Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38737316

RESUMO

Chronic pain is a leading cause of morbidity among children and adolescents affecting 35% of the global population. Pediatric chronic pain management requires integrative health methods spanning physical and psychological subsystems through various mind-body interventions. Yoga therapy is one such method, known for its ability to improve the quality of life both physically and psychologically in chronic pain conditions. However, maintaining the clinical outcomes of personalized yoga therapy sessions at-home is challenging due to fear of movement, lack of motivation, and boredom. Virtual Reality (VR) has the potential to bridge the gap between the clinic and home by motivating engagement and mitigating pain-related anxiety or fear of movement. We developed a multi-modal algorithmic architecture for fusing real-time 3D human body pose estimation models with custom developed inverse kinematics models of physical movement to render biomechanically informed 6-DoF whole-body avatars capable of embodying an individual's real-time yoga poses within the VR environment. Experiments conducted among control participants demonstrated superior movement tracking accuracy over existing commercial off-the-shelf avatar tracking solutions, leading to successful embodiment and engagement. These findings demonstrate the feasibility of rendering virtual avatar movements that embody complex physical poses such as those encountered in yoga therapy. The impact of this work moves the field one step closer to an interactive system to facilitate at-home individual or group yoga therapy for children with chronic pain conditions.

2.
Mil Med ; 189(Supplement_3): 677-685, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160802

RESUMO

INTRODUCTION: Musculoskeletal injuries (MSKIs) among active duty soldiers result in more than 10 million limited duty days each year and account for more than 70% of the medically nondeployable population. Overuse injuries in lower limbs from running, foot marching long distances with heavy loads, and lifting heavy objects are the most common types of injuries in the military. Physical training and rehabilitation exercises for greater resiliency through aerobic, muscle strength, endurance, and agility conditioning programs can prevent or reduce the effects of MSKIs if Soldiers adhere to proper biomechanics and training techniques. We are introducing a three-dimensional (3D) camera-based platform for Optical Screening and Conditioning for Injury Resilience (OSCIR) that is designed to identify and correct high-risk movement patterns based on quantifiable biomechanical measurements in clinical or field settings. Our goal is to improve resilience to MSKI by offering greater access to quality of movement skills in warfighters through an autonomous device that can be used in Sports Medicine and Reconditioning Team (SMART) clinics and High-Intensity Tactical Training (HITT) sites. MATERIALS AND METHODS: OSCIR fuses four pairs of Kinect Azure cameras into a concise footprint to achieve suitable sampling rates and an unobstructed field of view for accurate dynamic movement tracking using a custom point cloud solution. We designed a unique multistage 3D joint tracking algorithm architecture to methodically isolate the human body point cloud from the background, identify individual limb segments, and perform iterative joint optimization at the global and local joint levels. We evaluated the feasibility of our prototype system among N = 12 control participants (6 M/6 F; 21-37 years) in compliance with the Western Institutional Review Board (Tracking #20225920, approved on November 4, 2022). Five task-specific MSKI outcome metrics identified by end-user physical therapists and athletic trainers as indicators for movement quality were assessed across 7 lower-extremity exercises derived from standardized MSK assessment/conditioning batteries used in the military. Data were recorded concurrently by OSCIR and a reference standard Vicon motion capture system for validating system accuracy. RESULTS: Task-specific MSKI indicators for knee flexion and hip flexion range of motion achieved an average error of 4.05 ± 2.34°, while 3D position-based postural outcomes of left-right foot distance, left-right hand distance, and step length obtained mean absolute errors of 2.58 ± 2.30 cm. Results support the feasibility of our system in achieving outcomes that are comparable to currently accepted laboratory standards. CONCLUSIONS: Our study describes the integration process for a 3D camera-based clinical system for MSKI conditioning and rehabilitation. The impact of our system will enable key stakeholders in the military to manage MSKIs in warfighters by automating key assessment and rehabilitation test batteries; making tests more readily accessible, and interpretations more accurate by providing objective biomechanical measures. OSCIR is undergoing turn-key design features to serve as a screening tool for warfighters to readily assess susceptibility to MSKI or as a training platform to help guide exercise techniques to achieve resiliency against future injuries.


Assuntos
Militares , Humanos , Militares/estatística & dados numéricos , Militares/psicologia , Fenômenos Biomecânicos
3.
Artigo em Inglês | MEDLINE | ID: mdl-38009078

RESUMO

This study introduces a VR-based breathing and relaxation exergame tailored for individuals with Duchenne muscular dystrophy (DMD). DMD is a rare neuromuscular disease that leads to respiratory muscle dysfunction with anxiety being a common comorbidity. Clinical management requires frequent visits to rare disease specialists to manage symptom progression. Limited availability and/or proximity of rare disease experts present challenges to care and can lead to missed care opportunities and reduced quality of life. We propose a breathing and relaxation exergame with remote telehealth applicability that incorporates shared patient-clinician VR interaction, and physiological sensors that provide both real-time feedback to the patient and health analytics for the clinician. The game focuses on two key aspects of DMD clinical care that can be mediated through control of breathing: relaxation/mindfulness training and respiratory muscle exercise. The system was evaluated among 13 individuals, including 4 participants with DMD. Feedback surveys, interviews, and focus group discussions with participants, accompanying family members, and clinicians demonstrated the feasibility of this VR tool for telehealth or as part of a home exercise program.

4.
J Speech Lang Hear Res ; 64(6S): 2134-2153, 2021 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-33979177

RESUMO

Purpose This study aimed to evaluate a novel communication system designed to translate surface electromyographic (sEMG) signals from articulatory muscles into speech using a personalized, digital voice. The system was evaluated for word recognition, prosodic classification, and listener perception of synthesized speech. Method sEMG signals were recorded from the face and neck as speakers with (n = 4) and without (n = 4) laryngectomy subvocally recited (silently mouthed) a speech corpus comprising 750 phrases (150 phrases with variable phrase-level stress). Corpus tokens were then translated into speech via personalized voice synthesis (n = 8 synthetic voices) and compared against phrases produced by each speaker when using their typical mode of communication (n = 4 natural voices, n = 4 electrolaryngeal [EL] voices). Naïve listeners (n = 12) evaluated synthetic, natural, and EL speech for acceptability and intelligibility in a visual sort-and-rate task, as well as phrasal stress discriminability via a classification mechanism. Results Recorded sEMG signals were processed to translate sEMG muscle activity into lexical content and categorize variations in phrase-level stress, achieving a mean accuracy of 96.3% (SD = 3.10%) and 91.2% (SD = 4.46%), respectively. Synthetic speech was significantly higher in acceptability and intelligibility than EL speech, also leading to greater phrasal stress classification accuracy, whereas natural speech was rated as the most acceptable and intelligible, with the greatest phrasal stress classification accuracy. Conclusion This proof-of-concept study establishes the feasibility of using subvocal sEMG-based alternative communication not only for lexical recognition but also for prosodic communication in healthy individuals, as well as those living with vocal impairments and residual articulatory function. Supplemental Material https://doi.org/10.23641/asha.14558481.


Assuntos
Percepção da Fala , Voz , Eletromiografia , Humanos , Laringectomia , Fala , Inteligibilidade da Fala
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa