Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Craniomaxillofac Surg ; 52(4): 420-431, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38461138

RESUMO

The study aimed to evaluate and discuss the use of an innovative PSI made of porous hydroxyapatite, with interconnected porosity promoting osteointegration, called MyBone Custom® implant (MBCI), for maxillofacial bone reconstruction. A multicentric cohort of 13 patients underwent maxillofacial bone reconstruction surgery using MBCIs for various applications, from genioplasty to orbital floor reconstruction, including zygomatic and mandibular bone reconstruction, both for segmental defects and bone augmentation. The mean follow-up period was 9 months (1-22 months). No infections, displacements, or postoperative fractures were reported. Perioperative modifications of the MBCIs were possible when necessary. Additionally, surgeons reported significant time saved during surgery. For patients with postoperative CT scans, osteointegration signs were visible at the 6-month postoperative follow-up control, and continuous osteointegration was observed after 1 year. The advantages and disadvantages compared with current techniques used are discussed. MBCIs offer new bone reconstruction possibilities with long-term perspectives, while precluding the drawbacks of titanium and PEEK. The low level of postoperative complications associated with the high osteointegration potential of MBCIs paves the way to more extensive use of this new hydroxyapatite PSI in maxillofacial bone reconstruction.


Assuntos
Implantes Dentários , Procedimentos de Cirurgia Plástica , Humanos , Durapatita/uso terapêutico , Tomografia Computadorizada por Raios X , Órbita
2.
J Oral Maxillofac Surg ; 66(7): 1439-45, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18571028

RESUMO

PURPOSE: Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons' perceptions of their use. PATIENTS AND METHODS: We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. RESULTS: Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients' chief complaint was swelling, lasting on average 5.3 +/- 2.8 days after placement and 4.5 +/- 2.6 days after removal. CONCLUSIONS: Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment.


Assuntos
Processo Alveolar/cirurgia , Placas Ósseas , Remoção de Dispositivo , Procedimentos de Ancoragem Ortodôntica/instrumentação , Adolescente , Adulto , Parafusos Ósseos , Criança , Implantação Dentária Endóssea , Feminino , Humanos , Masculino , Miniaturização , Procedimentos de Ancoragem Ortodôntica/métodos , Inquéritos e Questionários
3.
Adv Clin Exp Med ; 27(7): 1001-1008, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29999253

RESUMO

BACKGROUND: Validation of three-dimensional (3D) reconstructions of full dental arches with crowns and roots based on cone beam computed tomography (CBCT) imaging represents a key issue in 3D digital dentistry. OBJECTIVES: The aim of the study was to search for the most accurate in vivo windowing-based manual tooth segmentation using CBCT. The null hypothesis was that all applied windowing protocols were equivalent in terms of in vivo tooth volume measurement using CBCT. MATERIAL AND METHODS: This retrospective study was based on preoperative CBCT images from patients who underwent further tooth extractions for reasons independent of this study. Written informed consent was obtained from all the participants, and the study was approved by the Ethics Committee of Cliniques Universitaires Saint Luc (Brussels, Belgium). The radiological protocol was I-CAT CBCT, 0.3 mm slice thickness, 8 cm × 16 cm field of view, 120 kVp, and 18 mAs. A total of 36 teeth were extracted from 14 patients between the ages of 18 and 68 years. Using 3D Slicer software, segmentations were performed twice by 2 independent observers, with a 1-month time period between the 2 segmentations to study intraand inter-observer repeatability and reproducibility. Four windowing protocols (level/window) were applied: 1. 1131/1858, 2. 2224/4095, 3. 1131/4095, and 4. AUTO, an automatic protocol provided by default by the software. A total of 576 segmentations were performed. Tooth volumes were automatically calculated using the software. To compare the volumes obtained from CBCT segmentations with a gold-standard method, we laser-scanned the extracted teeth. RESULTS: Excellent intraand inter-observer intraclass correlations were found for all of the protocols used. The best windowing protocol was 1131/1858 for both observers. Tooth volumes were obtained by manual segmentation of the CBCT images and using windowing protocol 1131/1858. No significantly different tooth volumes were found by laser scanning. CONCLUSIONS: Our null hypothesis was rejected. Only windowing protocol 1131/1858 allowed for significantly closer 3D in vivo segmentation of a tooth compared to I-CAT CBCT, with excellent intra-observer repeatability and inter-observer reproducibility.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Interpretação de Imagem Assistida por Computador/métodos , Dente/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
Detalhe da pesquisa