Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Europace ; 16(7): 1092-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24671168

RESUMO

AIMS: Heart rate turbulence (HRT) is a prognostic parameter for risk stratification in patients suffering from coronary artery disease. The aims of this study were to demonstrate the feasibility of quantifying HRT in mice, both in long-term electrocardiograms (ECGs) as well as after extrastimulus pacing, and to analyse its characteristics. METHODS AND RESULTS: We performed long-term ECG recordings using implanted telemetric chips and electrophysiological (EP) investigations, using transvenously inserted EP catheters, in healthy mice. Heart rate turbulence was calculated using the established turbulence onset (TO) and slope (TS) algorithm. After spontaneous ventricular premature complexes (VPCs), we found a negative TO (-2.2 ± 7.5%) and positive TS (15.5 ± 18.3 ms/RR interval). Electrophysiological investigations revealed positive values for TO (0.6 ± 1.1%) and TS (6.5 ± 2.9 ms/RR interval) after extrastimulus pacing maneuvers. The shortening of the extrastimuli coupling intervals delivered during EP investigations significantly influenced TO (r = 0.57; P = 0.01): shorter coupling intervals provoked more positive TO values. CONCLUSION: Mice display both spontaneous and induced HRT. In terms of TO, VPCs generated by extrastimulus pacing are significantly dependent on the coupling interval. Determining HRT in mice is feasible and provides insight into basic mechanisms of blood pressure regulation, which is realized by the baroreflex.


Assuntos
Arritmias Cardíacas/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Frequência Cardíaca , Algoritmos , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Barorreflexo , Pressão Sanguínea , Modelos Animais de Doenças , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Camundongos Endogâmicos C57BL , Valor Preditivo dos Testes , Processamento de Sinais Assistido por Computador , Telemetria , Fatores de Tempo , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/fisiopatologia
2.
Europace ; 14(11): 1596-601, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22611058

RESUMO

AIMS: The current study includes all consecutive patients with advanced heart failure and cardiac resynchronization therapy (CRT) with an implantable cardioverter defibrillator (ICD) over a 10-year period in a tertiary referral centre. It aims at identifying independent risk factors for mortality during CRT-defibrillator (CRT-D) treatment. METHODS AND RESULTS: This study includes 239 consecutive patients who had undergone implantation of a CRT-D system (ejection fraction 25.9 ± 8%; 139 patients with ischaemic, 100 patients with non-ischaemic cardiomyopathy). Enrolment took place between 2001 and 2010, resulting in a median follow-up of 43 ± 30 months. During follow-up, 59 patients (25%) died. An impaired baseline kidney function [hazard ratio (HR) 1.98; 95% confidence interval (CI) 1.7-3; P< 0.0001], appropriate ICD therapy during follow-up (HR 2.1; CI 1.1-3.4; P= 0.001), lack of beta-blocker therapy (HR 2.3; CI 1.6-3.8; P= 0.004), and intake of amiodarone (HR 2; CI 1.8-4.1; P< 0.0001) were identified as predictors of overall mortality. CONCLUSION: This study demonstrates the benefit of beta-blocker therapy also in patients on long-term CRT-D treatment. It confirms the prognostic significance of impaired renal function and the occurrence of appropriate ICD therapies also in CRT-D patients. It argues for an intensified follow-up regimen and adjustment of heart failure treatment whenever these prognostic markers are identified in a patient treated with CRT-D.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Amiodarona/uso terapêutico , Terapia de Ressincronização Cardíaca/efeitos adversos , Feminino , Alemanha , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Rim/fisiopatologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Centros de Atenção Terciária , Fatores de Tempo , Resultado do Tratamento
3.
Eur Heart J Qual Care Clin Outcomes ; 8(2): 104-112, 2022 03 02.
Artigo em Inglês | MEDLINE | ID: mdl-34849668

RESUMO

AIMS: During the early phase of the COVID-19 pandemic, hospital admissions for several medical and surgical conditions declined. Few data are available with respect to elective cardiac implantable electronic device (CIED) implantation. The aim of the present study was to determine the impact of the COVID-19 pandemic on the monthly CIED implantation rates in Germany (January-September 2020 vs. 2019). METHODS AND RESULTS: The monthly rates of CIED implantation for the 2019 pre- and 2020 pandemic periods were retrieved from the Institute für das Entgeltsystem im Krankenhaus using German Operation and Procedure Classification codes to identify pacemakers (PMs), implantable cardioverter/defibrillators (ICDs), and cardiac resynchronization therapy (CRT) systems. Compared with 2019, the COVID-19 pandemic was associated with an overall decline of CIED implantation rates of -2.6%, reaching -22.9% in April 2020. Stratified by device type, the patterns of implantation were similar between PMs and ICDs, with maximal declines of -24.3% and -23.2% in April, respectively. Thereafter, the implantation rates gradually increased before stabilizing to rates similar to those observed in 2019. CRT implantation rates also declined in the early pandemic wave, but the overall 2020 rates increased by +4.3% likely driven by an increase of +16.5% (June-September). All the observed percentage differences of monthly device type related implantation rates demonstrated a statistical significance. CONCLUSION: The COVID-19 pandemic had a significant impact on the implantation of CIEDs in Germany. A differential pattern of resource utilization was observed with a catch-up effect for PMs and ICDs. The implantation rates of CRT systems also declined, but they increased rapidly and remained higher than those of 2019.


Assuntos
COVID-19 , Desfibriladores Implantáveis , COVID-19/epidemiologia , Eletrônica , Alemanha/epidemiologia , Humanos , Pandemias , SARS-CoV-2
4.
Am Heart J ; 161(6): 1096-105, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21641356

RESUMO

BACKGROUND: Recent studies suggest that magnetic resonance (MR) imaging of the brain and spine may safely be performed in patients with pacemakers (PMs) and implantable cardioverter/defibrillators (ICDs), when taking adequate precautions. The aim of this study was to investigate safety, feasibility, and diagnostic value (DV) of MR imaging in cardiac applications (cardiac MR [CMR]) in patients with PMs and ICDs for the first time. METHODS: Thirty-two PM/ICD patients with a clinical need for CMR were examined. The specific absorption rate was limited to 1.5 W/kg. Devices were reprogrammed pre-CMR to minimize interference with the electromagnetic fields. Devices were interrogated pre-CMR and post-CMR and after 3 months. Troponin I levels were measured pre-CMR and post-CMR; image quality (IQ) and DV of CMR were assessed. RESULTS: All devices could be reprogrammed normally post-CMR. No significant changes of pacing capture threshold, lead impedance, and troponin I were observed. Image quality in patients with right-sided devices (RSD) was better compared with that in patients with left-sided devices (LSD) (P < .05), and less myocardial segments were affected by device-related artefacts (P < .05). Diagnostic value was rated as sufficiently high, allowing for diagnosis, or better in 12 (100%) of 12 patients with RSD, and only in 7 (35%) of 20 patients with LSD. CONCLUSIONS: Cardiac MR may be performed safely when limiting specific absorption rate, appropriately monitoring patients, and following device reprogramming. Cardiac MR delivers good IQ and DV in patients with RSD. Cardiac MR in patients with RSD may therefore be performed with an acceptable risk/benefit ratio, whereas the risk/benefit ratio is rather unfavorable in patients with LSD.


Assuntos
Desfibriladores Implantáveis , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Troponina I/sangue , Adulto , Idoso , Artefatos , Estimulação Cardíaca Artificial , Contraindicações , Técnicas de Imagem por Elasticidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão do Miocárdio , Adulto Jovem
5.
Europace ; 13(2): 221-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21252195

RESUMO

AIMS: Intracardiac electrograms (IEGMs) recorded by implantable cardioverter-defibrillators (ICDs) are essential for arrhythmia diagnosis and ICD therapy assessment. Short IEGM snapshots showing 3-10 s before arrhythmia detection were added to the Biotronik Home Monitoring system in 2005 as the first-generation IEGM Online. The RIONI study tested the primary hypothesis that experts' ratings regarding the appropriateness of ICD therapy based on IEGM Online and on standard 30 s IEGM differ in <10% of arrhythmia events. METHODS AND RESULTS: A total of 619 ICD patients were enrolled and followed for 1 year. According to a predefined procedure, 210 events recorded by the ICDs were selected for evaluation. Three expert board members rated the appropriateness of ICD therapy and classified the underlying arrhythmia using coded IEGM Online and standard IEGM to avoid bias. The average duration of IEGM Online was 4.4±1.5 s. According to standard IEGM, the underlying arrhythmia was ventricular in 135 episodes (64.3%), supraventricular in 53 episodes (25.2%), oversensing in 17 episodes (8.1%), and uncertain in 5 episodes (2.4%). The expert board's rating diverged between determinable IEGM Online tracings and standard IEGM in 4.6% of episodes regarding the appropriateness of ICD therapy (95% CI up to 8.0%) and in 6.6% of episodes regarding arrhythmia classification (95% CI up to 10.5%). CONCLUSION: By enabling accurate evaluation of the appropriateness of ICD therapy and the underlying arrhythmia, the first-generation IEGM Online provided a clinically effective basis for timely interventions and for optimized patient management schemes, which was comparable with current IEGM recordings.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Técnicas Eletrofisiológicas Cardíacas/métodos , Monitorização Ambulatorial/métodos , Tecnologia de Sensoriamento Remoto/métodos , Idoso , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/instrumentação , Estudos Prospectivos , Tecnologia de Sensoriamento Remoto/instrumentação , Reprodutibilidade dos Testes
6.
Herzschrittmacherther Elektrophysiol ; 32(2): 227-235, 2021 Jun.
Artigo em Alemão | MEDLINE | ID: mdl-33982176

RESUMO

The possibility of outpatient implantation of defibrillators, devices for cardiac resynchronization, and event recorders (collectively called cardiac implantable electronic devices, CIEDs) is becoming increasingly important. In Germany, only a few options for outpatient implantation are currently realized. Furthermore, there is a lack of uniform, recognized, and binding quality criteria. This article provides insight into the current contract constellations for outpatient surgery and defines a first, holistic quality concept for outpatient implantations of CIEDs. The present works aims to initiate a discourse in the specialist society in order to define a coordinated, binding quality concept. Then, this should serve as the basis for future outpatient implantation services, enabling comparability and to contribute long-term evidence.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Dispositivos de Terapia de Ressincronização Cardíaca , Alemanha , Humanos , Pacientes Ambulatoriais
7.
Europace ; 12(1): 52-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19933517

RESUMO

AIMS: Left atrial catheter ablation of the pulmonary veins (PV) has evolved as an important therapeutic option for the treatment of atrial fibrillation (AF). We aimed to investigate the incidence and predictors of silent cerebral embolism associated with PV catheter ablation, detected by diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS AND RESULTS: We performed a prospective analysis of 53 consecutive patients with persistent or paroxysmal AF that underwent PV ablation and post-procedural cerebral MRI 1 day after lasso catheter-guided ostial PV ablation. Patients were analysed for possible demographical, medical, echocardiographical, and procedural predictors of embolic events. A mean of 3.5 +/- 0.5 PVs were ablated per patient. In six patients, DW-MRI depicted new clinically silent microembolism after PV ablation (11%). The number of ineffective medical antiarrhythmic agents prior to ablation procedure was significantly higher in the embolism group (3.3 +/- 0.5 vs. 2.2 +/- 1.4, P = 0.014). Coronary heart disease (CAD) was more frequent in patients with cerebral embolisms (33 vs. 2%, P = 0.031); left ventricular volume (130 +/- 12 vs. 103 +/- 26 mL, P = 0.002), and septal wall thickness (13.0 +/- 1.4 vs. 7.9 +/- 4.8 mm, P = 0.025) were significantly increased. CONCLUSION: This study shows a high incidence of silent micro-embolic events after PV ablation. CAD, left ventricular dilatation, and hypertrophy were potential predictors of this complication.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Embolia Intracraniana/epidemiologia , Veias Pulmonares/cirurgia , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Imageamento por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Medição de Risco/métodos , Fatores de Risco
8.
Sci Rep ; 6: 21748, 2016 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-26892534

RESUMO

The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥ 170 bpm (ventricular tachycardia zone) and at rates ≥ 200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥ 170 bpm than at rates ≥ 200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170-200 bpm) in the SC population.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Taquicardia Ventricular/terapia , Idoso , Algoritmos , Morte Súbita Cardíaca , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Resultado do Tratamento
9.
Clin Res Cardiol ; 104(12): 1021-32, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26002818

RESUMO

BACKGROUND: A significant number of patients with an implantable cardioverter/defibrillator (ICD) for primary prevention receive inappropriate shocks. Previous studies have reported a reduction of inappropriate therapies with simple modifications of ICD detection settings, however, inclusion criteria and settings varied markedly between studies. Our aim was to investigate the effect of raising the ICD detection zone in the entire primary prevention ICD population. METHODS AND RESULTS: 543 patients receiving an ICD for primary prevention were randomized to either conventional or progressive ICD programming. The detection rate was programmed at 171 bpm for ventricular tachycardia (VT) and 214 bpm for ventricular fibrillation (VF) in the Conventional group and 187 bpm for VT and 240 bpm for VF in the Progressive group. 43 % of patients received single-chamber and 57 % dual-chamber detection devices (DDD-ICD 19 %; CRT-D 38 %). The primary endpoint consisted of inappropriate therapies and untreated VT/VF. The primary endpoint was reached in 35 patients (13 %) in the Conventional group and 17 patients (6 %) in the Progressive group (p = 0.004). Progressive ICD programming led to significantly fewer amount of patients with ICD therapies (26 vs. 14 %; p < 0.001) and shocks (11 vs. 5 %; p = 0.023) compared to conventional ICD programming. Sub-analyses showed the greatest reduction of inappropriate therapies and shocks in dual-chamber detection devices with progressive compared to single-chamber detection devices with conventional ICD programming (p < 0.001). CONCLUSIONS: Progressive ICD programming reduces the number of inappropriate therapies and shocks in a broad primary prevention ICD population particularly in combination with dual-chamber detection algorithms. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov ; ClinicalTrials.gov identifier NCT01217528.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Algoritmos , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prevenção Primária/métodos , Estudos Prospectivos
10.
JACC Heart Fail ; 2(6): 611-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25282033

RESUMO

OBJECTIVES: The OPTION (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator Patients Without Pacing Indications) trial sought to compare long-term rates of inappropriate shocks, mortality, and morbidity between dual-chamber and single-chamber settings in implantable cardioverter-defibrillators (ICDs) patients. BACKGROUND: The use of dual-chamber ICDs potentially allows better discrimination of supraventricular arrhythmias and thereby reduces inappropriate shocks. However, it may lead to detrimental ventricular pacing. METHODS: This prospective multicenter, single-blinded trial enrolled 462 patients with de novo primary or secondary prevention indications for ICD placement and with left ventricular ejection fractions ≤40% despite optimal tolerated pharmacotherapy. All patients received atrial leads and dual-chamber defibrillators that were randomized to be programmed either with dual-chamber or single-chamber settings. In the dual-chamber setting arm, the PARAD+ algorithm, which differentiates supraventricular from ventricular arrhythmias, and SafeR mode, to minimize ventricular pacing, were activated. In the single-chamber setting arm, the acceleration, stability, and long cycle search discrimination criteria were activated, and pacing was set to VVI 40 beats/min. Ventricular tachycardia detection was required at rates between 170 and 200 beats/min, and ventricular fibrillation detection was activated above 200 beats/min. RESULTS: During a follow-up period of 27 months, the time to the first inappropriate shock was significantly longer in the dual-chamber setting arm (p = 0.012, log-rank test), and 4.3% of patients in the dual-chamber setting group compared with 10.3% in the single-chamber setting group experienced inappropriate shocks (p = 0.015). Rates of all-cause death or cardiovascular hospitalization were 20% for the dual-chamber setting group and 22.4% for the single-chamber setting group and satisfied the pre-defined margin for equivalence (p < 0.001). CONCLUSIONS: Therapy with dual-chamber settings for ICD discrimination combined with algorithms for minimizing ventricular pacing was associated with reduced risk for inappropriate shock compared with single-chamber settings, without increases in mortality and morbidity. (Optimal Anti-Tachycardia Therapy in Implantable Cardioverter-Defibrillator [ICD] Patients Without Pacing Indications [OPTION]; NCT00729703).


Assuntos
Fibrilação Atrial/terapia , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Supraventricular/terapia , Fibrilação Atrial/mortalidade , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Método Simples-Cego , Taquicardia Supraventricular/mortalidade , Resultado do Tratamento
11.
Clin Cardiol ; 35(9): 575-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22707222

RESUMO

BACKGROUND: A growing number of patients with advanced heart failure fulfill a primary-prevention indication for an implantable cardioverter-defibrillator (ICD). This study seeks to identify new predictors of overall mortality in a Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT)-like collective to enhance risk stratification. HYPOTHESIS: An impaired renal function and severely depressed left ventricular ejection fraction pose relevant risk factors for mortality in primary prevention ICD recipients. METHODS: Ninety-four consecutive ICD patients with New York Heart Association class II-III heart failure and depressed left ventricular function (left ventricular ejection fraction [LVEF] ≤ 35%) with no history of malignant ventricular arrhythmias were followed for 34 ± 20 months. RESULTS: During this period, 30 patients died (32%). Deceased patients revealed a significantly worse renal function before ICD implantation (1.55 ± 0.7 mg/dL vs 1.1 ± 0.4 mg/dL; P = 0.007), suffered more often from coronary artery disease (53 vs 29; P = 0.006), and were older (69.5 ± 8 y vs 67 ± 12 y; P = 0.0002) than surviving patients. Furthermore, increased serum creatinine at baseline (2 mg/dL vs 1 mg/dL; odds ratio [OR]: 3.96, 95% confidence interval [CI]: 1.2-13.04, P = 0.02), presence of coronary artery disease (OR: 8.6, 95% CI: 1.1-65, P = 0.036), and low LVEF (OR per 5% baseline LVEF deterioration: 1.4, 95% CI: 1-1.8, P = 0.034) represented strong and independent predictors for overall mortality. CONCLUSIONS: Impaired renal function, the presence of coronary artery disease, and reduced LVEF before implantation represent independent predictors for mortality in a cohort of patients with advanced systolic heart failure. These conditions still bear a high mortality risk, even if ICD implantation effectively prevents sudden arrhythmic death. Indeed, in patients suffering from several of the identified "high-risk" comorbidities, primary-prevention ICD implantation might have a limited survival benefit. The possible adverse effects of these comorbidities should be openly discussed with the potential ICD recipient and his or her close relatives.


Assuntos
Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Insuficiência Cardíaca/complicações , Nefropatias/complicações , Disfunção Ventricular Esquerda/complicações , Idoso , Arritmias Cardíacas , Morte Súbita Cardíaca/prevenção & controle , Seguimentos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Humanos , Nefropatias/mortalidade , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Análise de Sobrevida , Disfunção Ventricular Esquerda/mortalidade
12.
Clin Res Cardiol ; 101(10): 829-36, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22588842

RESUMO

BACKGROUND: The impact of atrial fibrillation (AF) on heart failure (HF) was evaluated in patients with preserved left ventricular (LV) function and long-term right ventricular (RV) pacing for complete heart block. METHODS: Clinical, echocardiographic, and laboratory parameters of HF were assessed in 35 patients with established AF who had undergone ablation of the atrioventricular node and pacemaker implantation (Group A) and 31 patients who received dual-chamber pacing for spontaneous complete heart block (Group B). RESULTS: During a follow-up period of 12.7 ± 7.5 years, New York Heart Association (NYHA) functional class increased from 1.3 ± 0.5 to 2.1 ± 0.6 (p < 0.0001) in Group A, and from 1.3 ± 0.4 to 1.6 ± 0.7 (p < 0.01) in Group B. Left ventricular ejection fraction (LVEF) decreased from 59.7 ± 5.1 to 53.0 ± 8.2 (p < 0.0001) in Group A, but remained stable (58.6 ± 4.2 vs. 56.9 ± 7.0 %, p = 0,21) in Group B. At the end of follow-up, markers of LV function were moderately depressed in Group A compared with those in Group B: NYHA class 2.1 ± 0.6 versus 1.6 ± 0.7, p = 0.001; LVEF 53.0 ± 8.2 versus 56.9 ± 7.0 %, p < 0.05; LV diastolic diameter 53.6 ± 5.8 mm versus 50.7 ± 4.9 mm, p < 0.05; N-terminal pro-brain natriuretic peptide (NT-proBNP) 1116.8 ± 883.9 versus 622.9 ± 1059.4 pg/ml, p < 0.05. Progression of paroxysmal AF to permanent AF during follow-up was common, while new onset of AF was rare. Permanent AF was an independent predictor of declining LVEF >10 %, increasing NYHA class ≥1, and NT-proBNP levels >1,000 pg/ml. CONCLUSIONS: Permanent AF was associated with adverse effects on LV function and symptoms of HF in patients with long-term RV pacing for complete heart block, and appears to play an important role in the development of HF in this specific patient cohort.


Assuntos
Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Bloqueio Cardíaco/terapia , Insuficiência Cardíaca/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Progressão da Doença , Feminino , Seguimentos , Bloqueio Cardíaco/fisiopatologia , Insuficiência Cardíaca/etiologia , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
13.
J Am Coll Cardiol ; 54(6): 549-55, 2009 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-19643318

RESUMO

OBJECTIVES: Our aim was to establish and evaluate a strategy for safe performance of magnetic resonance imaging (MRI) at 1.5-T in patients with implantable cardioverter-defibrillators (ICDs). BACKGROUND: Expanding indications for ICD placement and MRI becoming the imaging modality of choice for many indications has created a growing demand for MRI in ICD patients, which is still considered an absolute contraindication. METHODS: Non-pacemaker-dependent ICD patients with a clinical need for MRI were included in the study. To minimize radiofrequency-related lead heating, the specific absorption rate was limited to 2 W/kg. ICDs were reprogrammed pre-MRI to avoid competitive pacing and potential pro-arrhythmia: 1) the lower rate limit was programmed as low as reasonably achievable; and 2) arrhythmia detection was programmed on, but therapy delivery was programmed off. Patients were monitored using electrocardiography and pulse oximetry. All ICDs were interrogated before and after the MRI examination and after 3 months, including measurement of pacing capture threshold, lead impedance, battery voltage, and serum troponin I. RESULTS: Eighteen ICD patients underwent a total of 18 MRI examinations at 1.5-T; all examinations were completed safely. All ICDs could be interrogated and reprogrammed normally post-MRI. No significant changes of pacing capture threshold, lead impedance, and serum troponin I were observed. Battery voltage decreased significantly from pre- to post-MRI. In 2 MRI examinations, oversensing of radiofrequency noise as ventricular fibrillation occurred. However, no attempt at therapy delivery was made. CONCLUSIONS: MRI of non-pacemaker-dependent ICD patients can be performed with an acceptable risk/benefit ratio under controlled conditions by taking both MRI- and pacemaker-related precautions. (Implantable Cardioverter Defibrillators and Magnetic Resonance Imaging of the Heart at 1.5-Tesla; NCT00356239).


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Segurança de Equipamentos/instrumentação , Imageamento por Ressonância Magnética , Segurança de Equipamentos/métodos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Fatores de Risco
14.
Pacing Clin Electrophysiol ; 30 Suppl 1: S125-7, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17302687

RESUMO

BACKGROUND: We evaluated the number of appropriate and inappropriate therapies for ventricular tachyarrhythmias and trigger mechanisms in 55 MADIT II (MII)-like (group 1) and 86 SCD-HeFT-like (group 2) patients. METHODS AND RESULTS: We analyzed 399 appropriate episodes in 31 patients with implantable cardioverter defibrillators (ICD) implanted according to the MII trial indications, and 502 appropriate episodes in 47 patients matching the SCD-HeFT trial criteria (mean follow-up in both groups = 33 +/- 19 months). In group 1, 39 treated episodes were inappropriate (9% of all episodes), while in group 2, 76 episodes were treated inappropriately (15% of all episodes). At least one episode of inappropriate ICD therapy was recorded in 18% of patients in group 1 (n = 10) and in 22% of patients in group 2 (n = 19). CONCLUSIONS: Our study supports the implantation of ICD as primary prevention in patients who are at risk of sudden cardiac death, although the proportion of inappropriate ICD interventions remains high.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Taquicardia Ventricular/terapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos
15.
Int J Cardiol ; 114(3): 323-31, 2007 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-16740324

RESUMO

BACKGROUND: Inappropriate therapy for supraventricular tachyarrhythmia is still a major problem in implantable cardioverter defibrillators (ICD). The morphology discrimination algorithm compares the morphology of a tachycardia electrogram with a stored template on a beat-to-beat basis. However, algorithm responders could not yet be identified prior to the occurrence of first tachycardia episodes. We analyzed whether rapid atrial pacing and/or exercise testing can be used for identification of responders and compared the results with ICD detected tachycardia. METHODS: 22 patients (16 male, 61+/-14 years) with dual-chamber ICDs have been enrolled. Patients underwent a standardized bicycle exercise testing and an atrial pacing protocol. For both tests, morphology match scores of 8 consecutive beats were analyzed for each 10-bpm-step increment above sinus rhythm. Patients were categorized as responders, if morphology match was > or = 90% of tested heart rates. During follow-up, ICD stored episodes with morphology discrimination activated were evaluated. RESULTS: There were no significant differences between morphology match (85+/-29% vs. 84+/-27%) and linear regression slope B (-0.19+/-0.87 vs. -0.20+/-0.48) during exercise testing and atrial pacing. 16 patients (73%) were classified as responders. During follow-up (739+/-338 days) 121 sustained supraventricular (n=88) and ventricular tachycardia (n=33) were detected in 10 patients (45%). Specificity for tachycardia discrimination was 78% overall, 100% in responders and 22% in non-responders. CONCLUSION: Exercise testing and atrial pacing were equally suitable for identification of patients who seem to respond to the morphology discrimination algorithm with a high specificity for ventricular tachycardia discrimination. Thus, morphology match tests are suggested to optimize tachycardia discrimination and to reduce inadequate therapies.


Assuntos
Algoritmos , Desfibriladores Implantáveis , Taquicardia Supraventricular/terapia , Distribuição de Qui-Quadrado , Eletrocardiografia , Teste de Esforço , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
16.
Ann Noninvasive Electrocardiol ; 12(4): 306-15, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17970956

RESUMO

BACKGROUND: Patients with atrial fibrillation (AF) often exhibit abnormalities of P wave morphology during sinus rhythm. We examined a novel method for automatic P wave analysis in the 24-hour-Holter-ECG of 60 patients with paroxysmal or persistent AF and 12 healthy subjects. METHODS: Recorded ECG signals were transferred to the analysis program where 5-10 P and R waves were manually marked. A wavelet transform performed a time-frequency decomposition to train neural networks. Afterwards, the detected P waves were described using a Gauss function optimized to fit the individual morphology and providing amplitude and duration at half P wave height. RESULTS: >96% of P waves were detected, 47.4 +/- 20.7% successfully analyzed afterwards. In the patient population, the mean amplitude was 0.073 +/- 0.028 mV (mean variance 0.020 +/- 0.008 mV(2)), the mean duration at half height 23.5 +/- 2.7 ms (mean variance 4.2 +/- 1.6 ms(2)). In the control group, the mean amplitude (0.105 +/- 0.020 ms) was significantly higher (P < 0.0005), the mean variance of duration at half height (2.9 +/- 0.6 ms(2)) significantly lower (P < 0.0085). CONCLUSIONS: This method shows promise for identification of triggering factors of AF.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador , Estatísticas não Paramétricas , Fatores de Tempo
17.
Hellenic J Cardiol ; 46(1): 31-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15807392

RESUMO

INTRODUCTION: A decline in the acceleration of the heart rate (HR, heart rate turbulence, HRT) after a ventricular premature capture is associated with increased mortality in patients suffering from coronary artery disease. The physiological properties of HRT have not been evaluated in a large human cohort. METHODS: In 95 healthy individuals, HRT parameters onset (TO) and slope (TS) as well as the turbulence timing (TT) were calculated from 24-hour Holter ECGs. With the help of a simple, linear, weighted regression model, gender specific differences of TO and TS were compared. A multiple linear regression model served to evaluate the influence of age and the basic HR preceding the ventricular premature contraction (VPC) on HRT. RESULTS: The median of TT is present in regression line #5. We discovered that, in men and women, TO is reduced as basic HR rises (p<0.01). In contrast, analysis of TS showed a divergence: in men, TS declines as basic HR increases. However, basic HR modifies TS in women to some extent (p<0.01). A multiple, linear regression model revealed a decrease of HRT with increasing age in men. CONCLUSIONS: The acceleration of HR after a ventricular premature beat occurred within the first 11 beats in more than 75% of our healthy individuals. An increased HR prior to VPC affects HRT in men. Increasing age leads to an attenuation of HRT in men and to a reduction of TO in women. These results emphasise the significance of the physiological properties of HRT when using HRT for risk stratification, especially in elderly patients.


Assuntos
Eletrocardiografia Ambulatorial/métodos , Frequência Cardíaca/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Adaptação Fisiológica , Adulto , Fatores Etários , Estudos de Coortes , Eletrocardiografia , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Probabilidade , Valores de Referência , Medição de Risco , Fatores Sexuais , Complexos Ventriculares Prematuros/mortalidade
18.
Herz ; 30(8): 733-42, 2005 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-16331369

RESUMO

Several prospective randomized clinical trials have reported that atrial-based "physiological" pacing is associated with a lower incidence of paroxysmal and permanent atrial fibrillation than single-chamber ventricular pacing in patients with conventional pacemaker indication. Whether atrial pacing itself is antiarrhythmic remains still uncertain. By contrast, right ventricular pacing is considered to beget atrial fibrillation, even in preserved AV synchrony during dual-chamber pacing. A number of clinical trials investigated the impact of sitespecific atrial pacing and advanced atrial pacing algorithms on the secondary prevention of atrial fibrillation. Multisite pacing (dual-site right atrial or biatrial pacing) was demonstrated to add only minimal benefit for the prevention of atrial fibrillation. By contrast, in some studies septal pacing and specific atrial pacing algorithms were reported to reduce the recurrence of atrial fibrillation in selected patients. At present, however, it remains unclear how to identify these patients. In clinical practice, the effectiveness of specific atrial pacing algorithms and/or septal pacing has to be tested out in the individual case. These therapeutic options should be considered in patients with a conventional indication for antibradycardia pacing and, additionally, symptomatic atrial fibrillation.


Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/tendências , Terapia Assistida por Computador/métodos , Algoritmos , Ensaios Clínicos como Assunto , Humanos , Guias de Prática Clínica como Assunto , Padrões de Prática Médica/tendências
19.
Pacing Clin Electrophysiol ; 28 Suppl 1: S198-201, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15683496

RESUMO

Postextrasystolic acceleration of heart rate (HR), known as HR turbulence (HRT) is attenuated in patients with coronary artery disease at increased risk of adverse events. The influence of age and basic HR on HRT have not been evaluated in a large cohort of persons. In 95 healthy individuals, HRT onset (TO) and slope (TS) were calculated from 24-hour ambulatory electrocardiograms, as well as the turbulence timing (TT). Gender specific differences in TO and TS were compared in simple, linear, weighted regression model. The influence of age and the basic HR preceding ventricular premature contractions on HRT were examined. We found that, in men and women, TO decreases as basic HR increases (P < 0.01). In contrast, in men, TS decreased as basic HR increases, whereas in women, basic HR influenced TS only slightly (P < 0.01). A multiple, linear regression model revealed a decrease in HRT with increasing age in men. In conclusion, physiological acceleration of the HR within the first 11 beats after premature ventricular complex (VPC) was observed in >75% of healthy individuals. An accelerating HR preceding the VPC influenced HRT in men. An increasing age was associated with a decrease in HRT in men and a decrease in TO in women. These results illustrate the importance of physiological modulations of HRT when used for risk stratification, especially in older populations.


Assuntos
Frequência Cardíaca/fisiologia , Adulto , Fatores Etários , Eletrocardiografia Ambulatorial , Feminino , Hemodinâmica , Humanos , Masculino , Valores de Referência
20.
Pacing Clin Electrophysiol ; 26(1P2): 310-3, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12687835

RESUMO

Pacing algorithms to prevent PAF are mainly based on the suppression of premature atrial complexes (PACs), which play an important role in its initiation. In contrast to 24-hour ambulatory electrocardiograms, advanced pacemaker (PM) diagnostic features are capable of recording AF episodes during long follow-up periods and of characterizing AF in a detailed fashion. For the specific use of these algorithms, a detailed characterization of AF was performed in 91 dual chamber PM recipients with histories of AF. Fifteen patients with episodes of oversensing due to far-field signals or frequent episodes of "2:1-undersensing" of atrial flutter were excluded. The remaining 76 patients had high recurrence rates of AF (median 0.8 episodes/day), however, the majority of episodes lasted < 7 minutes. Despite frequent PACs (median 10.8/hour) during sinus rhythm, a median of 66.4% of the AF episodes were preceded by < 2 PACs/min before onset. In conclusion, frequent, short-lived AF episodes seem best suited for AF preventive pacing therapies. However, the small number of PACs preceding many AF episodes may limit the efficacy of PAC suppressing algorithms.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Algoritmos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa