Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Dentomaxillofac Radiol ; 53(6): 382-389, 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-38775663

RESUMO

OBJECTIVE: This study aims to develop a facial vascular enhancement imaging system and analyze vascular distribution in the facial region to assess its potential in preventing unintended intravascular injections during cosmetic facial filling procedures. METHODS: A facial vascular enhancement imaging system based on optical detection technology was designed, and volunteers were recruited. The system was utilized to detect and analyze vascular distribution in various anatomical regions of the faces. The vascular visualization-enhanced (VVE) images generated by the system were compared with visible light images to validate the vascular visualization capability of the system. Additionally, the reliability of vascular visualization was assessed by comparing the observed vascular patterns in the VVE images with those in near-infrared light images. RESULTS: Thirty volunteers were recruited. The VVE images produced by the system demonstrated a significant capacity to identify vascular morphology and yielded a higher vessel count compared to visible light images, particularly in the frontal, orbital, perioral, mental, temporal, cheek, and parotid masseter regions (P < .05). The temporal region exhibited the highest vascular density, followed by the cheek region and then the frontal region. Reliability analysis of vascular visualization enhancement indicated that the system's imaging of facial vasculature not only demonstrated reliability but also enhanced physicians' visual perception. CONCLUSION: Blood vessel distribution varies across facial regions. The facial vascular enhancement imaging system facilitates real-time and clear visualization of facial vasculature, offering immediate visual feedback to surgeons. This innovation holds promise for enhancing the safety and effectiveness of facial filling procedures.


Assuntos
Face , Humanos , Face/diagnóstico por imagem , Face/irrigação sanguínea , Feminino , Adulto , Masculino , Reprodutibilidade dos Testes , Aumento da Imagem/métodos , Técnicas Cosméticas , Imagem Óptica/métodos , Adulto Jovem
2.
J Nanobiotechnology ; 20(1): 343, 2022 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-35883146

RESUMO

BACKGROUND: Promoting diabetic wound healing is still a challenge, and angiogenesis is believed to be essential for diabetic wound healing. Vermiculite is a natural clay material that is very easy to obtain and exhibits excellent properties of releasing bioactive ions, buffering pH, adsorption, and heat insulation. However, there are still many unsolved difficulties in obtaining two-dimensional vermiculite and using it in the biomedical field in a suitable form. RESULTS: In this study, we present a versatile organic-inorganic composite scaffold, which was constructed by embedding two-dimensional vermiculite nanosheets in polycaprolactone electrospun fibers, for enhancing angiogenesis through activation of the HIF-1α signaling pathway and promoting diabetic wound healing both in vitro and in vivo. CONCLUSIONS: Together, the rational-designed polycaprolactone electrospun fibers-based composite scaffolds integrated with two-dimensional vermiculite nanosheets could significantly improve neo-vascularization, re-epithelialization, and collagen formation in the diabetic wound bed, thus promoting diabetic wound healing. This study provides a new strategy for constructing bioactive materials for highly efficient diabetic wound healing.


Assuntos
Diabetes Mellitus , Alicerces Teciduais , Humanos , Poliésteres/química , Alicerces Teciduais/química , Cicatrização
3.
J Craniofac Surg ; 33(7): e685-e688, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35275856

RESUMO

PURPOSE: This study aimed to introduce an innovative method for mandibular condylectomy. A customized three-dimensional (3D) printed template is used to perform precise condylectomy in an intraoral approach. METHODS: Condylectomy combined with orthognathic surgery was used for the treatment of facial asymmetry secondary to unilateral condylar hyperplasia. The customized 3D printed osteotomy guide was placed with an intraoral approach under endoscopy, in order to perform a precise condylectomy. RESULT: With the customized 3D printed template, the condylectomy was performed more precisely, and the conventional extraoral incision was avoided. The osteotomy line was accurately transferred from the virtual surgical plan to the real surgery, which assured the precise resection. CONCLUSIONS: The intraoral approach combined with a 3D printed template provides a novel solution to perform the condylectomy precisely.


Assuntos
Má Oclusão , Procedimentos Cirúrgicos Ortognáticos , Assimetria Facial/diagnóstico por imagem , Assimetria Facial/patologia , Assimetria Facial/cirurgia , Humanos , Hiperplasia/patologia , Hiperplasia/cirurgia , Má Oclusão/patologia , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/patologia , Côndilo Mandibular/cirurgia , Procedimentos Cirúrgicos Ortognáticos/métodos
4.
J Craniofac Surg ; 31(8): 2324-2328, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33136882

RESUMO

OBJECTIVE: Orthognathic surgery is an effective method to correct the dentomaxillofacial deformities. The aim of the study is to introduce the robot-assisted orthognathic surgery and demonstrate the accuracy and feasibility of robot-assisted osteotomy in transferring the preoperative virtual surgical planning (VSP) into the intraoperative phase. METHODS: The CMF robot system, a craniomaxillofacial surgical robot system was developed, consisted of a robotic arm with 6 degrees of freedom, a self-developed end-effector, and an optical localizer. The individualized end-effector was installed with reciprocating saw so that it could perform osteotomy. The study included control and experimental groups. In control group, under the guidance of navigation system, surgeon performed the osteotomies on 3 skull models. In experimental group, according to the preoperative VSP, the robot completed the osteotomies on 3 skull models automatically with assistance of navigation. Statistical analysis was carried out to evaluate the accuracy and feasibility of robot-assisted orthognathic surgery and compare the errors between robot-assisted automatic osteotomy and navigation-assisted manual osteotomy. RESULTS: All the osteotomies were successfully completed. The overall osteotomy error was 1.07 ±â€Š0.19 mm in the control group, and 1.12 ±â€Š0.20 mm in the experimental group. No significant difference in osteotomy errors was found in the robot-assisted osteotomy groups (P = 0.353). There was consistence of errors between robot-assisted automatic osteotomy and navigation-assisted manual osteotomy. CONCLUSION: In robot-assisted orthognathic surgery, the robot can complete an osteotomy according to the preoperative VSP and transfer a preoperative VSP into the actual surgical operation with good accuracy and feasibility.


Assuntos
Procedimentos Cirúrgicos Ortognáticos , Procedimentos Cirúrgicos Robóticos , Humanos , Erros Médicos , Procedimentos Cirúrgicos Ortognáticos/métodos , Crânio , Software
5.
J Oral Maxillofac Surg ; 76(5): 1026-1035, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29360456

RESUMO

PURPOSE: In response to the increased attention to soft tissue reduction in the treatment of intracapsular condylar fractures (ICFs), a modified open reduction technique is proposed and its functional and radiographic outcomes were evaluated in this study. PATIENTS AND METHODS: This is a retrospective case series study of patients with all ICF types that were treated with open reduction and internal fixation (ORIF) with articular disc anatomic reduction and rigid anchorage. Inclusion and exclusion criteria were strictly applied. Preoperative and postoperative clinical examinations of malocclusion, maximum incisor opening (MIO), laterotrusion, and temporomandibular disorder symptoms were recorded and analyzed. Computed tomography (CT) and magnetic resonance imaging (MRI) were used to assess articular position and condylar morphology and position. RESULTS: Thirty-four patients with ICFs (47 sides) were treated with the modified ORIF technique. At 6 months of follow-up, no malocclusion was found and the MIO considerably expanded to 3.56 ± 0.13 cm. Only 4 patients (12%) had temporomandibular joint discomfort with mouth opening. Interestingly, for unilateral type B ICFs, the laterotrusion distance to the ORIF sides was notably longer than to the non-ORIF sides. Postoperative CT and MRI showed that all fragments were properly reduced and the condyles were in the normal position. Postoperative anterior disc displacement occurred in 4 sides and condylar morphologic abnormalities (slight surface roughening and articular cartilage absorption) occurred in 3 sides (6.4%). CONCLUSIONS: This modified ORIF technique, which achieved good outcomes after treatment of all ICF types, shows promise for the treatment of ICFs.


Assuntos
Fixação Interna de Fraturas/métodos , Cápsula Articular/lesões , Côndilo Mandibular/lesões , Fraturas Mandibulares/cirurgia , Redução Aberta/métodos , Articulação Temporomandibular/lesões , Adolescente , Adulto , Idoso , Feminino , Seguimentos , Humanos , Cápsula Articular/cirurgia , Masculino , Côndilo Mandibular/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Articulação Temporomandibular/cirurgia , Resultado do Tratamento , Adulto Jovem
6.
J Craniofac Surg ; 26(8): e746-9, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26594995

RESUMO

PURPOSE: The authors aimed to develop 1 novel navigation-guided robotic system for craniofacial surgery to improve accuracy during operation. MATERIALS AND METHODS: A new 7-DOF (7-degree-of-freedom) robotic arm was designed and manufactured. Based on our self-developed navigation system TBNAVIS-CMFS, the key technique of integration was studied. A phantom skull model was manufactured based on computed tomography image data and used for the preexperimental study. Firstly, virtual planning was achieved through the TBNAVIS-CMFS, where the Le Fort I procedure was executed through simulation. Then, the actual Le Fort 1 osteotomy was expected to perform with the use of the robotic arm following the instructions from the navigation system. RESULTS: The theoretical prototype of navigation-guided robotic system for craniofacial surgery was established successfully, which performed the planned Le Fort I procedure with the whole process visible on the screen. CONCLUSIONS: The technical method of navigation-guided robotics system, allowing the operator to practice the virtual planning procedure through navigation system as well as perform the actual operation thru the robotic arm, could be regarded as a valuable option for benefiting craniofacial surgeons.


Assuntos
Ossos Faciais/cirurgia , Osteotomia/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Crânio/cirurgia , Simulação por Computador , Humanos , Modelos Anatômicos , Duração da Cirurgia , Osteotomia de Le Fort/métodos , Planejamento de Assistência ao Paciente , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador
7.
J Craniofac Surg ; 26(7): 2115-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26468793

RESUMO

PURPOSE: The aims of this study were to present our experience in the use of the mirroring tool in computer-aided simulation (CAS) as well as to describe its diversified uses and indications systematically. MATERIALS AND METHODS: Between 2006 and 2012, 144 patients underwent preoperative CAS with mirroring tool developed by our department called Accu-Navi System. Various mirroring methods were performed and classified systemically. The outcome was evaluated thru its performance intraoperatively and the results postoperatively. RESULTS: The optimal preoperative plans were achieved for all 144 patients using the mirroring tool. This provided the surgeon with accurate surgical information preoperatively and intraoperatively. There were 138 operations performed based on the preoperative plan. The duration of the operations was significantly shortened with improved surgical accuracy and safety. The mean discrepancy was confirmed to be less than 1.0 mm by comparing postoperative computed tomography with the preoperative plan. Postoperative esthetics improved remarkably along with patients' satisfaction without complications thru long-term follow-up evaluations. CONCLUSIONS: The mirroring tool with its many uses can be a valuable CAS procedure for craniofacial surgery.


Assuntos
Simulação por Computador , Planejamento de Assistência ao Paciente , Procedimentos de Cirurgia Plástica/métodos , Cirurgia Assistida por Computador/métodos , Adolescente , Adulto , Anquilose/cirurgia , Anormalidades Craniofaciais/cirurgia , Estética , Feminino , Displasia Fibrosa Óssea/cirurgia , Seguimentos , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Cuidados Intraoperatórios , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Segurança do Paciente , Satisfação do Paciente , Fraturas Cranianas/cirurgia , Transtornos da Articulação Temporomandibular/cirurgia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Adulto Jovem
8.
J Craniofac Surg ; 26(2): e122-4, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25710741

RESUMO

PURPOSE: It is unusual to see a metallic foreign body having stayed at the temporal surface of the sphenoid greater wing for 2 decades. Because of the change of proximity anatomy and the difficult access to delicate structure, removal of this foreign body seemed challenging. The application of surgical navigation system combined with endoscopy from other directions could reduce damage to the surrounding tissues during the removal and lower the risk. RESULTS: Computed tomographic scan on the head indicated that finalposition was the temporal surface of the sphenoid greater wing posterior to the lateral orbital wall. To relieve the patient from sustaining pain caused by the metallic foreign body, surgical navigation system combined with endoscopy was adopted to remove the foreign body. Two different incisions were made to place the probe of the navigation and the endoscope respectively, in which way we could get a better view of the anatomic structures when reaching the metallic foreign body. The patient's problem was solved safely and efficiently. No sequela was observed. CONCLUSIONS: In case of complicated anatomic structure, surgical navigation system combined with endoscopy from another direction proved to be a practical and safe method to remove foreign bodies.


Assuntos
Endoscopia/métodos , Corpos Estranhos/cirurgia , Órbita/lesões , Osso Esfenoide/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X
9.
J Oral Maxillofac Surg ; 72(4): 764-72, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24635855

RESUMO

PURPOSE: In surgery-first accelerated orthognathic surgery, the clinical phenomenon of accelerated orthodontic tooth movement after osteotomy is a benefit compared with the conventional approach. However, because much of the literature on this phenomenon is based on empirical evidence and case reports, experimental animal-based studies are needed to verify and quantify this acceleration effect. The purpose of this prospective experimental study was to identify whether osteotomy procedures increase tooth movement. MATERIAL AND METHODS: Le Fort I osteotomies were performed on the left maxillas in 15 male adult Sprague-Dawley rats. After surgery, a continuous force of 0.5 N was placed on the maxillary left first molar to move the tooth mesially. Another 15 rats had no surgery and served as controls. On days 1, 14, and 28, digital caliper measurements were taken to record tooth movement. RESULTS: In the experimental group, the maxillary left first molars moved significantly more rapidly on days 14 and 28 (P < .05). Histologic findings showed more active alveolar bone remodeling. CONCLUSION: Le Fort I osteotomy significantly accelerated the rate of orthodontic tooth movement. Histologically, more active and extensive bone remodeling was observed after osteotomy.


Assuntos
Maxila/cirurgia , Osteotomia de Le Fort/métodos , Técnicas de Movimentação Dentária/métodos , Fosfatase Ácida/análise , Processo Alveolar/fisiologia , Animais , Biomarcadores/análise , Fenômenos Biomecânicos , Remodelação Óssea/fisiologia , Reabsorção Óssea/patologia , Ligas Dentárias/química , Isoenzimas/análise , Masculino , Maxila/fisiologia , Modelos Animais , Dente Molar/anatomia & histologia , Níquel/química , Fios Ortodônticos , Osteoclastos/fisiologia , Ligamento Periodontal/anatomia & histologia , Piezocirurgia/métodos , Ratos , Ratos Sprague-Dawley , Estresse Mecânico , Fosfatase Ácida Resistente a Tartarato , Fatores de Tempo , Titânio/química , Técnicas de Movimentação Dentária/instrumentação
10.
J Oral Maxillofac Surg ; 72(1): 128-38, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24095006

RESUMO

PURPOSE: This article presents a novel method of navigation-guided lateral gap arthroplasty (LGA) in the treatment of temporomandibular joint ankylosis (TMJA). MATERIALS AND METHODS: Six patients with unilateral TMJA from 2007 through 2011 were included in this study. Presurgical planning was performed to determine the amount and extent of ankylosed bone to be resected using the simulation platform. Minimum follow-up was 6 months. Patients were monitored for complications and signs of recurrence. Maximum mouth opening (MO) was measured and compared intra- and postoperatively. RESULTS: Preoperative planning was performed at the STN or Accu-Navi workstation. The amount and extent of ankylosed bone to be resected was determined. All 6 LGAs were completed successfully using real-time instrument- and pointer-based navigation. Measurements performed intraoperatively showed that the mean for maximum MO was about 35 to 40 mm and remained the same postoperatively. Follow-up evaluation showed remarkable improvement in function and esthetics, with no signs of recurrence. CONCLUSION: Navigation-guided LGA can be regarded a viable option for performing this delicate and complicated surgical procedure.


Assuntos
Anquilose/cirurgia , Artroplastia/métodos , Cirurgia Assistida por Computador/métodos , Transtornos da Articulação Temporomandibular/cirurgia , Adolescente , Adulto , Pontos de Referência Anatômicos/anatomia & histologia , Anquilose/etiologia , Simulação por Computador , Feminino , Seguimentos , Humanos , Cuidados Intraoperatórios , Masculino , Côndilo Mandibular/lesões , Fraturas Mandibulares/complicações , Modelos Anatômicos , Planejamento de Assistência ao Paciente , Modalidades de Fisioterapia , Complicações Pós-Operatórias , Amplitude de Movimento Articular/fisiologia , Recidiva , Transtornos da Articulação Temporomandibular/etiologia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento , Interface Usuário-Computador , Adulto Jovem
11.
Acta Biochim Biophys Sin (Shanghai) ; 46(7): 572-81, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24850303

RESUMO

Previous studies have shown that using ZrO2 as a second phase to bioceramics can significantly increase the bonding strength of plasma-sprayed composite material. In the present study, micro-roughened titanium dioxide/zirconia (TiO2/ZrO2) (30 wt% ZrO2) coating and TiO2 coating were plasma-sprayed onto Ti plates. The micro-structural characteristics and mechanical properties of both coatings were investigated. Furthermore, the biological behavior and osteogenic differentiation of human bone marrow mesenchymal stem cells (HBMSCs) on both TiO2/ZrO2 and TiO2 coatings were compared. The results indicated that the shear bond strength and microhardness of TiO2/ZrO2 coating were statistically higher than those of TiO2 coating. Scanning electron microscope observation revealed that more irregularly shaped protuberances and denser pores were formed on the surface of TiO2/ZrO2 coating compared with those of TiO2 coating. Further comparative analysis of HBMSC proliferation and osteogenic differentiation on both coatings showed that significantly higher cellular alkaline phosphatase activity and expression levels of Runx2 and Osterix at day 10 after osteogenic culture were found on TiO2/ZrO2 coating compared with TiO2 coating, while no statistically significant difference in cell proliferation and extracellular calcium deposition was observed. The present study suggests that TiO2/ZrO2 coating may be favorable for dental implant applications.


Assuntos
Materiais Biocompatíveis , Células-Tronco Hematopoéticas/citologia , Teste de Materiais , Titânio/química , Zircônio/química , Sequência de Bases , Diferenciação Celular , Células Cultivadas , Primers do DNA , Humanos , Osteogênese , Reação em Cadeia da Polimerase em Tempo Real , Propriedades de Superfície
12.
J Craniofac Surg ; 25(2): 406-11, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24561364

RESUMO

In bimaxillary orthognathic surgery, the positioning of the maxilla and the mandible is typically accomplished via 2-splint technique, which may be the sources of several types of inaccuracy. To overcome the limitations of the 2-splint technique, we developed a new navigation method, which guided the surgeon to free-hand reposition the maxillomandibular complex as a whole intraoperatively, without the intermediate splint. In this preliminary study, the feasibility was demonstrated. Five patients with dental maxillofacial deformities were enrolled. Before the surgery, 3-dimensional planning was conducted and imported into a navigation system. During the operation, a tracker was connected to the osteotomized maxillomandibular complex via a splint. The navigation system tracked the movement of the complex and displayed it on the screen in real time to guide the surgeon to reposition the complex. The postoperative result was compared with the plan by analyzing the measured distances between the maxillary landmarks and reference planes, as determined from computed tomography data. The mean absolute errors of the maxillary position were clinically acceptable (<1.0 mm). Preoperative preparation time was reduced to 100 minutes on average. All patients were satisfied with the aesthetic results. This navigation method without intraoperative image registration provided a feasible means of transferring virtual planning to the real orthognathic surgery. The real-time position of the maxillomandibular complex was displayed on a monitor to visually guide the surgeon to reposition the complex. In this method, the traditional model surgery and the intermediate splint were discarded, and the preoperative preparation was simplified.


Assuntos
Desenho Assistido por Computador , Mandíbula/cirurgia , Maxila/cirurgia , Anormalidades Maxilofaciais/cirurgia , Procedimentos Cirúrgicos Ortognáticos/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Planejamento de Assistência ao Paciente , Satisfação do Paciente , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Cranio ; 32(1): 63-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24660649

RESUMO

BACKGROUND: Dislocation of the mandibular condyle into the middle cranial fossa is rare in clinics. It often occurs when the mouth is open wide during the injury. It causes restriction of mandibular motion, lower facial asymmetry, pain in the temporomandibular joint (TMJ), etc. OBJECTIVE: To introduce the features of intracranial mandibular condyle dislocation and discuss the management to this kind of trauma. MAJOR FINDINGS: In this paper, the authors present two cases, describing the diagnosis, surgical management, and 1-year follow-up evaluation. The results of the authors' treatment to intracranial mandibular condyle dislocation were satisfactory and stable, and no surgical complications were detected. CONCLUSION: Advanced imaging studies are mandatory for exact diagnosis and successful treatment of intracranial mandibular condyle dislocation, and individualized management is recommended.


Assuntos
Fossa Craniana Média/lesões , Luxações Articulares/cirurgia , Côndilo Mandibular/lesões , Articulação Temporomandibular/lesões , Articulação Temporomandibular/cirurgia , Adulto , Fossa Craniana Média/cirurgia , Feminino , Humanos , Luxações Articulares/diagnóstico por imagem , Luxações Articulares/etiologia , Masculino , Côndilo Mandibular/diagnóstico por imagem , Côndilo Mandibular/cirurgia , Traumatismos Mandibulares/diagnóstico por imagem , Traumatismos Mandibulares/cirurgia , Articulação Temporomandibular/diagnóstico por imagem , Disco da Articulação Temporomandibular/diagnóstico por imagem , Disco da Articulação Temporomandibular/lesões , Disco da Articulação Temporomandibular/cirurgia , Tomografia Computadorizada por Raios X , Adulto Jovem
14.
Head Face Med ; 20(1): 51, 2024 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-39306659

RESUMO

BACKGROUND: Successfully restoring facial contours continues to pose a significant challenge for surgeons. This study aims to utilize head-mounted display-based augmented reality (AR) navigation technology for facial soft tissue defect reconstruction and to evaluate its accuracy and effectiveness, exploring its feasibility in craniofacial surgery. METHODS: Hololens 2 was utilized to construct the AR guidance system for facial fat grafting. Twenty artificial cases with facial soft tissue defects were randomly assigned to Group A and Group B, undergoing filling surgeries with the AR guidance system and conventional methods, respectively. All postoperative three-dimensional models were superimposed onto virtual plans to evaluate the accuracy of the system versus conventional filling methods. Additionally, procedure completion time was recorded to assess system efficiency relative to conventional methods. RESULTS: The error in facial soft tissue defect reconstruction assisted by the system in Group A was 2.09 ± 0.56 mm, significantly lower than the 3.23 ± 1.15 mm observed with conventional methods in Group B (p < 0.05). Additionally, the time required for facial defect filling reconstruction using the system in Group A was 25.45 ± 2.58 min, markedly shorter than the 37.05 ± 3.34 min needed with conventional methods in Group B (p < 0.05). CONCLUSION: The visual navigation offered by the fat grafting AR guidance system presents obvious advantages in facial soft tissue defect reconstruction, facilitating enhanced precision and efficiency in these filling procedures.


Assuntos
Tecido Adiposo , Realidade Aumentada , Procedimentos de Cirurgia Plástica , Humanos , Tecido Adiposo/transplante , Procedimentos de Cirurgia Plástica/métodos , Feminino , Masculino , Cirurgia Assistida por Computador/métodos , Face/cirurgia , Face/diagnóstico por imagem , Lesões dos Tecidos Moles/cirurgia , Imageamento Tridimensional , Adulto
15.
Acta Biomater ; 177: 486-505, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38311197

RESUMO

Bone repair in elderly patients poses a huge challenge due to the age-related progressive decline in regenerative abilities attributed to the senescence of bone marrow stem cells (BMSCs). Bioactive scaffolds have been applied in bone regeneration due to their various biological functions. In this study, we aimed to fabricate functionalized bioactive scaffolds through loading osteoinductive extracellular vesicles (OI-EVs) based on mesoporous bioactive glass (MBG) scaffolds (1010 particles/scaffold) and to investigate its effects on osteogenesis and senescence of BMSCs. The results suggested that OI-EVs upregulate the proliferative and osteogenic capacities of senescent BMSCs. More importantly, The results showed that loading OI-EVs into MBG scaffolds achieved better bone regeneration. Furthermore, OI-EVs and BMSCs RNAs bioinformatics analysis indicated that OI-EVs play roles through transporting pivotal lncRNA acting as a "sponge" to compete with Mob3a for miR-1843a-5p to promote YAP dephosphorylation and nuclear translocation, ultimately resulting in elevated proliferation and osteogenic differentiation and reduced senescence-related phenotypes. Collectively, these results suggested that the OI-EVs lncRNA ceRNA regulatory networks might be the key point for senescent osteogenesis. More importantly, the study indicated the feasibility of loading OI-EVs into scaffolds and provided novel insights into biomaterial design for facilitating bone regeneration in the treatment of senescent bone defects. STATEMENT OF SIGNIFICANCE: Constructing OI-EVs/MBG delivering system and verification of its bone regeneration enhancement in senescent defect repair. Aging bone repair poses a huge challenge due to the age-related progressive degenerative decline in regenerative abilities attributed to the senescence of BMSCs. OI-EVs/MBG delivering system were expected as promising treatment for senescent bone repair, which could provide an effective strategy for bone regeneration in elderly patients. Clarification of potential OI-EVs lncRNA ceRNA regulatory mechanism in senescent bone regeneration OI-EVs play important roles through transferring lncRNA-ENSRNOG00000056625 sponging miR-1843a-5p that targeted Mob3a to activate YAP translocation into nucleus, ultimately alleviate senescence, promote proliferation and osteogenic differentiation in O-BMSCs, which provides theoretical basis for EVs-mediated therapy in future clinical works.


Assuntos
Vesículas Extracelulares , MicroRNAs , RNA Longo não Codificante , Humanos , Idoso , Osteogênese , Alicerces Teciduais , RNA Longo não Codificante/genética , Regeneração Óssea , Diferenciação Celular , MicroRNAs/genética , Células da Medula Óssea , Vidro
16.
J Oral Maxillofac Surg ; 71(9): 1563-71, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23810618

RESUMO

PURPOSE: Most trauma surgeons encounter numerous penetrating injuries. Some foreign bodies can cause pain, infection, and discomfort to the patient. Serious functional disorders also are likely to occur. Foreign bodies in critical areas must be removed. This report describes the use of image-guided technology for the removal of foreign bodies deep in the maxillofacial region. PATIENTS AND METHODS: From 2008 through 2011, 5 patients with foreign bodies in the maxillofacial area underwent image-guided removal at the authors' department. The STN navigation system (Stryker-Leibinger, Freiburg, Germany) was used for surgical planning and intraoperative navigation. Preoperatively, computerized tomography and digital subtraction angiography were used to create 3-dimensional views of the region to aid surgeons in more accurately defining the spatial location of the foreign object. During surgery, the foreign objects and surgical instruments were visualized on the screen. RESULTS: In all 5 cases, the foreign bodies were removed by minimally invasive access without any complications. Surgical time was approximately 40% shorter compared with the conventional technique of not using image-guided navigation. A 1-year postoperative evaluation showed that the patients' complaints and symptoms had resolved, function was restored, and esthetics were remarkably improved. CONCLUSION: Navigation-guided removal of foreign bodies in the complex, deep maxillofacial region in proximity to vital areas can be regarded an ideal and valuable option for these potentially complicated procedures.


Assuntos
Corpos Estranhos/cirurgia , Traumatismos Maxilofaciais/cirurgia , Cirurgia Assistida por Computador/métodos , Ferimentos Penetrantes/cirurgia , Adulto , Angiografia Digital/métodos , Artéria Carótida Interna/diagnóstico por imagem , Estética , Feminino , Seguimentos , Humanos , Imageamento Tridimensional/métodos , Cuidados Intraoperatórios , Masculino , Músculo Masseter/lesões , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Duração da Cirurgia , Órbita/lesões , Planejamento de Assistência ao Paciente , Faringe/lesões , Recuperação de Função Fisiológica/fisiologia , Cirurgia Assistida por Computador/instrumentação , Osso Temporal/lesões , Tomografia Computadorizada Espiral/métodos , Adulto Jovem
17.
J Craniofac Surg ; 24(5): 1573-6, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24036729

RESUMO

PURPOSE: The aim of this study was to demonstrate the feasibility of building a craniofacial virtual reality model by image fusion of 3-dimensional (3D) CT models and 3 dMD stereophotogrammetric facial surface. METHODS: A CT scan and stereophotography were performed. The 3D CT models were reconstructed by Materialise Mimics software, and the stereophotogrammetric facial surface was reconstructed by 3 dMD patient software. All 3D CT models were exported as Stereo Lithography file format, and the 3 dMD model was exported as Virtual Reality Modeling Language file format. Image registration and fusion were performed in Mimics software. Genetic algorithm was used for precise image fusion alignment with minimum error. The 3D CT models and the 3 dMD stereophotogrammetric facial surface were finally merged into a single file and displayed using Deep Exploration software. Errors between the CT soft tissue model and 3 dMD facial surface were also analyzed. RESULTS: Virtual model based on CT-3 dMD image fusion clearly showed the photorealistic face and bone structures. Image registration errors in virtual face are mainly located in bilateral cheeks and eyeballs, and the errors are more than 1.5 mm. However, the image fusion of whole point cloud sets of CT and 3 dMD is acceptable with a minimum error that is less than 1 mm. CONCLUSIONS: The ease of use and high reliability of CT-3 dMD image fusion allows the 3D virtual head to be an accurate, realistic, and widespread tool, and has a great benefit to virtual face model.


Assuntos
Simulação por Computador , Anormalidades Craniofaciais/diagnóstico , Imageamento Tridimensional/métodos , Imagem Multimodal/métodos , Fotogrametria , Tomografia Computadorizada por Raios X , Interface Usuário-Computador , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Adulto Jovem
18.
J Craniofac Surg ; 24(2): 405-10, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23524703

RESUMO

PURPOSE: The properties of the biomaterial are normally characterized by heterogeneity on all scales influencing the function and biomechanics. Elastic modulus (EM), which is one of the most important mechanical properties of material, is necessary for finite element modeling and needed to be determined by some methods. The aim of this study is to demonstrate the feasibility of assessment of EM from GrayValue (GV) of computed tomographic image and assignment of material properties in heterogeneous finite element modeling for studying the performance of the mandibular bones. METHODS: Three mandibles obtained from fresh human cadavers were used in this study. All mandibular bones were scanned using computed tomography, and the original data were stored in optical disks. The finite element modeling of the 3 mandibles was meshed using Materialise Mimics 10.01 and Abaqus 6.10 software. Using the empirical expression on relationship between GV and EM, the empirical EM of the meshed mandibular elements were calculated. To verify the empirical EM, actual EM of the three was determined by nanoindentation test using Oliver and Pharr method. The dependence of EM on test regions and loading directions were also discussed. RESULTS: The empirical EM of the mandible element is in the range of 3.7 to 23.4 Gpa, and EM of the cortical element is in the range of 8.6 to 13.6 Gpa. In comparison, the actual EM of cortical bone tested by nanoindentation method is in the range of 10.0 to 22.0 Gpa. The tested EM is varied with the test regions and loading directions. The difference in the values of EM determined by the empirical analysis and by the nanoindentation test is approximately 5.0 Gpa. CONCLUSIONS: A mandibular finite element model with heterogeneous material properties is built. By analyzing the EM value of this model, it is concluded that the actual EM in anterior-posterior direction in mandibular ramus and EM in superior-inferior direction in mandibular body match the empirical EM better than the other directions.


Assuntos
Módulo de Elasticidade , Análise de Elementos Finitos , Mandíbula/fisiologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Pessoa de Meia-Idade , Software , Tomografia Computadorizada por Raios X
19.
J Craniofac Surg ; 24(6): e573-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24220469

RESUMO

PURPOSE: The authors describe an intraoral approach to accessing the mandibular condyle using endoscopy combined with a navigation system and explore the feasibility of this technique for the precise excision of a benign tumor in the condyle. METHODS: The junction between the osteochondroma and the condyle was recognized and defined as the osteotomy line in a CT-based surgery planning software, and the surgical plan was then exported to a navigation system. A 4-mm-diameter 30-degree endoscope was placed in the wound with direct access to the entire condyle. Based on constant feedback from the navigation system in multiplanar and 3D views, the landmarks of the osteotomy line were identified, and precise tumor resection was achieved. RESULTS: The magnified endoscopic view allowed the condylar head and neck to be easily dissected with good illumination and clear visualization. The landmarks of the osteotomy line were transferred from the virtual surgical plan to the surgical field, and precise resection of the condylar tumor was achieved. CONCLUSION: The combined technique reported in this paper could represent a valid minimally invasive approach to the ramus-condyle unit for direct visualization of the medial aspect of the condyle and precise resection of benign tumor located here.


Assuntos
Endoscopia/métodos , Côndilo Mandibular/cirurgia , Neoplasias Mandibulares/cirurgia , Osteocondroma/cirurgia , Cirurgia Assistida por Computador/métodos , Adulto , Dissecação/instrumentação , Dissecação/métodos , Endoscópios , Estudos de Viabilidade , Feminino , Marcadores Fiduciais , Seguimentos , Humanos , Imageamento Tridimensional/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Osteotomia/métodos , Planejamento de Assistência ao Paciente , Cirurgia Assistida por Computador/instrumentação , Tomografia Computadorizada por Raios X/métodos , Interface Usuário-Computador
20.
J Craniofac Surg ; 24(4): 1215-20, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23851772

RESUMO

Three-dimensional measurement of the pharyngeal airway has been widely used, but the three-dimensional reconstruction of pharyngeal airway has been performed in various ways, especially during the anterior boundary demarcation of the nasopharyngeal airway and oropharyngeal airway. This would inevitably affect the measurement and lead to noncomparison between different studies. Our study provided a novel method for anterior boundary demarcation of pharyngeal airway that defined the anterior boundary of nasopharyngeal airway as the "choana" according to the anatomical definition and defined the anterior boundary of oropharyngeal airway as a plane perpendicular to the long axis of soft palate and through the intersections of the lateral space and inferior space to soft palate according to the physiologic characteristics of soft palate. By 2-step segmentation, a three-dimensional image of pharyngeal airway was eventually reconstructed.Ten computed tomographic scans of pharyngeal airway were included for the anterior boundary demarcation and three-dimensional reconstruction by a medical imaging software (Surgicase 5.0; Materialise Interactive Medical Image Control System, Leuven, Belgium), with the volume and surface area being calculated. By using intraclass correlation coefficient, the reliability between intra- and interobservers of this method was well tested.The method established in this study for anterior boundary demarcation and three-dimensional reconstruction of pharyngeal airway is highly reliable and could more veritably reflect the intrinsic anatomical characteristics of the pharyngeal airway.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Faringe/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Cefalometria/métodos , Humanos , Osso Nasal/diagnóstico por imagem , Cavidade Nasal/diagnóstico por imagem , Nasofaringe/diagnóstico por imagem , Tamanho do Órgão , Orofaringe/diagnóstico por imagem , Palato Mole/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa