body 18F FDG PET/MRI resulted in an expected effectiveness of 3.542 QALYs versus 3.535 QALYs for SCI. This resulted in an incremental cost-effectiveness ratio of $70,291 per QALY for PET/MRI. Thus, from an economic point of view, whole-body 18F FDG PET/MRI was identified as an adequate diagnostic alternative to SCI with high robustness of results to variation of input parameters. CONCLUSION: Based on the results of the analysis, use of whole-body 18F FDG PET/MRI was identified as a feasible diagnostic strategy for initial staging of rectal cancer from a cost-effectiveness perspective.


Assuntos
Fluordesoxiglucose F18 , Neoplasias Retais , Meios de Contraste , Análise Custo-Benefício , Hepatócitos/patologia , Humanos , Imageamento por Ressonância Magnética , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/patologia , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
17.
Eur Arch Otorhinolaryngol ; 278(7): 2473-2483, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32910225

RESUMO

PURPOSE: Augmented reality improves planning and execution of surgical procedures. The aim of this study was to evaluate the feasibility of a 3D augmented reality hologram in live parotic surgery. Another goal was to develop an accuracy measuring instrument and to determine the accuracy of the system. METHODS: We created a software to build and manually align 2D and 3D augmented reality models generated from MRI data onto the patient during surgery using the HoloLens® 1 (Microsoft Corporation, Redmond, USA). To assess the accuracy of the system, we developed a specific measuring tool applying a standard electromagnetic navigation device (Fiagon GmbH, Hennigsdorf, Germany). RESULTS: The accuracy of our system was measured during real surgical procedures. Training of the experimenters and the use of fiducial markers significantly reduced the accuracy of holographic system (p = 0.0166 and p = 0.0132). Precision of the developed measuring system was very high with a mean error of the basic system of 1.3 mm. Feedback evaluation demonstrated 86% of participants agreed or strongly agreed that the HoloLens will play a role in surgical education. Furthermore, 80% of participants agreed or strongly agreed that the HoloLens is feasible to be introduced in clinical routine and will play a role within surgery in the future. CONCLUSION: The use of fiducial markers and repeated training reduces the positional error between the hologram and the real structures. The developed measuring device under the use of the Fiagon navigation system is suitable to measure accuracies of holographic augmented reality images of the HoloLens.


Assuntos
Realidade Aumentada , Cirurgia Assistida por Computador , Alemanha , Humanos
18.
Radiologe ; 61(2): 203-212, 2021 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-33346870

RESUMO

BACKROUND: SPACE (3D fast spin echo acquisition) sequences require long scan times for three-dimensional assessment of acute injury of the knee joint and are flawed due to geometric blurring. Their implementation into routine diagnostic imaging was not feasible until recently. OBJECTIVES: By comparing conventional MRI (magnetic resonance imaging) sequences to 3D (three-dimensional) sequences, it was investigated whether the compressed sensing (CS) technique is inferior to the established 2D sequences with shorter examination times. MATERIALS AND METHODS: A total of 109 patients (age range 18-50 years) with knee injury were examined by MRI between April 2017 and May 2018. The inter- and intraobserver concordance of two blinded readers were assessed. Consensus was achieved in case of discrepancies. Descriptive analyses of absolute and relative frequency and distribution were tested by Fisher's exact test concerning differences between CS-SPACE and standard proton density fat suppressed imaging. RESULTS: Interoberserver concordance (IC) of conventional sequences before/after consensus amounted to 58.8/68.1% (medial meniscus, MM), 68.8/88.7% (lateral meniscus, LM) 88.9/97.2% (anterior cruciate ligament, ACL), 99/100% (posterior cruciate ligament, PCL), 88.9/97.2% (collateral ligament, CL) and chondral injury (CI) 1-2: 64.2%, CI-3: 77% and CI-4: 76%. The IC of CS-SPACE amounted before/after consensus of MM to 50.4/77%, LM 68.8/88%, ACL 89.9/94.5%, PCL 97.2/99.0%, CL 92.6/96.3%. IC of CI was evaluated without consensus and amounted to 65.1% (CI 1-2), 66% (CI 3) and 81.6% (CI 4). CONCLUSIONS: Injuries of ACL, PCL and CL have excellent IC between 3D and 2D sequences. Excellent IC could be found in CI grade 3 and 4 when using 2D sequences and CI grade 4 utilizing CS-SPACE. Our results indicate that CS-SPACE is useful in diagnosing acute knee injuries.


Assuntos
Imageamento Tridimensional , Traumatismos do Joelho , Articulação do Joelho , Adolescente , Adulto , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Tecnologia , Adulto Jovem
19.
Radiologe ; 61(9): 829-838, 2021 Sep.
Artigo em Alemão | MEDLINE | ID: mdl-34251481

RESUMO

CLINICAL/METHODOLOGICAL ISSUE: Multiparametric magnetic resonance imaging (mpMRI) of the prostate plays a crucial role in the diagnosis and local staging of primary prostate cancer. STANDARD RADIOLOGICAL METHODS: Image-guided biopsy techniques such as MRI-ultrasound fusion not only allow guidance for targeted tissue sampling of index lesions for diagnostic confirmation, but also improve the detection of clinically significant prostate cancer. METHODOLOGICAL INNOVATIONS: Minimally invasive, focal therapies of localized prostate cancer complement the treatment spectrum, especially for low- and intermediate-risk patients. PERFORMANCE: In patients of low and intermediate risk, MR-guided, minimally invasive therapies could enable local tumor control, improved functional outcomes and possible subsequent therapy escalation. Further study results related to multimodal approaches and the application of artificial intelligence (AI) by machine and deep learning algorithms will help to leverage the full potential of focal therapies for prostate cancer in the upcoming era of precision medicine. ACHIEVEMENTS: Completion of ongoing randomized trials comparing each minimally invasive therapy approach with established whole-gland procedures is needed before minimally invasive therapies can be implemented into existing treatment guidelines. PRACTICAL RECOMMENDATIONS: This review article highlights minimally invasive therapies of prostate cancer and the key role of mpMRI for planning and conducting these therapies.


Assuntos
Inteligência Artificial , Neoplasias da Próstata , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia
20.
Surg Radiol Anat ; 43(12): 2009-2023, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34599355

RESUMO

PURPOSE: Defining normal anthropometric ranges of proximal femur and femoral head for each age group in children/adolescents is a necessity when differentiating normal anatomical variants from pathological deformities. Aim of this study is to define a set of normal anthropometric parameters based on 3D-CT measurements in normal asymptomatic children/adolescents and analyse the variations arising depending on age, side, and/or gender. METHODS: Morphology of the proximal femur was retrospectively assessed in 170 hips (85 children, < 15 years). Measurements included covered femoral head volume (CFHV), femoral head diameter (FHD), femoral head extrusion index (FHEI), coronal alpha angle (CAA), lateral centre-edge angle (LCEA), anterior (AOS) and posterior head-neck offset (POS) and femoral neck-shaft angle (FNSA). Correlation analyses as well as inter- and intra-rater reliability were performed. RESULTS: CFHV, LCEA, FHD and AOS/POS increased with age and FHEI, CAA, and FNSA decreased with age. None of the measurements correlated with the side. AOS showed a poor correlation with gender. Rapid growth phases were observed at the age of 1, 7 and 11. The inter- and intra-rater reliability was high (range ICC 0.8-0.99 Cronbach alpha 0.86-0.99). CONCLUSION: This data delivers a description of growth phases as well as gender and age-correlated reference values of the proximal femoral morphology that could be used by paediatricians and orthopaedic/paediatric surgeons to early diagnose proximal femur deformities and provide guidance in the planning of possible operations.


Assuntos
Cabeça do Fêmur , Fêmur , Adolescente , Antropometria , Criança , Fêmur/diagnóstico por imagem , Cabeça do Fêmur/diagnóstico por imagem , Humanos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa