Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
BMC Pediatr ; 23(1): 293, 2023 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-37322472

RESUMO

BACKGROUND: Foramen ovale (FO) is an obligate fetal shunt that typically resolves after birth, although patency throughout life is not uncommon. The natural history of patent FO (PFO) is known in term infants, but less is known about its course in extremely preterm infants. We describe the echocardiographic changes in FO size from birth to discharge in extremely low birth weight (ELBW) infants in this retrospective study. METHODS: Cohort was divided based on size of FO at birth. Size of FO at discharge was measured and evaluated relative to postnatal weight gain. Demographics and clinical outcomes were compared between the two groups. RESULTS: Of the 54 ELBW infants, 50 were born with FO less than 3 mm in diameter (small), and 4 were born with FO greater than 3 mm (large). Of small defects, the majority (44/50, 88%) did not increase in size with weight gain, and minority (6/50, 12%) increased in size, and three of these 6 patients, FO grew to be slightly larger than 3 mm. In contrast, all large defects (4 of 4, 100%) nearly doubled in size with postnatal growth. These 4 ELBW infants with enlargement of FO had a flap valve evident on echocardiogram obtained prior to discharge, and subsequently closed on outpatient follow-up echocardiograms, although time to resolution was variable (6 months - 3 years). One infant had presumptive resolution because of the presence of flap valve. CONCLUSION: No maternal or neonatal demographic characteristics were predictive of FO enlargement, although, demonstrable flap valve on discharge echocardiogram correlated with resolution of FO on outpatient follow-up echocardiogram. Therefore, based on our data, we recommend that ELBW infants born with large FO should have echocardiographic re-evaluation of the atrial septal opening prior to discharge, to specify the presence of a flap valve or lack thereof, which is an important detail that can help a neonatologist determine the need for outpatient cardiac follow-up.


Assuntos
Forame Oval Patente , Humanos , Lactente , Recém-Nascido , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/cirurgia , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Estudos Retrospectivos , Recém-Nascido Prematuro , Ecocardiografia
2.
Eur J Pediatr ; 181(4): 1449-1457, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34846557

RESUMO

Point-of-care ultrasound (POCUS) refers to the use of portable ultrasound (US) applications at the bedside, performed directly by the treating physician, for either diagnostic or procedure guidance purposes. It is being rapidly adopted by traditionally non-imaging medical specialties across the globe. Recent international evidence-based guidelines on POCUS for critically ill neonates and children were issued by the POCUS Working Group of the European Society of Pediatric and Neonatal Intensive Care (ESPNIC). Currently there are no standardized national or international guidelines for its implementation into clinical practice or even the training curriculum to monitor quality assurance. Further, there are no definitions or methods of POCUS competency measurement across its varied clinical applications. CONCLUSION: The Hippocratic Oath suggests medical providers do no harm to their patients. In our continued quest to uphold this value, providers seeking solutions to clinical problems must often weigh the benefit of an intervention with the risk of harm to the patient. Technologies to guide diagnosis and medical management present unique considerations when assessing possible risk to the patient. Frequently risk extends beyond the patient and impacts providers and the institutions in which they practice. POCUS is an emerging technology increasingly incorporated in the care of children across varied clinical specialties. Concerns have been raised by clinical colleagues and regulatory agencies regarding appropriate POCUS use and oversight. We present a framework for assessing the risk of POCUS use in pediatrics and suggest methods of mitigating risk to optimize safety and outcomes for patients, providers, and institutions. WHAT IS KNOWN: • The use POCUS by traditionally non-imaging pediatric specialty physicians for both diagnostic and procedural guidance is rapidly increasing. • Although there are international guidelines for its indications, currently there is no standardized guidance on its implementation in clinical practice. WHAT IS NEW: • Although standards for pediatric specialty-specific POCUS curriculum and training to competency have not been defined, POCUS is likely to be most successfully incorporated in clinical care when programmatic infrastructural elements are present. • Risk assessment is a forward-thinking process and requires an imprecise calculus that integrates considerations of the technology, the provider, and the context in which medical care is delivered. Medicolegal considerations vary across countries and frequently change, requiring providers and institutions to understand local regulatory requirements and legal frameworks to mitigate the potential risks of POCUS.


Assuntos
Currículo , Sistemas Automatizados de Assistência Junto ao Leito , Criança , Humanos , Recém-Nascido , Testes Imediatos , Medição de Risco , Ultrassonografia/métodos
3.
Am J Perinatol ; 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-35523411

RESUMO

OBJECTIVE: The objective of this study was to test the hypothesis that simulation training improves echocardiography skills. STUDY DESIGN: In this prospective study, 43 participants (16 neonatologists, 26 neonatology fellows, and 1 nurse practitioner) were tested on the simulator after 4 hours of didactic sessions on topographical cardiac anatomy and standard echocardiographic views. Participants were given 20 minutes to obtain and save the standard views. After the simulation hands-on training for 8 hours over 3 days, they were tested again. Each image was scored from 0 to 3 based on the image quality. Pre- and postsimulator training data were compared using both automated and visual scoring methods. RESULTS: After the hands-on simulator training, the automated median (interquartile) score for the quality of acquired images increased from 36 (22, 43) to 55 (48, 58), p < 0.0001. The increase was similar using visual scoring. The number of views with acceptable or good image quality (scores of 2 or 3) increased from 11 (6, 16) to 20 (17, 21), p < 0.0001. The neonatology fellows and faculty, as well as those with or without prior echocardiography experience, demonstrated significant improvement. CONCLUSIONS: Echocardiography simulation is an effective tool in improving echocardiography skills among neonatology care providers. KEY POINTS: · Simulation is effective in acquiring echocardiography skills among neonatology care providers.. · Simulation improves image acquisition in those with and without prior echocardiography experience.. · Effectiveness of simulation in retaining the acquired echocardiography skill should be investigated..

4.
Echocardiography ; 38(2): 217-221, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33319414

RESUMO

INTRODUCTION: Simulators are increasingly used for training in echocardiography. However, there is no objective method to assess the skills acquired. Our objective was to develop and test an automated method to assess echocardiography skills. METHODS: To automate the image quality evaluation, we expanded our previously developed neonatal echocardiography simulator to enable recording of images of the 26 standard cuts and process the image quality. We then compared the automated and visual methods in scoring image quality of the echocardiograms obtained by 22 trainees. RESULTS: Each echocardiographic image representing a slice of a three-dimensional volume possesses 3 axes (X, Y, and Z) that correspond to the roll, pitch, and yaw angles of the transducer, respectively. Therefore, if the placement and orientation of the transducer are correct, the acquired image represents the appropriate cardiac window with the desired orientation in all 3 axes. The automated system gives a score of 0 if the transducer is not in the appropriate cardiac window. A score of 1, 2, or 3 is given if the image falls within the range of one, two, or three angles, respectively. There was no difference in the image quality score between automated and visual assessment methods (46.0 ± 13.0 vs 45.1 ± 14.4, P = .19). The two methods had excellent correlation (r = .95). The bias and precision were 0.9 and 8.8, respectively. CONCLUSIONS: The automated method is comparable to visual method for assessment of image quality. The automated process allows for instantaneous feedback and has the potential to standardize assessment of echocardiography skills of trainees.


Assuntos
Competência Clínica , Ecocardiografia , Coração , Humanos , Recém-Nascido
5.
Am J Perinatol ; 38(2): 145-149, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-31430815

RESUMO

OBJECTIVE: This study aimed to determine the incidence of systemic to pulmonary collaterals (SPCs) in extremely low birth weight infants and to assess its clinical and hemodynamic significance beyond the neonatal period. STUDY DESIGN: Retrospective cohort study was conducted on 61 infants with echocardiogram performed at the time of discharge to determine the presence of SPC and to measure the right and left ventricular outputs and left atrium to aortic ratio. We compared two groups: small or no SPC (Group 1) to moderate or large SPC (Group 2) on demographics, clinical outcomes, and echocardiographic parameters. RESULTS: Sixty-one infants were included. The incidence of SPC was 57%; 21% of infants had moderate or large shunts and 31% had small SPC. Demographics, clinical outcomes, and echocardiographic parameters were not significantly different between small or no SPC and moderate to large SPC. CONCLUSION: More than half of the infants had SPC. The size of the shunt did not affect the clinical outcomes nor the echocardiographic parameters measured. All infants had cardiac output above the normative mean.


Assuntos
Aorta Torácica/anormalidades , Ecocardiografia Doppler em Cores , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Pulmão/irrigação sanguínea , Função Ventricular/fisiologia , Aorta Torácica/diagnóstico por imagem , Feminino , Ventrículos do Coração/diagnóstico por imagem , Hemodinâmica , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos
6.
J Perinatol ; 42(9): 1233-1237, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35851183

RESUMO

OBJECTIVE: Pulmonary hemorrhage is a rare but severe complication of extremely low birth weight (ELBW) infants. The association of hemodynamically significant patent ductus arteriosus (hsPDA) and the diameter of the foramen ovale (FO) with pulmonary hemorrhage has not been reported. STUDY DESIGN: Case control study of ELBW infants with and without pulmonary hemorrhage. Each ELBW infant with an echocardiogram within 48 h of pulmonary hemorrhage was analyzed. RESULT: 16 infants with pulmonary hemorrhage were matched with 32 controls by birth weight and gestational age. Echocardiogram showed hsPDA in all infants and those with pulmonary hemorrhage had significantly smaller patent FO [PFO] (1 vs 2.4 mm, p < 0.01) (OR 0.007; 95% CI 0.00007, 0.67 p = 0.03). Incidence of pulmonary hemorrhage was 8.9%. CONCLUSION: ELBW infants with hsPDA who experienced pulmonary hemorrhage had a significantly restricted or closed FO. Evaluation of FO should be considered with serial echocardiograms when evaluating for hsPDA.


Assuntos
Permeabilidade do Canal Arterial , Forame Oval Patente , Estudos de Casos e Controles , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Forame Oval Patente/complicações , Forame Oval Patente/diagnóstico por imagem , Hemorragia/complicações , Humanos , Lactente , Recém-Nascido de Peso Extremamente Baixo ao Nascer , Recém-Nascido , Recém-Nascido Prematuro
8.
IEEE J Transl Eng Health Med ; 6: 4700113, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30464863

RESUMO

There is a great need for training in pediatric echocardiography. In addition to physicians being trained in pediatric cardiology and echocardiography technologists, neonatologist, pediatric intensivists, and other health care professionals may be interested in such training. Since, there is limited opportunity of training on live patients, echocardiographic simulators may be of help. No simulator with complete range of echocardiographic modalities is available for neonates and infants. The aim of this project was to develop a mannequin-based echocardiographic simulator capable of simulating full range of pediatric 2D, color flow Doppler, spectral Doppler, and M-mode echocardiograms. A mannequin, a laptop computer, a magnetic tracking device, and a six-degree freedom (6DOF) sensor incorporated in a dummy transducer serve as the hardware platform of the simulator. We obtained six to seven 4D echocardiographic datasets in DICOM format through five acoustic windows from each infant along with a complete set of 2D video clips of color flow, Doppler, and M-mode. The 4D datasets are sliced into 3D slices using the visualization toolkit and are displayed as 2D echocardiograms through the information obtained by the 6DOF sensor. The coordinates from specific 3D slices triggers display of video clips of color flow, M-mode, and Doppler echocardiogram. Software written in C++ programming language controls the basic function of the program. The main simulator screen displays the full range of 2D echocardiograms including color flow Doppler, spectral Doppler, and M-mode from each acoustic window, whereas the side screen display the position and motion of the cutting planes through a 3D heart model. The system includes a software module to perform hemodynamic measurements from specific video clips images. Our hybrid, mannequin-based pediatric echocardiography simulator provides full range of pediatric echocardiography training experience. This simulator may help training in pediatric echocardiography for which there is a growing demand in clinical medicine.

9.
Biol Neonate ; 89(2): 82-7, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16158007

RESUMO

BACKGROUND: Administration of hydrocortisone and relatively high doses of dexamethasone increase blood pressure in volume- and pressor-resistant hypotensive preterm infants. However, little is known about the temporal relationship of dexamethasone administration and the improvement in blood pressure and the weaning of pressors/inotropes. Furthermore, there are no sufficient data available on whether a smaller dose of dexamethasone would also be effective in treating refractory hypotension. OBJECTIVE: To study the cardiovascular responses to low-dose dexamethasone in very low birth weight neonates with volume- and pressor-resistant hypotension. METHODS: Retrospective database review. Twenty-four preterm neonates (gestational age 26 (23-34) weeks; birth weight 801 (457-1,180) g; postnatal age 2 (1-24) days, medians (ranges)) who remained hypotensive despite volume administration and combined dopamine and dobutamine treatment at >or=30 microg/kg/min received dexamethasone 0.1 mg/kg followed by 0.05 mg/kg intravenously every 12 h for 5 additional doses if still on pressors >or=8 microg/kg/min. RESULTS: Two hours after the first dose of dexamethasone the mean blood pressure increased from 30 +/- 5 to 34 +/- 6 mm Hg (p < 0.001) and remained elevated at 4, 6, 12, and 24 h after treatment was started (p < 0.001). Six hours after the initial dose of dexamethasone the pressor/inotrope requirement decreased from 34 +/- 9 to 24 +/- 13 microg/kg/min (p = 0.001) and continued to decrease at 12 and 24 h (p < 0.001). Urine output also increased significantly during the first 6 h after dexamethasone (p < 0.001). CONCLUSIONS: Low-dose dexamethasone rapidly increases blood pressure and decreases pressor requirements in very low birth weight neonates with volume- and pressor-resistant hypotension.


Assuntos
Sistema Cardiovascular/efeitos dos fármacos , Dexametasona/administração & dosagem , Hipotensão/tratamento farmacológico , Doenças do Prematuro/tratamento farmacológico , Recém-Nascido Prematuro , Recém-Nascido de muito Baixo Peso , Dobutamina/administração & dosagem , Dopamina/administração & dosagem , Idade Gestacional , Humanos , Recém-Nascido , Estudos Retrospectivos
10.
Pediatrics ; 118(4): 1456-66, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17015536

RESUMO

OBJECTIVE: We sought to investigate whether the increase in blood pressure and decrease in vasopressor support after hydrocortisone administration are associated with changes in systemic hemodynamics in neonates who receive high-dosage dopamine to maintain blood pressure at the lowest acceptable levels. METHODS: In this prospective, observational study, preterm and term neonates who required dopamine > or = 15 microg/kg per minute to maintain minimum acceptable blood pressure received intravenous hydrocortisone 2 mg/kg followed by up to 4 doses of 1 mg/kg every 12 hours. Fifteen preterm and 5 term neonates without a patent ductus arteriosus composed the study population. Echocardiograms and vascular Doppler studies were performed immediately before the first dose of hydrocortisone and at 1, 2, 6 to 12, 24, and 48 hours thereafter. RESULTS: In the 15 preterm infants, during the first 12 hours of hydrocortisone treatment, the 28% increase in blood pressure paralleled that in the systemic vascular resistance without changes in stroke volume or cardiac output, whereas dopamine dosage decreased. By 24 hours, the dosage of dopamine continued to decrease, whereas stroke volume increased without additional changes in systemic vascular resistance. By 48 hours, dopamine dosage decreased by 72%; blood pressure and stroke volume increased by 31% and 33%, respectively; and systemic vascular resistance and cardiac output tended to be higher (14% and 21%, respectively) compared with baseline. Contractility, global myocardial function, and Doppler indices of blood flow in the middle cerebral and renal artery remained normal and unchanged. The findings in the 5 term infants showed a similar pattern for changes in cardiac function, systemic hemodynamics, and organ blood flow after hydrocortisone administration. CONCLUSIONS: In preterm and term neonates who require high-dosage dopamine to maintain blood pressure at the lowest acceptable levels, hydrocortisone improves blood pressure without compromising cardiac function, systemic perfusion, or cerebral and renal blood flow.


Assuntos
Anti-Inflamatórios/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Dopamina/uso terapêutico , Hidrocortisona/farmacologia , Recém-Nascido Prematuro , Anti-Inflamatórios/administração & dosagem , Encéfalo/irrigação sanguínea , Débito Cardíaco/efeitos dos fármacos , Relação Dose-Resposta a Droga , Ecocardiografia , Feminino , Humanos , Hidrocortisona/administração & dosagem , Recém-Nascido , Rim/irrigação sanguínea , Masculino , Estudos Prospectivos , Fluxo Sanguíneo Regional , Resistência Vascular/efeitos dos fármacos
11.
Biol Neonate ; 85(1): 32-6, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-14631164

RESUMO

The aim of the study was to detect changes in pulmonary function following ligation of a patent ductus arteriosus (PDA). Pulmonary function was recorded in 16 newborns (birth weight 1,081 +/- 166 g, gestational age 27.6 +/- 1.7 weeks) before and after ligation. No change in resistance of airways or mean airway pressure was observed. We found an increase in dynamic compliance (Cdyn) of 77% (p < 0.01), in tidal volume (TV) of 29% (p = 0.004), and in minute ventilation (MV) of 17% (p < 0.01) after the procedure. We demonstrated that pulmonary function improves after surgical ligation of the PDA. Because of considerable variation in intubated and spontaneously breathing premature newborns, we recommend the analysis of three main parameters: Cdyn, TV and MV for estimation of pulmonary mechanics in these infants.


Assuntos
Permeabilidade do Canal Arterial/cirurgia , Recém-Nascido Prematuro , Síndrome do Desconforto Respiratório do Recém-Nascido/fisiopatologia , Mecânica Respiratória/fisiologia , Resistência das Vias Respiratórias , Peso ao Nascer , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Ligadura , Complacência Pulmonar , Masculino , Respiração Artificial , Volume de Ventilação Pulmonar , Resultado do Tratamento
12.
J Perinat Med ; 30(6): 517-21, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12530110

RESUMO

We report a term infant with Pompe disease presenting in the immediate newborn period. The infant was born at 40 weeks' gestation, weighing 3600 g to a 32 year-old black female. Infant presented at delivery with massive hypertrophic cardiomyopathy and pulmonary hypertension. Diagnosis was confirmed by low alpha-glucosidase activity. The histopathology and electron microscopic findings were consistent with Pompe disease. This is the second reported case of Pompe disease presenting at delivery.


Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Doença de Depósito de Glicogênio Tipo II/diagnóstico , Adulto , Cardiomiopatia Hipertrófica/congênito , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Diagnóstico Diferencial , Eletrocardiografia , Evolução Fatal , Feminino , Doença de Depósito de Glicogênio Tipo II/diagnóstico por imagem , Humanos , Recém-Nascido , Gravidez , Radiografia , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa