1.
Sensors (Basel) ; 20(7)2020 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-32290063

RESUMO

In this work, SiNx/a-Si/SiNx caps on conductive coplanar waveguides (CPWs) are proposed for thin film encapsulation of radio-frequency microelectromechanical systems (RF MEMS), in view of the application of these devices in fifth generation (5G) and modern telecommunication systems. Simplification and cost reduction of the fabrication process were obtained, using two etching processes in the same barrel chamber to create a matrix of holes through the capping layer and to remove the sacrificial layer under the cap. Encapsulating layers with etch holes of different size and density were fabricated to evaluate the removal of the sacrificial layer as a function of the percentage of the cap perforated area. Barrel etching process parameters also varied. Finally, a full three-dimensional finite element method-based simulation model was developed to predict the impact of fabricated thin film encapsulating caps on RF performance of CPWs.

2.
Sensors (Basel) ; 20(3)2020 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-31991608

RESUMO

Smart Breath Analyzers were developed as sensing terminals of a telemedicine architecture devoted to remote monitoring of patients suffering from Chronic Obstructive Pulmonary Disease (COPD) and home-assisted by non-invasive mechanical ventilation via respiratory face mask. The devices based on different sensors (CO2/O2 and Volatile Organic Compounds (VOCs), relative humidity and temperature (R.H. & T) sensors) monitor the breath air exhaled into the expiratory line of the bi-tube patient breathing circuit during a noninvasive ventilo-therapy session; the sensor raw signals are transmitted pseudonymized to National Health Service units by TCP/IP communication through a cloud remote platform. The work is a proof-of-concept of a sensors-based IoT system with the perspective to check continuously the effectiveness of therapy and/or any state of exacerbation of the disease requiring healthcare. Lab tests in controlled experimental conditions by a gas-mixing bench towards CO2/O2 concentrations and exhaled breath collected in a sampling bag were carried out to test the realized prototypes. The Smart Breath Analyzers were also tested in real conditions both on a healthy volunteer subject and a COPD suffering patient.


Assuntos
Testes Respiratórios/métodos , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Doença Pulmonar Obstrutiva Crônica/terapia , Dióxido de Carbono/análise , Computação em Nuvem , Desenho de Equipamento , Humanos , Monitorização Fisiológica/economia , Oxigênio/análise , Estudo de Prova de Conceito
3.
Micromachines (Basel) ; 14(3)2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36984903

RESUMO

Monitoring of ions in real-time directly in cell culture systems and in organ-on-a-chip platforms represents a significant investigation tool to understand ion regulation and distribution in the body and ions' involvement in biological mechanisms and specific pathologies. Innovative flexible sensors coupling electrochemical stripping analysis (square wave anodic stripping voltammetry, SWASV) with an ion selective membrane (ISM) were developed and integrated in Transwell™ cell culture systems to investigate the transport of zinc and copper ions across a human intestinal Caco-2 cell monolayer. The fabricated ion-selective sensors demonstrated good sensitivity (1 × 10-11 M ion concentration) and low detection limits, consistent with pathophysiological cellular concentration ranges. A non-invasive electrochemical impedance spectroscopy (EIS) analysis, in situ, across a selected spectrum of frequencies (10-105 Hz), and an equivalent circuit fitting were employed to obtain useful electrical parameters for cellular barrier integrity monitoring. Transepithelial electrical resistance (TEER) data and immunofluorescent images were used to validate the intestinal epithelial integrity and the permeability enhancer effect of ethylene glycol-bis(2-aminoethylether)-N,N,N',N'-tetraacetic acid (EGTA) treatment. The proposed devices represent a real prospective tool for monitoring cellular and molecular events and for studies on gut metabolism/permeability. They will enable a rapid integration of these sensors into gut-on-chip systems.

4.
Polymers (Basel) ; 13(19)2021 Sep 23.
Artigo em Inglês | MEDLINE | ID: mdl-34641032

RESUMO

The Organ-on-chip (OOC) devices represent the new frontier in biomedical research to produce micro-organoids and tissues for drug testing and regenerative medicine. The development of such miniaturized models requires the 3D culture of multiple cell types in a highly controlled microenvironment, opening new challenges in reproducing the extracellular matrix (ECM) experienced by cells in vivo. In this regard, cell-laden microgels (CLMs) represent a promising tool for 3D cell culturing and on-chip generation of micro-organs. The engineering of hydrogel matrix with properly balanced biochemical and biophysical cues enables the formation of tunable 3D cellular microenvironments and long-term in vitro cultures. This focused review provides an overview of the most recent applications of CLMs in microfluidic devices for organoids formation, highlighting microgels' roles in OOC development as well as insights into future research.