Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
J Nucl Cardiol ; 21(3): 478-85, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24477404

RESUMO

PURPOSE: We have assessed whether additional upright imaging increases the confidence of interpretation of stress only supine myocardial perfusion imaging (MPI) in obese patients. METHODS AND RESULTS: Tc-MIBI stress MPI of 101 consecutive patients (M = 49, 62 ± 12 years) with BMI ≥30 scanned on the D-SPECT cardiac camera were assessed. Images were interpreted as diagnostic or equivocal and the need for a rest study was recorded. Stress supine MPI was interpreted first, then gated and finally upright data were added. Defects on supine but not on upright were defined as artefacts and defects seen on both as abnormal. The total perfusion deficit (TPD) was also quantified. There were 27 normal, 22 abnormal, and 52 equivocal supine scans. The median EF was 52%, unaffecting the need for rest imaging. Upright imaging reclassified 32/52 (62%) equivocal studies as normal and 6/52 (11%) as abnormal (P < 0.001). Rest scan was deemed needed in 74/101 patients on supine vs 42/101 on supine/upright (P < 0.001). Supine TPD was normal in 53 and supine/upright TPD was normal in 70 patients (P < 0.001). CONCLUSION: Supine stress MPI is inadequate in obese patients. The addition of upright imaging significantly increases the ability to interpret scans as diagnostic and may reduce considerably the need for rest imaging.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imagem de Perfusão do Miocárdio/instrumentação , Obesidade/diagnóstico por imagem , Posicionamento do Paciente/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/complicações , Dobutamina , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Decúbito Dorsal , Vasodilatadores
2.
Eur J Nucl Med Mol Imaging ; 40(7): 1084-94, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23595108

RESUMO

PURPOSE: High-speed (HS) single-photon emission computed tomography (SPECT) with a recently developed solid-state camera shows comparable myocardial perfusion abnormalities to those seen in conventional SPECT. We aimed to compare HS and conventional SPECT images from multiple centres with coronary angiographic findings. METHODS: The study included 50 patients who had sequential conventional SPECT and HS SPECT myocardial perfusion studies and coronary angiography within 3 months. Stress and rest perfusion images were visually analysed and scored semiquantitatively using a 17-segment model by two experienced blinded readers. Global and coronary territorial summed stress scores (SSS) and summed rest scores (SRS) were calculated. Global SSS ≥3 or coronary territorial SSS ≥2 was considered abnormal. In addition the total perfusion deficit (TPD) was automatically derived. TPD >5% and coronary territorial TPD ≥3% were defined as abnormal. Coronary angiograms were analysed for site and severity of coronary stenosis; ≥50% was considered significant. RESULTS: Of the 50 patients, 13 (26%) had no stenosis, 22 (44%) had single-vessel disease, 6 (12%) had double-vessel disease and 9 (18%) had triple-vessel disease. There was a good linear correlation between the visual global SSS and SRS (Spearman's ρ 0.897 and 0.866, respectively; p < 0.001). In relation to coronary angiography, the sensitivities, specificities and accuracies of HS SPECT and conventional SPECT by visual assessment were 92% (35/38), 83% (10/12) and 90% (45/50) vs. 84% (32/38), 50% (6/12) and 76% (38/50), respectively (p < 0.001). The sensitivities, specificities and accuracies of HS SPECT and conventional SPECT in relation to automated TPD assessment were 89% (31/35), 57% (8/14) and 80% (39/49) vs. 86% (31/36), 77% (10/13) and 84% (41/49), respectively. CONCLUSION: HS SPECT allows fast acquisition of myocardial perfusion images that correlate well with angiographic findings with overall accuracy by visual assessment better than conventional SPECT. Further assessment in a larger patient population may be needed to confirm this observation.


Assuntos
Angiografia Coronária , Imagem de Perfusão do Miocárdio/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa