Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(9): 2079-2088, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37987767

RESUMO

Sufficient homogeneity of the certified parameter(s) over the whole fill series of a matrix reference material (RM) is a fundamental quality criterion. In practice, the heterogeneity of the target parameter is evaluated, whereby a relative value can be calculated of how much the target parameter is varying over the RM-batch. A high degree of homogeneity (low heterogeneity) is an inherent quality mark of a good RM. Here, we report how challenging matrix RMs were produced by using particle suspensions at the core of the material processing step. The examples of matrix RMs produced span from whole water reference materials for persistent organic pollutants, PM2.5-like atmospheric dust certified for specific ions to microplastic RMs. Most of these RMs were subsequently used in different phases of analytical method development or for method validation. Common to all these matrices is that they cannot be easily mixed, handled, or dosed to prepare larger sample batches. In all cases, a continuously stirred suspension of particles was used during material processing. In general, relative between-bottle heterogeneities from 1.6 to 6% were achieved for the target parameters in these matrix presentations. Concerning developments of new CRMs in emerging fields, the co-dependence between the availability of validated analytical methods with good repeatability and testing materials with a known and high homogeneity of the target parameter(s) becomes particularly challenging. This situation is an RM/Method causality dilemma. To overcome that hurdle, strategies are proposed for stepwise processes where RM producers and a network of analytical method developers could work hand in hand. In addition, development of a portfolio of inexpensive and well-homogenised common samples coupled with a reporting interface is suggested. This would benefit method developers and RM producers alike. As more and more data is compiled for a specific matrix, it paves the way for new and challenging RMs that can later be used by a wider community.

2.
Anal Bioanal Chem ; 416(3): 773-785, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37723254

RESUMO

The National Institute of Standards and Technology (NIST) has prepared four seafood reference materials (RMs) for use in food safety and nutrition studies: wild-caught and aquacultured salmon (RM 8256 and RM 8257) and wild-caught and aquacultured shrimp (RM 8258 and RM 8259). These materials were characterized using genetic, metabolomic (1H-NMR, nuclear magnetic resonance and LC-HRMS/MS, liquid chromatography high-resolution tandem mass spectrometry), lipidomic, and proteomic methods to explore their use as matrix-matched, multi-omic differential materials for method development towards identifying product source and/or as quality control in untargeted omics studies. The results from experimental replicates were reproducible for each reference material and analytical method, with the most abundant features reported. Additionally, differences between the materials could be detected, where wild-caught and aquacultured seafood could be distinguished using untargeted metabolite, lipid, and protein analyses. Further processing of the fresh-frozen RMs by freeze-drying revealed the freeze-dried seafoods could still be reliably discerned. These results demonstrate the usefulness of these reference materials as tools for omics instrument validation and measurement harmonization in seafood-related studies. Furthermore, their use as differential quality control (QC) materials, regardless of preparation method, may also provide a tool for laboratories to demonstrate proficiency at discriminating between products based on source/species.


Assuntos
Multiômica , Proteômica , Padrões de Referência , Controle de Qualidade , Alimentos Marinhos/análise
3.
Anal Bioanal Chem ; 416(12): 3045-3058, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38546794

RESUMO

Increasing demand for size-resolved identification and quantification of microplastic particles in drinking water and environmental samples requires the adequate validation of methods and techniques that can be used for this purpose. In turn, the feasibility of such validation depends on the existence of suitable certified reference materials (CRM). A new candidate reference material (RM), consisting of polyethylene terephthalate (PET) particles and a water matrix, has been developed. Here, we examine its suitability with respect to a homogeneous and stable microplastic particle number concentration across its individual units. A measurement series employing tailor-made software for automated counting and analysis of particles (TUM-ParticleTyper 2) coupled with Raman microspectroscopy showed evidence of the candidate RM homogeneity with a relative standard deviation of 12% of PET particle counts involving particle sizes >30 µm. Both the total particle count and the respective sums within distinct size classes were comparable in all selected candidate RM units. We demonstrate the feasibility of production of a reference material that is sufficiently homogeneous and stable with respect to the particle number concentration.

4.
Anal Bioanal Chem ; 415(15): 3033-3040, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36750474

RESUMO

Here, we report on the feasibility of using quantitative NMR and ultra-microbalances for additional measurements of the mass of poly-ethylene terephthalate (PET) particles in a reference material (RM). The microplastic (MP) PET particles were immobilised in solid NaCl following freeze-drying of a 1-ml NaCl suspension. The particles ranged from 30 to about 200 µm (Feretmin). In a 3-day process, more than 500 such units of PET particles in the NaCl carrier were prepared and later used in a large-scale inter-laboratory comparison. The homogeneity of PET in the salt carrier over these 500 units had previously been evaluated with respect to the mass of PET using an ultra-microbalance. In addition to the original results obtained by weighing, two independent results of quantitative 1H-NMR have been obtained for further investigation of this reference material together with one additional set of weighing data. The NMR data were used for confirmation of the weighed amount of PET (as weighing is non-specific for PET). Average masses of 0.293 ± 0.04 mg and 0.286 ± 0.03 mg of PET were obtained using two different ultra-microbalances (14% RSD for n = 14 and 9% RSD for n = 4, respectively). The corresponding 1H-NMR data was 0.300 ± 0.02 mg of PET (6.7% RSD for n = 5) and 0.345 ± 0.04 mg of PET (12.5% RSD for n = 14), respectively. The average mass of PET obtained by 1H-NMR measurements was in agreement with the weighed amounts within their standard deviations. A mean value of 0.306 mg PET with an expanded uncertainty of 0.058 mg (± 19% relative) was calculated, and it is traceable to the SI system of measurements. Measurement of PET by quantitative 1H-NMR spectroscopy is also reported for a water sample. The PET contained in one RM sample was transferred to 1 L of water to mimic a drinking water sample for microplastics.

5.
Anal Bioanal Chem ; 414(1): 385-397, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33547482

RESUMO

Validation of analytical methods for measurements of microplastics (MP) is severely hampered because of a general lack of reference materials, RM. There is a great need to develop such reference materials. This study presents a concept of three-component kit with immobilised MP in solid NaCl, a surfactant and clean water that can be applied for the production of many types of MP RMs. As proof of concept, an RM for polyethylene terephthalate (PET) particles in water was prepared and evaluated for its homogeneity. The particles ranged from 30 µm (Feretmin) to about 200 µm adapted by wet sieving. A specific number of PET particles were immobilized in about 0.29 g of solid NaCl by freeze-drying 1 mL of a NaCl suspension. By using manual and automated counting, twenty reconstituted 1-L water samples were evaluated for homogeneity with respect to number of PET particles from 30 µm to > 200 µm/L of water. The number of particles was 730 ± 120 (mean ± one standard deviation (SD); n = 10) and 865 ± 155 particles (n = 10) obtained by optical microscopy in two independent laboratories. This corresponded to relative SDs of 16.4 and 17.9% and a mean of 797 ± 151 particles (18.9% RSD, for n = 20). Homogeneity studies of the NaCl carrier without reconstitution resulted in 794 ± 60 particles (7.5% RSD). The homogeneity of PET in the salt carrier was also evaluated directly with respect to mass of PET per vial using an ultra-micro balance. An average mass of 293 ± 41 µg of PET was obtained (14, % RSD for n = 14). Micrographs were recorded to demonstrate the absence of major sources of contamination of the RM components. Information about the particle size distribution and particle shapes was obtained by laser diffraction (LD) and dynamic image analysis (DIA). In addition, the identity of the PET polymer was confirmed by Raman and FT-IR spectroscopy. The RM was developed for a large-scale inter-laboratory comparison of PET particles in water (ILC). Based on the homogeneity results, the material was found to be sufficiently homogeneous to be of meaningful use in the ILC. In a 3-day process, more than 500 samples of PET particles in the NaCl carrier were prepared with good potential for further upscaling with respect to the number of vials or with other kinds of polymers. The stability of PET was not evaluated but it was deemed to be stable for the duration of the ILC.

6.
Molecules ; 25(6)2020 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-32214034

RESUMO

Explosives detection systems (EDS) based on X-ray are used at airports to screen baggage for the presence of explosives. Once EDS are installed in airports, however, it can be challenging to test the EDS equipment and verify that it continues to perform at the highest level, because of the impracticality of introducing bulk explosives into civil aviation airports. The problem is particularly acute for sensitive homemade explosives, such as triacetone triperoxide (TATP). This paper describes our work to develop a safe, accurate and stable simulant for TATP for EDS based on X-ray transmission. Bulk quantities of TATP were synthesised and characterised especially for this project, and we describe the unique challenges and safety considerations of collecting this data. Our calculations show that the expanded measurement uncertainty with a coverage factor of k = 2 is 5.7% for bulk density and 1.0% for Zeff at 24 months.


Assuntos
Compostos Heterocíclicos com 1 Anel/química , Peróxidos/química , Raios X
7.
Anal Bioanal Chem ; 409(30): 7121-7131, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28971237

RESUMO

A reference material of a PM2.5-like atmospheric dust material has been prepared using a newly developed method. It is intended to certify values for the mass fraction of SO42-, NO3-, Cl- (anions) and Na+, K+, NH4+, Ca2+, Mg2+ (cations) in this material. A successful route for the preparation of the candidate reference material is described alongside with two alternative approaches that were abandoned. First, a PM10-like suspension was allowed to stand for 72 h. Next, 90% of the volume was siphoned off. The suspension was spiked with appropriate levels of the desired ions just prior to drop-wise shock-freezing in liquid nitrogen. Finally, freeze drying of the resulting ice kernels took place. In using this approach, it was possible to produce about 500 g of PM2.5-like material with appropriate characteristics. Fine dust in 150-mg portions was filled into vials under an inert atmosphere. The final candidate material approaches the EN12341 standard of a PM2.5-material containing the ions mentioned in Directive 2008/50/EC of the European Union. The material should be analysed using the CEN/TR 16269:2011 method for anions and cations in PM2.5 collected on filters. The method described here is a relatively rapid means to obtain large quantities of PM2.5. With access to smaller freeze dryers, still 5 to 10 g per freeze-drying cycle can be obtained. Access to such quantities of PM2.5-like material could potentially be used for different kinds of experiments when performing research in this field. Graphical abstract The novelty of the method lies in transformation of a suspension with fine particulate matter to a homogeneous and stable powder with characteristics similar to air-sampled PM2,5. The high material yield in a relatively short time is a distinct advantage in comparison with collection of air-sampled PM2,5.

8.
Anal Bioanal Chem ; 407(11): 3083-91, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25627789

RESUMO

The feasibility of the production of a reference material for pesticide residue analysis in a cucumber matrix was investigated. Cucumber was spiked at 0.075 mg/kg with each of the 15 selected pesticides (acetamiprid, azoxystrobin, carbendazim, chlorpyrifos, cypermethrin, diazinon, (α + ß)-endosulfan, fenitrothion, imazalil, imidacloprid, iprodione, malathion, methomyl, tebuconazole and thiabendazole) respectively. Three different strategies were considered for processing the material, based on the physicochemical properties of the vegetable and the target pesticides. As a result, a frozen spiked slurry of fresh cucumber, a spiked freeze-dried cucumber powder and a freeze-dried cucumber powder spiked by spraying the powder were studied. The effects of processing and aspects related to the reconstitution of the material were evaluated by monitoring the pesticide levels in the three materials. Two separate analytical methods based on LC-MS/MS and GC-MS/MS were developed and validated in-house. The spiked freeze-dried cucumber powder was selected as the most feasible material and more exhaustive studies on homogeneity and stability of the pesticide residues in the matrix were carried out. The results suggested that the between-unit homogeneity was satisfactory with a sample intake of dried material as low as 0.1 g. A 9-week isochronous stability study was undertaken at -20 °C, 4 °C and 18 °C, with -70 °C designated as the reference temperature. The pesticides tested exhibited adequate stability at -20 °C during the 9-week period as well as at -70 °C for a period of 18 months. These results constitute a good basis for the development of a new candidate reference material for selected pesticides in a cucumber matrix.


Assuntos
Cucumis sativus/química , Análise de Alimentos/normas , Contaminação de Alimentos/análise , Resíduos de Praguicidas/análise , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Estudos de Viabilidade , Análise de Alimentos/métodos , Liofilização , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa-Espectrometria de Massas/normas , Resíduos de Praguicidas/normas , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas
9.
Anal Bioanal Chem ; 406(16): 3895-907, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24390460

RESUMO

A set of four reference materials for the detection and quantification of silica nanoparticles (NPs) in food was produced as a proof of principle exercise. Neat silica suspensions were ampouled, tested for homogeneity and stability, and characterized for total silica content as well as particle diameter by dynamic light scattering (DLS), electron microscopy (EM), gas-phase electrophoretic molecular mobility analysis (GEMMA), and field-flow fractionation coupled with an inductively coupled mass spectrometer (FFF-ICPMS). Tomato soup was prepared from ingredients free of engineered nanoparticles and was spiked at two concentration levels with the silica NP suspension. Homogeneity of these materials was found sufficient to act as reference materials and the materials are sufficiently stable to allow long-term storage and distribution at ambient temperature, providing proof of principle of the feasibility of producing liquid food reference materials for the detection of nanoparticles. The spiked soups were characterized for particle diameter by EM and FFF-ICPMS (one material only), as well as for the total silica content. Although questions regarding the trueness of the results from EM and FFF-ICPMS procedures remain, the data obtained indicate that even assigning values should eventually be feasible. The materials can therefore be regarded as the first step towards certified reference materials for silica nanoparticles in a food matrix.


Assuntos
Contaminação de Alimentos/análise , Nanopartículas/química , Dióxido de Silício/química , Solanum lycopersicum/química , Espectrometria de Massas , Microscopia Eletrônica de Transmissão , Tamanho da Partícula , Espalhamento de Radiação
10.
Pharmaceutics ; 14(5)2022 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-35631593

RESUMO

The coupling of an infrared (IR) camera to a freeze dryer for monitoring of the temperature of a pharmaceutical formulation (sucrose/mannitol solution, 4:1%, m/m) during freeze-drying has been exploited further. The new development allows monitoring of temperatures simultaneously at the surface as well as vertically, (e.g., in depth) along the side using custom-made cuvettes. The IR camera was placed on the chamber roof of a process-scale freeze dryer. Monitoring of cuvettes containing the formulation took place from above where one side of each cuvette was equipped with a germanium window. The Ge-window was placed next to an IR mirror having a 45° angle. The long-wave infrared radiation (LWIR) coming from the inside of the cuvette was reflected upwards toward the IR camera. Accurate recording of the temperature along the cuvettes' depth profile was therefore possible. Direct imaging from -40 °C to 30 °C took place every 60 s on the surface and on the side with a 2 × 2 mm resolution per IR pixel for 45 h resulting in 2700 thermograms. Results are presented for freeze-drying of a pharmaceutical formulation as a function of time and spatially for the entire side (depth) of the cuvette. As the sublimation process was progressing, the spatial resolution (84 IR pixels for the side-view and 64 pixels for the surface-view) was more than sufficient to reveal lower temperatures deeper down in the material. The results show that the pharmaceutical formulation (a true solution at the onset) dries irregularly and that the sublimation front does not progress evenly through the material. During secondary drying, potential evaporative cooling of upper layers could be detected thanks to the high thermal and spatial resolution.

11.
Artigo em Inglês | MEDLINE | ID: mdl-31009319

RESUMO

A proficiency testing (PT) round dedicated to assess the competence of European Union (EU) National Reference Laboratories (NRLs), EU Official Control Laboratories (OCLs) and OCLs from associated countries for the determination of the insecticide fipronil in eggs is described. The content of the target analytes (sum of fipronil plus its metabolite fipronil sulfone, expressed as fipronil in the PT test material) was set around the regulated Maximum Residue Level (MRL) set by EU legislation. The PT was organised by the European Commission's (EC) Directorate General (DG) Joint Research Centre (JRC) - in agreement with the EC DG for Health and Food Safety (SANTE) - following a request by the Belgian Authorities. Eighty-six NRLs and OCLs from 22 EU Member States, Norway, Serbia and Albania participated. The test items used were two materials made of frozen liquid eggs, processed and characterised at the JRC facilities in Geel (Belgium). The majority of the participants (94%) were shown to have a satisfactory performance, expressed as z scores, thus demonstrating the analytical capability of most of the participating NRLs and OCLs to enforce the relevant EU Regulations ((EC) 396/2005 and 1127/2014). Furthermore, 93% of the participants who provided a compliance statement classified, correctly, one of the test items as non-compliant.


Assuntos
Ovos/análise , Análise de Alimentos , Contaminação de Alimentos/análise , Laboratórios/normas , Ensaio de Proficiência Laboratorial , Pirazóis/análise , União Europeia , Inocuidade dos Alimentos , Humanos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa