Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Biomater Sci ; 8(9): 2611-2626, 2020 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-32239020

RESUMO

Current cell expansion methods for tissue engineering and regenerative medicine applications rely on the use of enzymatic digestion passaging and 2D platforms. However, this enzymatic treatment significantly reduces cell quality, due to the destruction of important cell-surface proteins. In addition, culture in 2D results in undesired de-differentiation of the cells caused by the lack of 3D similarity to the natural extracellular matrix (ECM) environment. Research has led to the development of thermo-responsive surfaces for the continuous culture of cells. These thermo-responsive materials properties can be used to passage cells from the surface when the cell culture temperature is reduced. Here we report the development of a PLA/thermo-responsive (PDEGMA) blend 3D electrospun fibre-based scaffold to create an enzymatic-free 3D cell culture platform for the expansion of mammalian cells with the desired phenotype for clinical use. Human corneal stromal cells (hCSCs) were used as an exemplar as they have been observed to de-differentiate to an undesirable myo-fibroblastic phenotype when cultured by conventional 2D cell culture methods. Scaffolds were functionalised with a cell adherence peptide sequence GGG-YIGSR by thiol-ene chemistry to improve cell adherence and phenotype support. This was obtained by functionalising the thermo-responsive polymer with a thiol (PDEGMA/PDEGSH) by co-polymerisation. These incorporated thiols react with the norbornene acid functionalised peptide (Nor-GGG-YIGSR) under UV exposure. Presence of the thiol in the scaffold and subsequent peptide attachment on the scaffolds were confirmed by fluorescence labelling, ToF-SIMS and XPS analysis. The biocompatibility of the peptide containing scaffolds was assessed by the adhesion, proliferation and immuno-staining of hCSCs. Significant increase in hCSC adherence and proliferation was observed on the peptide containing scaffolds. Immuno-staining showed maintained expression of the desired phenotypic markers ALDH, CD34 and CD105, while showing no or low expression of the undesired phenotype marker α-SMA. This desired expression was observed to be maintained after thermo-responsive passaging and higher when cells were cultured on PLA scaffolds with 10 wt% PDEGMA/4 mol% PDEGS-Nor-GGG-YIGSR. This paper describes the fabrication and application of a first generation, biocompatible peptide conjugated thermo-responsive fibrous scaffold. The ease of fabrication, successful adherence and expansion of a therapeutically relevant cell type makes these scaffolds a promising new class of materials for the application of cell culture expansion platforms in the biomaterials and tissue engineering field.


Assuntos
Técnicas de Cultura de Células , Engenharia Tecidual , Alicerces Teciduais , Adesão Celular , Proliferação de Células , Sobrevivência Celular , Células Cultivadas , Córnea/citologia , Matriz Extracelular , Humanos , Peptídeos , Fenótipo , Polímeros , Células Estromais
2.
Biomed Mater ; 12(5): 055009, 2017 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-28643700

RESUMO

Electrospun fibrous materials have increasing applications in regenerative medicine due to the similarity of fibre constructs to the morphology of certain extracellular matrices. Although experimentally the electrospinning method is relatively simple, at the theoretical level the interactions between process parameters and their influence on the fibre morphology is not yet fully understood. Here, we hypothesised that a design of experiments (DoE) model could determine combinations of process parameters that result in significant effects on poly-D,L-lactic acid (PDLLA) fibre morphology. The process parameters used in this study were applied voltage, needle-to-collector distance, flow rate and polymer concentration. Data obtained for mean fibre diameter, standard deviation (SD) of the fibre diameter (measure of fibre morphology) and presence of 'beading' on the fibres (beads per µm2) were evaluated as a measure of PDLLA fibre morphology. Uniform fibres occurred at SDs of ≤500 nm, 'beads-on-string' morphologies were apparent between ±500 and 1300 nm and large beads were observed at ±1300-1800 nm respectively. Mean fibre diameter was significantly influenced by the applied voltage and interaction between flow rate and polymer concentration. Fibre morphology was mainly influenced by the polymer concentration, while bead distribution was significantly influenced by the polymer concentration as well as the flow rate. The resultant DoE model regression equations were tested and considered suitable for the prediction of parameters combinations needed for desired PDLLA fibre diameter and additionally provided information regarding the expected fibre morphology.


Assuntos
Matriz Extracelular/química , Poliésteres/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Animais , Técnicas de Cultura de Células , Microscopia Eletrônica de Varredura , Modelos Estatísticos , Ácido Poliglicólico , Polímeros/química , Análise de Regressão
3.
J Hosp Infect ; 85(3): 220-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24080083

RESUMO

BACKGROUND: Hand hygiene compliance is the single most effective way to reduce healthcare-associated infections. Children are notoriously vulnerable to infection as well as acting as conduits to transmission. Based on these observations, the authors formulated the hypothesis that behavioural change which improved children's hand hygiene compliance would decrease the spread of infectious diseases. AIM: To create an educational intervention to induce long-term behavioural change culminating in increased hand hygiene compliance of children, and thus a decrease in the rate of infections. METHODS: Focus groups conducted during interactive teaching sessions identified what children felt would help them to increase their hand hygiene compliance. This informed the design of an educational device that was subsequently trialled to measure its effectiveness in increasing hand hygiene compliance. Initial developmental stages were conducted in two schools in the East Midlands with study participants aged 5-8 years; the device was subsequently used in a healthcare setting to assess deployment flexibility. FINDINGS: Focus groups indicated that children enjoyed interactive learning, developed knowledge about cross-transmission of infections, and became motivated to encourage others to improve hand hygiene compliance. Microbiological swabbing verified the presence of pathogens on children's hands and environmental surfaces that could serve as reservoirs of infection, and questionnaires indicated an increase in handwashing following the intervention. CONCLUSION: Educational interventions have the potential to increase hand hygiene and reduce the transmission of infections.


Assuntos
Terapia Comportamental/métodos , Fidelidade a Diretrizes , Higiene das Mãos/métodos , Educação em Saúde/métodos , Cooperação do Paciente , Criança , Pré-Escolar , Feminino , Humanos , Masculino
4.
Work ; 41 Suppl 1: 1625-31, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22316948

RESUMO

The study was undertaken to investigate the effects of pacing on aspects of performance at an assembly task and on the operators' responses related to work behaviour, perceived workload and perceived stress. A particular objective of the study was to investigate whether physical and cognitive demands may interact in their influences on these effects. An assembly task was simulated in the laboratory and the level of pacing imposed, work height and memory load within the task were all varied. The results showed that the type of pacing commonly imposed (as is common with a lean manufacturing Takt time system in industry) can significantly affect both performance and perceived workload and stress. Physical demands (through work height affecting posture) and mental demand (through memory load) were also found to have significant effects, as would be expected from the many studies of these in the literature. More importantly, some interactions were found between pacing and work height in their effects on quality of assembly and the operator's own rating of performance, and between work height and memory load in their effects on errors. These findings will need to be taken into account by companies when implementing Takt time systems.


Assuntos
Indústrias , Análise e Desempenho de Tarefas , Adulto , Automóveis , Feminino , Humanos , Masculino , Processos Mentais/fisiologia , Pessoa de Meia-Idade , Postura/fisiologia , Estresse Fisiológico , Carga de Trabalho/psicologia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa